RECD Refresher Course 17th November 2004 Setting prescriptive targets Greg Nassar Clinical Scientist MCHAS.

Slides:



Advertisements
Similar presentations
Do digital hearing aid users benefit from using an fm system in class? YES ! Wave 4 SFR 17/05/04.
Advertisements

Figures for Chapter 9 Prescription
ox.eu Conny Andersson IEC
Real-ear Measurements with the A-35
RECD Refresher Course 17th November 2004 In Situ Versus Coupler Verification Working Smarter ! Ed Brown Consultant Audiological Scientist MCHAS University.
6500-CX Calibration. Warning Signs a.k.a. Your 6500-CX might be out of calibration if... n The analyzer doesn’t level. n Distortion measurements seem.
Alternative Assessments for Musicians Marshall Chasin, AuD., M.Sc., Reg. CASLPO, Aud(C) Musicians’ Clinics of Canada.
The self-fitting hearing aid Elizabeth Convery, Harvey Dillon, Gitte Keidser, Lyndal Carter, and Dan Zhou National Acoustic Laboratories, Sydney, Australia.
Viewer’s notes... to help you …  At the bottom left of each page there is a page number, when the slide has finished an automated sequence a small star.
Creating sound value TM The perceptibility, acceptability, and benefit of transitioning to new gain targets in experienced hearing aid wearers with moderately.
An Update on Hearing Aid Testing
Probe Tube Microphone Measurements (Basics and Definitions) Greg Nassar MCHAS Team University of Manchester.
Verifying Open-Ear Fittings With Speech-Mapping
The effect of advanced signal processing strategies in hearing aids on user performance and preference Gitte Keidser, Lyndal Carter, and Harvey Dillon.
MCHAS Modernising Children’s Hearing Aid Services Acoustic Feedback Reduction.
Is the hearing aid always to blame when things get really noisy? Gitte Keidser 1, Elizabeth Convery 1, Jürgen Kiessling 2, and Ruth Bentler 3 1 National.
FP35 Hearing Aid Analyzer
Pure Tone Audiometry Basic Principles of Sound The Audiometer
Program.
1 Auditory Sensitivity, Masking and Binaural Hearing.
Objective Clinical Verification of Digital Hearing Aid Functions
Electroacoustic Testing of DSP Hearing Aids Christine Cameron & Mary Hostler MCHAS Team University of Manchester.
Real Ear Testing Measures how a hearing aid performs in the ear Real Ear Unaided Response (REUR) Real Ear Aided Response (REAR) Real Ear Insertion Response.
Fitting Formulas Estimate amplification requirements of individual patients Maximize intelligibility of speech Provide good overall sound quality Keep.
ANSI Overview Hearing Aid Testing and Verification What is ANSI?
TOPIC 4 BEHAVIORAL ASSESSMENT MEASURES. The Audiometer Types Clinical Screening.
Modernising Children’s Hearing Aid Services RECD Measurements Wave 4 EJB 17/05/04.
Lecture 12 10/03/2015  The child is conditioned to wait for a frequency specific stimuli in the sound field and respond using a play activity  used.
Deborah Edwards, MS,CCC-A Dawn Ruley, AuD, CCC-A Advanced FM: Programming & Verification.
Modernising Children’s Hearing Aid Services HEARING AID REVIEWS Greg Nassar.
Compression 101.
Introduction to the FONIX 7000 Hearing Aid Test System Software version 1.60.
Pseudohypacusis/ Nonorganic/ Functional Hearing Loss:
ASHA 1997 HEARING SCREENING GUIDELINES ASHA Guidelines for Hearing Screening - Children 1997.
HISTORY OF HEARING TESTING. Audiology Audio - Latin…to hear, pertaining to hearing Logy - Greek…logus…science Therefore the science of hearing and hearing.
Modernising Children’s Hearing Aid Services Sound Field Testing MCHAS TEAM Wave 4 SFR 17/05/04.
Figures for Chapter 4 Electroacoustic Performance
Figures for Chapter 6 Compression
Fitting and Evaluation of FM Systems for Cochlear Implant Users Linda M. Thibodeau.
Introduction to the 8000 Hearing Aid Test System By: Kristina Frye Frye Electronics, Inc.
The audiometric threshold: measured in-situ, automated, and by the hearing aid Gitte Keidser, Harvey Dillon, Anna O’Brien, Dan Zhou, Lyndal Carter, Ingrid.
Get ready for the session 1.Configure your audio options using the Audio Setup wizard 2.Check/update your Profile (via your name in the in the Participants.
Reading an Audiogram. Air vs. Bone Conduction A/C  Via TDH-50P headphones Placed on Pinna  Checks the validity of entire ear system  Tests that ipsilateral.
DEVELOPMENT OF NAL-NL2 Harvey Dillon, Gitte Keidser, Teresa Ching,
Experiences to Date Comfort levels must be checked before the procedure is started 11 adults have been fitted and did not like the initial DSL fitting.
Fitting Amplification by 6 months of age: Best Practices Susan Scollie, Ph.D. & Marlene Bagatto, M.Cl.Sc. National Centre for Audiology The University.
Figures for Chapter 10 Hearing Aid Selection Dillon (2001) Hearing Aids.
PEDIATRIC AND MENTALLY RETARDED POPULATIONS. Minimum Response Levels (MRL’s) No response at threshold Respond at supra-threshold levels Response = hearing.
Figures for Chapter 14 Binaural and bilateral issues Dillon (2001) Hearing Aids.
New Features on the FONIX FP35 Hearing Aid Analyzer
Fitting and Evaluation of FM Systems for HA Users.
Loudness level (phon) An equal-loudness contour is a measure of sound pressure (dB SPL), over the frequency spectrum, for which a listener perceives a.
FP35 Hearing Aid Analyzer
Threshold of detection Established according to some criterion.
AUDIOMETRY An Audiometer is a machine, which is used to determine the hearing loss in an individual.
Figures for Chapter 8 Candidacy Dillon (2001) Hearing Aids.
Test procedure Several different methods followed. Several different methods followed. Most standard: Recommended by Carhart and Jerger (1959) and ASHA.
Hz A A A A A A LDL for speech Aided Speech output Functional Gain: The way.
CD 491: Audiology Lecture 2 Clinical Applications.
A COMPARISON OF wRECD AND RECD VALUES AND TEST-RETEST RELIABILITY
Equipment for Measuring Hearing and Calibration
Copyright © American Speech-Language-Hearing Association
Copyright © American Speech-Language-Hearing Association
REM AND SREM FITTING COMPARISONS OF VENTED AND UNVENTED HEARING AIDS USING THE AUDIOSCAN VERIFIT AND VERIFIT2 Paula Folkeard, AuD1, John Pumford, AuD2,
Introduction to the 7000 Hearing Aid Test System
Copyright © American Speech-Language-Hearing Association
Copyright © American Speech-Language-Hearing Association
MAAC 2018 Real-ear Hands on Lab
HEARING ASSESSMENT: PURE TONE AUDIOMETRY
Infection Prevention and Control
Presentation transcript:

