Glucose test Ms. Ibtisam alaswad Ms. Nour A. taim.

Slides:



Advertisements
Similar presentations
Use and Maintenance of Micropipets
Advertisements

Hemoglobin A2.
Practical Clinical Hematology. Introduction HBA 2 is a protein which in humans is encoded by the HBA 2 gene. Hemoglobin A 2 is a normal variant of hemoglobin.
Hemoglobin A 2 Practical Hematology Lab - LAB 6 -.
Salk Institute Mobile Lab Gel Electrophoresis Student Instructions VWR Set up.
An Introduction to Microvolumetrics and Pipetting
Use and Maintenance of Micro-pipettes
Measuring Small Amounts Part 1: Using pipets and micropipets.
Quantitation of Methemoglobin
ENUMERATION OF MICROORGANISMS
Easy and inexpensive production of small quantities of 15 N 2 Step-by-step tutorial (Prepared by Juan-Pablo Hernandez) Step-by-step tutorial (Prepared.
Oct. 22, 2012 Generosity Ludicrous: causing or deserving laughter because of absurdity Do Now: What is a microliter? How many microliter are in one liter?
Molecular Biology Technical Skills. Skills  Micropipetting  Preparing solutions  Working with concentrations  Dilutions  Amounts  Agarose gel electrophoresis.
Micropipette Tutorial
DETERMINATION OF BLOOD GLUCOSE CONCENTRATION
Blood Glucose Test Dept.of Biochemistry. Determination of glucose concentration is important in the diagnosis and treatment of disorders of carbohydrate.
MLAB 1335 Immunology Serology Terry Kotrla, MS, MT(ASCP)BB
Introduction of CLS 333.  Course Description:  This is a required course in biochemistry for preparing a generalist in medical technology program. The.
Methods to Detect Red Cell Membrane Disorders
Methods to Detect Red Cell Membrane Disorders
Introduction to Equipment
Molecular Biology Technical Skills. Skills  Micropipetting  Preparing solutions  Working with concentrations  Dilutions  Amounts  Agarose gel electrophoresis.
All body tissues can utilize glucose, the principle and almost exclusive carbohydrate circulating in blood. Glucose is a reducing monosaccharide that.
Estimation of blood glucose in diabetes mellitus.
MLAB 1335 Immunology Serology Terry Kotrla, MS, MT(ASCP)BB
BCH302 [Practical] 1. There are three main methods of estimation the reducing sugar content in solution : 1. Reduction of cupric to cuprous salts. 2.
BY : Dr. Beenish Zaki, Instructor Department of Biochemistry (15 February 2012)
Mastering the micropipette. What is a micropipette? How do you use a micropipette? How can I determine if I’m pipetting correctly?
Practical Hematology Lab
CHAPTER 1: Some Tools of the Trade Lab Purpose of Lab 1.1 Become familiar with the small volumes of solutions used in molecular biology Introduce.
Use of the Labnet Micropipettor. Purpose of the Pipettor Biotechnologists use a pipettor to transfer precise amounts of liquids from one container to.
Micropipettes Why they are useful How they work How to care for them.
Serum biochemical parameters glucose assay Biochemistry Clinical practice CLS 432 Dr. Samah Kotb Lecturer of Biochemistry 2015.
Solutions used in medical laboratory. O Solution is a homogeneous mixture of two or more substances. O Solute is the dissolved substance, whereas solvent.
Automatic pipettes use and calibration
By: EID ALATAWI Serial Dilution. Introduction: Many of the laboratory procedures involve the use of dilutions. It is important to understand the concept.
Whole blood was the sample of choice for analysis However, values for glucose in whole blood are less than in plasma since red blood cells contain only.
Oral Glucose Tolerance Test (OGTT)
Estimation of blood glucose in diabetes mellitus.
Use and Maintenance of Micro-pipettes
Determination Of Albumin In Serum By Bromocresol Green Method
Outline of Today’s lecture 1. Discuss the different types of cholesterol 2. Identify healthy cholesterol levels 3. Clinical significance of cholesterol.
Exp #1 Glucose Quantitative determination of glucose in serum or plasma.
Solutions used in medical laboratory
Triglyceride determination
An Introduction to Microvolumetrics and Pipetting
Automatic Pipettes Use And Calibration
Oral glucose tolerance test (GTT)
Techniques in Molecular Biology 2017 Fall Lecture -2-
Practical Analysis Using Spectrophotometer
Cerebrospinal Fluid (CSF) Analysis for total protein
Measuring Volume.
MLAB 1335 Immunology Serology Terry Kotrla, MS, MT(ASCP)BB
مهارتك الأساسية في معامل التقنية الحيوية
Methods to Detect Red Cell Membrane Disorders
Techniques in Molecular Biology 2017 Fall Lecture -2-
Blood Glucose Test By Fifth Stage Student 18 Dr. Sakar Karem Abdulla
Use of the Labnet Micropipettor
Use and Maintenance of Micro-pipettes
Exp#4 Cholesterol Quantitative determination of total cholesterol in serum /plasma by enzymatic color/endpoint method.
Introduction To Medical Technology
An Introduction to Microvolumetrics and Pipetting
Introduction of CLS 333 Demonstrated by: Daheeya AlEnazi 3rd floor,office#110 office hour: wed 9-10.
Practical Hematology Lab Osmotic Fragility Test
Measurement & Micropipetting
Laboratory Glassware.
Urine Analysis Protein. Protein: Urine normally contains a scant amount of protein, which derives both blood and urinary tract itself. Proteins present.
Practical Hematology Lab Osmotic Fragility Test
Practical Hematology Lab Osmotic Fragility Test
Micropipette Tutorial
Presentation transcript:

