Ammonia Analyzer Provides Real Time Process Control Capability PWO Operator Seminar – February 22, 2002 Greg Farmer - Littleton / Englewood WWTP Gary Girolimon.

Slides:



Advertisements
Similar presentations
NEW YORK WATER ENVIRONMENT ASSOCIATION WINTER MEETING – FEBRUARY 10, 2003 MAXIMIZING CSO CAPTURE THROUGH WET WEATHER OPERATIONS.
Advertisements

Analyze-Immediately Parameters pH Analyze Immediately Within 15 minutes of collection: pH Residual Chlorine Temperature Chlorine Dioxide Dissolved Oxygen.
Analyze Immediately Dissolved Oxygen. Topics of Discussion *Definition & Pointers *Applications:Water Quality & Sewage Treatment *Theory *Partial Pressure.
This PP is annotated (with a pointer) and narrated (for PP versions 2007 and later). The speaker icon on bottom right of each slide indicates this capability.
Copyright© 2014 Austin Analytics Group, LLC. Stand Alone System High Temperature System Hazardous Area System Universal/Remote Display System Copyright©
Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life goblueh2o.com Tel:
Aquascan. Aquascan - Introduction Aquascan is an online instrument capable of simultaneous multi-parameter measurement for a full range of water quality.
Biological waste water treatment
C. T Calculation Math for Water Technology MTH 082 (pg. 468) Math for Water Technology MTH 082 (pg. 468) “Required by Law”
1 CE 548 Analysis and Selection of Wastewater Flowrates and Constituent Loading.
Kinetics of the Decomposition of Crystal Violet Indicator.
1 Hardy Process Solutions – New Product Introduction HI6600 Series – Modular Sensor System Hardy delivers productivity solutions to manufacturers and processors.
Nitrification and Denitrification
Parameters Nitrate + Nitrite (NO 23 F) Nitrite (NO 2 F) Total Dissolved Nitrogen (TDN) Orthophosphate (PO 4 F) Total Dissolved Phosphate (TDP) Particulate.
ISE Ion Selective Electrodes Prepared By Michigan Department of Environmental Quality Operator Training and Certification Unit.
Discharge Monitoring Reports (DMRs)
RQflex ® - the pocket laboratory for quantitative on-site measurements in agriculture and horticulture
UR24 Process Refractometer
IC Controls 865 ppb Dissolved Oxygen System pH / ORP Conductivity Dissolved Oxygen Chlorine Standards ppb Galvanic Dissolved Oxygen.
WORKING PRINCIPLE OF DO AND pH PROBE Prepared by: Tan See Yean Yuganesh a/l Murugiah Jelita Bungin Nazzira Md Zin.
WASTE WATER TREATMENT FOR RITONAVIR PRODUCTION PLANT Presented by Wang Dong Mei July 8, 2000.
Math for Water Technology MTH 082 (pg. 468)
Reactors . ä Reactor: a “container” where a reaction occurs ä Examples: ä Clear well at water treatment plant (chlorine contact) ä Activated sludge tank.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Nutrient Removal Project Project rationale Sequencing Batch Reactor Software that.
CEE 453 Research Project Chris Garnic Nolan Rogers Creating Ideal Floc for Instant Startup of a Conical Flocculator.
Nitrogen Removal Project HJR Incorporated Heather Nelson Jeannette Harduby Rudi Schuech For Sparkling Clean Water Every Time.
Titremetric analysis Dr. Mohammad Khanfar. Concept of Titremetric analysis In general, we utilize certain property of a substance to be analyzed in order.
Flotation Flotation involves separation of solids from the water phase by attaching the solids to fine air bubbles to decrease the density of the particles.
AccuMax Multi-Point Injection Mechanics
EPA Precursor Gas Training Workshop Kevin A Cavender EPA-Office of Air Quality, Planning and Standards Precursor Gas Monitoring NO y Monitoring Training.
