Validation of Analytical Methods

Slides:



Advertisements
Similar presentations
Supplementary Training Modules on Good Manufacturing Practices
Advertisements

Dr. Birgit Schmauser, BfArM, Bonn
Validation of screening methods (2002/657/EC)
Analytical Method Development and Validation
Instrumental Analysis
1 Method Selection and Development l Initial Considerations n What does the method need to do? 3 What analyte/s need to be assayed? 3 What range or concentration.
| Slide 1 of 43 April 2007 Training Workshop on Pharmaceutical Development with focus on Paediatric Formulations Protea Hotel Victoria Junction, Waterfront.
Integrated Method Development and Validation Dr. Ludwig Huber RACI Conference - Chemical Analyses.
Finished Pharmaceutical Product Specifications
Pharmaceutical Development with Focus on Paediatric formulations
CHEMISTRY ANALYTICAL CHEMISTRY Fall
Stability data required by WHO-PQP Mercy Acquaye.
Chemical Analysis Qualitative Analysis Quantitative Analysis Determination “Analyze” a paint sample for lead “Determine” lead in a paint sample.
PHARM 462 PART / /31 Good Manufacturing Practices (GMP) VALIDATION of ANALYTICAL TEST METHODS.
World Health Organization
Training Workshop on Pharmaceutical Development with a Focus on Paediatric Medicines / October |1 | Pharmaceutical Development Analytical.
Review of Analytical Methods
Quality Assurance Chapter 29. Quantitative Chemical Analysis, Daniel C. Harris, 6 th Edition, New to this edition and a very important topic in industry.
Supplementary Training Modules on Good Manufacturing Practice
Slide 1 of 19D.K. Mubangizi, Dar Es Salaam Sept Training Workshop for Evaluators from National Medicines Regulatory Authorities in East African Community.
Inter-Laboratory Method Transfer
Validation of analytical methods
ASEAN GUIDELINES FOR VALIDATION OF ANALYTICAL PROCEDURES
QUALITY CONTROL OF PHYSICO-Chemical METHODS Introduction :Validation توثيق المصدوقية.
Kyiv, TRAINING WORKSHOP ON PHARMACEUTICAL QUALITY, GOOD MANUFACTURING PRACTICE & BIOEQUIVALENCE Validation of Analytical Methods Used For Bioequivalence.
Chemometrics Method comparison
Validation: concept, & considerations
Validation of Analytical Method
Laboratory Validation of Analytical Methods
WELCOME. UV Spectrophotometric Method Development And Estimation of Bicalutamide in Pharmaceutical Dosage Form.
VALIDATION METHODOLOGY
The following minimum specified ranges should be considered: Drug substance or a finished (drug) product 80 to 120 % of the test concentration Content.
Analytical considerations
How to Select a Test Method Marlene Moore Advanced Systems, Inc. June 15, 2010.
Analytical considerations in the dissolution testing of oral modified release products Graham Clarke Bristol-Myers Squibb Moreton, UK The British Pharmaceutical.
1 Impurities: Positions of the regulatory authorities (like FDA and EMA) worldwide Dr. Christian Zeine, Warsaw, Nov 18, 2014 Science for a safer world.
Quality Assurance How do you know your results are correct? How confident are you?
5. Quality Assurance and Calibration Quality assurance is We do to get the right answer for our purpose. Have Sufficient accuracy and precision to support.
STABILITY TESTING Dr. Laila Khairy PhD, Chairman, NODCAR NATIONAL ORGANIZATION FOR DRUG CONTROL AND RESEARCH Dr. Laila Khairy PhD, Chairman, NODCAR NATIONAL.
1 Exercise 7: Accuracy and precision. 2 Origin of the error : Accuracy and precision Systematic (not random) –bias –impossible to be corrected  accuracy.
Introduction The importance of method validation
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Lect Eli Solomon M.Sc 1 VALIDATION PRINCIPLES Principles of qualification and validation which are applicable to the manufacture of medicinal.
Wenclawiak, B.: Fit for Purpose – A Customers View© Springer-Verlag Berlin Heidelberg 2003 In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in.
Industrial Technology Institute Test Method Validation & Verification H.P.P.S.Somasiri Principal Research Scientist / SDD-QAD /QM Industrial Technology.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
Lecture 10 ANALYTICAL METHOD DEVELOPMENT AND VALIDATION IN HPLC AND GC. Lecture 10 – Chromatography, Dr. Rasha Hanafi 1© Dr. Rasha Hanafi, GUC.
ISO 9000&14000 and validation. INTRODUCTION I S O I S O International Standard Organization ISO in Greek means “equal” and ISO wanted to convey the idea.
SEMINAR ON PRESENTED BY BRAHMABHATT BANSARI K. M. PHARM PART DEPARTMENT OF PHARMACEUTICS AND PHARMACEUTICAL TECHNOLGY L. M. COLLEGE OF PHARMACY.
Chapter 5 Quality Assurance and
EQUIPMENT and METHOD VALIDATION
means to “TO CHECK OR PROVE THE VALIDITY OF” According to FDA – “ The goal of validation is to establish a documented evidence which provides a high degree.
Method Validation-where do I start?
VALIDATION PRINCIPLES
Course: BioT 006 Quality Control & Validation
VALIDATION OF PHARMACEUTICAL PROCESSES
World Health Organization
World Health Organization
Dr. Birgit Schmauser, BfArM, Bonn
Quality Assurance Chapter 29. Quantitative Chemical Analysis, Daniel C. Harris, 6th Edition, New to this edition and a very important topic in.
This teaching material has been made freely available by the KEMRI-Wellcome Trust (Kilifi, Kenya). You can freely download,
Analytical Method Validation
METHOD VALIDATION: AN ESSENTIAL COMPONENT OF THE MEASUREMENT PROCESS
Chapter 5 Quality Assurance and Calibration Methods
Режа: 1. Метрология тушунчаси 2. Валидация
ANALYTICAL METHOD VALIDATION
World Health Organization
Satish Pradhan Dnyanasadhana College, Thane. Department of Chemistry S
Quality Control Lecture 3
Quality Assessment The goal of laboratory analysis is to provide the accurate, reliable and timeliness result Quality assurance The overall program that.
Presentation transcript:

