FDASIA WG Regulations Sub-Group Report Out HIT Policy Committee FDASIA WG May 30 2013 www.jgoldman.info.

Slides:



Advertisements
Similar presentations
Medication Management
Advertisements

Quality Measures Vendor Tiger Team January 30, 2014.
USDOE Restraint and Seclusion: Resource Document, May 2012.
Quality Data for a Healthy Nation by Mary H. Stanfill, RHIA, CCS, CCS-P.
Towards Patient Safety in Closed-Loop Medical Device Systems Authors David Arney, Miroslav Pajic, Julian Goldman, Insup Lee, Rahul Mangharam, Oleg Sokolsky.
Primary Goal: To demonstrate the ability to provide efficient and accurate ICU care, formally close the ICU event with the patient’s PCP, and show interoperability.
What IMPACT Means to Physicians November 2014 Physician Champion: William Bradshaw, MD, FACS.
Strengthening the Medical Device Clinical Trial Enterprise
ICE-PAC Kickoff Meeting. Gap Analysis A proposed approach to this gap analysis is a two phase approach – Phase I: Identify Gaps using three responses.
MD PnP Program brief overview for OHT BoD Meeting September 9, 2011 Julian M. Goldman, MD Attending Anesthesiologist, Massachusetts General Hospital Medical.
Learning objectives:- 1. Introduction. 2. Define health record. 3. Explain types of health record. 4. Mention purposes of health record. 5. List general.
Lecture 6 Personal Health Record (Chapter 16)
Federal HIT Summit Nov 20, 2014 Washington, DC
Us Case 5 Delivery Coordination with Closed-loop OB/GYN and Hospital Interaction Care Theme: Maternal and Newborn Health Use Case 1 Interoperability Showcase.
Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Chapter 1 Overview of Nursing Process, Clinical Reasoning, and Nursing Practice.
Primary Goal: To demonstrate the ability to provide efficient and accurate transitional care, from the hospital OR suite, to the radiology department and.
ONC Policy and Program Update Health IT Policy Committee Meeting July 9, 2013 Jodi Daniel Director, Office of Policy and Planning, ONC 0.
Standard 5: Patient Identification and Procedure Matching Nicola Dunbar, Accrediting Agencies Surveyor Workshop, 10 July 2012.
Standard 4: Medication Safety Advice Centre Network Meeting Margaret Duguid Pharmaceutical Advisor February 2013.
Patient Safety Initiatives Kelly Cronin Director, Patient Safety and Outcomes Research Office of Policy and Planning Office of the Commissioner FDA.
2014 Summit Co-Convener:Founder: Patient Safety Science & Technology Summit 2014.
FDASIA REGULATIONS SUBCOMMITTEE May 22, Agenda 4:00 p.m.Call to Order – MacKenzie Robertson Office of the National Coordinator for Health Information.
Decision Support for Quality Improvement
Component 10 – Fundamentals of Workflow Process Analysis and Redesign
Leaders Manage Daily Operations
by Joint Commission International (JCI)
Work product for review and discussion by the FDASIA Regulation Subgroup; May not reflect the subgroup’s views REGULATORY WEAKNESSES A report of the typist.
 Definitions  Goals of automation in pharmacy  Advantages/disadvantages of automation  Application of automation to the medication use process  Clinical.
JCAHO UPDATE June The Bureau of Primary Health Care is continuing to encourage Community Health Centers to be JCAHO accredited. JCAHO’s new focus.
Smart Device Integration
1 MÉNARD, MARTIN, AVOCATS THE RIGHT TO SAFE CARE LEGAL ISSUES By: Mtre. Jean-Pierre Ménard, Ad. E.
Sedation.
Learning From Mistakes: Error Reporting and Analysis and HIT Unit12a: The Role of HIT in Error Detection & Reporting This material was developed by Johns.
Implementation of the Proposed Canada Consumer Product Safety Act (Bill C-6) Mandatory Reporting Health Canada ICPHSO 2009, Toronto.
Us Case 5 ED Encounter Resulting in with Follow-up Care at Multi-specialty Clinic Care Theme: Transitions of Care Use Case 8 Interoperability Showcase.
Standard 4: Medication Safety Advice Centre Network Meeting Margaret Duguid Pharmaceutical Advisor February 2013.
WRISTBAND STANDARDIZATION Presentation to NHONL – Rachel Rowe, Associate Executive Director November 6, 2007.
Us Case 5 ICU Event with Pharmacy and Pt Monitoring and Follow-up Care by PCP Care Theme: Transitions of Care, Medical Device Integration Use Case 15 Interoperability.
Health Management Information Systems
Origin and Process of Utah Guidelines Anna Fondario, MPH Utah Department of Health Violence and Injury Prevention Program.
HIT Policy Committee METHODOLOGIC ISSUES Tiger Team Summary Helen Burstin National Quality Forum Jon White Agency for Healthcare Research and Quality October.
Learning From Mistakes: Error Reporting and Analysis and HIT Unit12.1: HIT and Error Detection & Reporting Component 12/Unit 121 Health IT Workforce Curriculum.
Rapid Response Team. What is a Rapid Response Team? A Rapid Response Team or RRT, is a working team of clinicians who bring critical care expertise to.
Barcode Technology in healthcare Nowadays, published reports illustrate high rates of medical error (adverse events) and the increasing costs of healthcare.
Achieving Interoperability in Medical Device Technology to Support Innovation Julian M. Goldman, MD Director, Program on Interoperability, Mass General.
IEEE N SubmissionLiang Li VinnoSlide 1 Project: IEEE P Working Group for Wireless Personal Area Networks (WPANs) Submission.
Research in the Office of Vaccines Research and Review: Vision and Overview Jesse Goodman, M.D., M.P.H. Director, Center for Biologics Evaluation and Research.
© 2013 The McGraw-Hill Companies, Inc. All rights reserved. Ch 5 Professional Liability and Medical Malpractice.
Fundamentals of Workflow Analysis and Process Redesign
Applying New Science to Drug Safety Janet Woodcock, M.D. Acting Deputy Commissioner for Operations April 15, 2005.
Author : Elliot B. Sloane, Ph.D. American College of Clinical Engineering, President Villanova University Department of Decision.
PATHOLOGICAL AGING IN ELDERLY PEOPLE WITH ID. Aim of the Module 1.Learn about the most common diseases of old age; 2.Know how to avoid complications;
1 Session 3:Healthcare Provider, Clinician & Patient Perspective Julian M. Goldman, MD Medical Director, Biomedical Engineering Partners HealthCare, Boston,
Medical Device CPS Testbeds: Candidate Testbed for Research and Development on Cyber Physical Medical Device Systems Julian M. Goldman, MD Medical Director,
Intrathecal Morphine Usage in Hepatobiliary Surgery Dr David Cosgrave Dr Era Soukhin Dr Anand Puttapa Dr Niamh Conlon.
Improving Medication Safety: Closing the Loop with Smart Infusion Systems and EHR Interoperability Presented by: Tim Vanderveen, PharmD, MS.
27 June 2000Victor F. C. Raczkowski, M.D.1 Risk-Management Options Victor F. C. Raczkowski, M.D., M.S. Gastrointestinal Drugs Advisory Committee 27 June.
1 Developed by: U-MIC To start the presentation, click on this button in the lower right corner of your screen. The presentation will begin after the.
Complaint Handling Medical Device Reporting May 19, 2016 Rita Harden, Director Customer Relations & Regulatory Reporting.
Medical Product Safety Network (MEDSUN) an Interactive Surveillance System: Eliminating Barriers to Reporting and Creating Two-Way Communication with FDA.
FDA’s IDE Decisions and Communications
Nicole Denjoy COCIR Secretary General
Mary Alexander, MA, RN, CRNI®, CAE, FAAN Chief Executive Officer
Clinical Alarm Systems - NPSG Goal # 6 -
Electronic Health Information Systems
ALLEGATIONS OF ABUSE Internal Occurrence Reporting and Investigation.
Safety plan.
Pragmatic RCTs and the Learning Healthcare System
Tobey Clark, Director*, Burlington USA
SAMPLE ONLY Dominion Health Center: Your Community Healthcare Home (or another defining message) Dominion Health Center is a community health center.
Presentation transcript:

FDASIA WG Regulations Sub-Group Report Out HIT Policy Committee FDASIA WG May

Breakout Topics Clarification of “regulation” – FDA vs non FDA – Written vs. applied Notion of scope of “safety” Review of published literature for regulatory duplication and ambiguity – Deliverables will be: prioritized list of ambiguities and duplication requiring resolution Potential new issues that need to be avoided Proposed solutions – Will assess recommendations / work products from other groups to guide our recommendations

Examples to help clarify regulatory recommendations EHR-medical device data representation/gaps – Hazards cross FDA regulated and other spaces Data time stamping Technology complexity is not necessarily aligned with severity of risk – PCA example Interoperability Need for surveillance of HIT systems – Data logging / black box recording as a basis for improving system safety

Experiment Experiment: Simulator is set to create transient desaturation 99%->70%->99% 2 sec averaging time 8 sec averaging time Pulse Ox is set to: 16 sec averaging time What is the real O 2 saturation? Which value will be recorded in EHR? Averaging time should be included in EHR data Julian M. Goldman, MD / MGH Photos of pulse ox screens when they display the lowest saturation

Monitor GE Monitor Recorded Low SpO 2 Alarm Event “84%” No evidence of low SpO 2 in EHR Example: Low pulse oximetry value created an alarm. Low sat data is not recorded by EHR Alarm event is not captured in EHR WHY? Configuration? Intended performance? What if caused by performance issue with IT h/w (“Cisco router”) Julian M. Goldman, MD / MGH

Sources of variation in EHR documentation d/t Data Sampling Patient’s “actual” SpO2 minimum = 70% Pulse Oximeter Displayed SpO2 at 8-second averaging time SPO2= Seconds Example of possible EHR sample points for 1-minute recording Based on this example, EHR May record SpO2 as: 98% 92% 80% 75% Etc.

