P M V Subbarao Professor Mechanical Engineering Department

Slides:



Advertisements
Similar presentations
FLOW measurements.
Advertisements

Chapter 2 Introduction to Heat Transfer
Aero-Hydrodynamic Characteristics
Advanced Artificial Lift Methods Electrical Submersible Pump Advanced Artificial Lift Methods – PE 571 Chapter 1 - Electrical Submersible Pump Centrifugal.
Thermo-energy audit Services for thermo-energy audit Flow measurement.
Aerofoil as A Turbine Blade
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Closed Conduit Measurement Techniques  Pipeline systems  Transmission lines  Pipe.
Chapter 16 Wave Motion.
Engineering H191 - Drafting / CAD The Ohio State University Gateway Engineering Education Coalition Lab 4P. 1Autumn Quarter Transport Phenomena Lab 4.
1 MFGT 242: Flow Analysis Chapter 4: Governing Equations for Fluid Flow Professor Joe Greene CSU, CHICO.
Volume Flow Measurements. Obstruction Meters u Orifice Meters u Venturi Meters u Flow Nozzles.
Flow Measurement.
California State University, Chico
Forces Acting on a Control Volume Body forces: Act through the entire body of the control volume: gravity, electric, and magnetic forces. Surface forces:
Fluid mechanics 3.1 – key points
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Closed Conduit Measurement Techniques ä Pipeline systems ä pipe networks ä measurements.
Unit 3 - FLUID MECHANICS.
Flow Measurement M. Shahini.
Chapter Five Flow Measurement
1 Syafruddin Hasan. 2 Systems Concepts Automated systems that control flow rates or volume employ the following components: Automated systems that control.
1 Anayet Karim. 2 Course Evaluation Test 1Test 1 Test 2Test 2 Assignment 1Assignment 1 Assignment 2Assignment 2 Lab ModuleLab Module Final ExamFinal Exam.
1 Syafruddin Hasan. 2 Systems Concepts Automated systems that control flow rates or volume employ the following components: Automated systems that control.
Flow Sensors.
Module 3 Fluid Flow. Lesson 20 CONTINUITY EQUATION DESCRIBE how the density of a fluid varies with temperature. DEFINE the term buoyancy. DESCRIBE the.
MODULE V.
Flow Measurements Identify an effect that depends on flowrate
Temperature Measurement
Gas and Liquid Metering. Why Metering? Measuring flow rate and cumulative volume Selling System Control Losses detection Reservoir outlets Pumping stations.
Rudolf Žitný, Ústav procesní a zpracovatelské techniky ČVUT FS 2010 Flowrate Experimental methods E EXM5 Some pictures and texts were copied from.
Instructor: Lichuan Gui
FREE CONVECTION Nazaruddin Sinaga Laboratorium Efisiensi dan Konservasi Energi Jurusan Teknik Mesin Universitas Diponegoro.
Hydrostatics: Fluids at Rest. applying Newtonian principles to fluids hydrostatics—the study of stationary fluids in which all forces are in equilibrium.
Instrument Training Material
Flow Measurement Muhajir Ab. Rahim School of Mechatronic Engineering
Lecture 2 Single Phase Flow Concepts
Measurement of flowing fluids
Enhancement of Heat Transfer P M V Subbarao Associate Professor Mechanical Engineering Department IIT Delhi Invention of Compact Heat Transfer Devices……
Flow Measurement and Control. Orifice Meter The orifice meter consists of an accurately machined and drilled plate concentrically mounted between two.
PTT 204/3 APPLIED FLUID MECHANICS SEM 2 (2012/2013)
CE 1501 CE 150 Fluid Mechanics G.A. Kallio Dept. of Mechanical Engineering, Mechatronic Engineering & Manufacturing Technology California State University,
Chapter 14 Fluids What is a Fluid? A fluid, in contrast to a solid, is a substance that can flow. Fluids conform to the boundaries of any container.
Reynolds Transport Theorem We need to relate time derivative of a property of a system to rate of change of that property within a certain region (C.V.)
Flow Measurement and Control
Chapter 14 Fluids.
Convection in Flat Plate Boundary Layers P M V Subbarao Associate Professor Mechanical Engineering Department IIT Delhi A Universal Similarity Law ……
1 Linear Wave Equation The maximum values of the transverse speed and transverse acceleration are v y, max =  A a y, max =  2 A The transverse speed.
NNPC FSTP ENGINEERS Physics Course Code: Lesson 7.

