ECE5320 Mechatronics Assignment#01: Literature Survey on Sensore and Actuators Topic: Quartz Crystal Microbalances Prepared by: Jack J Stepan Dept. of.

Slides:



Advertisements
Similar presentations
PHOTONIS USA Resistive Glass Capillary Inlet Tubes
Advertisements

Assignment#01: Literature Survey on Sensors and Actuators ECE5320 Mechatronics Assignment#01: Literature Survey on Sensors and Actuators Topic: Water Pump.
Assignment#01: Literature Survey on Sensors and Actuators ECE5320 Mechatronics Assignment#01: Literature Survey on Sensors and Actuators Topic: Hall Effect.
Semiconductor Input Devices
Lecture 21 QCM and Ellipsometry
Quantum System “ Ion flux fraction measurement system.
Pressure sensors ​ Presenters ​ Joonas Virtanen ​ Vu Nguyen08 May 2014.
Prepared by: Mike Tyger Dept. of Electrical and Computer Engineering
Assignment#01: Literature Survey on Sensors and Actuators ECE5320 Mechatronics Assignment#01: Literature Survey on Sensors and Actuators Electrostatic.
(Industrial Electronics) Engr. M. Laiq Ur Rahman
Assignment#01: Literature Survey on Sensors and Actuators ECE5320 Mechatronics Assignment#01: Literature Survey on Sensors and Actuators Topic: Peltier.
Assignment#01: Literature Survey on Sensors and Actuators ECE5320 Mechatronics Assignment#01: Literature Survey on Sensors and Actuators Topic: Comb Drive.
Principles of Electronic Communication Systems
Assignment#01: Literature Survey on Sensors and Actuators ECE5320 Mechatronics Assignment#01: Literature Survey on Sensors and Actuators Topic: Breathalyzers.
Assignment#01: Literature Survey on Sensors and Actuators ECE5320 Mechatronics Assignment#01: Literature Survey on Sensors and Actuators Topic: Electronic.
A PRESENTATION ON ELECTRONIC NOSE PRESENTED BY vivek gangwar ELECTRONICS & COMMUNICATION.
Hydraulics.
ECE5320 Mechatronics Oxygen Sensor 3/11/2010 Prepared by: Carlos D. Guzman Dept. of Electrical and Computer Engineering Utah State University E:
Capacitors for RF Applications Michael P. Busse Vice President Dielectric Laboratories, Inc 2777 Rte. 20 East Cazenovia, NY
Assignment#01: Literature Survey on Sensors and Actuators ECE5320 Mechatronics Assignment#01: Literature Survey on Sensors and Actuators Topic: Electroactive.
Assignment#01: Literature Survey on Sensors and Actuators ECE5320 Mechatronics Assignment#01: Literature Survey on Sensors and Actuators Topic: Control.
Assignment#01: Literature Survey on Sensors and Actuators ECE5320 Mechatronics Assignment#01: Literature Survey on Sensors and Actuators Inductive Proximity.
Topic: Hydraulic Actuators
Assignment#01: Literature Survey on Sensors and Actuators ECE5320 Mechatronics Assignment#01: Literature Survey on Sensors and Actuators Topic: Hydraulic.
ECE5320 Mechatronics Assignment#01: Literature Survey on Sensors and Actuators Topic: Hot Wire Anemometer Prepared by: Michael Wood Dept. of Electrical.
Assignment#01: Literature Survey on Sensors and Actuators ECE5320 Mechatronics Assignment#01: Literature Survey on Sensors and Actuators Topic: Memristor.
Real-Time Detection of Biological Pathogens in Urban Environments Laura Barry Hung Phan Gloria See Introduction to Biosensors Presentation 2 - 4/5/2011.
Current Sensors ECE 5230 Mechatronics Assignment 1 Larry Ballard.
 The easiest way of visualizing this is through the motion of a pendulum.  An oscillation is the change in state from an extreme state (A) to the other.
Pressure Measurement Why is it important?. Pressure Measurement Asses the situation –What is the range of pressures to be measured? –Is pressure dynamic.
Center for Materials for Information Technology an NSF Materials Science and Engineering Center Vacuum Evaporation Lecture 8 G.J. Mankey
