Measuring Frequency The amplitude of an electrical signal represents height and is measured in volts. The period is the amount of time to complete one.

Slides:



Advertisements
Similar presentations
EP301 COMPUTER NETWORKING SYSTEM
Advertisements

Cisco CCNA Sem 1 Chapter 4 Cable Testing, Cabling LAN’s and WAN’s
Cable Testing.
SUNY Ulster Cisco Semester 1 Unit 4 – Cable Testing K. Wick CCAI.
CCNA 1 v3.1 Module 4 Cable Testing. Purpose of This PowerPoint This PowerPoint primarily consists of the Target Indicators (TIs) of this module in CCNA.
DCN286 Introduction to Data Communication Technology Session 5.
1 Transmission Fundamentals Chapter 2 (Stallings Book)
ECE 4321: Computer Networks Chapter 3 Data Transmission.
Testing.
Chapter 3 Data and Signals
Oct-03 ©Cisco Systems CCNA Semester 1 Version 3 Comp11 Mod4 – St. Lawrence College – Cornwall Campus, ON, Canada – Clark slide 1 Cisco Systems CCNA Version.
Department of Electronic Engineering City University of Hong Kong EE3900 Computer Networks Data Transmission Slide 1 Continuous & Discrete Signals.
Network+ Guide to Networks, Fourth Edition Chapter 3 Transmission Basics and Networking Media.
William Stallings Data and Computer Communications 7th Edition (Selected slides used for lectures at Bina Nusantara University) Data, Signal.
Module 3.0: Data Transmission
1 Version 3.0 Module 4 Cable Testing. 2 Version 3.0 Waves Networking professionals are interested in voltage waves on copper media, light waves in optical.
Copyright CCNA 1 Chapter 4, Part 1 Cable Testing By Your Name.
CCNA 1 v3.0 Module 4 Cable Testing. Purpose of This PowerPoint This PowerPoint primarily consists of the Target Indicators (TIs) of this module in CCNA.
4 Semester 1 CHAPTER 4 REVIEW JEOPARDY Presented by: Terren L. Bichard.
CCNA 1 Module 4: Cable Testing.
1 Semester 1 Module 4 Cable Testing Andres, Wen-Yuan Liao Department of Computer Science and Engineering De Lin Institute of Technology
Noise and SNR. Noise unwanted signals inserted between transmitter and receiver is the major limiting factor in communications system performance 2.
Electronics and Signals Chapter 4. Parts of an Atom nucleus - the center part of the atom, formed by neutrons and protons nucleus - the center part of.
思科网络技术学院理事会. 1 OSI Physical Layer Network Fundamentals – Chapter 8.
DCN286 INTRODUCTION TO DATA COMMUNICATION TECHNOLOGY Network Cable Testers and Tests.
Cisco 1 - Networking Basics Perrine. J Page 19/3/2015 Chapter 3 Which of the following correctly describes the type of signal that the network media carries?
Lecture 2 Most basic facts from Electricity needed for understanding telecommunications Local transmission lines in the telephone system Decibels Signals.
Mod 4 – Cable Testing CCNA 1.
Chapter 2.  Types of Network  Circuit Switched & Packet Switched  Signaling Techniques  Baseband & Broadband  Interference  Transmission Medium.
1 Business Telecommunications Data and Computer Communications Chapter 3 Data Transmission.
1 CCNA SEMESTER 1 V 3.0 CHAPTER 4 – Cable testing.
1 Electronics & Signals Honolulu Community College Cisco Academy Training Center Semester 1 Version
NESCOT CATC1 Cable Testing CCNA 1 v3 – Module 4. NESCOT CATC2 Waves 1. The _________ of the waves is the amount of time between each wave, measured in.
1 CISCO NETWORKING ACADEMY PROGRAM (CNAP) SEMESTER 1/ MODULE 4 Cable Testing.
CE 4228 Data Communications and Networking
Physical Transmission
Computer Communication & Networks
ECEN 621, Prof. Xi Zhang ECEN “ Mobile Wireless Networking ” Course Materials: Papers, Reference Texts: Bertsekas/Gallager, Stuber, Stallings,
Networking Fundamentals Copper Core Cable as Network Media.
Cisco 1 - Networking Basics Perrine. J Page 110/16/2015 Chapter 4 Which of the following best describes a digital signal? 1.A sine wave of normal shape.
Copper Media Describe the specifications and performances of different types of cable. Describe coaxial cable and its advantages and disadvantages over.
Bits (0s and 1s) need to be transmitted from one host to another. Each bit is placed on the cable as an electrical signal or pulse. On copper cable the.
CCNA 1 Module 4 Cable Testing. 2 Waves Frequency: Frequency: –the number of waves per second Period: Period: –the amount of time that it takes to complete.
Sep-03 ©Cisco SystemsCCNA Semester 1 Version 3 Comp11 Mod4 – St. Lawrence College – Cornwall Campus – Clark slide 1.
CCNA 1 v3.0 Module 4 Cable Testing. Objectives Waves.
Physical Layer PART II. Position of the physical layer.
Electromagnetic Spectrum
1. Physical Transmission Transmission Media Wire (guided) Coaxial cable Twisted Pair UTP STP Fiber Optic Wireless (unguided) Radio waves Microwave Infrared.
CCNA1 v3 Module 4 v3 CCNA 1 Module 4 JEOPARDY S Dow.
Lecture Focus: Data Communications and Networking  Transmission Impairment Lecture 14 CSCS 311.
Cisco CCNA Semester 1 Chapter 4 V3.0 By: Terren L. Bichard.
Cisco Semester 1 Chapter 4 Slides Cable Testing
Module 4 Cable Testing.
1 3. Data Transmission. Prof. Sang-Jo Yoo 2 Contents  Concept and Terminology  Analog and Digital Data Transmission  Transmission Impairments  Asynchronous.
Lesson 2—Networking BASICS1 Networking BASICS Network Media Unit 1 Lesson 2.
Network Media. Copper, Optical, Fibre (Physical Layer Technologies) Introduction to Computer Networking.
TOPIC 1.2 INTRODUCTION TO NETWORKING. OBJECTIVES By the end of the topic, students should be able to: a) List the elements of data communication systems.
Attenuation is the loss of signal strength, for example, when cables exceed a maximum length. This means that a 1 bit voltage signal loses amplitude as.
By: Thomas Olivotti.  PSNEXT stands for Power Sum Near End Crosstalk and is calculated by transmitting a signal down each wire pair in turn and summing.
Chapter 2 : Data Communications BENG 4522 Data Communications & Computer Networks Transmission Impairment Signals travel through the transmission.
Chapter Four Networking Media. Chapter Objectives  Explain concepts related to data transmission and noise  Describe the physical characteristics of.
Computer Communication & Networks
Pertemuan 10 Signal & Noise
Module 4 Cable Testing.
James Chen Module 4: Cable Testing James Chen 2018/11/10 Yuda college of business.
Physical Transmission
CCNA 1 version 3.0 Rick Graziani Cabrillo College
CCNA 1 v3.1 Module 4 Cable Testing
CCNA 1 v3.1 Module 4 Cable Testing
Introduction Analog and Digital Signal
Presentation transcript:

