Raman Spectroscopy A) Introduction IR Raman
Raman Spectroscopy Laser 4880 Å. Raman Spectroscopy.
Infrared (IR).
Mass Spectrometry Introduction:
Structural Information
Raman Spectroscopy Raman effect is a 2-photon scattering process
Raman Spectroscopy 1923 – Inelastic light scattering is predicted by A. Smekel 1928 – Landsberg and Mandelstam see unexpected frequency shifts in scattering.
1 CHAPTER 9 Spectroscopy: the study of the interaction of energy with matter Energy applied to matter can be absorbed, emitted, cause a chemical change,
Molecular Structure and Organic Chemistry The structure of a molecule refers to the arrangement of atoms within the molecule. The structure of a molecule.
Raman Spectroscopy Laser 4880 Å. Raman Spectroscopy.
Lecture 5 An Introduction to Spectroscopy Electromagnetic radiation, electromagnetic wave Emission, absorption, fluorescence.
Vibrational Spectroscopy HH O Bend. Diatomic Molecules So far we have studied vibrational spectroscopy in the form of harmonic and anharmonic oscillators.
Spectroscopy Infrared Spectra. Infrared spectra in this presentation are taken by permission from the SDBS web site: SDBSWeb:
Lecture 3 INFRARED SPECTROMETRY
Time out—states and transitions Spectroscopy—transitions between energy states of a molecule excited by absorption or emission of a photon h =  E = E.
Fourier transform infrared spectroscopy[FTIR]
X-Ray Diffraction Spectroscopy RAMAN Microwave. What is X-Ray Diffraction?
Common types of spectroscopy
INFRARED SPECTROSCOPY (IR)
Infra Red Spectroscopy
 PART Requirements for Spectroscopic Techniques for Polymers 1. High resolution 2. High sensitivity (>1%) 3. High selectivity between molecular.
KHS ChemistryUnit 3.4 Structural Analysis1 Structural Analysis 2 Adv Higher Unit 3 Topic 4 Gordon Watson Chemistry Department, Kelso High School.
Spectroscopy: IR Renee Y. Becker Valencia Community College CHM 2011.
1 University of Petra Faculty of Science & Arts Department of Chemistry Seminar I.R Spectroscopy By Firas Al-ouzeh Supervisor : Nuha I. Swidan Summer 2007.
RamanRaman. Scattering Tyndall scattering – if small particles are present During Rayleigh scattering (interaction of light with relatively small molecules)
Infrared Spectroscopy Chapters Chapter 7- I.
10-1 Application of IR Raman Spectroscopy 3 IR regions Structure and Functional Group Absorption IR Reflection IR Photoacoustic IR IR Emission Micro.
Structure Determination by Spectroscopy Mass spectroscopy Ultraviolet-visible spectroscopy Infrared spectroscopy Nuclear magnetic resonance spectroscopy.
Optical Characterization methods Rayleigh scattering Raman scattering transmission photoluminescence excitation photons At a glance  Transmission: “untouched”
The Nobel Prize in Physics 1930 "for his work on the scattering of light and for the discovery of the effect named after him" Sir Chandrasekhara Venkata.
Infrared Spectroscopy. Spectroscopy The energy of the interaction of electromagnetic radiaiton (light) with molecules Several different techniques: Infrared.
Advanced Analytical Chemistry – CHM 6157® Y. CAIFlorida International University Updated on 9/18/2008Chapter 5Raman Spectrometry Chapter 5 Raman Spectrometry.
States and transitions
Raman Spectroscopy Lord Rutherford, 1930 April 10th, 2014.
Chapter 2: IR Spectroscopy Paras Shah
J. 1.1 Elastic scattering and inelastic scattering Elastic scattering (Rayleigh scattering) : no change in energy of light EMR induces oscillating electric.
Raman Effect The Raman Effect is the phnomenon of scattering of light, one of the most convincing proofs of the quantum theory Was discovered in 1928 Raman.
Raman Spectroscopy A) Introduction IR Raman
Infrared Spectroscopy
INFRA RED SPECTROSCOPY A guide for A level students KNOCKHARDY PUBLISHING.
1.1 What’s electromagnetic radiation
The Electromagnetic Spectrum
Infrared Spectroscopy (IR) Fourier Transform Infrared (FTIR)
Infrared Spectroscopy
Infrared Spectroscopy
IB NOTES: Modern Analytical Chemistry. Definitions: Qualitative Analysis: The detection of the __________________ but not the __________ of a substance.
Lecture 3 Mass Spectrometry and Infrared Spectroscopy.
An introduction to Spectrometric Methods. Spectroscopy Definition Spectroscopy is a general term for the science that deal with the interactions of various.
CHAPTER 11 Alkenes; Infrared Spectroscopy and Mass Spectroscopy.
Infra-red Spectroscopy
INFRA RED SPECTROSCOPY
Introduction & Its instrumentation
Introduction and Principle of IR Spectrophotometry
Molecular Vibrations and IR Spectroscopy
IR-Spectroscopy IR region Interaction of IR with molecules
Molecular Vibrations and IR Spectroscopy
IR-Spectroscopy IR region Interaction of IR with molecules
INFRARED SPECTROSCOPY Dr. R. P. Chavan Head, Department of Chemistry
Raman Spectroscopy A) Introduction IR Raman
Class :- B.Sc.III (Physics)
SPECTROPHOTOMETRY Applied Chemistry.
The Electromagnetic Spectrum
Molecular Vibrations and IR Spectroscopy
化工群英文示例 沙鹿高工 簡佩琳.
Presentation On INFRARED SPECTROSCOPY
Spectroscopy Infrared Spectra.
IR-Spectroscopy Atoms in a molecule are constantly in motion
INFRA RED SPECTROSCOPY
Raman Spectroscopy A) Introduction IR Raman
Presentation transcript:

Assistant Professor Dr. Akram Raheem Jabur Spectroscopy FTIR RAMAN By Assistant Professor Dr. Akram Raheem Jabur  

Spectroscopy “seeing the unseeable” Using electromagnetic radiation as a probe to obtain information about atoms and molecules that are too small to see. Electromagnetic radiation is propagated at the speed of light through a vacuum as an oscillating wave.

electromagnetic relationships: λυ = c λ µ 1/υ E = hυ E µ υ   E = hc/λ E µ 1/λ λ = wave length υ = frequency c = speed of light E = kinetic energy h = Planck’s constant λ c

  Two oscillators will strongly interact when their energies are equal. E1 = E2 λ1 = λ2 υ1 = υ2 If the energies are different, they will not strongly interact! We can use electromagnetic radiation to probe atoms and molecules to find what energies they contain.

some electromagnetic radiation ranges Approx. freq. range Approx. wavelengths Hz (cycle/sec) meters Radio waves 104 - 1012 3x104 - 3x10-4 Infrared (heat) 1011 - 3.8x1014 3x10-3 - 8x10-7 Visible light 3.8x1014 - 7.5x1014 8x10-7 - 4x10-7 Ultraviolet 7.5x1014 - 3x1017 4x10-7 - 10-9 X rays 3x1017 - 3x1019 10-9 - 10-11 Gamma rays > 3x1019 < 10-11  

  Two oscillators will strongly interact when their energies are equal. E1 = E2 λ1 = λ2 υ1 = υ2 If the energies are different, they will not strongly interact! We can use electromagnetic radiation to probe atoms and molecules to find what energies they contain.

Spectroscopy λ = 2.5 to 17 μm υ = 4000 to 600 cm-1  These frequencies match the frequencies of covalent bond stretching and bending vibrations. Infrared spectroscopy can be used to find out about covalent bonds in molecules. IR is used to tell: 1. what type of bonds are present 2. some structural information

IR source è sample è prism è detector   graph of % transmission vs. frequency => IR spectrum 100 %T 4000 3000 2000 1500 1000 500 v (cm-1)

toluene

Some characteristic infrared absorption frequencies   BOND COMPOUND TYPE FREQUENCY RANGE, cm-1 C-H alkanes 2850-2960 and 1350-1470 alkenes 3020-3080 (m) and RCH=CH2 910-920 and 990-1000 R2C=CH2 880-900 cis-RCH=CHR 675-730 (v) trans-RCH=CHR 965-975 aromatic rings 3000-3100 (m) and monosubst. 690-710 and 730-770 ortho-disubst. 735-770 meta-disubst. 690-710 and 750-810 (m) para-disubst. 810-840 (m) alkynes 3300 O-H alcohols or phenols 3200-3640 (b) C=C alkenes 1640-1680 (v) aromatic rings 1500 and 1600 (v) C≡C alkynes 2100-2260 (v) C-O primary alcohols 1050 (b) secondary alcohols 1100 (b) tertiary alcohols 1150 (b) phenols 1230 (b) alkyl ethers 1060-1150 aryl ethers 1200-1275(b) and 1020-1075 (m) all abs. strong unless marked: m, moderate; v, variable; b, broad

n-pentane 2850-2960 cm-1 CH3CH2CH2CH2CH3 sat’d C-H 3000 cm-1

IR of ALKENES =C—H bond, “unsaturated” vinyl (sp2) 3020-3080 cm-1 + 675-1000 RCH=CH2 + 910-920 & 990-1000 R2C=CH2 + 880-900 cis-RCH=CHR + 675-730 (v) trans-RCH=CHR + 965-975 C=C bond 1640-1680 cm-1 (v)

