SINGLE PHOTON AVALANCHE DIODE (SPAD): FROM SINGLE ELEMENT TO ARRAY (SPADA) (SWORD) G. Bonanno, M. Belluso, F. Zappa, S. Tisa, S. Cova, P. Maccagnani, D.

Slides:



Advertisements
Similar presentations
Optoelectronics & Microsystems Lab Politecnico di Milano, Dip. Elettronica e Informazione, Milano, Italy.
Advertisements

S. Cova et al., 2004 POLIMI - Politecnico di Milano, DEI Optoelectronics & Microsystems Lab Bias: well ABOVE breakdown Geiger-mode: its a TRIGGER device!!
Liverpool Group presentation 22/07/2009
Corfu 10/9/07 ( HTRA: ~ 100 ms -- 1μs ) - To develop the most promising technologies for HTRA - Assess relative strengths/areas of application in astronomy.
A photon-counting detector for exoplanet missions Don Figer 1, Joong Lee 1, Brandon Hanold 1, Brian Aull 2, Jim Gregory 2, Dan Schuette 2 1 Center for.
HgCdTe Avalanche Photodiode Arrays for Wavefront Sensing and Interferometry Applications Ian Baker* and Gert Finger** *SELEX Sensors and Airborne Systems.
Parameters to choose the CCD The CCD test bench *Temperature range : -55 to +40°C. *Stabilization : < 0.05°C/hour. *5 temperature probes : CCD and electronics.
Astronomical Detectors
EE 230: Optical Fiber Communication Lecture 11 From the movie Warriors of the Net Detectors.
Chris Maloney May 10, 2011 Characterization of a Geiger-mode Avalanche Photodiode.
06/02/2008CCDs1 Charge Coupled Device M.Umar Javed M.Umar Javed.
Fiber-Optic Communications
Mid-IR photon counting array using HgCdTe APDs and the Medipix2 ROIC
1 Detectors RIT Course Number Lecture Single Element Detectors.
Characterization of a Geiger-mode Avalanche Photodiode a Rochester Institute of Technology, Department of Electrical and Microelectronic Engineering; b.
Semiconductor Optical Single-Photon Diode
Near-infrared (NIR) Single Photon Counting Detectors (SPADs)
Charge-Coupled Device (CCD)
CCD testing Enver Alagoz 12 April CCD testing goals CCD testing is to learn how to – do dark noise characterization – do gain measurements – determine.
Fiber Optic Receiver A fiber optic receiver is an electro-optic device that accepts optical signals from an optical fiber and converts them into electrical.
OPTICAL DETECTORS IN FIBER OPTIC RECEIVERS.
Characterization of Silicon Photodetectors (Avalanche Photodiodes in Geiger Mode) S. Cihangir, G. Mavromanolakis, A. Para. N.Saoulidou.
Overview of Scientific Imaging using CCD Arrays Jaal Ghandhi Mechanical Engineering Univ. of Wisconsin-Madison.
Copyright : Marconi Applied Technologies Limited. All Rights Reserved. CCDs for Adaptive Optics CfAO Workshop: Nov 1999 By P.
Ground-based optical auroral measurements
CUÑADO, Jeaneth T. GEQUINTO, Leah Jane P. MANGARING, Meleria S.
Chapter 6 Photodetectors.
4/11/2006BAE Application of photodiodes A brief overview.
CMOS and Microfluidic Hybrid System on Chip for Molecule Detection Bowei Zhang, Qiuchen Yuan, Zhenyu Li, Mona E. Zaghloul, IEEE Fellow Dept. of Electrical.
Introduction on SiPM devices
Photon detection Visible or near-visible wavelengths
3/26/2003BAE of 10 Application of photodiodes A brief overview.
Chapter 5 Optical Detector.
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
H.-G. Moser Max-Planck-Institut for Physics, Munich CALOR 06 Chicago June 5-9, 2006 Silicon Photomultiplier, a new device for low light level photon detection.
Fast Detectors for Medical and Particle Physics Applications Wilfried Vogel Hamamatsu Photonics France March 8, 2007.
Single-photon imaging in complementary metal oxide semiconductor processes by E. Charbon Philosophical Transactions A Volume 372(2012): March 28,
CCD Detectors CCD=“charge coupled device” Readout method:
Salvatore Tudisco The new generation of SPAD Single Photon Avalanche Diodes arrays I Workshop on Photon Detection - Perugia 2007 LNS LNS.
Silicon Photomultipliers
Detectors for Light Sources Contribution to the eXtreme Data Workshop of Nicola Tartoni Diamond Light Source.
10/26/20151 Observational Astrophysics I Astronomical detectors Kitchin pp
Creating a System to Test Single Photon Avalanche Diodes Introduction Single Photon Avalanche Diodes (SPADs) are optical sensing amplifiers which make.
Brazilian Tunable Filter Imager (BTFI) Preliminary Design Review (PDR)‏ USP-IAG Universidade de São Paulo 18-19th June 2008 Julian David Rodriguez Javier.
1 Development of Multi-Pixel Photon Counters (1) S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira, K.Yoshimura, (KEK) Oct
Development of Multi-Pixel Photon Counters(MPPC) Makoto Taguchi Kyoto University.
Photodetectors What is photodetector (PD)? Photodetector properties
1 SiPM studies: Highlighting current equipment and immediate plans Lee BLM Quasar working group.
Sensor testing and validation plans for Phase-1 and Ultimate IPHC_HFT 06/15/ LG1.
10 th Pisa Meeting on Advanced Detectors, Isola d’Elba, May 2006 Development of the first prototypes of Silicon Photomultiplier at ITC-irst N. Dinu, R.
28 June 2007G. Pauletta: ALCPG Tests of IRST SiPMs G. Pauletta Univ. & I.N.F.N. Udine Outline 1.IRST SiPMs : baseline characteristics 2.first application.
Optical Receivers Theory and Operation
Prospects to Use Silicon Photomultipliers for the Astroparticle Physics Experiments EUSO and MAGIC A. Nepomuk Otte Max-Planck-Institut für Physik München.
On a eRHIC silicon detector: studies/ideas BNL EIC Task Force Meeting May 16 th 2013 Benedetto Di Ruzza.
Cameras For Microscopy Ryan McGorty 26 March 2013.
Update on works with SiPMs at Pisa Matteo Morrocchi.
Development of characterization facilities and front-end electronics for SiPM R. A. Shukla, For SiPM Development Group.
Study of Geiger Avalanche Photo Diode applications to pixel tracking detectors Barcelona Main Goal The use of std CMOS tech. APD's in Geiger mode (that.
Silicon Photomultiplier Development at GRAPES-3 K.C.Ravindran T.I.F.R, OOTY WAPP 2010 Worshop On behalf of GRAPES-3 Collaboration.
Topic Report Photodetector and CCD
Study of the Radiation Damage of Hamamatsu Silicon Photo Multipliers Wander Baldini Istituto Nazionale di Fisica Nucleare and Universita’ degli Studi di.
Fondazione Bruno Kessler Centre for Materials and Microsystems.
D. Renker, PSI G-APD Workshop GSI, PAUL SCHERRER INSTITUT Problems in the Development of Geiger- mode Avalanche Photodiodes Dieter Renker Paul Scherrer.
Performance of 1600-pixel MPPC for the GLD Calorimeter Readout Jan. 30(Tue.) Korea-Japan Joint Shinshu Univ. Takashi Maeda ( Univ. of Tsukuba)
Development of Multi-Pixel Photon Counters (1)
Introduction to the physics of the SiPM
FINAL YEAR PROJECT 4SSCZ
NI-sbRIO BASED PLATFORM FOR REAL TIME SPECTROSCOPY
Optical Receivers 1. Photo Detectors
Presentation transcript:

