EMLAB 1 Chapter 9. Steady-state power analysis. EMLAB 2 Contents 1.Instantaneous Power: For the special case of steady state sinusoidal signals 2.Average.

Slides:



Advertisements
Similar presentations
Since Therefore Since.
Advertisements

Chapter 12 Three Phase Circuits
Sinusoidal Steady-State Power Calculations
CH5 AC circuit power analysis 5.1 Instantaneous Power 5.2 Average Power 5.3 Effectives values of Current & Voltage 5.4 Apparent Power and Power Factor.
Alternating Current Circuits
The average ac power (P av ) is the power dissipated on the load resistor. 0  cos  1, dependent on the complex load. ideal power factor: cos  =1,
Filter & Transfer Function Z1Z1 Z2Z2 V in V out To determine filter type, look how H V as a function of frequency Z 1 and Z 2 could include multiple components.
AC Power Discussion D9.3 Chapter 5. Steady-State Power Instantaneous Power Average Power Effective or RMS Values Power Factor Complex Power Residential.
Steady-State Sinusoidal Analysis
AC Power: average power
Copyright © 2013 The McGraw-Hill Companies, Inc. Permission required for reproduction or display. 1 Chapter 11 AC Circuit Power Analysis.
Storey: Electrical & Electronic Systems © Pearson Education Limited 2004 OHT 16.1 Power in AC Circuits  Introduction  Power in Resistive Components 
Power Factor and Power Factor Correction
AC POWER ANALYSIS Tunku Muhammad Nizar Bin Tunku Mansur
LOGO LINEAR CIRCUIT ANALYSISSAJID HUSSAIN QAZI MEHRAN U.E.T, KHAIRPUR CAMPUS A.C POWERS AND POWER FACTOR.
Chapter 7 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
ECE 3183 – Chapter 5 – Part D CHAPTER 5 - D1 ECE 3183 – EE Systems Chapter 5 – Part D AC Power, Power Factor.
ENGR-43_Lec-09-2_Complex_Power.ppt 1 Bruce Mayer, PE Engineering-43: Engineering Circuit Analysis Bruce Mayer, PE Registered Electrical.
ECE 2300 Circuit Analysis Dr. Dave Shattuck Associate Professor, ECE Dept. Lecture Set #24 Real and Reactive Power W326-D3.
Chapter 17 Power in AC Circuits.
AC POWER ANALYSIS Tunku Muhammad Nizar Bin Tunku Mansur
Alexander-Sadiku Fundamentals of Electric Circuits
Fundamentals of Electric Circuits Chapter 11
Chapter 22 Alternating-Current Circuits and Machines.
AC Circuits (Chapt 33) circuits in which the currents vary in time
Chapter 11 AC Power Analysis
Chapter 31 Electromagnetic Oscillations and Alternating Current Key contents LC oscillations, RLC circuits AC circuits (reactance, impedance, the power.
Electromagnetic Oscillations and Alternating Current
Chapter 11 AC Steady-State Power
Fundamentals of Electric Circuits Chapter 11
Power in AC Circuits ELEC 308 Elements of Electrical Engineering
ENGR-43_Lec-09-3_1-Ph_3W_Power.ppt 1 Bruce Mayer, PE Engineering-43: Engineering Circuit Analysis Bruce Mayer, PE Licensed Electrical.
STEADY-STATE POWER ANALYSIS
EGN 3373 Introduction to Electrical Systems I A Systems Approach to Electrical Engineering Graphics Adapted from “Physical, Earth, and Space Science”,
Chapter 5 Steady-State Sinusoidal Analysis. 1. Identify the frequency, angular frequency, peak value, rms value, and phase of a sinusoidal signal. 2.
1 1. Power and RMS Values. 2 Instantaneous power p(t) flowing into the box Circuit in a box, two wires +−+− Circuit in a box, three wires +−+− +−+− Any.
1 Chapter 11 AC Power Analysis 電路學 ( 二 ). 2 AC Power Analysis Chapter Instantaneous and Average Power 11.2Maximum Average Power Transfer 11.3Effective.
AC POWER ANALYSIS Instantaneous & Average Power
Chapter 7 AC Power Analysis
EMLAB Polyphase circuits. EMLAB 2 1. Three Phase Circuits Advantages of polyphase circuits 2. Three Phase Connections Basic configurations for three.
1 1. Power and RMS Values. 2 Instantaneous power p(t) flowing into the box Circuit in a box, two wires +−+− Circuit in a box, three wires +−+− +−+− Any.
Chapter 11 AC Power Analysis
Power System Fundamentals EE-317 Lecture 3 06 October 2010.
1 Lecture #9 EGR 272 – Circuit Theory II Read: Chapter 10 in Electric Circuits, 6 th Edition by Nilsson Chapter 10 - Power Calculations in AC Circuits.
Chapter 17 Power in AC Circuits.
1 ELECTRICAL TECHNOLOGY EET 103/4  Define and explain sine wave, frequency, amplitude, phase angle, complex number  Define, analyze and calculate impedance,
Chapter 10 Sinusoidal Steady- State Power Calculations
Slide 1Fig 33-CO, p Slide 2Fig 33-1, p the basic principle of the ac generator is a direct consequence of Faraday’s law of induction. When.
ELECTRICA L ENGINEERING Principles and Applications SECOND EDITION ALLAN R. HAMBLEY ©2002 Prentice-Hall, Inc. Chapter 5 Steady-State Sinusoidal Analysis.
ECE 7800: Renewable Energy Systems Topic 2: Fundamentals of Electric Power Spring 2010 © Pritpal Singh, 2010.
AC POWER ANALYSIS. 2 Content Average Power Maximum Average Power Transfer Complex Power Power Factor Correction.
EKT103 ELECTRICAL ENGINEERING
Diode rectifiers (uncontrolled rectifiers)
FUNDAMENTAL OF ELECTRICAL POWER SYSTEMS (EE 270)
1 Chapter 3 AC Power Analysis. 2 AC Power Analysis Chapter 3 3.1Instantaneous and Average Power 3.2Maximum Average Power Transfer 3.3Effective or RMS.
Chapter 13 The Basic Elements and Phasors. Objectives Be able to add and subtract sinusoidal voltages or currents Use phasor format to add and subtract.
Power in AC Circuits Introduction Power in Resistive Components
Chapter 11 AC Power Analysis
Chapter 11 AC Power Analysis
Chapter 11 AC Power Analysis
Sinusoidal Excitation of Circuits
EFFECTIVE OR RMS VALUES
Neutral current is zero
STEADY-STATE POWER ANALYSIS
Power in AC Circuits Introduction Power in Resistive Components
Electromechanical Systems
Chapter 31 Electromagnetic Oscillations and Alternating Current
ELL100: INTRODUCTION TO ELECTRICAL ENGG.
The instantaneous power
Engineering Circuit Analysis
Presentation transcript:

EMLAB 1 Chapter 9. Steady-state power analysis

EMLAB 2 Contents 1.Instantaneous Power: For the special case of steady state sinusoidal signals 2.Average Power : Power absorbed or supplied during one cycle 3.Maximum Average Power Transfer :When the circuit is in sinusoidal steady state 4.Effective or RMS Values : For the case of sinusoidal signals 5.Power Factor : A measure of the angle between current and voltage phasors 6.Power Factor Correction : How to improve power transfer to a load by “aligning” phasors 7.Complex Power : Measure of power using phasors 8.Single Phase Three-Wire Circuits : Typical distribution method for households and small loads

EMLAB 3 1. Instantaneous power Net power transfer is positive! Net power transfer is zero!

EMLAB 4 Power vs. voltage

EMLAB 5 2. Average power If voltage and current are in phase If voltage and current are in quadrature Purely inductive or capacitive

EMLAB 6 Example 9.2 Find the average power absorbed by impedance  15,60,53.3,10 ivMM IV 

EMLAB 7 Example 9.3 Determine the average power absorbed by each resistor, the total average power absorbed and the average power supplied by the source

EMLAB 8 3. Effective or rms Values Definition is valid for ANY periodic signal with period T root mean square

EMLAB 9 Compute rms value of the voltage waveform Example

EMLAB Complex power ; Average power ; Complex power ; Average power

EMLAB 11 Example Evaluate the average power consumed by the following circuit.

