Sangtae Kim Ph.D. candidate University of California, San Diego

Slides:



Advertisements
Similar presentations
Modification Site Localization Why is this a problem? Calculating localization reliability Ways of representing reliability Modification ambiguity.
Advertisements

Protein Quantitation II: Multiple Reaction Monitoring
Improvements in Mass Spectrometry for Life Science Research – Does Agilent Have the Answer? Ashley Sage PhD.
Improved proteomic analysis pipeline for LC-ETD-MS/MS
Introduction to MALDI-TOF MS
CH 908: Mass Spectrometry Lecture 8 Collisionally Activated Dissociation (of proteins and peptides) Prof. Peter B. O’Connor.
How to identify peptides October 2013 Gustavo de Souza IMM, OUS.
PepArML: A model-free, result-combining peptide identification arbiter via machine learning Xue Wu, Chau-Wen Tseng, Nathan Edwards University of Maryland,
De Novo Sequencing v.s. Database Search Bin Ma School of Computer Science University of Waterloo Ontario, Canada.
Protein Sequencing and Identification by Mass Spectrometry.
Data Processing Algorithms for Analysis of High Resolution MSMS Spectra of Peptides with Complex Patterns of Posttranslational Modifications Shenheng Guan.
Yoona Kim University of California, San Diego UCSD Mass Spectrometry Journal Club 12/03/10.
ProReP - Protein Results Parser v3.0©
Proteomics Informatics – Protein identification II: search engines and protein sequence databases (Week 5)
Proteomics Informatics Workshop Part I: Protein Identification
Previous Lecture: Regression and Correlation
Mass Spectrometry. What are mass spectrometers? They are analytical tools used to measure the molecular weight of a sample. Accuracy – 0.01 % of the total.
Goals in Proteomics 1.Identify and quantify proteins in complex mixtures/complexes 2.Identify global protein-protein interactions 3.Define protein localizations.
Peptide Ion Fragmentation Technologies CID = collision induced dissociation CAD = collision activated disassociation.
Spectral Counting. 2 Definition The total number of identified peptide sequences (peptide spectrum matches) for the protein, including those redundantly.
Proteomics Informatics – Overview of Mass spectrometry (Week 2)
<Instant Notes, D. Kealey & P.J. Haines>
Evaluated Reference MS/MS Spectra Libraries Current and Future NIST Programs.
Tryptic digestion Proteomics Workflow for Gel-based and LC-coupled Mass Spectrometry Protein or peptide pre-fractionation is a prerequisite for the reduction.
Karl Clauser Proteomics and Biomarker Discovery Taming Errors for Peptides with Post-Translational Modifications Bioinformatics for MS Interest Group ASMS.
Production of polypeptides, Da, and middle-down analysis by LC-MSMS Catherine Fenselau 1, Joseph Cannon 1, Nathan Edwards 2, Karen Lohnes 1,
Collision-based methods: Electron-based methods: Primary methods for dissociating peptides Collision-based methods: Ion trap collisional activation.
HPP Preliminary Results La Cristalera, August 2012 Montserrat Carrascal, Joan Villanueva, Joaquín Abián LP-CSIC/UAB.
Center for Human Health and the Environment
CH 908: Mass Spectrometry Lecture 8 Collisionally Activated Dissociation (of proteins and peptides) Prof. Peter B. O’Connor.
Acknowledgements This work is supported by NSF award DBI , and National Center for Glycomics and Glycoproteomics, funded by NIH/NCRR grant 5P41RR
Common parameters At the beginning one need to set up the parameters.
Analysis of Complex Proteomic Datasets Using Scaffold Free Scaffold Viewer can be downloaded at:
A Phospho-Peptide Spectrum Library for Improved Targeted Assays Barbara Frewen 1, Scott Peterman 1, John Sinclair 2, Claus Jorgensen 2, Amol Prakash 1,
Protein and Peptide Sequencing by FTMS Susan Martin.
Laxman Yetukuri T : Modeling of Proteomics Data
ETD & ETD/PTR Electron Transfer Dissociation Proton Transfer Reaction
MS Intro. MS requires gas-phase ions, why? MS uses magnetic and electric fields to control the path of a compound based on mass to charge ratio (m/z)
Temple University MASS SPECTROMETRY FURTHER INVESTIGATIONS Ilyana Mushaeva and Amber Moscato Department of Electrical and Computer Engineering Temple University.
Poster produced by Faculty & Curriculum Support (FACS), Georgetown University Medical Center Application of meta-search, grid-computing, and machine-learning.
Faster, more sensitive peptide identification from tandem mass spectra by sequence database compression Nathan J. Edwards Center for Bioinformatics & Computational.
Multiple flavors of mass analyzers Single MS (peptide fingerprinting): Identifies m/z of peptide only Peptide id’d by comparison to database, of predicted.
Eat Raw & Fresh: Introducing isotopic Mass-to-charge Ratio and Envelope Fingerprinting (iMEF) and ProteinGoggle for Protein Database Search Zhixin(Michael)
Methods for LTQ Orbitrap A Guided Tour with Examples
EBI is an Outstation of the European Molecular Biology Laboratory. In silico analysis of accurate proteomics, complemented by selective isolation of peptides.
Background Aerosols are studied for –Environment impact Direct climate effect Indirect climate effect –Biofuels –Human health impact Medicinal Cigarette.
Poster produced by Faculty & Curriculum Support (FACS), Georgetown University Medical Center Application of meta-search, grid-computing, and machine-learning.
Novel Peptide Identification using ESTs and Genomic Sequence Nathan Edwards Center for Bioinformatics and Computational Biology University of Maryland,
Salamanca, March 16th 2010 Participants: Laboratori de Proteomica-HUVH Servicio de Proteómica-CNB-CSIC Participants: Laboratori de Proteomica-HUVH Servicio.
Click to add Text Sample Preparation for Mass Spectrometry Sermin Tetik, PhD Marmara University July 2015, New Orleans.
Mascot Example Slides. MS/MS Database Search Example Data: BSAonespectra.mgf (one spectra) Database: bovine Fixed modifications: Carboxymethyl(C )
Constructing high resolution consensus spectra for a peptide library
DIA Method Design, Data Acquisition, and Assessment
Objective  To develop methods for analysis of compounds in organic aerosol particles Why is this important?  Environmental impact  Alternative fuels.
Introduction to Liquid Phase Mass Spectrometry
Computational Challenges in Metabolomics (Part 1)
Quantitation using Pseudo-Isobaric Tags (QuPIT) and Quantitation using Pseudo-isobaric Amino acids in Cell culture (QuPAC) Parimal Samir Andrew J. Link.
Target Analyses in Parallel Reaction Monitoring Mode (PRM)
MS Libraries for Forensics: DART-MS and GC-MS
Goals in Proteomics Identify and quantify proteins in complex mixtures/complexes Identify global protein-protein interactions Define protein localizations.
Database Search Algorithm for Identification of Intact Cross-Links in Proteins and Peptides Using Tandem Mass Sepctrometry 신성호.
Mass Spectrometry 101 (continued) Hackert - CH 370 / 387D
A Database of Peak Annotations of Empirically Derived Mass Spectra
The Haystack Is Full of Needles: Technology Rescues Sugars!
Proteomics Informatics –
Overview of the analytical workflow used in this study and a representative MS/MS spectrum.a, Overview of the analytical workflow used in this study. Overview.
Mass Spectrometry THE MAIN USE OF MS IN ORG CHEM IS:
Shotgun Proteomics in Neuroscience
Identification of Post Translational Modifications
MS3 for peptide identification and mapping phosphorylation sites
Presentation transcript:

Sangtae Kim Ph.D. candidate University of California, San Diego UCSD Mass Spectrometry Journal Club Feasibility of Large-Scale Phosphoproteomics with Higher Energy Collisional Dissociation Fragmentation Sangtae Kim Ph.D. candidate University of California, San Diego 11/12/2010 Center for Computational Mass Spectrometry

What is it about? Can we use the HCD technology for large-scale phosphoproteomics studies? Yes!

MS technologies are evolving

Why are people crazy about high-precision spectra? High-precision MS1? High-precision MS2? Unambiguous precursor charge determination Decrease the search space - Unambiguous fragment ion charge determination - Better separation of signal/noise

Strategies to generate mass spectra High-low strategy High-precision MS1 Low-precision MS2 High-high strategy High-precision MS2 High-low strategy is preferred!

How much do we benefit from high-precision MS/MS spectra? MS-GFDB search results with QTOF dataset from Agilent

Why are people still using ion-trap for MS2? Cheap Sensitive Fast

Fragmentation technologies CID (Collision Induced Dissociation) Advantages Disadvantages ETD (Electron Transfer Dissociation) HCD (Higher energy Collisional Dissociation) New fragmentation technique High-high strategy

HCD

HCD features Requires LTQ-Orbitrap High-resolution, high-accuracy MS2 No loss of low mass ions Lower sensitivity! Immonium ions are detectable! - not so bad with LTQ-Orbitrap Velos

HCD spectra vs CID spectra HCD spectra generated by LTQ-Orbitrap Velos machine is much better than this (10-fold more ion current)

Claim High-high strategy using HCD is as good as or better than high-low strategy! For phosphosproteome analysis

Dataset HeLa S3 cells Enrichment of phosphopeptides by TiO2 beads Mascot 2.2 Precursor mass tolerance 7ppm Fragment mass tolerance 0.02Da or 0.5Da C+Carbamidomethylation fixed N-acetyl Prot, Ox Met, Phospho STY 2 missed cleavages 1% FDR at three levels (site, peptide, protein) For HCD/CID, up to most 10/20 peaks were selected for MS2 fragmentation.

Results With the high-high strategy with HCD, they identified 9668 (class I) phosphorylation sites (16559 total). With the high-low strategy with CID (pseudo MS3 mode), they identified 9016 (class I) phosphorylation sites (11893 total).

Comparison of HCD and CID spectra

Comparison of HCD and CID spectra

Mass accuracy

HCD vs CID for high-high strategy

Sensitivity issue HCD requires more ions to generate good quality spectra (ion target value 30,000 for HCD vs 5,000 for CID). For many spectra, the target-value was not reached because of the injection time limit (150ms). Is is fine?

Sensitivity issue

Are identifications from HCD spectra different from those from CID spectra?

Conclusion High-high strategy using HCD is as good as or better than high-low strategy using CID.

Criticisms All experimental results are based on Mascot search Mascot does not fully benefit from high-accuracy (limit 0.25Da) HCD results are better than presented?