Thermo-aero Dynamic Analysis of Wind Turbines P M V Subbarao Professor Mechanical Engineering Department Development of Characteristic Design Variables.
Measurements in Fluid Mechanics 058:180 (ME:5180) Time & Location: 2:30P - 3:20P MWF 3315 SC Office Hours: 4:00P – 5:00P MWF 223B-5 HL Instructor: Lichuan.
Flow of Compressible Fluids. Definition A compressible flow is a flow in which the fluid density ρ varies significantly within the flowfield. Therefore,
Chapter 12 Compressible Flow
Heat Transfer Su Yongkang School of Mechanical Engineering # 1 HEAT TRANSFER CHAPTER 6 Introduction to convection.
Phil. U., M Eng Dep., Measurements, Chap#7 flow measurements is very important as it covers wide ranges of applications. The flow rate measurement devices.
Momentum Equation and its Applications
An Angular velocity Transducers: Inductive Transducer: Inductive transducers may be either the self-generating or the passive type. The self-generating.
S.N. PATEL INSTITUTE OF TECHNOLOGY AND RESEARCH CENTER TOPIC : MEASURMENT OF FLOW GUIDED BY : Mr. Nirav Raykundaliya 1 Sr. no. NamePEN 1Kaliyani Vishal
HELICOPTER AERODYNAMICS
Mathematics to Innovate Blade Profile P M V Subbarao Professor Mechanical Engineering Department Also a Fluid Device, Which abridged the Globe into Global.
1 Sensors and Transducers. 2 Physical Process Measurand Signal variable Display X S Measurement M Simple Instrument Model Physical Measurement variable.
UNDERSTANDING DIFFERENT
PRESENTATION ON MEASUREMENT OF FLUID VELOCITY Submitted by:  Prativa Giri (072bme628)  Sutishna Pokharel(072bme646)
INTRODUCTION TO ELECTRONIC INSTRUMENTATION
The rate of change of velocity.
BME 312 BIOMEDICAL INSTRUMENTATION II LECTURER: ALİ IŞIN
Betz Theory for A Blade Element
اندازه گیری جریان سیال.
Identification of Fundamental Design Parameter for A Wind Turbine
Dual Induction theory for Wind Turbines
Eulerization of Betz theory: Wind Turbines
Presentation transcript:

P M V Subbarao Professor Mechanical Engineering Department Measurement of Flow P M V Subbarao Professor Mechanical Engineering Department An Essential Requirement in CV Based Industrial Appliances….

Mathematics of Flow Rate The Scalar Product of two vectors, namely velocity and area..

Important characteristics of the dot product The first point to note about the definition is that the coordinate system does not enter the definition. The second point to note is that because cosq=cos(-q), the order is not important, that is, the scalar product is commutative. The scalar product is also distributive. All these qualities help in development of a single instrument to measure the scalar product.

Types of Flow Measurement Technologies Variable Area (rotameters) Rotating Vane (paddle & turbine) Positive Displacement Differential Pressure Vortex Shedding Thermal Dispersion Magnetic Magnetic Thermal Mass Coriolis Mass Ultrasonic

Some Facts About Variable Area Flowmeters Called “float type float type”, “rotameter’’, or “variable area” flowmeters. By far the most common specified, purchased, and installed flowmeter in the world

Variable Area Flowmeters Fluid flow moves the float upward against gravity. Float will find equilibrium when area around float generates enough drag equal to weight - buoyancy. Some types have a guide rod to keep float stable. Low Cost (pricing usually starts < $50) Simple Reliable Design Can Measure Liquid or Gas Flows Tolerates Dirty Liquids or Solids in Liquid

Measuring Principles of Variable Area Flowmeters Flow Rate Analysis. The forces acting on the bob lead to equilibrium between: the weight of the bob rbgVb acting downwards the buoyancy force rgVb and the drag force Fd acting upwards. Where Vb is the volume and rb is the density of the bob, r is the density of the fluid, and g is the gravitational acceleration:

The drag force results from the flow field surrounding the bob and particularly from the wake of the bob. In flow analyses based on similarity principles, these influences are accounted for by empirical coefficient CL or CT in the drag law for:

The volume flow rate through the rotameter is: Where m is the open area ratio, defined as: And D is the tube diameter at the height of the bob.

for laminar flow: where the parameter a is defined in terms of a constant K =Vb/D3b characteristic of the shape of the bob: for turbulent flow:

With either laminar or turbulent flow through the rotameter, the flow rate is proportional to m. If the cross-sectional area of the tube is made to increase linearly with length, i.e., then since the cone angle f of the tube is small, and the flow rate is directly proportional to the height h of the bob. h

Similarity Analysis. The basic scaling parameter for flow is the Reynolds number, defined as: where UIN is the velocity at the rotameter inlet, and the tube diameter D is represented by its value at the inlet, equal to the bob diameter Db. Through the Reynolds number regimes of laminar or turbulent flow, and particularly important for the rotameter flow regimes with strong or weak viscosity dependence can be distinguished. It has been found to be practical for rotameters to use an alternative characteristic number, the Ruppel number, defined as:

where mb = rbD3b is the mass of the bob. By combining Equations, the mass flow through the rotameter can be written as: The relationship between the Ruppel number and the Reynolds number: The advantage of the Ruppel number is its independence of the flow rate. Since the Ruppel number contains only fluid properties and the mass and the density of the bob, it is a constant for a particular instrument.

Design Charts for Laminar Rotameters

Design Charts for Turbulent Rotameters

End fitting — flange shown; flowmeter body; rotation pickup — magnetic, reluctancetype shown; permanent magnet; pickup cold wound on pole piece; rotor blade; rotor hub; Rotor shaft bearing — journal type shown; rotor shaft; diffuser support and flow straightener; diffuser; (12) flow conditioning plate (dotted) — optional with some meters.