Measuring Frequency The amplitude of an electrical signal represents height and is measured in volts. The period is the amount of time to complete one cycle, measured in seconds. The frequency is the # of complete cycles per second, measured in Hertz.

Exponents & Logarithms In networking, there are three important number systems: Base 2 – binary Base 10 – decimal Base 16 – hexadecimal One way to work with the very large and very small numbers that occur in networking is to use logarithms. While the study of logarithms is beyond the scope of this course, the terminology is used commonly in calculating decibels, a way of measuring signals on copper, optical, and wireless media.

Exponents & Logarithms In networking, there are three important number systems: Base 2 – binary Base 10 – decimal Base 16 – hexadecimal One way to work with the very large and very small numbers that occur in networking is to use logarithms. While the study of logarithms is beyond the scope of this course, the terminology is used commonly in calculating decibels, a way of measuring signals on copper, optical, and wireless media.

Decibels The decibel (dB) is a measurement unit important in describing networking signals. There are two formulas for calculating decibels: dB = 10 log10 (P final / Pref ) dB = 20 log10 (V final / V reference ) The variables represent the following values: dB measures the loss or gain of the power of a wave. Decibels are usually negative numbers representing a loss in power as the wave travels, but can also be positive values representing a gain in power if the signal is amplified Log 10 implies that the number in parenthesis will be transformed using the base 10 logarithm rule P final is the delivered power measured in Watts P ref is the original power measured in Watts V final is the delivered voltage measured in Volts V reference is the original voltage measured in Volts

Noise Noise is an important concept in communications systems, including LANS. While noise usually refers to undesirable sounds, noise related to communications refers to undesirable signals. All communications systems have some amount of noise. Even though noise cannot be eliminated, its effects can be minimized if the sources of the noise are understood. There are many possible sources of noise: Nearby cables which carry data signals Radio frequency interference (RFI) which is noise from other signals being transmitted nearby Electromagnetic interference (EMI), which is noise from nearby sources such as motors and lights Laser noise at the transmitter or receiver of an optical signal Noise that affects all transmission frequencies equally is called white noise. Noise that only affects small ranges of frequencies is called narrowband interference.

Bandwidth Bandwidth is an extremely important concept in communications systems. Two ways of considering bandwidth that are important for the study of LANs are analog bandwidth and digital bandwidth. Analog Bandwidth typically refers to the frequency range of an analog electronic system. Analog bandwidth could be used to describe the range of frequencies transmitted by a radio station. Its units of measurement is Hertz, the same as the unit of frequency. Digital Bandwidth measures how much information can flow from one place to another in a given amount of time. The fundamental unit of measurement for digital bandwidth is bits per second (bps). Physical media, current technologies, and the laws of physics limit bandwidth. During cable testing, analog bandwidth is used to determine the digital bandwidth of a copper cable. Analog frequencies are transmitted from one end and received on the opposite end. The two signals are then compared, and the amount of attenuation of the signal is calculated.

