Powered Air-Purifying Respirator (PAPR) Copyright © 2015 by The S.E.A. Group.

Slides:



Advertisements
Similar presentations
Using the SASS 3010 Particle Extractor
Advertisements

Filter Changing Procedures For TEOM Series 1400ab and Model 8500 FDMS (B & C Types)
CBRNE Training Academy
Equipment for Assembly Fluke Multimeter 115 True RMS Glue Ring Jig Flathead screwdriver 60 Watt desk lamp HIOS Cl 4000 Electric screw driver Anti-static.
NORTH POWERED AIR-PURIFYING RESPITATOR (PAPR) INSTRUCTIONS FOR USE Preventive Medicine Industrial Hygiene Service.
Powered Air Purifying Respirator (PAPR) Infection Control Unit.
Sanders and Sanding Safety
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Ice. Pure and Simple ™ Welcome to the Ice-O-Matic ® on-line training modules.
2 Fire Fighter Qualifications and Safety Skill Drills.
TESTING Dräger PSS 7000 Breathing Apparatus GENERAL TEST
Used with FILTERS Copyright © 2013 by The S.E.A. Group.
Used with FILTERS Copyright © 2013 by The S.E.A. Group.
Troubleshooting Guide. Table of Contents 2 Shower Filter 3 Leak Between Top Housing & Filter4 Leak Between Swivel Collar & Housing5 Leak at Top of Swivel.
Technical support provided by: Highly Pathogenic Avian Influenza Control Programme SOP Use and Maintenance of High Pressure Washer Machine Market chain.
Installation. Indoor Unit Installation Typical Installation.
Supplied-air hood Copyright © 2013 by The S.E.A. Group.
Technical support provided by: Highly Pathogenic Avian Influenza Control Programme SOP Use and Maintenance of High Pressure Washer Machine Market chain.
Copyright 2008 Kenneth M. Chipps Ph.D. How to Terminate a Corning Unicam Connector Last Update
DR-2000 Customer Benefits Security; Tamper resistant programming protects your customer and you! Low maintenance, long battery life & long squeeze tube.
860 21/2”-10”. Modification Overview  Production of the 2½” – 10 sizes began in  Lead free version (LF860) was introduced in Parts do not.
ResQmax Line Deployment Kit -ResQmax Launcher- 5 nozzle protectors -2 Streamline Projectiles- O-ring kit -500’ 3mm line with container- Corrosion block.
If you use your computer more than a few hours per day, we suggest you not to turn off your computer at the end of the day. Instead turn off only the.
Bullard PA20 Powered Air Purifying Respirator (PAPR) Training Material
Clean Air Box Usage & Care CABs RAMs CO Monitors.
Copyright © 2013 by The S.E.A. Group. A particle filter can be fitted to the front of a gas filter. Copyright © 2013 by The S.E.A. Group Make a combination.
Suction Pumps.
Electronics Merit Badge Class 4 5/17/2015Electronics Merit Badge Class National Scout Jamboree1.
1 InnoSys Quick Connect End Effecter Service and Maintenance Procedures Nov. 19, 2007 Rev. B.
Marubot Football League Service Manual.
Supplied-air regulator Copyright © 2013 by The S.E.A. Group.
Powered Air-Purifying PARTICLE Respirator (PAPR) Copyright © 2013 by The S.E.A. Group.
Copyright © 2013 by The S.E.A. Group Powered Air-Purifying Respirator for particles (Particle PAPR)
Powered Air-Purifying Respirator
Supplied-air regulator Copyright © 2013 by The S.E.A. Group.
FILTERING MDP. Safety and Safety Gear  When filtering from a fermentation vessel you should never use carbon dioxide to push the beer through the filter,
1. The 3M manufactures 2 types of Powered Air Purifying Respirator (PAPR) to be worn to provide respiratory protection for those staff members who have.
Copyright © 2015 by The S.E.A. Group. AIR SOURCE: Minimum of impurities Never above hygiene limit levels Less than 0.3 mg/m³ oil No water condensation...prepare.
Copyright © 2013 by The S.E.A. Group Supplied-air regulator.
Copyright © 2013 by The S.E.A. Group Supplied-air regulator.
VITAL SIGNS: T, P, R, & BP.
1 Engine Cooling Systems R. Bortignon. 2 Cooling Systems During the power stroke, temperatures of 1200°C or more are generated by the burning air/fuel.
Respirator Safety This Training Covers Respirator Inspection User Fit Checks Respirator Cleaning Respirator Storage.
Installation. Indoor Unit Installation Typical Installation.
Instructions for Printing Fluid Power Task Cards Print slides 2-5 and then take to a copy machine to make double sided copies Copy slide 2 to the front.
Removing and Replacing the Battery Cover 1. Ensure the phone is turned off. 2. Press the Battery cover locker; lift the battery cover up and away from.
825, 825Y, 825YD 21/2”-10”. Modification Overview  825- ( ) Cast iron body- Threaded in seats- Internal check parts are epoxy coated iron. Old.
Scene Shop and Electricity Safety
Introduction to Soldering
PUBLIC SAFETY INSTRUCTIONS
LF866 2½”-10”. Product Overview  Production of the 2½” – 10” sizes began in  The LF866 utilizes a Type 2 bypass (Model LF619 single check).
Write down three safety rules we talked about in the past few days. Talk with someone near you and see how many ways are out there to lift a car for service.
1 InnoSys Quick Connect End Effecter Service and Maintenance Procedures Shreveport Assembly 14 MAY, 2008.
007 (M1,M2,M3) ½”-2” 007 (M1,M2,M3) ½”-2”. Modification Overview- 007  007 ¾-1” ( ) 1½ -2” ( ) ½” (1993-Current)  007M1 ¾-1” ( )
009 (M3) ½”-2” 009 (M3) ½”-2”. Modification Overview- 009  009 ¾-1” ( ) (1” ) ¾-1” ( ) (1” ) 1¼ -2” ( ) 1¼.
Build A Motor You must follow the directions step-by-step!
Select your System Freedom Micro DI.
Copyright © 2016 by The S.E.A. Group
Quantifit Controlled Negative Pressure Fit Test Protocol
Respiratory Protection Training
Service Procedure For Changing Engine Oil And An Oil Filter
826YD 21/2”-10”.
Motorized Miter Saw.
Installing the SIM CARD and Battery
Call to Fix Epson Printer Error Code 0x97
Fire Safety Presentation at
Part 2 – Supplied-air Respirators
Copyright © 2016 by The S.E.A. Group
880V 21/2”-10”.
709 3/4”-2”.
Presentation transcript:

