Senior Design II Film Thickness Measurement Julian Peters Joe Fitzmyer Brad Demers Coordinator: Dr. Wayne Walter Advisor: Dr. Dale Ewbank Sponsor: Dr.

Slides:



Advertisements
Similar presentations
Measuring film thickness using Opti-Probe
Advertisements

LabVIEW 7.1 Tutorial. Measurement Lab. MECH262-MECH261 Imran Haider Malik January 16, 2006.
Spectroscopic Ellipsometry University of Texas at El Paso Lynn Santiago Dr. Elizabeth Gardner Chem 5369.
Laser ​ Distance measurement ​ by Aleksi Väisänen ​ Pauli Korhonen.
Chemical Source Localization Using Electronic Nose Sensors Joy Chiang, Vanessa Tidwell, Patricio S. La Rosa, Arye Nehorai Department of Electrical and.
SLAC National Accelerator Center
1 Extreme Ultraviolet Polarimetry Utilizing Laser-Generated High- Order Harmonics N. Brimhall, M. Turner, N. Herrick, D. Allred, R. S. Turley, M. Ware,
Closing Summary Design Testing Abstract Monitoring crop heath via aerial photography is a proper technique used to maximize agricultural productivity.
1 Laser Beam Coherence Purpose: To determine the frequency separation between the axial modes of a He-Ne Laser All sources of light, including lasers,
X-Ray Survey of The ATLAS SCT. The ATLAS Semi-Conductor Tracker.
Multidisciplinary Engineering Senior Design Project 6508 Controls Lab Interface Improvement Preliminary Design Review 11/11/05 Team Members: Michael Abbott,
Bradley University Department of Electrical and Computer Engineering 2011 Wind Tunnel Control (WEBWIND) By: Adam Green Advisor: Dr. Aleksander Malinowski.
On-line Turbidity Measurement Statistical Analysis ME 430 Senior Lab Team, Spring 2006 Instructor: Dan Cordon Team Members: Andrew Vogt, Brad Watson, Cristy.
The Gaze Controlled Robotic Platform creates a sensor system using a webcam. A specialized robot built upon the Arduino platform responds to the webcam.
Initial Calibration and Stability Results from the LiCAS RTRS FSI System John Dale for the LiCAS Collaboration IWAA February 2008.
Multidisciplinary Engineering Senior Design Automated Plasma Generator Test System Preliminary Design Review 11/11/05 Project Sponsor: MKS, ENI Incorporated.
Tracking Migratory Birds Around Large Structures Presented by: Arik Brooks and Nicholas Patrick Advisors: Dr. Huggins, Dr. Schertz, and Dr. Stewart Senior.
Spectrophotometer Jan 28, 2002 Deryck Hong Suryadi Gunawan.
FOLLOWER SENSORS AND ACTUATORS EE 552 INTSTRUCTOR :Dr MOHAN KRISNAN BY MOHAMMED KASHIF IQBAL ANESH BODDAPATTI UNIVERSITY OF DETROIT MERCY.
WBS & AO Controls Jason Chin, Don Gavel, Erik Johansson, Mark Reinig Design Meeting (Team meeting #10) Sept 17 th, 2007.
Controls Lab Interface Improvement Project #06508Faculty Advisors: Dr. A. Mathew and Dr. D. Phillips Project Objectives This work focused on the improvement.
Laboratory 5: Introduction to LabVIEW. Overview Objectives Background Materials Procedure Report / Presentation Closing.
Film Thickness Measurement Julian Peters Joe Fitzmyer Brad Demers P06402.
Imaging of flexural and torsional resonance modes of atomic force microscopy cantilevers using optical interferometry Michael Reinstaedtler, Ute Rabe,
Multidisciplinary Engineering Senior Design Project 6218 Soft Tissue “Tensile” Tester Preliminary Design Review 2/24/2006 Project Sponsor: Bausch & Lomb.
GE Energy Silicon Wafer Measurement System Team 10 Olin Biddy Scott Johnson Chetwyn Jones Rob McCoy Tim Weber.
Applications of SPCE to Pharmaceutical Research Kathleen Hamilton, Tom Laue, and James Harper Presentation at the 2007 BITC Meeting University of New Hampshire.
Multidisciplinary Engineering Senior Design Project 6508 Controls Lab Interface Improvement Critical Design Review 2/24/05 Project Sponsor: EE Department.
Automated Feeding Solutions for Dog Owners Preliminary Design Review October 19, 2007 Project Automated Dog Feeder Project Advisor Dr. Hongwei Wu The Canine.