Validation of Analytical Methods Hua YIN

World Health Organization Outline 2017年4月17日星期一 Validation/Verification of the methods Compendial methods Vs Non-compendial methods Summary of the analytical procedure and validation in QOS Method transfer

Validation of Analytical Procedures Testing a method to demonstrate it is suitable for its intended purpose and the results obtained are reliable, accurate and reproducible. Provides confidence that the method will perform properly under intended conditions. Identification tests; Quantitative or limit tests for the control of impurities; Quantitative tests of the active moiety in samples of drug substance or drug product or other selected component(s) in the drug product. Including assay, Content Uniformity, dissolution, content of presevertives.

Validation of Analytical Procedures Type of analytical procedure Characteristics ID Impurities Assay limit quantitative Specificity + Accuracy Precision Repeatability Intermediate precision Linearity/Range Limit of detection Limit of quantitation

Specificity Specificity is the ability to measure specifically the analyte in the presence of other components which may be expected to be present. Typically these might include impurities, degradants, matrix, etc. Lack of specificity of an individual analytical procedure may be compensated by other supporting analytical procedure(s).

Specificity Blank solution - to show no interference Placebo - to demonstrate the lack of interference from excipients Spiked samples - to show that all known related substances are resolved from each other Stressed sample of about 10 to 20% degradation is used to demonstrate the resolution between degradants and the analyte of interest Check peak purity of drug substance by photodiode array detector (PDA) Representative chromatograms should be provided

Accuracy Expresses the closeness of test results obtained by that procedure to the true value= trueness the value accepted as a conventional true value, or an accepted reference value and the value found accuracy should be established across the specified range of the analytical procedure

Accuracy Assay API: against an RS of known purity, or via an alternate method of known accuracy; analysis in triplicate. FPP: placebo/drug product spiked with known quantity of API, in triplicate at each level (80, 100 and 120% of label claim) is recommended. Report recovery (mean result and RSD): 98.0-102.0% ICH Q2 states: accuracy may be inferred once precision, linearity and specificity have been established. (Demonstration preferred).