Glucose test Ms. Ibtisam alaswad Ms. Nour A. taim

Introduction Blood glucose :_ The main sugar that the body makes from the food in the diet. Glucose is carried through the bloodstream to provide energy to all cells in the body. Cells cannot use glucose without the help of insulin. Glucose is a simple sugar (a monosaccharide). The body produces it from protein, fat and, in largest part, carbohydrate. Ingested glucose is absorbed directly into the blood from the intestine and results in a rapid increase in blood glucose. Glucose is also known as dextrose.

The Objectives to be achieved To understand the principle to spectrophotometer A spectrophotometer is used to measure the amount of light a sample (be it liquid or solid) absorbs. Light is passed through the sample and a detector measures the intensity of that light that passes through the sample and hits that detector. To determine the blood glucose concentration as an application of spectrophotometer use To know how to use some devices in the lab

The principle of Glucose test Glucose present in the plasma is oxidized by the enzyme glucose oxidase (GOD) to gluconic acid with the liberation of hydrogen peroxide, which is converted to water and oxygen by the enzyme peroxidase (POD). 4_aminophenazone, an oxygen acceptor, takes up the oxygen and together with phenol forms a pink coloured chromogen which can be measured at 515nm.

Specimen type, collection and storage Plasma is the specimen of choice for glucose estimation. Plasma glucose levels have been checked to be quite stable for 6 hours at room temperature ( C) in the author ’ s laboratory. It is important that plasma should be separated from the cells soon after collection, preferably within 1 hour. About 2 ml of the patient ’ s blood should be collected by venipuncture into a tube containing a mixture of potassium ethylene diaminetetraacetate (EDTA) sodium fluoride at a ratio 1:2 (W/W). Five mg of the mixture is adequate for 2 ml of blood. The tube should be gently but thoroughly shaken for complete mixing.

Procedure ControlSampleStandardBlank __ 10 µ l__Standard __10 µ l__ Sample 1.0 µ l__ Control __1.0 ml Reagen

Procedure Mix. Incubate 10 min. at 37ºc. or 30 min at room temperature. Measure the ABSORBANCE at 505nm ( ) against the blank. The color is stable 30min

Discussion Calculation Glucose (mg/dl) = (Abs. sample/Abs. standard)* standard conc. Linearity This method is linear up to 500mg/dl. If the glucose concentration is greater than 500mg/dl., dilute the sample 1:2 with saline solution and repeat the determination and multiply the result by 2 Reference value Serum: mg/dl. Plasma glucose: Fasting: 70 –110 mg/dl

How to Use a Micropipettor The micropipettor is used to transfer small amounts (< 1 ml) of liquids. The scales on micropipettors are in microliters (1000μl = 1 ml).

How to Use a Micropipettor 1.Never exceed the upper or lower limits of these pipettors. 2. Set the desired clockwise to increase volume by turning the centrally located rings volume or counterclockwise to decrease volume. 3. Place a tip on the discharge end of the pipettor. NOTE: If sterile conditions are necessary do not allow the pipet tip to touch any object (including your hands).

How to Use a Micropipettor 4. The plunger will stop at two different positions when it is depressed each point indicate the volume to be taken. 5. Depress the plunger until you feel the initial resistance and insert tip into the solution, just barely below the surface of the liquid and not as deep as possible.

How to Use a Micropipettor 6. Carefully and slowly release plunger. NOTE: If the solution you are pipetting is viscous, allow the pipet tip to fill to final volume before removing it from solution to avoid the presence of bubbles in the plastic tip which will result in an inaccurate volume. 7. Discharge the solution into the appropriate container by depressing plunger. This time, depress the plunger to the point of initial resistance, wait one second, and then continue pressing the plunger as far as it will go in order to discharge the entire volume of solution. 8.Remove tip by pressing down on the tip discarder.

NOTES Never point a pipettor up. This may cause liquid to run down into the pipettor destroying it. When withdrawing liquids with the pipettor, always release the plunger slowly. This prevents liquid from rushing into the end of the pipette and clogging it up. This is especially important with large volume pipettors ( μl). Be sure you use the proper size tip for each pipettor. Always use a new tip for each different liquid. Use the correct pipettor for the volume that is to be dispensed. Never use the μl pipette to dispense volumes below 200 μl. going below or above the range of the micropipettor may damage the instrument.