CAFS On-Line Orientation Montgomery County Fire & Rescue Service Operating the CAFS Controllers.
Visit us at:
EESIFLO International Pte Ltd
Experts in Chem-Feed and Water Treatment Chlorine Chemistry.
Phosphorus Removal in a Membrane Reactor System— A Demonstration Study Wayne Lorenz, P.E. and Matthew J. Gavin Wright Water Engineers, Inc. and Newell.
A New Twist on an Old Test for Activated Sludge Process Control Estes Park PWO Seminar October 22, 2004 Greg Farmer – Littleton / Englewood WWTP.
MineralScan Fill Level Signal Examples & Explanations - RNMC Introduction The MineralScan MillSlicer system normally consists of two fixed vibration sensors.
Biological Aerated Filtration (BAF) at the Denver Water Recycling Plant 2006 Water Reuse Workshop Golden, CO Russell Plakke, Denver Water.
Mercury Spill Response Instrumentation. Mercury Vapor Analyzers Jerome 431-X MVA (gold film) Lumex 915+ MVA (Atomic Absorption) Jerome J405 MVA.
Power Control System for a Concrete Durability Test Cabinet – Phase 2 Jacob Jameson Madhav Kothapalli Thomas Persinger Andrew Versluys.
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
PERFORMANCE OF A GRANULAR ACTIVATED CARBON BIOFILTER IN LOW STRENGTH WASTEWATER TREATMENT D. S. Chaudhary, H. H. Ngo and S. Vigneswaran Environmental Engineering.
Sundermeyer MAR 550 Spring Laboratory in Oceanography: Data and Methods MAR550, Spring 2013 Miles A. Sundermeyer Observations vs. Models.
Chapter 13 - Analytical Instrumentation 1 Chapter 14 Analytical Instrumentation.
Representative Sampling. Samples vs. Populations The population is the total or all of the possible answers we might get by sampling. All of the individuals.
Figure 2. Decrease in K and NO 3 over time in (a) AN1, (b) AN2, (c) CA2. Best fit determined by moving average. Potential for using anaerobic settling.
ProMinent Fluid Controls, Inc.
New Product Developments World Leaders in Combustion Management Solutions Mk7 Expansion PCB Mk7 Expansion PCB.
Sampling and Measurement for Inorganic Gaseous Pollutants.
Nitrification Action Plans
November 17, 2015 NC AWWA-WEA Annual conference
Free Residual Chlorine Measurement
Study of the U.S. Institute for the Environment Introduction to Water and Wastewater and Treatment Tuesday July 14, 2009.
Directed Assistance Module (DAM) 8: Nitrification Action Plans (NAPs)
Introduction to Recirculating Aquaculture Systems (RAS)
Brook Trout Care. Basic Daily Care Provide a “stress free’ environmentProvide a “stress free’ environment –Keep all insulation on except the front and.
K. I. S. S. K KChemical I Injection S System S Simplified.
Field Equipment Calibration PH, Temperature, Conductivity, Turbidity, Dissolved Oxygen, Free & Total Chlorine Gregory Langland CCSF.
EMSA 22 Lab Module 1 Field Equipment Calibration
Hemodialysis Lecture 3.
Presented by Harry C. Elinsky, Jr. Filtech, Inc.
Biological Phosphorus Removal from Wastewater Effluents
Private Septic Systems
Background Appledore Island, ME: Aerial View.
Enhancing Rapid Sand Filtration by Backwashing with Alum
Private Septic Systems
Increasing TKN Sample Determinations Through Automation
Lesson 12: Analog Signal Conditioning
Laboratory in Oceanography: Data and Methods
Advanced Wastewater Treatment
Presentation transcript:

Ammonia Analyzer Provides Real Time Process Control Capability PWO Operator Seminar – February 22, 2002 Greg Farmer - Littleton / Englewood WWTP Gary Girolimon - Ted Miller and Associates