Accuracy Impurities: API/FPP spiked with known amounts of impurities Recommendations: Across the range of LOQ-150% of the target concentration (shelf life limit), 3-5 concentrations, in triplicate each. (LOQ, 50%, 100%, 150%) Per cent recovery: in general, within 80-120%, depends on the level of limit

Precision Precision of an analytical procedure expresses the closeness of agreement (degree of scatter) between a series of test results obtained from multiple sampling of the same homogeneous sample under the prescribed conditions.(degree of agreement among individual test results). It should be measured by the scatter of individual results from the mean and expressed as the relative standard deviation (RSD). May be considered at three levels Repeatability intermediate precision (ruggedness) reproducibility.

Accuracy & Precision Accurate and precise

Precision Repeatability (method precision) Multiple measurements of a sample by the same analyst A minimum of 6 determinations at the test concentration (6 times of a single batch), or 3 levels (80%, 100%, 120%) , 3 repetitions each Recommendation: For Assay: RSD ≤ 2.0% For individual impurity above 0.05%, in general, RSD ≤ 10%

Precision Intermediate precision Test a sample on multiple days, analysts, equipments RSD should be the same requirement as method precision Reproducibility (inter-laboratory trial) Not requested in the submission Need to be considered for method transfer

Precision Repeatability Condition Intermediate Precision Condition Reproducibility Condition Laboratory Same Different Operator Apparatus Same a Time between Tests Short b Multiple Days Not Specified a This situation can be different instruments meeting the same design requirement. b Standard test method dependent, typically does not exceed one day Matrix design can be used for intermediate precision and reproducibility

Linearity / Range The linearity of an analytical procedure is its ability (within a given range) to obtain test results which are directly proportional to the concentration (amount) of analyte in the sample. The range of an analytical procedure is the interval between the upper and lower concentration (amounts) of analyte in the sample for which it has been demonstrated that the analytical procedure has a suitable level of precision, accuracy and linearity. Minimum 5 concentrations

Linearity / Range Assay : 80-120% of the test concentration Content Uniformity: 70-130% of the test concentration Dissolution: ±20% of limits; eg if limits cover from 20% to 90% l.c. (controlled release), linearity should cover 0-110% of l.c. Impurities: LOQ to 120% of shelf life limit Assay/Purity by a single method: LOQ of the impurities to 120% of assay limit

Linearity / Range Correlation coefficient (r) Assay: r ≥ 0.999 Impurities: r ≥ 0.99 y-Intercept and slope should be indicated together with plot of the data

LOD/LOQ The detection limit of an individual analytical procedure is the lowest amount of analyte in a sample which can be detected but not necessarily quantitated as an exact value. The quantitation limit of an individual analytical procedure is the lowest amount of analyte in a sample which can be quantitatively determined with suitable precision and accuracy.

LOD/LOQ Visual evaluation (non-instrumental method) signal to noise ratio: LOD 3:1 , LOQ 10:1 standard deviation of the response and the slope of the calibration curve at levels approximating the LOD /LOQ σ = the standard deviation of the response S = the slope of the calibration curve should be validated by analysis of samples at the limits.

LOD/LOQ LOD: below the reporting threshold LOQ: at or below the specified limit Not required for assay/dissolution methods. Applicant should provide the method of determination the limits, chromotograms

Robustness The method's capability to remain unaffected by small but deliberate variations in method parameters (for HPLC) Influence of variations of pH in a mobile phase Influence of variations in mobile phase composition Different columns (different lots and/or suppliers) Temperature Flow rate Establish the System suitability parameters If robustness indicates a limitation, this must be clearly stated in the method

Note The recommended acceptance criteria for each validation characteristics in this presentation are mainly for validation of HPLC method. It is based on normal process and experiences in the review of prequalification submissions. Other approach for validation characteristic may be applicable and acceptable. It is important to remember that the main objective of validation of an analytical procedure is to demonstrate that the procedure is suitable for its intended purpose.

Revalidation Revalidation may be necessary Changes in the synthesis of the drug substance; Changes in the composition of the finished product; Changes in the analytical procedure.