SINGLE PHOTON AVALANCHE DIODE (SPAD): FROM SINGLE ELEMENT TO ARRAY (SPADA) (SWORD) G. Bonanno, M. Belluso, F. Zappa, S. Tisa, S. Cova, P. Maccagnani, D. Bonaccini Calia, R. Saletti, R. Roncella, S. Billota INVASION OF DETECTORS INAF – Catania Astrophysical Observatory Dept. of Electronics, Politecnico di Milano ESO European Southern Observatory Dept. of Information Engineering, Pisa University SPADA: an Array of SPAD Detectors for Astrophysical Applications Electro-Optical Characteristics of a SPAD M. Belluso, G. Bonanno, S. Billotta, A. Calì, S. Scuderi, M. Mazzillo, P.G. Fallica, D. Sanfilippo, E. Sciacca, S. Lombardo Characterization of SPAD Arrays MANUFACTURERS: ST Microelectronics R&D of Catania IMM-CNR R&D of Catania LAMEL, IMM-CNR R&D of Bologna

Taormina, 2005Scientific Detectors Workshop2 Detectors for Fast Transient Phenomena and Adaptive Optics CCD can really be used for all kind of stellar observations? CCD are integrating devices, with relatively slow readout (even with multi-port architectures) and show a read noise (!!!!/??). Techniques of signal intensifying “on-chip” (L3 CCD) or off-chip (MCP coupling) are good only for the observation of faint sources. How to observe faint and fast photon sources with the highest QE? How can obtain time resolution and fast gating for Adaptive Optics without complex controllers? Suitable detectors ? Silicon detectors operating in photon counting regime

Taormina, 2005Scientific Detectors Workshop3 Basically, a SPAD detector is a semiconductor junction diode that can sustain an avalanche multiplication process when reverse biased. Instead of a standard Avalanche Photodiode (APD), which is operated below the breakdown voltage in the analog multiplication regime, a SPAD is biased above its breakdown voltage. Applied voltage levels are such that the electric field is sufficiently tall to generate ionization from impact. APD – SPAD comparison APDSPAD BIAS : MODE : GAIN : Below BD linear e-/ph Above BD Geiger infinite AMPLIFIERTRIGGER