Modern Optics Lab Lab 5 Part 1: Experiments involving Light Polarization  Measuring light transmission through a dichroic material (“polarizer sheet”)
VISPS Overview Capture visual data from two cameras Find laser Triangulate to find X, Y, Z coordinates of laser Output coordinates to RS-232 serial output.
Conference Room Laser Pointer System Anna Goncharova, Brent Hoover, Alex MendesSponsored by Dr. Jeffrey Black Overview The project concept was developed.
On the Design, Construction and Operation of a Diffraction Rangefinder MS Thesis Presentation Gino Lopes A Thesis submitted to the Graduate Faculty of.
Cosmic Ray Muon Detection Department of Physics and Space Sciences Florida Institute of Technology Georgia Karagiorgi Julie Slanker Advisor: Dr. M. Hohlmann.
ME 102A Spring 2010 May 4, 2010 Jennifer Lew Stephen Tu.
Team may00-04 Fazal Baloch, EE Yew-Kwong Soo, EE Wee-Liat Tay, EE Chris Van Oosbree, CprE Walter Wedan, EE Abstract The purpose of this project is to develop.
ISAT 303-Lab3-1  Measurement of Condition: Lab #3 (2005):  List of parameters of condition: –Linear distance, angular displacement, vibration, displacement,
Theoretical Analysis of a Nanosensor based on WO 3 coated Carbon Nanotube for Ultra-high Sensitive Breath Acetone Sensing Ming Xia, Advisor: Prof. Xingguo.
Technion – Israel Institute of Technology Department of Electrical Engineering Winter 2009 Instructor Amit Berman Students Evgeny Hahamovich Yaakov Aharon.
Physics 145 Introduction to Experimental Physics I Instructor: Karine Chesnel Office: N319 ESC Tel: Office hours: on appointment.
Introduction Designing controllers for walking robots presents many challenges. In order for walking robotics to reach this stage, perhaps a new approach.
Data Acquisition Data acquisition (DAQ) basics Connecting Signals Simple DAQ application Computer DAQ Device Terminal Block Cable Sensors.
Eva Ulibarri, Joel Watson, Omonayo Bolufawi, Stephanie Anderson 1.
Abstract Combines are used in fields to perform the complex operations necessary to effectively harvest crops. The swath width detection system would assist.
Alignment Tools Used To Locate A Wire And A Laser Beam In The VISA Undulator Project Wire Finder CALIBRATION A special fixture was constructed to calibrate.
Diagnostics and Optimization Procedures for Beamline Control at BESSY A. Balzer, P. Bischoff, R. Follath, D. Herrendörfer, G. Reichardt, P. Stange.
Introduction to LabVIEW
Time Calibration System for RF Cavity Breakdown Measurements Juan Takase Northwestern University SIST INTERN Fermi National Lab 08/04/2015.
Mass Flow Sensor Integration Team 5: Beau Rodgers Luis Mendez Brian Roberts Keenan Cheeks Sponsored by: Danfoss Turbocor Advised by: Dr. Shih.
A diagnosis method of DC/DC converter aging based on the variation of parasitic resistor 1/11 1. Introduction The power converter system supplies power.
Project Goals: The Hardware: The Problem: Results to Date:
Carousel Interferometer for Metrological Applications
UNIT-3 ADVANCES IN METROLOGY
From: Microtube Laser Forming for Precision Component Alignment
Light-Matter Interaction
Laser Physics & Nonlinear Optics
P13623: Conductive Heat Transfer Lab Equipment
Bashar Mu’ala Ahmad Khader
Electron probe microanalysis EPMA
August 23, 2000 R.N. Dubois Dow Chemical
Product Evaluation & Quality Improvement
Product Evaluation & Quality Improvement
Advanced Methods of Klystron Phasing
FIB, Ellipsometry, Interferometry...
Electron probe microanalysis EPMA
FIB, Ellipsometry, Interferometry...
LightGage™ Frequency Scanning Technology
Turbidity - “A Quantum Leap in Technology” Southwest Section AWWA
Image Acquisition and Processing of Remotely Sensed Data
Project Goals: The Hardware: The Problem: Results to date:
Presentation transcript:

Senior Design II Film Thickness Measurement Julian Peters Joe Fitzmyer Brad Demers Coordinator: Dr. Wayne Walter Advisor: Dr. Dale Ewbank Sponsor: Dr. Satish Kandlikar P06402