Powered Air-Purifying Respirator (PAPR) Copyright © 2015 by The S.E.A. Group

CHECK: Respirator and all parts are clean and intact Know how to use the equipment...prepare for first-time use

Copyright © 2015 by The S.E.A. Group...prepare for first-time use ACTIVATE & RECHARGE BATTERY: Open battery lock Slide battery out of fan unit

Remove the plastic sticker covering the terminals Copyright © 2015 by The S.E.A. Group...prepare for first-time use

Copyright © 2015 by The S.E.A. Group The electric socket is covered by a protective rubber tab that can be folded back to expose the socket....prepare for first-time use

Plug in the battery charger to a wall socket and to the battery Copyright © 2015 by The S.E.A. Group...prepare for first-time use

Charger indicator light Do not unplug until GREEN Copyright © 2015 by The S.E.A. Group...prepare for first-time use CHARGING 80% DONE

Always recharge BEFORE drained Don’t try to recharge other batteries Don’t use other chargers Recharge indoors Don’t cover — overheating risk No liquids or moisture No contact with metal objects Don’t try to take apart Keep away from naked flame Copyright © 2015 by The S.E.A. Group...maintain the battery

Copyright © 2015 by The S.E.A. Group...assemble the SR500 BELT: Turn unit upside down Fit the three tongues into the slot Push until ‘wing’ snaps into position Repeat with other attachment Make sure plastic ‘wings’ are pointing downwards with fan unit upside down

...assemble the SR500 Check O-ring at end of hose Copyright © 2015 by The S.E.A. Group

...assemble the SR500 Check the O-ring at the end of hose Line up lugs with slots in bayonet fitting Copyright © 2015 by The S.E.A. Group

...assemble the SR500 Check the O-ring at the end of hose Line up lugs with slots in bayonet fitting Insert the hose, then turn clockwise until it locks into position (about 1/8 of a turn) Copyright © 2015 by The S.E.A. Group

...assemble the SR500 Copyright © 2015 by The S.E.A. Group If using the SR500 with the SR200 full face mask, screw the free end of the breathing hose into the face piece

...fit particle filters Only PARTICLE filters can be fitted to the filter adapters Pre-filters MUST be used Copyright © 2015 by The S.E.A. Group

Filter adapters are needed for particle filters Press a particle filter onto the filter adapter until it snaps into position Repeat with second particle filter Copyright © 2015 by The S.E.A. Group...fit particle filters

Copyright © 2015 by The S.E.A. Group...fit particle filters Screw the assembled filter adapters with the particle filters to the threads in the fan unit