Taormina, 2005Scientific Detectors Workshop4 SPADA System (Curvature Wavefront Sensor) Current Status The SPADA chip is assembled on a ceramic holder and is cooled by a Peltier module. The cooling system has been designed in collaboration with ESO and finalized via industrial contracts. SPADA chip SPADA element Each SPAD is biased and driven by an appropriate detection and control electronics. Core of the Detection electronics are the integrated Active-Quenching Circuits (iAQC), one for each SPAD. MORE DETAILS ON THE POSTER CURRENT STATUS LENSLETS Array ESO SPADA chip realized DETECTION Boardrealized DATA-PROCESSINGrealized MECHANICAL HOUSING & CRYOSTAT under constr. DATA ACQUISITION SOFTWARE realized THE COMPLETE SYSTEM IS EXPECTED AT THE END OF THIS YEAR.

Taormina, 2005Scientific Detectors Workshop5 DETECTION AND CONTROL ELECTRONICS The entire Detection Board provides not only the 12 chips containing a total of 60 iAQCs, but also 15 quad output drivers for a total of 60 differential lines (requested for compatibility with the existing MACAO systems). Core of the Detection electronics are the integrated Active-Quenching Circuits (iAQC), one for each SPAD. Each iAQC is able to bias the correspondent SPAD above the breakdown voltage, generate a digital pulse each time a photon is detected and quickly quench the SPAD (by lowering its bias below breakdown). At the end of the cycle, the SPAD is ready to detect a new photon.

Taormina, 2005Scientific Detectors Workshop6 Adaptive Optics: The system acts as a Curvature WaveFront System (CWFS). By means of a moving membrane, the conjugated plane is moved with sinusoidal oscillations “before” (detected counts A) and “after” (detected counts B) the SPADA focal plane. The curvature signal is then evaluated as: (A-B)/(A+B) by an “on board FPGA circuit”. The acquisition is repeated in free running. Fast Transient Phenomena: In this operational mode, data corresponding to the 60-pixel SPADA detector are acquired every integration time window (tw settled in the range 100µs-100ms), allowing time-tagging of incoming photons, with quite enough resolution for the various astronomical applications, as for example fast events due to gamma rays burst, or low luminous flux with high temporal variation, like pulsar, polar and asteroseismology observations. Astrophysical Applications

Taormina, 2005Scientific Detectors Workshop7 Electro-Optical Characteristics of a SPAD To reduce the dark counts at few counts per second, is mandatory to operate the SPAD at temperatures below 0 °C. A mechanical housing working under vacuum conditions hosts the packaged detector and can be easily interfaced with the measurement apparatus. Dark counts and after-pulsing Quantum Efficiency Response Uniformity MASK OF DIFFERENT DIAMETER SINGLE SPAD Manufactured by STM The response uniformity has been measured by using a recently available facility constituted by a three axes translator that mount on top a reflective objective illuminated by a 10 µm pin-hole through a fiber optic that pick-up the monochromatic light from the Char. Sys. Optical Fiber In a 20 µm 25°C, dark is constant vs the hold-off (switched-off) time  no after-pulsing. Dark depends on the overvoltage and ranges from 300 to 1500 counts/s. The dark rate may be affected by after-pulsing  traps in Si (releasing of charge at different time). QE measurements have been carried-out on 10, 20, 50 µm SPADs at overvoltages of: 10, 20 and 30 %. For all the SPADs we find a QE typical of Si devices that peaks at nm. We found a QE dependence from the SPAD diameter and the overvoltage. At each movement the corresponding count rate is acquired and stored in a file. Simultaneously an IDL procedure read the file and produces a 3D plot of the currently acquired data. The 3D plot shows a 50 x 50 µm scan with 5 µm resolution. The 5 X 5 µm central area presents a flat response (5000 counts/s), confirming the response uniformity in that area. MORE DETAILS ON THE POSTER

Taormina, 2005Scientific Detectors Workshop8 Characterization of SPAD Arrays For SPAD Array test, another mechanical housing working under vacuum conditions and hosting the packaged detector as well as the AQC boards have been deigned and realized. Dark counts MapQuantum Efficiency 5 X 5 40 µm SPAD ARRAY MASK Manufactured by STM The cryogenic system is able to operate the array detector at a temperature adjustable in the -30 ÷ +30 °C range. MORE DETAILS ON THE POSTER Dark count rate map obtained by biasing with an overvoltage of 20 % each SPAD array element and with an hold-off time of 6 µs. Only two pixels are out of the mean value of about 3000 cnts/s  At room temperature the array shows a dark quite uniform over all the array. Quantum Efficiency 600 nm Overvoltage 20% hold-off 6 µs Quantum Efficiency map of all the array elements at =600nm, obtained biasing each SPAD at 20% above breakdown and settling 6 µs as hold-off time. The mean value is about 57% and is evident the uniform sensitivity at 600 nm over all the array.

Taormina, 2005Scientific Detectors Workshop9 Thank you For your attention/patience