Compendial versus in-house standards

Validation, verification, equivalency Validation: full validation required for in-house methods, generally specificity, linearity, accuracy, repeatability, intermediate precision, plus for purity: LOD/LOQ. Verification: required for most compendial methods Equivalency: required for an in-house method, when compendial standard is claimed

When compendial methods are adopted Verification data is required. The compendial methods as published are typically validated based on an API or an FPP originating from a specific manufacturer. Different sources of the same API or FPP may contain impurities and/or degradation products that were not considered during the development of the monograph. The FPP may also contain excipients not present in the FPP(s) for which the compendial method was developed. Therefore, the suitability of compendial methods should be verified under actual conditions of use for the specified API or FPP matrix.

When compendial methods are adopted API Assay: No validation generally required. Exception: specificity for any specified impurities not in the monograph. Purity: Full validation for specified impurities that are not included in the monograph (specificity, linearity, accuracy, repeatability, intermediate precision, LOD/LOQ).

When compendial methods are adopted FPP Assay: Specificity, accuracy and precision (repeatability). Eg. to rule out excipient interference. Purity: Specificity, accuracy and precision (repeatability) for known imps. Full validation for specified impurities that are not included in the monograph (specificity, linearity, accuracy, repeatability, intermediate precision, LOD/LOQ)

Compendial standard claimed, but in-house method used Full validation is required for an in-house purity/assay method. Equivalency must be demonstrated compared to the compendial method Assay: same samples using the two methods; Related substances: same samples spiking with specified impurities at the limits) using the two methods If equivalency is not demonstrated, it can not be claimed as compendial standard

Equivalency Equivalency is essentially two things: Ensure the in-house method is not inferior (in which case they should adopt the compendial method) Ensure the compendial test can be met, if applied. Two samples are sufficient. Note that a compendial method becomes an in-house method when adjustments are made outside the allowable adjustments (Int.Ph, USP, EP general chapter Chromatography)

Reporting Validation Specificity: chart of Rf or RRT values and discussion, if neccessary. Accuracy: Conc.__, recovery __, RSD = __; n = __ Precision: Conc. = __, n = __, RSD = __ Linearity/Range: range = __ - __; corr. coeff. = __; slope = __ Sensitivity: LOD = __; LOQ = __; QOS 3.2 R.2 (example)

Transfer of analytical procedures

Transfer of analytical procedures Method transfer is the documented process that qualifies a laboratory (the receiving unit) to use an analytical test procedure that originated in another laboratory (the transferring unit). To ensure the receiving unit has the procedural knowledge and ability to perform the transferred analytical procedure as intended.

Transfer of analytical procedures World Health Organization Transfer of analytical procedures 2017年4月17日星期一 USP <1224>: Several approaches to demonstrate: Comparative testing on homogeneous lots of the target material, e.g. same lots of standard production batches or samples spiking of known impurities Covalidation between laboratories, i.e. including the receiving unit in an interlaboratory covalidation to obtain data for the assessment of reproducibility. A preapproved transfer or validation protocol that stipulates the details of the procedure should be used.

Transfer of analytical procedures USP <1224> The potential components of a transfer protocol objective, scope, responsibilities, instruments and analytical procedure materials: samples, reference standards experimental design: specific characteristics to be evaluated, analysis to be used to evaluate the outcomes acceptance criteria evaluation of the outcomes: report forms, handling deviations/failure results

Transfer of analytical procedures USP <1224> The possibility of waiver Compendial method—verification Same or similar to a procedure already in use at the receiving unit Similar product to the existing one analysed at the receiving unit: comparable composition, similar concentration of API. The personnel in charge of the analysis/development/validation are moved to the receiving unit

Transfer of analytical procedures PQP practice Method transfer that should include specificity and reproducibility. Reproducibility should be demonstrated by providing results of analysis of a minimum of 2 batches at each test site. Impurities: comparable results for samples spiked with the known impurities at concentrations which are close to their specification limits.

Transfer of analytical procedures PQP practice cont. When analytical methods have been developed in a GMP compliant facility and the original site included intermediate precision, method transfer report may not be required to be submitted, but they should be available.

In conclusion To evaluate the clarity and completeness of the desciption of the analytical methods To confirm the sameness to compendial methods if compendial standard is claimed To review the verification/validation/equivalent data and confirm the suitability for the intended use Review QOS 3.2.R.2 and confirm with the submitted dossier

Thank you !