Large sapphire substrate absorption measurements for LIGO S.M.A.- VIRGO Université Claude Bernard LYON I IPNL - IN2P3 – CNRS 22, Boulevard Niels Bohr 69622.

Slides:



Advertisements
Similar presentations
Turbulence in the system of two immiscible liquids Petr Denissenko, Sergei Lukaschuk, Sergei Poplavski Laboratory of Fluid Dynamics, The University of.
Advertisements

ILIAS 5-6/11/2004 WG T2 Task T2 (WG 11) AIM: exact definition (theoretical and experimental) of photo-thermal noise PARTICIPANTS INFN (AURIGA group; also.
Advanced LIGO1 Laser Induced Damage due to Particulate Contamination Billingsley, Gushwa, Phelps, Torrie, Zhang LVC meeting March 2014.
TeO2 single crystals for Acousto-optics and Optoelectronics.
ACADs (08-006) Covered Keywords Efficiency, LLD, CPM, DPM, relative efficiency, absolute efficiency, standard deviation, confidence, count time. Description.
Transient FEM Calculation of the Spatial Heat Distribution in Hard Dental Tissue During and After IR Laser Ablation Günter Uhrig, Dirk Meyer, and Hans-Jochen.
Laser Safety Calculations
X-Sender: LIGO-C D X-Mailer: QUALCOMM Windows Eudora Version 5.1 Date: Tue, 28 Sep :52: To: Armandula Helena From:
Laser &Optics of LCGT 2011/10/5(Wed) Norikatsu Mio Photon Science Center University of Tokyo EGO-ICRR Meeting 2011/10/4-5.
Dublin/July'04 1 BLTS interferometers: Big, Low-temperature Transparent Silicon Interferometers Warren Johnson Louisiana State University LIGO-G Z.
Measurement of the thermal conductivity of sapphire fibers
Reconfigurable Inspection Machine (RIM). NFS Engineering Research Center for Reconfigurable Manufacturing Systems College of engineering, University of.
D EDICATED S PECTROPHOTOMETER F OR L OCALIZED T RANSMITTANCE A ND R EFLECTANCE M EASUREMENTS Laetitia ABEL-TIBERINI, Frédéric LEMARQUIS, Michel LEQUIME.
Scaling Three-Dimensional Figures 9-9 Warm Up Warm Up Lesson Presentation Lesson Presentation Problem of the Day Problem of the Day Lesson Quizzes Lesson.
Alban REMILLIEUX3 rd ILIAS-GW Annual General Meeting. London, October 26 th -27 th, New coatings on new substrates for low mechanical loss mirrors.
LIGO-G Z TNI Progress and Status Greg Ogin LSC Meeting March 22, 2007 Eric Black, Kenneth Libbrecht, Dennis Coyne Grad students: Akira Villar,
Absorption in bulk crystalline silicon and in the crystal surfaces Aleksandr Khalaidovski 1 Alexander Khalaidovski 1, Jessica Steinlechner 2, Roman Schnabel.
Rayleigh Scattering Mapping System School of Physics, University of Western Australia Australia – Italy Workshop on GW Detection 2005.
How do we detect photons? Kensuke Okada RIKEN BNL Research Center April 20,
Thermal Compensation in Stable Recycling Cavity 21/03/2006 LSC Meeting 2006 UF LIGO Group Muzammil A. Arain.
Absorption in bulk crystalline silicon and in the crystal surfaces Aleksandr Khalaidovski 1 Alexander Khalaidovski 1, Jessica Steinlechner 2, Roman Schnabel.
Université Lyon I NATO/ASI and Euro Summer School September 16-27, 2002 JM.M SMASMA OPTICS IN ASTROPHYSICS Coatings Performances & Limitations Jean-Marie.
LIGO-G D LIGO and Industry Capability/ProductCompany Ultra-high Vacuum TechnologyCB&I Passive Seismic IsolationHytec Inc. Active Seismic IsolationBarry.
Photo-thermal Deflection Spectroscopy George Noid LIGO SURF Student.
LIGO- G D LSC Meeting, Hannover, GE August LIGO Scientific Collaboration1 Advanced LIGO Optics Status Report Dave Reitze University of Florida.
Optical Coatings R&D Status Gregory Harry Massachusetts Institute of Technology - On Behalf of the Coating Working Group - August, 2004 LSC Meeting Hanford.
Last coating Q measurements at MIT Flavio Travasso Gregg Harry Matt Abernathy LIGO – G Z.
8-10 Scaling Three-Dimensional Figures Course 3 Warm Up Warm Up Problem of the Day Problem of the Day Lesson Presentation Lesson Presentation.
