Sensor Systems for CPI Sensor Transmitter temperature sensors

Slides:



Advertisements
Similar presentations
Industrial Instrumentation
Advertisements

PID Implementation Issues
1 An Overview of Process Instrumentation CM4110 Unit Operations Lab October 2008.
OFFLINE COMPOSITION MEASURING SENSORS
Chapter 9 PID Tuning Methods.
Unit Operation Lab K S Chou Ch E, N T H U 1. A: Fluid Flow Experiments A1 - Friction Coefficient in Tubes A2 - Flowmeters  Types of flowing fluid: gas.
Control Loop Hardware and Troubleshooting
Control System Instrumentation
Competition Other types of flow meters Thermal Mass flow competition.
Chapter 3 Dynamic Modeling.
Chapter 10 Control Loop Troubleshooting. Overall Course Objectives Develop the skills necessary to function as an industrial process control engineer.
CHE 185 – PROCESS CONTROL AND DYNAMICS
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Closed Conduit Measurement Techniques  Pipeline systems  Transmission lines  Pipe.
Hydraulics.
Washington University ChE 433 Digital Process Control Laboratory
Making Physical Measurements Terry A. Ring Department of Chemical Engineering University of Utah 22 August 2005.
Flow Measurement.
Fluid mechanics 3.1 – key points
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Closed Conduit Measurement Techniques ä Pipeline systems ä pipe networks ä measurements.
FLOW METER SELECTION SEMINAR
Control System Instrumentation
On-Line Physical Measurements Terry A. Ring Department of Chemical Engineering University of Utah.
Flow Measurement M. Shahini.
1 Syafruddin Hasan. 2 Systems Concepts Automated systems that control flow rates or volume employ the following components: Automated systems that control.
1 Anayet Karim. 2 Course Evaluation Test 1Test 1 Test 2Test 2 Assignment 1Assignment 1 Assignment 2Assignment 2 Lab ModuleLab Module Final ExamFinal Exam.
Process Variables and Sensors. Parts and materials needed for today (instructor will provide): DP transmitters Thermocouples Filled-bulb temperature sensor.
1 Syafruddin Hasan. 2 Systems Concepts Automated systems that control flow rates or volume employ the following components: Automated systems that control.
Flow Sensors.
CBE 150A – Transport Spring Semester 2014 Flow Measurement and Control.
CHE 185 – PROCESS CONTROL AND DYNAMICS OPTIMIZATION AND PRIMARY LOOP ELEMENTS.
Pressure Measurement Why is it important?. Pressure Measurement Asses the situation –What is the range of pressures to be measured? –Is pressure dynamic.
Classification of Instruments :
Chemical Engineering 3P04 Process Control Tutorial # 2 Learning goals 1.The feedback cause-effect principle 2. Key element in the loop: The control valve.
Chapter 7 PID Control.
Week 1 Unit Conversions Mass and Volume Flow Ideal Gas Newtonian Fluids, Reynolds No. Week 2 Pressure Loss in Pipe Flow Pressure Loss Examples Flow Measurement.
Gas and Liquid Metering. Why Metering? Measuring flow rate and cumulative volume Selling System Control Losses detection Reservoir outlets Pumping stations.
Lease Automatic Custody Transfer
Cascade, Ratio, and Feedforward Control
Wedge Flow Element 1.
Instrument Training Material
Chemical Engineering 3P04
Flow Measurement Muhajir Ab. Rahim School of Mechatronic Engineering
Temperature Control Loop
Level and Pressure Measurement Christopher Foot Patrick Lawlor.
CHAPTER 9 Control System Instrumentation
SIZING PNEUMATIC SYSTEMS. Introduction Pneumatic systems are sized to meet output power requirements. The air distribution system is sized to carry the.
Process Control Priyatmadi Pengantar Pengendalian Proses Priyatmadi Jurusan teknik Elektro FT UGM.
Flow Measurement and Control. Orifice Meter The orifice meter consists of an accurately machined and drilled plate concentrically mounted between two.
Making Physical Measurements Terry A. Ring Department of Chemical Engineering University of Utah.
Improved Precision Leading to Improved Energy Efficiency Edward Decker AE 790 – Intelligent Buildings June 6, 2006.
Flow Measurement and Control
1 Gas Lift. 2 Several Installations StarPac Flow Calculation & StarTalk.
Week 1 Unit Conversions Conservation of Mass Ideal Gas Newtonian Fluids, Reynolds No. Pressure Loss in Pipe Flow Week 2 Pressure Loss Examples Flow Measurement.
CHAPTER 9 Control System Instrumentation
Micro Motion, Inc. Gas Measurement.
Standards Certification Education & Training Publishing Conferences & Exhibits Automation Connections ISA EXPO 2006.
UNDERSTANDING DIFFERENT
INTRODUCTION TO ELECTRONIC INSTRUMENTATION
Actuator Edi Leksono Department of Engineering Physics
Sensors and Detectors - 1
Control System Instrumentation
Instrumentation Malfunctions, Test Review - Agenda
PEF3006 Process Control Fall 2017 Sensors By Finn Haugen
Making Physical Measurements
Making Physical Measurements
Spirax Sarco Orifice Plate System
August 23, 2000 R.N. Dubois Dow Chemical
Dynamic Behavior of Ideal Systems
Control System Instrumentation
Presentation transcript:

Sensor Systems for CPI Sensor Transmitter temperature sensors flow sensors level sensors pressure sensors composition analyzers Transmitter

The Control Relevant Aspects of Sensors The time constant/deadtime of the sensor The repeatability of the sensor

Sensor Terminology Span Zero Accuracy Repeatability Process measurement dynamics Calibration

Span and Zero Example Consider a case in which the maximum temperature that is to be measured is 350ºF and the minimum temperature is 100ºF. Then the zero is 100ºF and the span is 250ºF In addition, if the measured temperature is known at two different sensor output levels (i.e., ma’s), the span and zero can be calculated directly.

Smart Sensors Sensors with onboard microprocesssors that offer a number of diagnostic capabilities. Smart pH sensors determine when it is necessary to trigger a wash cycle due to buildup on the electrode surface. Smart flow meters use statistical techniques to check for plugging of the lines to the DP cell. Smart temperature sensors use redundant sensors to identify drift and estimate expected life before failure.

Temperature Sensing Systems RTDs and thermistors are an order of magnitude more precise but are less rugged and cost more than thermocouples (TC’s). Typical dynamic response time constant is 6-20 seconds for RTDs, thermistors and TC’s. Additional thermal resistance on inside or on the outside of the thermal well can result in an excessively slow responding temperature measurement.

Pressure Measurements Usually based on mechanical balance bars Very fast measurement dynamics Repeatability less than ±0.1%

Flow Measurements Orifice plate/DP cell most common approach. Good repeatability and fast dynamic response. Magnetic flow meters and vortex shedding flow meters are also used in certain situations. They are more expensive but more reliable and require less maintenance. A straight run of pipe required for good accuracy for all flow meters.

Orifice Plate/DP Cell Flow Indicator in a Flow Control Loop

Paddle Type Orifice Plate

Sizing an Orifice for a Differential Pressure Flow Indicator b is the ratio of the orifice diameter to the pipe diameter. 0.2 < b < 0.7 Pressure drop at minimum flow should be greater than 0.5 psi. Pressure drop across the orifice should be less than 4% of the line pressure. Choose the maximum value of b that satisfies each of the above specifications.

Vortex Shedding Meters A blunt object is placed in the flow path and the frequency of turbulent oscillations correlates with the flow rate. Useful for clean low viscosity liquids and gases. Ensure that cavitation does not occur in the measuring zone.

Example of a Vortex Shedding Meter

Magnetic Flow Meters Based on measuring the current generated by the flow a conducting fluid through a magnetic field. Have low pressure drop associated with them. Are applied to conductive fluid (tap water is conductive enough) Deposition on the electrodes is a limitation. See picture in text.

Example of a Magnetic Flow Meter

Bottom Line on Flow Meters Magnetic flow meters and vortex shedding flow meters require less maintenance and are generally more reliable than orifice plate flow meters BUT they are much more expensive.

Level Sensors Usually based on the hydrostatic head in a vessel measured by the differential pressure. Has a repeatability of about ±1% with a time constant less than 1 second. Level measurements based upon a float or x-rays are also used in special situations.

Typical Differential Pressure Level Measurement

Analyzer Sensor Systems GC- most common composition analyzer. Based on plug flow of a volatile sample through a packed bed-behaves as deadtime. Deadtime and repeatability depend on the particular components being measured. Radiation absorption- infrared, ultraviolet, and visible. Can be effective for certain components. Sample system can affect dynamics and reliability of composition measurement.

Bio-Sensors

Common Bio-Sensors Flow measurements: Coriolis meters and rotameters. Off-gas analyzers: mass spectrometers (one mass spec can provide online measurements for up to 32 bio-reactors), O2 electrode for O2 concentration and infrared spectrometer for CO2 concentration. Fermentation product analysis: HPLC and FIA

Common Bio-Sensors Ion-specific electrodes pH sensor DO sensor Redox sensors

Schematic of an Ion-Specific Electrode

Table 2.3 Lists the control-relevant aspects of actuators and sensors in the CPI and bio-tech industries: Time constant Valve deadband or repeatability Turndown ratio, rangeability, or range

Overall Course Objectives Develop the skills necessary to function as an industrial process control engineer. Skills Tuning loops Control loop design Control loop troubleshooting Command of the terminology Fundamental understanding Process dynamics Feedback control