Signals Over Copper Cabling On copper cable, data signals are represented by voltage levels that represent binary ones and zeros. The voltage levels are measured with respect to a reference level of zero volts at both the transmitter and the receiver. This reference level is called the signal ground. It is important that both transmitting and receiving devices refer to the same zero volt reference point. When they do, they are said to be properly grounded.

Signaling Over Fiber Optic Cabling Fiber optic cable is used to transmit data signals by increasing and decreasing the intensity of light to represent binary ones and zeros. The strength of a light signal does not diminish like the strength of an electrical signal does over an identical run length. Optical signals are not affected by electrical noise, and optical fiber does not need to be grounded. Therefore, optical fiber is often used between buildings and between floors within the building. As costs decrease and demand for speed increases, optical fiber may become a more commonly used LAN media.

Attenuation & Insertion Loss on Copper Media Attenuation is the decrease in signal amplitude over the length of a link. Attenuation is expressed in decibels (dB) using negative numbers. Smaller negative dB values are an indication of better link performance. Impedance is a measurement of the resistance of the cable to alternating current (AC) and is measured in ohms. The normal, or characteristic, impedance of a Cat5 cable is 100 ohms. If a connector is improperly installed on Cat5, it will have a different impedance value than the cable. This is called an impedance discontinuity or an impedance mismatch. Impedance discontinuities cause attenuation because a portion of a transmitted signal will be reflected back to the transmitting device rather than continuing to the receiver, much like an echo. The combination of the effects of signal attenuation and impedance discontinuities on a communications link is called insertion loss.

Sources of Noise on Copper Media Noise is any electrical energy on the transmission cable that makes it difficult for a receiver to interpret the data sent from the transmitter. TIA/EIA-568-B certification of a cable now requires testing for a variety of types of noise. Crosstalk involves the transmission of signals from one wire to a nearby wire. Twisted-pair cable is designed to take advantage of the effects of crosstalk in order to minimize noise. In twisted-pair cable, a pair of wires is used to transmit one signal. The wire pair is twisted so that each wire experiences similar crosstalk. Because a noise signal on one wire will appear identically on the other wire, this noise be easily detected and filtered at the receiver. Twisting one pair of wires in a cable also helps to reduce crosstalk of data or noise signals from adjacent wires.

Types of Crosstalk There are three distinct types of crosstalk: Near-end Crosstalk (NEXT) Far-end Crosstalk (FEXT) Power Sum Near-end Crosstalk (PSNEXT)

Near-end Crosstalk (NEXT) Near-end crosstalk (NEXT) is computed as the ratio of voltage amplitude between the test signal and the crosstalk signal when measured from the same end of the link.

Far-end Crosstalk (FEXT) Due to attenuation, crosstalk occurring further away from the transmitter creates less noise on a cable than NEXT. This is called far-end crosstalk, or FEXT. The noise caused by FEXT still travels back to the source, but it is attenuated as it returns. Thus, FEXT is not as significant a problem as NEXT.

Power Sum Near-end Crosstalk Power Sum NEXT (PSNEXT) measures the cumulative effect of NEXT from all wire pairs in the cable. PSNEXT is computed for each wire pair based on the NEXT effects of the other three pairs. The combined effect of crosstalk from multiple simultaneous transmission sources can be very detrimental to the signal.

Cable Testing Standards The TIA/EIA-568-B standard specifies ten tests that a copper cable must pass if it will be used for modern, high-speed Ethernet LANs: Wire map Insertion loss Near-end crosstalk (NEXT) Power sum near-end crosstalk (PSNEXT) Equal-level far-end crosstalk (ELFEXT) Power sum equal-level far-end crosstalk (PSELFEXT) Return loss Propagation delay Cable length Delay skew

Ethernet Standards The Ethernet standard specifies that each of the pins on an RJ-45 connector have a particular purpose. A NIC transmits signals on pins 1 & 2, and it receives signals on pins 3 & 6.

Remember… A straight-thru cable has T568B on both ends. A crossover (or cross-connect) cable has T568B on one end and T568A on the other. A console cable had T568B on one end and reverse T568B on the other, which is why it is also called a rollover cable.

Wiring Faults

Time Based Parameters Propagation delay is a simple measurement of how long it takes for a signal to travel along the cable being tested. The delay in a wire pair depends on its length, twist rate, and electrical properties. Delays are measured in hundredths of nanoseconds. One nanosecond is one-billionth ( ) of a second. The TIA/EIA-568-B standard sets a limit for propagation delay for the various categories of UTP. The delay difference between pairs is called the delay skew.

A New Standard On June 20, 2002, the Category 6 (or Cat 6) addition to the TIA-568 standard was published. The official title of the standard is ANSI/TIA/EIA-568-B.2-1. Although the tests for certifying Cat 6 are essentially the same as those specified by the Cat 5 standard, Cat 6 cable must pass the tests with higher scores to be certified. Cat6 cable must be capable of carrying frequencies up to 250 MHz and must have lower levels of crosstalk and return loss.