Device Clock Time Errors: Undermine system integrity and can create emergent hazards Clock time may originate in medical device, be consumed by other systems.

Medical Devices

EMR EMR time stamp error Blood gas analyzer in OR

Consolidated 4 Hospital Summary (Draft) Device Type CountStdDev OffsetAverage OffsetMaximum Offset Medical Devices (Excl. Workstations & Wall Clocks)13241:32:340:33:2616:42:10 All devices 17321:22:12 0:25:58 16:42:10 Networked Devices that Auto-Sync2910:02:160:00:530:31:16 Stand-alone Devices9501:46:380:46:0616:42:10 Hospital A520:31:110:30:251:52:00 Hospital B4951:41:230:32:5516:42:10 Hospital C4680:47:120:17:1013:39:28 Hospital D7171:27:240:26:3513:18:47 Draft – unpublished data

Incorrect dates Device Location Device Location (Room) Device Type Manufacturer/ Model Date Picture Taken Date on Device Device Offset (DAYS) General UnitPatient TowerBladder ScannerBVI /7/20111/8/201262D Adult ER Emergency Department Bladder Scanner Verathon Medical/ BVI /22/201111/2/ D Adult ER Emergency Department Bladder Scanner Verathon Medical/ BVI /22/201111/16/2011-6D ORHallway 1Imaging System Volcano S5 Cart Monitor 7/8/20117/7/20111D Neuro Angio Radiology Display *N/A*11/21/201111/18/2011-3D PACU Ultrasound Sonosite M- Turbo 11/29/20111/1/ years NICU VentilatorDrager/ Evita XL11/29/201111/1/20165 years Draft – unpublished data

Device Clock Time Errors: Undermine system integrity and can create emergent hazards Treatment errors, barriers to analysis of adverse events Is this an example of an “interop problem” that should be solved in the proposed framework?

Patient-Controlled Analgesia (PCA) system safety concerns PCA Pump (With patient button) Nurse call Patient Patients can call to request more analgesia, but, cannot call for help when over-medicated. Over-medication can cause respiratory and cardiac arrest Comprehensive monitoring is not typically used due to high false/nuisance alarm rate How can we improve safety of this system? Solution: Smarter alarms with sensor fusion + capability to stop medication infusion prior to injury

PCA Safety Issues continue saved-leah-2/ This is the story of an 11 year old who died from narcotic-induced respiratory depression. "Ten years after my daughter's death, nothing has changed in the codes of monitoring post- op patients continuously, until they leave the hospital. Alive." This is a statement from a multi-hospital coalition frustrated by ongoing adverse patient events: "A closed-loop system, which stops or pauses opioid dosing if respiratory depression is detected, is desirable. Systems are most ideally centrally monitored. In any case, alarms should be audible or otherwise available to the primary caregiver, and a mechanism for prompt response should be in place." "Carly Ann Pritchard... suffered an ankle injury and then underwent surgery to reduce lingering pain from her ankle injury. Unfortunately, although she survived surgery, she suffered brain damage because of an accidental overdose from a morphine-filled pain pump - after surgery. A California appeals court recently upheld a jury's award of about $9.9 million in damages."

Newsletter “A particularly attractive feature may be the ability to automatically terminate or reduce PCA (or PCEA) infusions when monitoring technology suggests the presence of opioid-induced respiratory depression. To facilitate such capabilities, we strongly endorse the efforts to develop international standards for device interoperability and device-device communication. It is critical that any monitoring system be linked to a reliable process to summon a competent health care professional to the patient's bedside in a timely manner.” Risk to patient of adding these capabilities is very low, although technology is sophisticated

Reporting … PCA as example Injury due to pump failure -> FDA report Injury due to HIT-related contribution (body weight error, allergy data lost, etc.) no report? Injury due to INABILITY integrate devices and HIT systems to prevent error – not reported

Interoperability Key enabler of HIT-based healthcare transformation Un-disciplined system integration has been introducing new hazards.

“Reporting” Leverage HIT for Surveillance IT’s strength is surveillance Can we reduce pre-market regulatory burden by improving surveillance of system – medical device + HIT components Single point of reporting adverse events and means to resolve issues – especially that cross regulated and “non regulated” spaces

Data Logger or Clinical Black Box Recorder Data Log supports Analysis and Playback for two complementary purposes: – Analysis of device / system interactions (debugging) – Analysis of adverse events involving patients (clinical) The log may include: – Commands – Button presses – Information about the status of devices – Device connections and disconnections Planes, Trains, Automobiles …

Proposed Next Steps wrt safety and regulatory framework Develop use cases to tease out Regulatory Framework requirements – Include high and low acuity – Usage venues: mHealth etc. Identify common needs across use cases (these or others)