Forward Detectors and Measurement of Proton-Antiproton Collision Rates by Zachary Einzig, Mentor Michele Gallinaro INTRODUCTION THE DETECTORS EXPERIMENTAL.

Slides:



Advertisements
Similar presentations
Kathleen Chinetti Sohaila Mali Calibrating Equipment for the Direct Detection of Dark Matter using Noble Element. Scintillation.
Advertisements

Neutrinos from kaon decay in MiniBooNE Kendall Mahn Columbia University MiniBooNE beamline overview Kaon flux predictions Kaon measurements in MiniBooNE.
COSMIC RAY MUON DETECTION USING SCINTILLATION COUNTER AND WAVELENGTH SHIFTING FIBERS ARUNODAYA BHATTACHARYA VSRP-2009,TIFR,MUMBAI 6/7/09.
Introduction Secondary electron secondary electron detector The electron beam interaction with near surface specimen atoms will make a signal which results.
Introduction This project used cosmic rays to test a prototype Minimum Bias Trigger Scintillator (MBTS) that will be used in the ATLAS experiment at CERN.
Shantanu Menon Thomas Irons Michael Jacoutot. Cosmic Rays  High energy particles (mainly protons) from outer space.  Have up to 10 million times more.
Ultra Peripheral Collisions at RHIC Coherent Coupling Coherent Coupling to both nuclei: photon~Z 2, Pomeron~A 4/3 Small transverse momentum p t ~ 2h 
A Muon Veto for the Ultra-Cold Neutron Asymmetry Experiment Vince Bagnulo LANL Symposium 2006 Outline ● UCNA Experiment ● Muon background ● Proposed Veto.
Introduction into LS theory and practice. Agenda  Energy deposition  Overview of the LSC process  Theory of operation  Quenching  Machine  Uses.
SANE S pin A symmetries of the N ucleon E xperiment SEEN THROUGH THE EYES OF JOHN GERMAN MASTERS STUDENT FROM NORTH CAROLINA A&T STATE UNIVERSITY. JUNE.
A Muon Veto for the Ultra Cold Neutron Asymmetry Experiment Vince Bagnulo with Dr. Jeff Martin Electrons Ultra Cold Neutrons Cosmic Ray Muons Protons Pions.
Design and First Results of a Cosmic Ray Telescope For Use In Testing a Focusing DIRC M. P. Belhorn University of Cincinnati The BELLE group at the University.
Cosmic Rays Basic particle discovery. Cosmic Rays at Earth – Primaries (protons, nuclei) – Secondaries (pions) – Decay products (muons, photons, electrons)
An accelerator beam of muon neutrinos is manufactured at the Fermi Laboratory in Illinois, USA. The neutrino beam spectrum is sampled by two detectors:
CRAnE: A JAS-based Data Acquisition System for Cosmic Rays Jennifer Docktor & Manuel Reyes Mentors Tom Glanzman & Willy Langeveld August 13, 2003 Department.
Detecting Cosmic Rays An inexpensive portable detector By: Danny Franke Quarknet 2004.
MICE: The International Muon Ionization Cooling Experiment Diagnostic Systems Tracker Cherenkov Detector Time of Flight Counters Calorimeter Terry Hart.
Y. Karadzhov MICE Video Conference Thu April 9 Slide 1 Absolute Time Calibration Method General description of the TOF DAQ setup For the TOF Data Acquisition.
Timing Properties of T0 Detectors At PHOBOS Saba Zuberi, Erik Johnson, Nazim Khan, Frank Wolfs, Wojtek Skulski University of Rochester.
Preliminary Results of the Test Run at SLAC Petra Hüntemeyer.
M.Gallinaro, ``Innovative Particle and Radiation Detectors’’, Siena, October slide 1 The CDF MiniPlug Calorimeter Forward Physics Conceptual.
Abstract We constructed and tested seven scintillation counters using photomultiplier tubes, in order to create a fast electronic coincidence “trigger”
ZEUS Calorimeter (1) At HERA high energetic electrons (e) collide with high energetic protons (P). The ZEUS detector measures the properties of the particles.
Lecture 11  Production of Positron Emitters, Continued  The Positron Tomograph.
Jimmy McCarthy International Cosmic Ray Day 26 th September 2012 Detecting Cosmic Rays.
1 Light Collection  Once light is produced in a scintillator it must collected, transported, and coupled to some device that can convert it into an electrical.
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
Printed by The River Falls Cerebral Muon Sensor Project David Schick, James Anderson, Seth Matucheski, Elizabeth Denkinger University.
Dominik Wermus (Virginia Military Institute, Lexington, VA 24450), Doug Higinbotham (Thomas Jefferson National Accelerator Facility, Newport News, VA,
Tools for Nuclear & Particle Physics Experimental Background.