Place a pre-filter into each pre-filter holder Copyright © 2015 by The S.E.A. Group...fit particle filters

Snap the pre-filter holders with pre-filters to the front of each main filter on the fan unit Copyright © 2015 by The S.E.A. Group...fit particle filters

Insert a coin (or similar) between filter rim and filter adapter Twist apart Copyright © 2015 by The S.E.A. Group …remove filters from adapters

Screw two identical gas filters directly into the fan unit Copyright © 2015 by The S.E.A. Group …fit gas filters

If you are using gas filters, a particle filter must be fitted to the front of each gas filter Copyright © 2015 by The S.E.A. Group

Place a pre-filter into each pre-filter holder Copyright © 2015 by The S.E.A. Group …fit gas filters

Snap the pre-filter holders with pre-filters to the front of each main filter on the fan unit Copyright © 2015 by The S.E.A. Group …fit gas filters

…operate the fan unit Single button operation Press once to start fan Watch the display Copyright © 2015 by The S.E.A. Group

…operate the fan unit Fan motor starts Self-test >Lights< >Beeper< >Vibrator< When finished, only the ‘small fan’ symbol is lit (normal operation) Copyright © 2015 by The S.E.A. Group

…operate the fan unit Press button once more to enter BOOST mode (big fan symbol) Press again to go back to NORMAL mode (small fan symbol) Copyright © 2015 by The S.E.A. Group

…operate the fan unit PRESS AND HOLD to turn fan unit off Copyright © 2015 by The S.E.A. Group

DIP IN AIR FLOW Stop work Keep wearing respirator Move to safe area Inspect and fix PAPR Copyright © 2015 by The S.E.A. Group …recognise alarms

CLOGGED PARTICLE FILTER Stop work Keep wearing respirator Move to safe area Replace particle filters Copyright © 2015 by The S.E.A. Group …recognise alarms

…read the battery charge More than 70% charge 50–70% charge Copyright © 2015 by The S.E.A. Group 20–50% charge 5–20% charge (prepare to leave area)

VERY LOW BATTERY Stop work immediately Keep wearing respirator Move quickly to safe area Recharge battery Copyright © 2015 by The S.E.A. Group …read the battery charge

Make sure the SR500, headpiece and filters are intact and correctly assembled Switch on the PAPR Copyright © 2015 by The S.E.A. Group …do a functional test

Place the entire headpiece or face-piece into the test bag and seal off by closing your hand around both the bag and the breathing hose IMPORTANT! Do not in any way obstruct, squeeze together or bend the breathing hose Copyright © 2015 by The S.E.A. Group …do a functional test

With the other hand, hold the flow tube up vertically from the bag Copyright © 2015 by The S.E.A. Group …do a functional test

The floating ball in the tube should be on the 175 l/min line or slightly above it Copyright © 2015 by The S.E.A. Group …do a functional test 175 l/min

If the floating ball is not on or above the line, shake it a few times and make sure the tube is completely vertical Copyright © 2015 by The S.E.A. Group …do a functional test

If the floating ball is not on or above the line, shake it a few times and make sure the tube is completely vertical Copyright © 2015 by The S.E.A. Group …do a functional test

If functional check is unsuccessful, call supervisor Do not use the equipment Copyright © 2015 by The S.E.A. Group …do a functional test

Keep the headpiece sealed in the test bag Block off the exhaust of the test flow tube with your thumb or hand Copyright © 2015 by The S.E.A. Group …check the alarms

>Light< >Beeper< >Vibrator< Copyright © 2015 by The S.E.A. Group …check the alarms

Release the blockage All alarms should stop after 15 seconds Copyright © 2015 by The S.E.A. Group …check the alarms

If the alarm check is unsuccessful, call supervisor Do not use the equipment Copyright © 2015 by The S.E.A. Group …check the alarms

Fan unit in the small of the back Copyright © 2015 by The S.E.A. Group …wear the SR500 PAPR

If using a headpiece, let breathing hose run straight up back No kinks, no bends Copyright © 2015 by The S.E.A. Group …wear the SR500 PAPR

If using SR200 full face mask, run breathing hose around waist and up along chest Copyright © 2015 by The S.E.A. Group …wear the SR500 PAPR

Normal cleaning & disinfection: use Sundström cleaning tissues Copyright © 2015 by The S.E.A. Group …clean the SR500 PAPR

Heavier cleaning: Mild detergent Warm water Soft cloth or sponge Copyright © 2015 by The S.E.A. Group …clean the SR500 PAPR

Thank you for watching Copyright © 2015 by The S.E.A. Group