The Raman Effect Raman Compared to IR Induced Dipole Sample in Equilibrium Linear Molecule O C Emission Relaxation Excitation Laser Excitation Induced Dipole Emission Relaxation There must be polarizability for Raman Effect to take place Raman Compared to IR H - Cl + - Uneven distribution of charge = Dipole Moment Dipole moments relate to IR absorption Polarizability relates to Raman scattering Polarizability  how “squishy” the electron cloud is  No electric field In the presence of an electric field produces an induced dipole moment

Rayleigh Scattering 1000 2000 3000 4000 Rayleigh scattering is elastic and is indicated at zero wavenumbers Can be a calibration aid if visible in the spectrum Low Density Polyethylene Wavenumbers (cm-1)

Raman Scattering Rayleigh scattering is elastic 3 Rayleigh Scattering Stokes Shift Anti-Stokes Shift 100 200 300 -300 -200 -100 Raman Shift (cm-1) Intensity Lowest excited electronic state 2 1 Virtual states Anti-Stokes DE Stokes Rayleigh scattering is elastic Stokes and anti-Stokes scattering are inelastic Stokes lines are more probable and therefore used most often Anti-Stokes lines are not affected by fluorescence and occur more frequently at higher temperatures Excitation Rayleigh Scattering 3 Ground electronic state DE 2 1 More probable Less probable

Application Areas Pharmaceuticals Food Science Particulate Characterization Process Monitoring (PAT) Authentication Method Development Polymorphism Grain Studies Polymers Crystallinity Homogeneity Earth Sciences Geology Mineralogy Semiconductors Phase Determination Inclusion Detection Biology Medical Applications Reaction Monitoring Bacteria Characterization Sensory Receptors Cell Monitoring Forensics Fibers Paints Questioned Documents Controlled Substances Building Materials Terrorism Consumer Products Particulate Contamination Quality Control

Raman Instrumentation Source Sample Illumination Spectrometer Typically laser source Raman intensity increases as the fourth power of source frequency Raman signal is independent of laser wavelength Longer wavelength sources tend to cause less laser induced fluorescence Common Lasers High frequency = Low wavelength = Higher Raman intensity Low frequency = High wavelength = Lower Raman intensity

Raman Instrumentation Source Sample Illumination Spectrometer Confocal Set Up Detector Pinhole Aperture Typically commercially available microscope platforms Typically confocal configuration Laser Spot sizes in 2-10 mm range Barrier Filter Out of Focus Light Rays In Focus Light Rays Dichroic Mirror Laser Objective Pinhole Aperture Band Pass Filter Focal Planes Sample

Raman Instrumentation Source Sample Illumination Spectrometer Widefield Set Up Detector Typically commercially available microscope platforms Typically confocal configuration Laser Spot sizes in 50-500 mm range Barrier Filter Out of Focus Light Rays In Focus Light Rays Dichroic Mirror Laser Objective Pinhole Aperture Band Pass Filter Focal Planes Sample

Raman Instrumentation Source Sample Illumination Spectrometer Dispersive Spectrometer Fourier Transform Spectrometer Focusing Mirror Collimating Mirror Detector Collimating Mirror Dispersive Grating Focusing Mirror Spatial Filter Dielectric Filters Scattered Light from Sample Scattered Light from Sample Focusing Mirror Detector

Raman Instrumentation Raman Microprobe End On View of Probe Spectrometer Input Fibers Fiber Optic Cable Collection Fibers Focusing Objective Probe End On View of Collection Fibers going to Spectrometer Slit Laser Sample

Sample Preparation Very little sample preparation needed Solids, liquids and gasses can be analyzed Gasses and liquids can be analyzed through a suitable container Non-volatile liquids can be spotted onto a substrate provided slight evaporation is not critical Samples not encompassing the entire laser spot should be placed on a suitable substrate Aluminum is usually used as a substrate since it does not produce Raman information and does not produce fluorescence Gold substrates can also be used Quartz microscope slides produce a minimal amount of background fluorescence Unsuitable Receptacle Too little sample in receptacle, focal plane does not reach material Suitable Receptacle Sufficient amount of sample, focal plane reaches material

Analytical Comparison Raman vs. Infrared