MEMs Fabrication Alek Mintz 22 April 2015 Abstract
EKT314/4 Electronic Instrumentation
RPC «REGMIK» 15582, Ukraine, Chernihiv region, Rivnopillya, Gagarin Street, 2B phone.: +38 (0462) , , , , +38 (050)
Computer Process Control Application. Computer process control In computer process control, a digital computer is used to direct the operations of a manufacturing.
Nelson Research, Inc – N. 88 th St. Seattle, WA USA aol.com Non-Optical Bubble Sensing Methods for Electrically Conducting.
ISAT 303-Lab3-1  Measurement of Condition: Lab #3 (2005):  List of parameters of condition: –Linear distance, angular displacement, vibration, displacement,
Bridging Theory in Practice Transferring Technical Knowledge to Practical Applications.
Slide # 1 Velocity sensor Specifications for electromagnetic velocity sensor Velocity sensors can utilize the same principles of displacement sensor, and.
Design of a Computer Controlled Test System for Micro-Electro-Mechanical-Resonator (MEMR) Based Gas Sensor Presenter: Joshua Ward Co-Author: Robert MacKinnon.
Level and Pressure Measurement Christopher Foot Patrick Lawlor.
Advisor : Ru-Li Lin Advisee :Shih-Min Chen Southern Taiwan University of Science and Technology, Department of Mechanical Engineering, Tainan, TAIWAN Date.
NANO 225 Micro/Nanofabrication Characterization: Scanning Probe Microscopy 1.
Astable Multivibrators ©Paul Godin Created February 2007 Modified March 2015 Oscillator Basics Technician Series.
 Switches are commonly employed as input devices to indicate the presence or absence of a particular condition in a system or process that is being monitored.
Astable Multivibrators ©Paul Godin Created February 2007 Oscillator Basics.
ECE201 Lect-281 Capacitors (5.1); Inductors (5.2); Dr. S. M. Goodnick November 7, 2003.
INTRODUCTION TO ROBOTICS INTRODUCTION TO ROBOTICS Part 4: Sensors Robotics and Automation Copyright © Texas Education Agency, All rights reserved.
Surface Acoustics Wave Sensors. Outline Introduction Piezoelectricity effect Fabrication of acoustic waves devices Wave propagation modes Bulk Wave sensor.
V. Bande, Applied Electronics Department (English version)-> Information for students Lecture 12 1 Passive Electronic.
Automatic Gain Control Circuit for Quartz Crystals By – Abhijat Goyal Saliya Subasinghe.
Crystal Oscillator Circuit and Its Working
Metal Nanoparticle Hydrogen Sensor
EKT 451 CHAPTER 6 Sensor & Transducers.
Electric Pressure Transducer
Artificial nose A case-study by Shirish Bharati BT11MEC073 Shivam Rathod BT11MEC074 Siddhant Goyal BT11MEC075 Sushant Somkuwar BT11MEC076 Measurement and.
TEMPERATURE SENSOR.
Instrumentation & Measurement
Presentation on Actuators.
WEBENCH® Coil Designer
Prof. Sajid Naeem (DOES – PC)
Mechatronics - ME2401 Proximity Sensor.
Immobilization Of Biomolecules On Biosensors
Scanning Probe Microscopy History
Capacitors for RF Applications Michael P. Busse Vice President
Design of a Computer Controlled Test System for
Scanning Probe Microscopy History
Gauss's Law and Boundary Conditions
Atomic Force Microscope
Presentation transcript:

ECE5320 Mechatronics Assignment#01: Literature Survey on Sensore and Actuators Topic: Quartz Crystal Microbalances Prepared by: Jack J Stepan Dept. of Electrical and Computer Engineering Utah State University E: T: (435) F: (435) (ECE Dept.) W: 3/11/2005

Outline Reference list To probe further Major applications Basic working principle illustrated A typical sample configuration in application (application notes) Major specifications Limitations And many more relevant issues in application (such as, how to choose, cost information, where to buy etc.)

