Tagging spectrometer and photon beamline Review January 23-24, 2006 1 Response to Questions Bremsstrahlung Tagging Spectrometer and Photon Beam Review.

Slides:



Advertisements
Similar presentations
Kerstin Sonnabend, IKP, TU Darmstadt S-DALINAC - Nuclear Astrophysics Nuclear Astrophysics at the Darmstadt superconducting electron linear accelerator.
Advertisements

Tagger and Vacuum Chamber Assembly Procedure. Outline. Assembly procedure for tagger and vacuum chamber. Support stands. Alignment.
Overview of the GlueX Tagger and Photon Beamline..
Eurotag Workshop Sept 1 st - 2 nd 2008 Ken Livingston, University of Glasgow Overview of I3HP, JRA, Eurotag Summary of Eurotag objectives Aims of this.
Collimation and tagging instrumentation for the GlueX photon beamline Richard Jones Igor Senderovich, Anne-Marie Carroll University of Connecticut APS/DNP.
1/22 MOLLER Juliette M. Mammei. 2/22 Working Groups Polarized Source Hydrogen Target Spectrometer Integrating Detectors Tracking Detectors Polarized Beam.
June Yong Yang, Nuclear physics site Mentor : Dr. Richard Jones.
Lecture 18. Chemical: XPS.
Pair Spectrometer Design Optimization Pair Spectrometer Design Optimization A. Somov, Jefferson Lab GlueX Collaboration Meeting September
Hall D Photon Beam Simulation and Rates Part 1: photon beam line Part 2: tagger Richard Jones, University of Connecticut Hall D Beam Line and Tagger Review.
Upcoming Review of the Hall D Photon Beam and Tagger Richard Jones, University of Connecticut, for the GlueX collaboration GlueX Collaboration Meeting.
Status of the Tagger Hall Background Simulation Simulation A. Somov, Jefferson Lab Hall-D Collaboration Meeting, University of Regina September
July 2001 Snowmass A New Measurement of  from KTeV Introduction The KTeV Detector  Analysis of 1997 Data Update of Previous Result Conclusions.
Tagger Electronics Part 1: tagger focal plane microscope Part 2: tagger fixed array Part 3: trigger and digitization Richard Jones, University of Connecticut.
A linac-based Mu2e calibration system George Gollin Department of Physics University of Illinois at Urbana-Champaign Urbana, IL USA
The Hall D Photon Beam Richard Jones, University of Connecticut Hall D Photon Beamline-Tagger ReviewJan , 2005, Newport News presented by GlueX Tagged.
Tagger hodoscope and photon beam monitoring D.Sober, F.Klein (CUA) Tagger Review, Jan.23-24, 2006.
Elton S. Smith University of Virginia October 25, Overview Bremsstrahlung Tagging Spectrometer and Photon Beam Review Elton S. Smith Jefferson Lab.
Tagger and Vacuum Chamber Assembly Procedure. Preassembly of second bottom yokes and poleshoes. a) Install special support. b) Place the second bottom.
Accelerator hall of the S- DALINAC – electron energies from 2 to 130 MeV available – cw and pulsed beam operation possible – source for polarized electron.
The GlueX Photon Beam Richard Jones, University of Connecticut GlueX Photon Beamline-Tagger ReviewJan , 2005, Newport News presented by GlueX Tagged.
Tagger and Vacuum Chamber Design. Outline. Design considerations. Stresses and deformations. Mechanical assembly.
TAGGER MAGNET DESIGN Presented by Tim Whitlatch Hall D Tagger Magnet Design Review July 10,
Progress on Photon Beam and Simulation Part 1: active collimator Part 2: physics simulations Richard Jones, University of Connecticut GlueX collaboration.
The Tagger Microscope Richard Jones, University of Connecticut Hall D Tagger - Photon Beamline ReviewJan , 2005, Newport News presented by GlueX.
Photon Source and Tagger Richard Jones, University of Connecticut GlueX Detector ReviewOctober 20-22, 2004, Newport News presented by GlueX Tagged Beam.
Bubble Chamber Planning Meeting 04 September
SHMS Detector Commissioning and Installation Howard Fenker Hall-C Users Meeting Jan-2015.
We are Here! Gluex Collaboration Meeting May Engineering Status - Presented by Tim Whitlatch1.
The Hall D Photon Beam Overview Richard Jones, University of Connecticut Hall D Tagged Photon Beam ReviewNov , 2008, Newport News presented by GlueX.
PAIR SPECTROMETER DEVELOPMENT IN HALL D PAWEL AMBROZEWICZ NC A&T OUTLINE : PS Goals PS Goals PrimEx Experience PrimEx Experience Design Details Design.
The GlueX Experiment in Hall-D
23 July 2012D. Sober1 Some thoughts on Hall D tagger magnet field mapping D. Sober Catholic University of America GlueX Beam/Tagger biweekly meeting 23.
Elton S. Smith Tagger and Photon Beam Dry Runs Nov 14, Tagger and Photon Beamline Review and goals for today.
Status of the Beamline Simulation A.Somov Jefferson Lab Collaboration Meeting, May 11, 2010.
EuroTag Workshop, Glasgow, 1/9/08 A General Geant4 Tagger Simulation David J. Hamilton University of Glasgow ( EuroTag.
Experiment beam line installation (9/4/2014) SystemThus FarTo Do Vacuum~ Torr, IP’s on, Vac interlock checkNone Fast valveValve + CCG installed,
HPS Beamline: Background Rates, Sensitivity to Field Uncertainties M. Ungaro1HPS Collaboration Meeting, JLAB, May Concrete Wall thickness Study.
Hovanes Egiyan Jefferson Lab. Main Hall B Beamline Components Beam Tuning Procedure HV System in Hall B Temperature Sensors Summary 10/19/ Hovanes.
PrimEx collaboration meeting Energy calibration of the Hall B bremsstrahlung tagging system using magnetic pair spectrometer S. Stepanyan (JLAB)
HPS T EST R UN C ONTINGENCY P LAN S. Stepanyan JLAB.
Glasgow University Seminar October 2006 A Novel Photon Polarimeter Joseph Santoro CUA Glasgow University Seminar October, 2006.
Overview of the GlueX Tagger and Photon Beamline..
Molecular Mass. Mass of Atom Measured in atomic mass unit (amu) 1 amu = 1.66 x g Defined by assigning the mass of 12 amu to the carbon-12 isotope.
Study of γd --> K + Λn through 3-track detected events with the NKS2 HONDA Kazuhisa Tohoku University.
CEBAF The Continuous Electron Beam Accelerating Facility (CEBAF) at JLab in Newport News, Virginia, is used to study the properties of quark matter. CEBAF.
Photon Flux Control Liping Gan UNCW. Outline PrimEx-  experiment requirement Tagged photon Procedure to obtain the number of tagged photons Relative.
The Electromagnetic Spectrum Coach Smith. EM Spectrum 0 Types 0 Radio 0 Microwave 0 Infrared 0 Visible light 0 Ultraviolet 0 X-rays 0 Gamma rays.
Photon Source and Tagger Richard Jones, University of Connecticut GlueX Detector ReviewOctober 20-22, 2004, Newport News presented by GlueX Tagged Beam.
COMET and DeeMe. Mu-e conversion search at J-PARC COMET Target sensitivity 10 C.L. using aluminum target – SINDRUM II 7x – MEG 2.4x
HLAB meeting paper 2011/1/18 T.Gogami CLAS ( CEBAF Large Acceptance Spectrometer ) Clam shell is open.
Hall D Tagger and Beamline Review, Nov , 2008, Newport News1 Question Question: How can you reliably extract the polarization of the collimated beam.
Low Momentum dE/dx Testbeam H.P. 7/24/98. Goals for Spectrometer are based on tracking and PID –Multiparticle correlation –production of particle species.
 0 life time analysis updates, preliminary results from Primex experiment 08/13/2007 I.Larin, Hall-B meeting.
Photon Source and Tagger Richard Jones, University of Connecticut GlueX Detector ReviewOctober 20-22, 2004, Newport News presented by GlueX Tagged Beam.
Proposal for the End Station Test Beam (ESTB) at SLAC John Jaros ALCPG09 Albuquerque September 30, 2009.
Tagger and Vacuum Chamber Design Jim Kellie Glasgow University.
A compact pair polarimeter and spectrometer
Collimation and tagging instrumentation
CLAS, Hall-B Tagged linear and circularly polarised photons
IHEP group Shashlyk activity towards TDR
Polarimetry Ken Livingston Sept 2012
Bubble Chamber Planning Meeting
Preparation of the CLAS12 First Experiment Status and Time-Line
Bubble Chamber – Beam Requirements
End Station Test Beam (ESTB) at SLAC
The Mass Spectrometer.
Beam-time, June 2009 Beam-time, Oct days of beam time
Hall “12 GeV” May 27, 2003 NAPP 2003: J.J. LeRose.
Beam-time, June 2009 Beam-time, Oct days of beam time
Presentation transcript:

Tagging spectrometer and photon beamline Review January 23-24, Response to Questions Bremsstrahlung Tagging Spectrometer and Photon Beam Review Richard Jones, Jim Kellie, Dan Sober and Elton Smith

Tagging spectrometer and photon beamline review Jan 23-24, Response to questions  Describe the procedure for assembly and alignment of magnets, vacuum chamber and hodoscope, including mounting for the first time and also after a disassembly. ─ See presentation by Jim Kellie  What is the requirement for the vacuum in the tagging system? ─ Require that the radiation due to air < radiation from radiator → vacuum < torr.  What is required for the magnetic properties of the steel? ─ Define the chemistry of the steel (e.g. low carbon) ─ Request samples of steel and measure B-H curves for the samples ─ Accept final steel with same chemistry of samples ─ Note: We are not very sensitive to the quality of the steel at 1.5 T.

Tagging spectrometer and photon beamline review Jan 23-24, Response to questions  What plans do we have to determine the absolute photon energy? ─ For initial running, calculation of the photon energy based on measured (calculated?) field maps of the magnets should be sufficient. ─ Calibration of the absolute energy scale to can be achieved using a magnetic pair spectrometer. This procedure has recently been completed for the Hall B tagger (see CLAS-NOTE ). This would require instrumenting the pair spectrometer with additional microstrip detectors.  To what precision does the experiment need to know the polarization? ─ Richard will write a response to this