EMLAB Maximum average power transfer

EMLAB 13 Maximum average power transfer condition

EMLAB 14 Example Find Z L for maximum average power transfer. Compute the maximum average power supplied to the load.

EMLAB Power factor Instantaneous power in an ac circuit. Positive p represents power to the load; negative p represents power returned from the load. Power to a purely resistive load. The peak value of p is V m I m.

EMLAB 16 Power to a purely capacitive load. Average power is zero. Power to a purely inductive load. Energy stored during each quarter cycle is returned during the next quarter-cycle. Average power is zero.

EMLAB 17 Power factor ☆ The reference phase angle is that of voltage. A leading or lagging phase angle is the state that the phase angle of current is leading or lagging behind that of voltage. ( 전압의 위상을 기준으로 하여 전류의 위상이 lead 인지 lag 인지 결정됨.) Power factorPhase difference (θ v - θ i ) Q (Complex power) leading -- Capacitive in phase 00 Resistive lagging ++ Inductive

EMLAB 18 Transmission line

EMLAB 19

EMLAB 20 Electric company 전기 회사 Electric company 전기 회사 House 가정 +-+- 계량기 Power meter Z 전선에 의한 손실을 줄이기 위해서 가능한 전류를 적게 흘려야 한다. To save power losses due to resistance of transmission lines, current should be kept as small as possible. Transmission line loss 220V

EMLAB W 220V W 110V Example

EMLAB 22 An industrial load consumes 88 kW at a pf of lagging from a 480-V rms line. The transmission line resistance from the power company’s transformer to the plant is Let us determine the power that must be supplied by the power company (a) under present conditions and (b) if the pf is somehow changed to 0.90 lagging. (It is economically advantageous to have a power factor as close to one as possible.) Example 9.10 (a) (b)

EMLAB 23 Example A load operates at 20 kW, 0.8 pf lagging. The load voltage is at 60 Hz. The impedance of the line is j0.3. We wish to determine the voltage and power factor at the input to the line.

EMLAB Power factor correction Simple approach to power factor correction Industrial load with lagging pf Electrical source

EMLAB 25 Example

EMLAB Single-phase three wire circuits

EMLAB kW 100V (rms) Disadvantage of single phase two wire system ( 단상 2 선 식의 단점 ) 1.If the load increases to 2kW, P loss becomes 40W. 2.If each wire can sustain heat only to 5W power loss, the cross-section area should increase 4 times, whereby cost for copper wires increase 4 times. 100V (rms) kW 100V (rms)

EMLAB kW 100V (rms) kW 100V (rms) 1.Although the power load increases to 2kW, P loss remains 10W. 2.With 2 times power load, only one copper wire is added. Single-phase 3 wire circuits

EMLAB 29

EMLAB 30 Example 9.27 A light-duty commercial single-phase three-wire 60-Hz circuit serves lighting, heating, and motor loads, as shown below. Lighting and heating loads are essentially pure resistance and, hence, unity power factor (pf), whereas motor loads have lagging pf. Unbalanced connection

EMLAB 31 Balanced connection

EMLAB 32 이행선 Safety considerations Average effect of 60Hz current from hand to hand and passing the heart Required voltage depends on contact, person and other factors Typical residential circuit with ground and neutral Ground conductor is not needed for normal operation

EMLAB 33 Grounding is needed to protect from lightning. Grounding for safety considerations

EMLAB 34 기기 고장에 의한 short

EMLAB 35 Increased safety due to grounding When switched on the tool case is energized without the ground connector the user can be exposed to the full supply voltage! Conducting due to wet floor If case is grounded then the supply is shorted and the fuse acts to open the circuit More detailed numbers in a related case study Example

EMLAB 36 Ground prong removed Suggested resistances for human body Wet skin Can cause ventricular fibrillation