Agenda Project Overview & Background Interferometry Background Analysis System Operation System Design Specifications Design Challenges Test Plans Completion Plans

Project Overview – Sponsor’s Major Needs Ability to determine existence and thickness of film Cost-effectiveness Ability to operate in a “dirty” environment Accuracy, but not as demanding as semiconductor applications Must be able to take measurement quickly Must not require constant input from user

Project Overview - Background Meniscus Experiment in RIT Thermal Analysis Lab Figure 1: Moving Meniscus ExperimentFigure 2: Heater surface and water nozzle detail

Project Overview - Background Meniscus Experiment in RIT Thermal Analysis Lab Meniscus Experiment in RIT Thermal Analysis Lab – Unanswered Questions: – Is there a film of adsorbed water left behind the moving meniscus? – How far does it extend? – What is its thickness? Figure 3: Operation of experiment Heated, rotating copper cylinder Meniscus Direction of Rotation Advancing contact line Receding contact line

ii Film Surface Substrate Surface 1) Light is emitted from the laser diode. 2) Two reflections take place: part of the beam reflects from the film surface, part of it continues through the film and reflects from the substrate surface. 3)The two reflected beams recombine. The difference in the path length taken by the two beams manifests itself as a phase difference, which can cause attenuation of the beam intensity. 4) The recombined beam is collected at a sensor. The intensity is measured, and can be compared to the intensity of the original beam. Interferometry in a Nutshell Figure 5: Interferometry Basics

Interferometry Analysis for s-polarization for p-polarization for s-polarization for p-polarization

Analysis of Design MATLAB code written to simulate reflectance response Data from numerical experiments – Determine appropriate wavelengths – Analyze experimental data Most easily identified noise independent parameter of data is the frequency of oscillations

Sample MATLAB Results Figure 10: Oscillatory Reflectance Response

Sample MATLAB Results Figure 11: Non-Oscillatory Reflectance Response at Zero Film Thickness

MATLAB Code Verification Figure 12: Comparison of WVASE32 and MATLAB Results

Basic System Diagram Figure 6: Information and control flow through system PC Control HardwareGoniometer Actuators Laser Diode Power PhotosensorLabView Data Collection Hardware Operator Light reflected from surface Information Control

Off-the-Shelf Components Laser diode: CPS196Goniometers: GNL10-Z6 Photodiode: SM05PD1A Motor Controller: ODC001 NI USB DAQ 6008 TI OPA129U

Purchased Components

System Design Physical System Assembly Servo Controller Goniometer Breadboard Base Substrate and Film Servo Controller Photodiode Laser Diode

System Design Physical System Assembly Servo Controller Goniometer Breadboard Base Base Substrate and Film Servo Controller

Specifications & Targets Positioning Accuracy – ± 0.25° Positioning Precision – ± 0.25° Film Thickness Accuracy – ± 5 μm Film Thickness Precision – ± 5 μm Measurement Time – 30 minutes

Design Challenges Light Source – Beam divergence – Suitability of wavelength to film thickness – Consistency of intensity – Polarization intensity – Focal length Photodiode – Must accommodate beam divergence – Accuracy

Design Challenges Positioning Equipment – Accuracy – Repeatability – Synchronicity – Alignment Equipment Mounts – Accuracy – Compensating

Design Challenges PC Interface Hardware / Software – Position control and reporting – Single user input – Collect data from photodiode Data Interpretation Programming – Fit data to simulation – Measure of confidence

Design Challenges Specific Application to Mensicus Experiment – Optical properties of surface – Beam alignment – Flatness of surface

Alignment and Calibration Goniometer zeroes Calibration curve Verify alignment

Alignment and Calibration “Zero” is found by reflecting laser back onto itself. Linear-to-angular step size is found by making marks on target at regular linear steps. 51” 

Alignment and Calibration

Test and Completion Plan Verify assembly alignment Labview code Test against known films Implement Matlab code User manual

Any Questions?

CPS196 Datasheet

Control VI

Part Prints

Sensor-Side Mount

Laser Mount

Sensor Mount

Sample Platform

System Operation User initializes the measurement through a simple GUI Controllers position goniometers at a range of angle increments DAQ measures light intensity incident on photodiode at each position LabView controller inputs position data to motor controllers LabView plots captured data and outputs measured thickness as well as error or confidence level of the measurement