Reference List oup/contents/instrumentation/QCM/QCM.htmhttp:// oup/contents/instrumentation/QCM/QCM.htm QCM-Z500_Article.pdfhttp:// QCM-Z500_Article.pdf

To Explore Further (survival pointers of web references etc) This is a specific sensor, so websites are fairly straightforward. Some websites have glossaries that are informative Also try searches for nanotechnology and quartz crystals Some of the reference list websites contain references for further reading

Major Applications Thin film thickness monitoring Biotechnology Functionalized surfaces Thin film formation Surfactant research Drug research Liquid plating and etching Particle detection

What is a QCM ? (quartz crystal microbalance ) The QCM is a piezoelectric device capable of extremely sensitive mass measurement with nanogram sensitivity.

How does it work? 3 easy steps 1.The quartz crystal is oscillated by an alternating, high frequency electric field applied by the electrodes 2.If any mass sticks to the surface, the resonant frequency of the crystal changes 3.The change in frequency is measured and the change in mass can be calculated by the Sauerbrey equation

Sauerbrey Equation:

You will also need… An oscillator –A circuit that produces the signal to oscillate the crystal A holder –To aid in handling the crystal which you can’t touch Frequency counter –To measure the change in frequency Temperature monitor –Keeps the temperature in the operating range

Accessories Most manufacturers provide all the necessary electronics and equipment here are a few things that come in handy: PC –Often a data interface is available Flow chamber –So only the desired fluids are in contact Cleaning supplies –Deionized water, cleaning basket, and other chemicals as necessary

Typical setup This is an electrochemical setup from scratch; most suppliers have the entire setup already available

Major Specifications Frequency Range –The frequencies at which the QCM is operable Frequency Tolerance –The amount of frequency deviation from a specified center frequency at ambient temperature Frequency Stability –The amount of frequency deviation from the ambient temperature frequency over the operating temperature range

Major specs. cont’d Temperature Range (operating and storage) –The minimum and maximum temperature for which the deviation from the nominal frequency will not vary by a given amount Shunt Capacitance –The capacitance derived from the dielectric of the quartz, the area of the electrodes and the holder Load Capacitance –The value of capacitance used in conjunction with the crystal unit (user specified)

Major specs cont’d Drive Level –The amount of power dissipation in the crystal. Maximum power is the most power the device can dissipate while still maintaining operation with all electrical parameters guaranteed Aging –A systematic change in frequency and or resistance with the passage of time due to internal changes in the crystal

Sample specs

Features Nanogram resolution! Real time capability- frequency and therefore mass, can be monitored as a function of time Non-corrosive, it can handle wide range of chemicals High signal to noise ratio Now has measurement ability in liquids

Limitations Nanogram resolution, but can’t measure larger masses Molecules or particulates must stick to the surface. Extensive preparation is usually required to accomplish this Aging -it just wears out Temperature sensitivity -measurements limited to relatively small temperature range

What is available? Gold, silver, platinum and other metal electrodes Varying temperature ranges and range sizes Varying frequency ranges and range sizes Specialized for gas or liquid measurement

Where to buy This is an expensive sensor, a total unit package from SRS costs $1000 Ten crystals are about $300 BIE department setup worth over $3000

Closed Loop Control With a QCM This sensor is usually not used in control systems, but… Bio-engineers are working on coatings that could allow QCM’s to repeatedly sense viruses or other pathogens in the air. This could be useful in an automated system that filters disease from the air in buildings. Or as an automatic warning for biological weapons QCM’s could also be part of automatic manufacturing of membranes or monolayers in nanotechnology There are many possibilities….