QuarkNet Muon Data Analysis with Shower Array Studies J.L. FISCHER, A. CITATI, M. HOHLMANN Physics and Space Sciences Department, Florida Institute of.
Scintillators, DAQ boards, and PMTs Getting Familiarized With the Equipment By Melissa Sussmann and Alex Bonnifield.
Cosmic Rays: Ever Present and Useful Anthony Gillespie Denbigh High School Mentor: Dr. Douglas Higinbotham Cosmic Rays Using the Cosmic Rays Current Research.
14/02/2007 Paolo Walter Cattaneo 1 1.Trigger analysis 2.Muon rate 3.Q distribution 4.Baseline 5.Pulse shape 6.Z measurement 7.Att measurement OUTLINE.
FLC Group Test-beam Studies of the Laser-Wire Detector 13 September 2006 Maximilian Micheler Supervisor: Freddy Poirier.
Energy Distribution of Cosmic Ray Muons Paul Hinrichs With David Lee Advised by Phil Dudero.
Thomas Jefferson National Accelerator Facility Page 1 EC / PCAL ENERGY CALIBRATION Cole Smith UVA PCAL EC Outline Why 2 calorimeters? Requirements Using.
Status of the NO ν A Near Detector Prototype Timothy Kutnink Iowa State University For the NOvA Collaboration.
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
QuarkNet July 2010 Najla Mackie & Tahirah Murphy.
Neutron Beam Intensity for the Spallation Neutron Source Beamline 13: The NPDGamma Experiment Analysis and Results Jeremy Stewart University of Tennessee.
Ian Ross Rose-Hulman Institute of Technology Mentor: Dr. Richard Teuscher University of Toronto ATLAS Group ATLAS Calorimetery: Cosmic Ray Commissioning.
Luminosity Monitor UKNF Meeting 7 June 2010 Paul Soler, David Forrest Danielle MacLennan.
Seeing the Subatomic Stephen Miller Saturday Morning Physics October 11, 2003.
MINERvA Main INjector ExpeRiment for -A is the symbol for the neutrino. The beam that is sent to MINERvA is made out of neutrinos. In chemistry, an A stands.
Elastic Scattering and Diffraction at DØ Tamsin Edwards for the DØ collaboration 14 th - 18 th April, 2004 XII International Workshop on Deep Inelastic.
Experimental Nuclear Physics Some Recent Activities 1.Development of a detector for low-energy neutrons a. Hardware -- A Novel Design Idea b. Measure the.
Brian Lowery July 11,  Primary  From space ▪ Lower energy cosmic rays come from sun ▪ Higher energy cosmic rays come from other places in the.
QuarkNet and Cosmic Ray Muon Flux Experiments Florida Academy of Sciences Spring Conference 2009 Alfred Menendez and Michael Abercrombie with Dr. Marcus.
F Don Lincoln, Fermilab f Fermilab/Boeing Test Results for HiSTE-VI Don Lincoln Fermi National Accelerator Laboratory.
Lecture 12  Last Week Summary  Sources of Image Degradation  Quality Control  The Sinogram  Introduction to Image Processing.
TOF detector in PHENIX experiment PHENIX time-of-flight counter The PHENIX time-of-flight (TOF) counter serves as a particle identification device for.
The photomultiplier tubes selection for KM2A electromagnetic particle detectors (EDs) hou chao IHEP The 2nd workshop of air shower detection at high altitudes.
1 Methods of PSD energy calibration. 2 Dependence of energy resolution on many factors Constant term is essential only for energy measurement of single.
Synthesis of plastic scintillator and applications Ildefonso León Monzón Universidad Autónoma de Sinaloa Centro de Investigación y de Estudios Avanzados.
ICARUS T600: low energy electrons
Muon Lab Theory Muons (standard model) Cosmic rays Life time
“Performance test of a lead glass
The Effect of Artificial Lighting on a Cosmic Ray Detector
MoNA detector physics How to detect neutrons. Thomas Baumann NSCL.
Panagiotis Kokkas Univ. of Ioannina
PAN-2013: Radiation detectors
Status of the TOF Detector
Cosmic Ray Showers Cosmic ray activity Figure 3:
Scintillation Counter
Detecting Cosmic Rays An inexpensive portable detector
Photomultiplier (PMT) Tubes
The Measurement of Forward Particle Production in LHC
The Top Quark Search Joey Foley.
