Active and reactive power

Slides:



Advertisements
Similar presentations
“Power Factor” In Transmission System
Advertisements

CE ELECTRICAL PRINCIPLES STEADY STATE ANALYSIS OF SINGLE PHASE CIRCUITS UNDER SINUSOIDAL EXCITATION 1 Steady State response of Pure R,L and C &
Waves and Transmission Lines Wang C. Ng. Traveling Waves.
Waves and Transmission Lines TechForce + Spring 2002 Externship Wang C. Ng.
Chapter 12 RL Circuits.
Electronics Inductive Reactance Copyright © Texas Education Agency, All rights reserved.
Sinusoidal Steady-State Power Calculations
AC Power: instantaneous and average power
ECE 201 Circuit Theory I1 Complex Power Designate as S Magnitude of S = Apparent Power Units are Volt-Amperes The complex sum of Real Power (P) and Reactive.
AC Power: average power
Example ECE 201 Circuit Theory 1. A load having an impedance of 39 + j26 Ω is fed from a voltage source through a line having an impedance of 1.
Lesson 24 AC Power and Power Triangle
Storey: Electrical & Electronic Systems © Pearson Education Limited 2004 OHT 16.1 Power in AC Circuits  Introduction  Power in Resistive Components 
Chapter 19 – Power (AC) Introductory Circuit Analysis Robert L. Boylestad.
Power Factor and Power Factor Correction
Power Factor: What Is It and Estimating Its Cost Presented by:Marc Tye, P.E APPA Business & Financial Conference September 21, 2004.
Problem Solving Part 2 Resonance.
Lesson 26 AC Power and Power Factor
1 Training Session on Energy Equipment Electricity Presentation from the “Energy Efficiency Guide for Industry in Asia” ©
Plant Utility System (TKK-2210)
Disconnect Switches There are many purposes for disconnect switches in substations and power lines. They are used to isolate or deenergize equipment for.
Power Triangle.
Circuits II EE221 Unit 4 Instructor: Kevin D. Donohue Complex Power, Power Conservation, Power Factor Correction, and Applications.
Chapter 12.
Fundamentals of Electric Circuits Chapter 11
Chapter 11 AC Power Analysis
WHO WANTS TO BE A MILLIONAIRE?
Sustainable Energy Systems Engineering Peter Gevorkian Ch 4: Energy Conservation Brevard Community College ETP1401 Bruce Hesher.
Chapter 31 Electromagnetic Oscillations and Alternating Current Key contents LC oscillations, RLC circuits AC circuits (reactance, impedance, the power.
Fundamentals of Electric Circuits Chapter 11
Power in AC Circuits ELEC 308 Elements of Electrical Engineering
Voltage Collapse M. H. Sadeghi Winter 2007 KNTU. Power System Stability IEEE: Power system stability is defined as the capability of a system to maintain.
1 Chapter 11 AC Power Analysis 電路學 ( 二 ). 2 AC Power Analysis Chapter Instantaneous and Average Power 11.2Maximum Average Power Transfer 11.3Effective.
WG A2 50 Effect of Distributed energy sources and consequentinduced reverse flow on transmission and distribution transformers First Meeting Zürich 11.
Electrical Resistance and Ohm’s Law Electric circuits are used to convert electrical energy into some other form of energy we need.
Chapter 7 AC Power Analysis
Circuits II EE221 Unit 11 Instructor: Kevin D. Donohue Complex Power, Power Conservation, Power Factor Correction, and Applications.
Alpha College of Engg & Tech Khatraj, Gandhinagar EEE( ) 1 st SEM EE-A Group 5 1 KOTADIA SMIT SATISHKUMAR ( ) 2 BHANUSHALI SHREYABEN.
Alternating Current Circuits. Resistance Capacitive Reactance, X C.
Tank Circuit & Resonance. Parallel Resonance Tank Circuit This circuit stores energy in the form of electric and magnetic fields so it is a tank (storage)
Chapter-23 Alternating Current Circuits. AC Circuits All the equipment in this operating room use alternating current circuits.
Capacitors are one of the fundamental passive components. In its most basic form, it is composed of two conductive plates separated by an insulating dielectric.
1 ELECTRICAL TECHNOLOGY EET 103/4  Define and explain sine wave, frequency, amplitude, phase angle, complex number  Define, analyze and calculate impedance,
1 ECE 3336 Introduction to Circuits & Electronics Set #15 Complex Power Fall 2011, TUE&TH 4-5:30 pm Dr. Wanda Wosik.
See online explanation at AC Circuits.
1  Explain and calculate average power, apparent power, reactive power  Calculate the total P, Q and S and sketch the power triangle. ELECTRICAL TECHNOLOGY.
E E 2415 Lecture 9 Phasor Circuit Analysis, Effective Value and Complex Power: Watts, VAR’s and Volt-Amperes.
Three Phase Motors Maths
REACTIVE POWER COMPENSATION
Alternating Current Circuits. AC Sources  : angular frequency of AC voltage  V max : the maximum output voltage of AC source.
Impedance is the measure of the opposition that a circuit presents to the passage of a current when a voltage is applied. In quantitative terms, it is.
Halliday/Resnick/Walker Fundamentals of Physics 8th edition
FUNDAMENTAL OF ELECTRICAL POWER SYSTEMS (EE 270)
Chapter 10 RC Circuits.
KAIST NUCLEAR & QAUNTUM NICIEL SEMINAR 1 / 23 Review on Power Factor Young Seung LEE 04/26/2005 SEMINAR.
RC Circuits (sine wave)
Circuit Elements Prepared by:- Priyani Sunny (Enrollment_ ) Manish Jadav (Enrollment_ ) Bhavin Viramgama (Enrollment_ )
Power in AC Circuits Introduction Power in Resistive Components
Lesson 21: AC Power and Power Triangle
Chapter 11 AC Power Analysis
Chapter 17 Resonance Circuits.
SWAMI VIVEKANAND COLLEGE OF ENGINEERING,INDORE(M.P)
Introduction To Reactive Power
Power in AC Circuits Introduction Power in Resistive Components
POWER SYSTEM ANALYSIS INTRODUCTION.
Exercise 7 Power systems.
ELL100: INTRODUCTION TO ELECTRICAL ENGG.
Exercise Session 3 Power systems.
E E 2415 Lecture 9 Phasor Circuit Analysis, Effective Value and Complex Power: Watts, VAR’s and Volt-Amperes.
EEE 3230 POWER SYSTEM ANALYSIS
Presentation transcript:

Active and reactive power Introduction Renewables Summer Course 17.7.2014 Eetu Ahonen

Contents Power Power factor Transmission line impedance Apparent power Active power Reactive power Creation of reactive power Consumption of reactive power Power factor Transmission line impedance Reactive power & renewables Summary Firstly… secondly…

Apparent power (näennäisteho) Power that is transferred by the conductors 𝑆=𝑈𝐼 (Joule’s law) Measured in volt-amperes Transmission lines ”see” only apparent power 𝑆 2 = 𝑃 2 + 𝑄 2 Relation of apparent power S, active power P and reactive power Q. Figure from wikipedia. AC circuits

Active power (pätöteho) Real part of apparent power Transfers real energy, does work Measured in watts (W) In a resistive circuit: 𝑆= 𝑉 rms 𝐼 rms >0 ∀ 𝑡 Current and voltage in phase Energy is dissipated at power 𝑆=𝑃. Electric heater

Reactive power (loisteho) Deadweight, foam of the beer Reactive power does not do work Result of current transferring no energy Measured in VArs (volt-ampere reactive) Imaginary part of apparent power Loisteho = parasitic power

Creation of reactive power In a capacitive circuit Current leads the voltage by 90 degrees 𝑆= 𝑉 rms 𝐼 rms <0 ∃ 𝑡 𝑃=0 Capacitive load creates reactive power Capacitive circuit = only capacitor Voltage and current in a capacitive circuit

Consumption of reactive power In an inductive circuit Current lags the voltage by 90 degrees 𝑆= 𝑉 rms 𝐼 rms <0 ∃ 𝑡 𝑃=0 Capacitive load consume reactive power Inductive = only a coil Voltage and current in an inductive circuit

Power factor Ratio of active power to apparent power cos 𝜙 = 𝑃 𝑆 = 𝑉 𝑅 𝑉 𝑍 = 𝑅 𝑍 ∈[−1,1] Low power factor More demands for conductors Higher reactive and apparent power More distribution losses Example: Power factor of 0.2 (really low), active power demand 1 kW Needed apparent power 5 kVA Can be compensated with capacitors Phi = phase difference of voltage and current Example: Electric motor, fluorescent lamp ballast etc.

Transmission line impedance Transmission lines have resistance and reactance Resistance from the metal Reactance from the capacitive and inductive properties of the circuit Simplified model of a transmission line. 𝐺 spec stands for shunt resistance Shunt resistance = some connection between ground (earth) and the transmission line exist.

Transmission line impedance Transmission lines have significant impedance Restricts the amount of power transferred Voltage can drop or rise(!) over the line Less than 10% voltage drop acceptable Voltage drop over a typical 200 km 100 kV transmission line as a function of active power demand for different values of load power factor Voltage rise: Capacitive load, typical inductive transmission line (overhead)

Reactive power & renewables Renewable sources do not provide reactive power High renewable production Only few large power stations online Reactive power transferred over great distances Voltage collapse due to insufficient line capacity Large plants cannot be used for power control Smaller modular generating units near the loads are needed Other mitigating methods Capacitors Synchronised generators

Summary Power Power factor, measure of a load ”goodness” Apparent power seen by the conductors Active power transfer energy Reactive power Does not transfer energy Created by capacitive loads Consumed by inductive loads Power factor, measure of a load ”goodness” Reactive power demands have to be taken into account in network design Especially in networks with high penetration of renewables To summarise