Theory There are two approaches described in the current literature for analyzing axial turbine performance. The first approach describes the fluid driving torque in terms of momentum exchange, while the second describes it in terms of aerodynamic lift via airfoil theory. The former approach has the advantage that it readily produces analytical results describing basic operation, some of which have not appeared via airfoil analysis. The latter approach has the advantage that it allows more complete descriptions using fewer approximations. However, it is mathematically intensive and leads rapidly into computer-generated solutions.

Eliminating the time dimension from the left-hand-side quantity reduces it to the number of rotor rotations per unit fluid volume, which is essentially the flowmeter K factor specified by most manufacturers.

In the ideal situation, the meter response is perfectly linear and determined only by geometry. In some flowmeter designs, the rotor blades are helically twisted to improve efficiency. This is especially true of blades with large radius ratios, (R/a). If the flow velocity profile is assumed to be flat, then the blade angle in this case can be described by tan b = Constant X r. This is sometimes called the “ideal” helical blade. In practice, there are instead a number of rotor retarding torques of varying relative magnitudes. Under steady flow, the rotor assumes a speed that satisfies the following equilibrium:

The difference between the actual rotor speed, rw, and the ideal rotor speed, rwi , is the rotor slip velocity due to the combined effect of all the rotor retarding torques , and as a result of which the fluid velocity vector is deflected through an exit or swirl angle, q. Denoting the radius variable by r, and equating the total rate of change of angular momentum of the fluid passing through the rotor to the retarding torque, one obtains: NT is the total retarding torque

Industrial Correlations for Frictional Losses

Electromagnetic Flowmeters Magnetic flowmeters have been widely used in industry for many years. Unlike many other types of flowmeters, they offer true noninvasive measurements. They are easy to install and use to the extent that existing pipes in a process can be turned into meters simply by adding external electrodes and suitable magnets. They can measure reverse flows and are insensitive to viscosity, density, and flow disturbances. Electromagnetic flowmeters can rapidly respond to flow changes and they are linear devices for a wide range of measurements. As in the case of many electric devices, the underlying principle of the electromagnetic flowmeter is Faraday’s law of electromagnetic induction. The induced voltages in an electromagnetic flowmeter are linearly proportional to the mean velocity of liquids or to the volumetric flow rates.

As is the case in many applications, if the pipe walls are made from nonconducting elements, then the induced voltage is independent of the properties of the fluid. The accuracy of these meters can be as low as 0.25% and, in most applications, an accuracy of 1% is used. At worst, 5% accuracy is obtained in some difficult applications where impurities of liquids and the contact resistances of the electrodes are inferior as in the case of low-purity sodium liquid solutions. Faraday’s Law of Induction This law states that if a conductor of length l (m) is moving with a velocity v (m/s–1), perpendicular to a magnetic field of flux density B (Tesla), then the induced voltage e across the ends of conductor can be expressed by:

The velocity of the conductor is proportional to the mean flow velocity of the liquid. Hence, the induced voltage becomes:

Ultrasonic Flowmeters There are various types of ultrasonic flowmeters in use for discharge measurement: (1) Transit time: This is today’s state-of-the-art technology and most widely used type. This type of ultrasonic flowmeter makes use of the difference in the time for a sonic pulse to travel a fixed distance. First against the flow and then in the direction of flow. Transmit time flowmeters are sensitive to suspended solids or air bubbles in the fluid. (2) Doppler: This type is more popular and less expensive, but is not considered as accurate as the transit time flowmeter. It makes use of the Doppler frequency shift caused by sound reflected or scattered from suspensions in the flow path and is therefore more complementary than competitive to transit time flowmeters.

Principle of transit time flowmeters.

Transit Time Flowmeter Principle of Operation The acoustic method of discharge measurement is based on the fact that the propagation velocity of an acoustic wave and the flow velocity are summed vectorially. This type of flowmeter measures the difference in transit times between two ultrasonic pulses transmitted upstream t21 and downstream t12 across the flow. If there are no transverse flow components in the conduit, these two transmit times of acoustic pulses are given by:

Since the transducers are generally used both as transmitters and receivers, the difference in travel time can be determined with the same pair of transducers. Thus, the mean axial velocity along the path is given by:

Example The following example shows the demands on the time measurement technique: Assume a closed conduit with diameter D = 150 mm, angle f = 60°, flow velocity = 1 m/s, and water temperature =20°C. This results in transmit times of about 116 s and a time difference Dt =t12 – t21 on the order of 78 ns. To achieve an accuracy of 1% of the corresponding full-scale range, Dt has to be measured with a resolution of at least 100 ps (1X10–10s). Standard time measurement techniques are not able to meet such requirements so that special techniques must be applied. Digital timers with the state-of-the –art Micro computers will make it possible to measure these time difference.

Point Velocity Measurement Pitot Probe Anemometry : Potential Flow Theory & Bernoulli’s Theory . Thermal Anemometry : Newton’s Law of Cooling. Laser Anemometry: Doppler Theory.