Presentation transcript:

Forward Detectors and Measurement of Proton-Antiproton Collision Rates by Zachary Einzig, Mentor Michele Gallinaro INTRODUCTION THE DETECTORS EXPERIMENTAL SETUP ACKNOWLEDGEMENTS The Tevatron collider at Fermilab accelerates protons (p) and antiprotons (  p) in opposite directions. The proton beam and the antiproton beams are squeezed together at two points: CDF and D0. It is at these interaction points that collisions occur. When a head-on collision takes place, the energies of the proton and antiproton are available to make a variety of particles with high transversal momentum and which are tracked by several detectors surrounding the interaction point. The CDF detector at Fermilab. The scintillator is a plastic doped with a material that is easily excited by a charged particle. When the charged particle traverses the scintillator, it excites an electron, which then drops back to a normal state and releases a photon. Many photons are produced by one charged particle. The scintillator is attached to a light guide which transports the photons produced in the scintillator to the PMT. Light (photons) that enters one end is internally reflected to the other end with high efficiency. Photons arriving from the light guide are focused onto the PMT photocathode. Upon arrival, a photon knocks out an electron. The electrons are multiplied through a series of dynodes in the PMT. A voltage is applied to the PMT and distributed to the dynodes to create a gradient. The electrons travel down the gradient releasing more electrons every time they hit a dynode. Top Counter Bottom Counter Test Counter Computer INTERACTION POINT coincidence We test our counters by seeing how they respond to charged particles. For this purpose cosmic rays are used. The top and bottom counter serve as triggers, selecting muons from cosmic rays. When a muon goes through the counter, the signal is carried to the discriminator. When there is a coincidence between top and bottom counters (because of a muon) the discriminator opens the gate. Whenever the gate is open, the computer records the signal from the test counter through an analog-to-digital converter (ADC). The ADC measures the charge of the signal (the conversion is 0.25 pc/ADC count). ADC Dr. Michele Gallinaro Professor Professor Konstantin Goulianos Outreach Program D RESULTS ADC spectrum for one of the counters tested. The response of the detector is recorded by the ADC and the spectrum analyzed with the program ROOT. The position (MPV) and the width (sigma) of the peak corresponding to a minimum ionizing particle (MIP) traversing the detectors is studied. The position of the MIP peak is proportional of the gain of the PMT.The events at low ADC counts represent the background (pedestal). CONCLUSIONS MIP peak position at different PMT voltages. Each detector may have different gain at the same voltage; however, it is important to have uniformity among the BSC detectors. This graph shows how the position of the MIP peak changes with voltage (HV). Therefore, by adjusting the HV it is possible to equalize the counters response and thus have a uniform response. I have studied different characteristics of the BSC detectors, assembled them, and evaluated their performances. I made several graphs of MIP peak position, MIP peak vs. voltage and compared them. Though the points differ, the slopes are consistent within the uncertainty. This means that although the specific gains of the PMTs are different, the way they react to increasing voltages is the same. From the ADC spectra, it is possible to conclude that the BSC detectors are able to give a clear separation between signal and background when a muon is passing through it. The signal is well above the background noise and the trigger level can be set above the pedestal to only select particles traversing the detectors. A study of the performance of the BSC detectors installed at CDF to measure the beam loss and proton-antiproton collision rates was conducted. The beam loss provides a quality control of the data-taking at the Tevatron and at CDF. The beam loss is measured by timing the signals appropriately, before the collisions occurs. A linear response of the coincidence rate with the instantaneous luminosity indicates the detectors are performing well and can provide an independent measurement of the collision rates. Top: Cross section of the beamline near the interaction point. Left: BSC detectors surrounding the beam pipe The detectors studied, the beam shower counters (BSC), are scintillator detectors and are used at the CDF detector at Fermilab. These are able to detect charged particles. They are made of three parts: a scintillator, a light guide, and a photomultiplier tube (PMT). open gate trigger gate test signal However, most of the collisions are soft, resulting in particles produced in the forward direction. The detectors studied are in the forward regions of the interaction point and are used to determine rates of beam losses in order to monitor the quality of the beam, and to measure the collision rates. The coincidence of the signals of the BSC counters placed on opposite sides of the interaction point is a result of a p collision. The different colors correspond to different run numbers. The coincidence rate (N) is related to the instantaneous luminosity (L) through the relation N=  L  where   is the cross section accepted by the counters. The coincidence of the signals of the BSC counters placed on opposite sides of the interaction point is a result of a p  p collision. The different colors correspond to different run numbers. The coincidence rate (N) is related to the instantaneous luminosity (L) through the relation N=  L  where   is the cross section accepted by the counters. BSC coincidence rate at different instantaneous luminosity from colliding beam data at CDF. Proton and antiproton beam loss rates measured with the BSC counters at CDF. Beam loss rates are measured at CDF to monitor the quality of the beam. p loss rate  p loss rate