RECD Refresher Course 17th November 2004 Setting prescriptive targets Greg Nassar Clinical Scientist MCHAS

RECD Refresher Course 17th November 2004 Prior to child arriving Select a clientSelect a client PTA (save and close as we don’t have PMS)PTA (save and close as we don’t have PMS) Select appropriate hearing aidSelect appropriate hearing aid Open HA software (new battery, connect leads, switch on then….)Open HA software (new battery, connect leads, switch on then….) Open REM softwareOpen REM software –DSL [i/o] or NAL-NL1 set-up screens –Calibrate new probe tube –Prepare coupler response

RECD Refresher Course 17th November 2004 DSL [i/o] set up on Unity Access via the screwdriver iconAccess via the screwdriver icon Check DOBCheck DOB Transducer- how did you test hearing?Transducer- how did you test hearing? HL to SPL- measured or manualHL to SPL- measured or manual RE to 2cc- Measured or manaulRE to 2cc- Measured or manaul Max Output (ULLs)Max Output (ULLs) Speech- UWO is specific child spectrum that takes child’s own voice into account (see Phonak Focus 20)Speech- UWO is specific child spectrum that takes child’s own voice into account (see Phonak Focus 20) Circuit- majority of HA on contract have fixed CR. If planning a linear strategy set to LINEARCircuit- majority of HA on contract have fixed CR. If planning a linear strategy set to LINEAR Compr. Threshold- minimum or if WDRC strategyCompr. Threshold- minimum or if WDRC strategy

RECD Refresher Course 17th November 2004 DSL [i/o] set up on Aurical First screenFirst screen Check DOBCheck DOB Transducer- how did you test hearing?Transducer- how did you test hearing? –Sound Field (uses REUR for HL- SPL transform) –Insert/custom (used EAR3 with earmould) –TDH- uses average REDD (discussed earlier) –ME Insert (more on this later) HL to SPL- predicted or measuredHL to SPL- predicted or measured HI typeHI type Compression type- as beforeCompression type- as before Compression Threshold- as beforeCompression Threshold- as before

RECD Refresher Course 17th November 2004 NAL-NL1 set up on Unity Similar to DSLi/o except:Similar to DSLi/o except: –Number of hearing aids –Limiting refers to how MPO on hearing aid is adjusted (single channel or multichannel) –Earmould acoustics –Number of compression channels ((new DSL m[i/o]) –Uses BC values (new DSL m[i/o]) –Can measure REIR & REAG

RECD Refresher Course 17th November 2004 NAL-NL1 set up on Aurical Same as previous but with additional control to select REAG or REIGSame as previous but with additional control to select REAG or REIG

RECD Refresher Course 17th November 2004 Hello young man! OtoscopyOtoscopy Tympanometry (if not performed during behavioural audiometry)Tympanometry (if not performed during behavioural audiometry) Measure RECDMeasure RECD –Save session, then re-open from session list Send him out/for a break/breather etc…Send him out/for a break/breather etc… Attach aid to couplerAttach aid to coupler –Close lid –50, 65, 80 dB speech noise (modulated on Aurical) –90 dB pure tone sweep Program aidProgram aid

RECD Refresher Course 17th November 2004 Demo then hands on practical session