Microscopy Unit C – Cycling of Matter in Living Systems.
Aerosol Limits for Target Tracking Ronald Petzoldt ARIES IFE Meeting, Madison, WI April 22-23, 2002.
IRAD 2371 Week 3.  Very few detectors will count every interaction  Each detector will have its own counting efficiency  Eff=CPM/DPM  Can use efficiency.
M. Dugger, February Triplet polarimeter study Michael Dugger* Arizona State University *Work at ASU is supported by the U.S. National Science Foundation.
ILIAS - GWA N5 - Strega JRA3 General Meeting Orsay - November 5th-6th, 2004 M1 Activities.
Experimental investigation of dynamic Photothermal Effect
LIGO Laboratory1 Thermal Compensation in LIGO Phil Willems- Caltech Baton Rouge LSC Meeting, March 2007 LIGO-G Z.
Janyce Franc-Kyoto-GWADW1 Simulation and research for the future ET mirrors Janyce Franc, Nazario Morgado, Raffaele Flaminio Laboratoire des Matériaux.
Sapphire for the LCGT project Eiichi Hirose ICRR, University of Tokyo Kyohei Watanabe, Norikatsu Mio PSC, University of Tokyo GT Advanced Technology, Sep.
Floating and Sinking Whatever floats your boat!. Warm-up 1. Observe the two beakers on the front table and record your observations. 2. Predict- will.
RICH MEETING - CERN - April 21 st 2004 Università degli Studi di Milano Bicocca Variation of Refractive Index inside an Aerogel Block Davide Perego.
Calibration of energies at the photon collider Valery Telnov Budker INP, Novosibirsk TILC09, Tsukuba April 18, 2009.
Some considerations on radiative cooling V. Fafone, Y. Minenkov, I. Modena, A. Rocchi INFN Roma Tor Vergata.
Heinert et al Properties of candidate materials for cryogenic mirrors 1 Properties of candidate materials for cryogenic mirrors D. Heinert,
Comparison of different chamber configurations for the high luminosity upgrade of M2R2 G. Martellotti - LNF - 13/03/2015 Roma1 + Alessia.
Year 7: Length and Area Perimeter The perimeter of a shape is the total distance around the edge of a shape. Perimeter is measured in cm A regular shape.
1 Cascina – October 19, 2011 ASPERA Forum Laurent Pinard Substrates, Polishing, Coatings and Metrology for the 2 nd generation of GW detector Laurent PINARD.
1 Radiation Environment at Final Optics of HAPL Mohamed Sawan Fusion Technology Institute University of Wisconsin, Madison, WI HAPL Meeting ORNL March.
STREGA WP4 coating development GEO LIGO ISA Scientific motivation: Mechanical dissipation from dielectric mirror coatings is predicted to be a significant.
Material Downselect Rationale and Directions Gregory Harry LIGO/MIT Kavli Institute for Astrophysics and Space Technology On behalf of downselect working.
Science Review for Volume Quiz October 25, What is volume? The amount of space an object or liquid takes up.
8-10 Scaling Three-Dimensional Figures Warm Up Problem of the Day
Califes Laser Optical design
Manuel Marchiò, Raffaele Flaminio, Shunshi Kuroki
Fast scanning systems for Laser-wires
Science Review for Volume Quiz October 24, 2017
Pressure vs height (solid CPA plane)
Laboratoire des Matériaux Avancés - Lyon
Control of laser wakefield amplitude in capillary tubes
Thermal emittance measurement Gun Spectrometer
LIGO Scientific Collaboration
Main Efforts of the Core Optics WG
New Results on Photothermal Effect: Size and Coating Effect
Modeling of Advanced LIGO with Melody
Warm Up Problem of the Day Lesson Presentation Lesson Quizzes.
A RTP crystal electro-optic modulator for next generation gravitational wave detector Wan Wu, Volker Quetschke, Ira Thorpe, Guido Mueller, David Reitze,
Wire Diameter Variation
Synthetic Sapphire Absorbance at 1064 nm
Report on p0 decay width: analysis updates
LIGO Photon Calibrators
ITM03; LHO ITMx Post O2 inspection LIGO-T v1
8-10 Scaling Three-Dimensional Figures Warm Up Problem of the Day
Presentation transcript:

Large sapphire substrate absorption measurements for LIGO S.M.A.- VIRGO Université Claude Bernard LYON I IPNL - IN2P3 – CNRS 22, Boulevard Niels Bohr Villeurbanne Cedex - France Université Lyon I SMASMA April 2003 Sapphire substrate from Crystal Systems Inc. Boule N° AJ5, L46 1

Orientation of the substrate The sapphire substrate is slightly damaged at the edge of one side. For all the measurements, the substrate is positioned so that the defects are in the front and at the bottom of the substrate (slide # 3). Accuracy of the absorption measurements The absolute value of the sapphire absorption is calculated thanks to the measurement of the absorption of a silica reference, the density and the specific heat capacity of sapphire and silica. The modulation frequency used for the measurement was high: 3000 Hz. The absorption of the silica reference is calculated thanks to the measurement of the absorption of ultra pure water (0.13 cm -1 ), the density and the specific heat capacity of silica and water. A cross calibration was made with the Laboratoire d’Optique at ESPCI Paris. The agreement is in the percent range. Moreover, we recorded during 3 hours and 20 minutes the absorption of the center part of the sapphire substrate in order to check the stability of the measurement. We got: /- 0.3 ppm.cm -1 (slide # 3). Elementary volume measured by our photothermal deflection bench The elementary volume scanned by the absorption measurement depends on the waists of the probe and the pump beams (  100 µm x 100 µm) and on the interaction length of probe and pump beams (3 mm). The interaction lenght is set by the angle between probe and pump beams: 3.5° (slide # 3). Artifacts due to non-photothermal deflection of the probe One drawback of the photothermal deflection technique is that the measured absorption is deduced from the deflection of the probe beam. If the deflection is only due to a photothermal effect, than the absorption measurement is correct, but if the deflection is due to scratches, small inclusions, refractive index variations of the substrate, … than the absorption measurement is wrong. In order to estimate the artifacts due to non-photothermal deflection of the probe, we recorded an « absorption » map, without the pump laser. The maximum artifact is 1.4 ppm.cm -1 and the mean value is 0.4 ppm.cm -1 (slide # 4). These values are high compared to what we would have with a super polished substrate without scratches nor inclusions but they are negligible compared to the absorption of the sapphire which is always higher than 30 ppm.cm -1. Absorption vs depth At 3 different (X,Y) positions, we scanned the absorption versus the depth (Z). The ranges of absorption variation for each (X,Y) position are: [32-36 ppm.cm -1 ], [45-74 ppm.cm -1 ] and [ ppm.cm -1 ]. At Z=0 and Z=-131 mm, the absorption is influenced by the « inspection polished » surfaces (slide # 5). Absorption maps We recorded 6 maps at 6 different depths. The diameter of the maps is 200 mm and the step between the points is 2.5 mm. The general shape of all the maps doesn’t change very much (slide # 6), but for each map,the absorption varies from  30 to  130 ppm.cm -1 (slides # 7-12). We recorded two zooms with small steps of 0.1 mm on 2 pixels of the previous maps. The zooms show variation of absorption at the 0.1 mm scale. (slides # 9;10). Large sapphire substrate absorption measurements for LIGO 2

Accuracy of the absorption measurements : +/- 0.3 ppm.cm -1 Absorption recorded at X = 0 mm Y = 1 mm Z = -57 mm during 3h 20mn: /- 0.3 ppm.cm -1 Defects in the front at the bottom 131 mm thick X Y Z 0  314 mm Orientation of the substrate: Elementary volume measured by our photothermal deflection bench: X  0.1 mm Y  0.1 mm Z  3 mm X Z Y 3

Z = -74 mm In this experiment, the YAG is switched off, in order to evaluate the influence of scratches, small inclusions, refractive index variations, … on the deflection of the probe laser. Mean absorption: 0.45 ppm.cm -1  200 mm scan 4 mm steps Artifacts due to non-photothermal deflection of the probe are in the sub-ppm.cm -1 range. 4

X = 0 mm Y = 0 mm X = -50 mm Y = -5 mm X = mm Y = -55 mm Absorption vs depth 5 Z = -68 mm Max = 36.0 ppm.cm -1 Min = 32.2 ppm.cm -1 Max = 74.4 ppm.cm -1 Min = 45.3 ppm.cm -1 Max = ppm.cm -1 Min = 67.3 ppm.cm -1

X Y Z 0 Z = -63 mmZ = -57 mmZ = -68 mmZ = -74 mm Z = -18 mm Z = -126 mm 6 Absorption maps at 6 different depths

Mean absorption: 57 ppm.cm -1  200 mm scan 2.5 mm steps 7 Absorption map at Z = -18 mm

Mean absorption: 67 ppm.cm -1  200 mm scan 2.5 mm steps Mean absorption: 91 ppm.cm -1 30x30 mm² zoom 1 mm steps 8 Absorption map at Z = -57 mm

Mean absorption: 67 ppm.cm -1  200 mm scan 2.5 mm steps Mean absorption: 101 ppm.cm x3.5 mm² zoom 0.1 mm steps 9 Absorption map at Z = -63 mm

Mean absorption: 66 ppm.cm -1  200 mm scan 2.5 mm steps Mean absorption: 113 ppm.cm x3.5 mm² zoom 0.1 mm steps 10 Absorption map at Z = -68 mm

Mean absorption: 62 ppm.cm -1  200 mm scan 2.5 mm steps 11 Absorption map at Z = -74 mm

Mean absorption: 61 ppm.cm -1  200 mm scan 2.5 mm steps 12 Absorption map at Z = -126 mm