Littleton / Englewood WWTP Process Schematic

Before Automating Process Control Diurnal ammonia variations led to:  Breakpoint chlorination  Inconsistent fecal coliform counts

Benefits  Dial in Final Effluent Ammonia Concentration  Centrate Return Timing Feedback  Maximize Nitrifying Trickling Filter (NTF) Efficiency  More Consistent Fecal Coliform Counts Through Control of Ammonia to Chlorine Ratio  Only 2-3 hours/month Maintenance

Ammonia Control

Nitrifying Trickle Filters

NTF Effluent Ammonia Control Modes By-Pass Valve Control  24 / 7 Effluent ammonia goal is 2.0 mg/l  Valve opens incrementally when ammonia is below 2.0 mg/l  Valve closes incrementally when ammonia above 2.0 mg/l Pump Control  If ammonia level increases above 7.0 mg/l, NTF pump speeds increase  When ammonia falls below 5.0 mg/l pump speeds decrease.  Pumps cannot go below a preset speed so that the minimum hydraulic loading is maintained.

By-Pass Valve Control If the analyzer detects ammonia level below the set point, the by- pass valve opens incrementally. If the analyzer detects ammonia levels above the set point, the by-pass valve closes incrementally.

By-Pass Valve Operation Ammonia > Valve closes when ammonia level increases above set point of 2 mg/l. Valve opens when ammonia level decreases below set point of 2 mg/l. < Valve position Nitrate >

Pump Speed Control If the analyzer detects ammonia levels below a set point the NTF pumps speeds decrease. Pump speed cannot go below a selected value so that the minimum hydraulic loading is maintained. If the analyzer detects ammonia levels above a set point the NTF pump speeds increase.

Pump Speed Control Operation By-pass valve Position > < NTF Pump Output Nitrate > < Ammonia

Chlorination

Controlled Chlorine to Ammonia Ratio

Fecal Coliform Counts

Analyzer Accuracy

Instrument Accuracy Analyzer vs. Lab Instrument values are extracted daily at 8:00 am and logged to the historical data server. Operators collect a sample near the analyzer at ~8:00 am for analysis by the lab.

Final Effluent Ammonia vs. STIP Daily Average

Nitrate Buoy Recalibrated During Regular Maintenance - Suspect Poor Quality 3 rd party Reagent

ISCO/STIP Process Buoy

STIP Process Buoy  Operates by being placed directly in wastewater (even activated sludge)  Separate buoys for ammonium and nitrate

STIP Process Buoy  Follows EPA approved methods of analysis  Operates in a batch analysis mode with typical analysis times of 3 to 5 minutes  Measuring range of mg/l as N for both nitrate and ammonium

Method of Analysis - General  Solenoid valve opens permitting sample to fill settling chamber via hydrostatic pressure  Sludge settles for pre programmed time period  Ammonium and nitrate measured with ion selective electrodes (ISE)  Solenoid valve reopens permitting supernatant to fill measurement chamber

Method of Analysis - NH 4 N  Caustic (NaOH) added till pH>11.5  Ammonium is converted to Ammonia (gas)  Ammonia measurement taken with gas selective electrode

Method of Analysis - NO 3 N  Conductivity sensor used to add reagent (ion suppression) to adjust ionic strength of solution  Concentration measured with nitrate selective electrode

Method of Analysis - Schematic

Calibration  Buoy calibration is done using three step standard addition method  Calibrated automatically once per day

Buoy Bulkhead Layout

Process Buoy In Open Position  Shows Settling Chamber Settling Chamber Measuring Chamber Measuring Chamber Electrodes Electrodes Valves Valves Amplifiers Amplifiers

Process Buoy Without Stainless Steel Housing

Controller  One controller can operate two buoys  LCD screen displays current reading and graph of last 6- hours of operation  Outputs: 4-20 mA 4-20 mA Bi-directional RS 232 Bi-directional RS 232

The End