MHD Coating Requirements Dai-Kai Sze, Xueren Wang UCSD UCSD US/Japan Workshop on Power Plant Studies Presented at UCSD October 9-11, 2003.

Slides:



Advertisements
Similar presentations
HEAT EXCHANGER GUIDED BY: PREPARED BY:
Advertisements

Technical Strategies for Pressure Drop Reduction in LM Blankets N. B. Morley, S. Smolentsev, B. Pint, D.-K. Sze, S. Malang APEX/TBM Meeting February 23,
Ss Hefei, China July 19, 2011 Nuclear, Plasma, and Radiological Engineering Center for Plasma-Material Interactions Contact: Flowing.
First Wall Heat Loads Mike Ulrickson November 15, 2014.
TITAN/IEA Liquid Breeder collaboration topics and technical issues Dai-Kai Sze, UCSD Presented at the FNS/TBM meeting UCLA, September 19-20, UCLA.
What is Dual Coolant Blanket? Siegfried Malang 2 nd EU-US DCLL Workshop2 nd EU-US DCLL Workshop University of California,University of California, Los.
Progress on UCLA MTOR Film Flow Experiments for ALIST (Nov April 2003) Presented by Alice Ying M. Abdou, N. Morley, T. Sketchley, J. Burris, M.
1 Dept. of Energy Technology, Div. of Applied Thermodynamics and Refrigeration Tube diameter influence on heat exchanger performance and design. Single.
First Wall Thermal Hydraulics Analysis El-Sayed Mogahed Fusion Technology Institute The University of Wisconsin With input from S. Malang, M. Sawan, I.
September 3-4, 2003/ARR 1 Initial Assessment of Maintenance Scheme for 2- Field Period Configuration A. R. Raffray X. Wang University of California, San.
March 16-17, 2000ARIES-AT Blanket Design and Power Conversion, US/Japan Workshop/ARR ARIES-AT Blanket Design and Power Conversion The ARIES Team Presented.
1 Chapter 27 Current and Resistance. 2 Electric Current Electric current is the rate of flow of charge through some region of space The SI unit of current.
August 17, 2000 ARIES: Fusion Power Core and Power Cycle Engineering/ARR 1 ARIES: Fusion Power Core and Power Cycle Engineering The ARIES Team Presented.
Preliminary Assessment of Porous Gas-Cooled and Thin- Liquid-Protected Divertors S. I. Abdel-Khalik, S. Shin, and M. Yoda ARIES Meeting, UCSD (March 2004)
A Study of Fluid Flow and Heat Transfer in a Liquid Metal in a Backward-Facing Step under Combined Electric and Magnetic Fields E. Gutierrez-Miravete and.
1 Wilfrid Farabolini 23 feb. 04Direction de l’Energie Nucléaire Tritium Control A Major Issue for a Liquid Metal Blanket.
June19-21, 2000Finalizing the ARIES-AT Blanket and Divertor Designs, ARIES Project Meeting/ARR ARIES-AT Blanket and Divertor Design (The Final Stretch)
A design for the DCLL inboard blanket S. Smolentsev, M. Abdou, M. Dagher - UCLA S. Malang – Consultant, Germany 2d EU-US DCLL Workshop University of California,
Status of the ARIES-CS Power Core Configuration and Maintenance Presented by X.R. Wang Contributors: S. Malang, A.R. Raffray ARIES Meeting PPPL, NJ Sept.
Thermofluid MHD issues for liquid breeder blankets and first walls Neil B. Morley and Sergey Smolentsev MAE Dept., UCLA APEX/TBM Meeting November 3, 2003.
March 20-21, 2000ARIES-AT Blanket and Divertor Design, ARIES Project Meeting/ARR Status ARIES-AT Blanket and Divertor Design The ARIES Team Presented.
Overview of Phobos Magnet Designed by Harald Enge Built by Danfysik Technical summary: –“Double dipole” design –15.5 cm air gap –Max. 2 Tesla field –378.
Physics 121 Practice Problem Solutions 11 Faraday’s Law of Induction
Fluid Dynamics and Heat Transfer in a Hartmann Flow RPI Master’s Project Proposal Timothy DePuy – 9/28/2010.
Maintenance Schemes for a DEMO Power Plant and related DCLL Designs Siegfried Malang 2 nd EU-US DCLL Workshop2 nd EU-US DCLL Workshop University of California,University.
A basic property of the tiny particles that make up matter; it can be positive or negative: Some particles of matter have an electric charge. Electric.
Current and Direct Current Circuits
Thermowell Calculation Guide In accordance with ASME PTC 19.3 TW-2010
Chapter 5 Diffusion and resistivity
STEADY HEAT TRANSFER AND THERMAL RESISTANCE NETWORKS
Fouling Factor: After a period of operation the heat transfer surfaces for a heat exchanger become coated with various deposits present in flow systems,
ITER Test Blanket Module and the Need for Coordination Outline What ITER means for the World Technology / Chamber / Blanket Community ITER Plans for TBM.
By S. Saeidi Contribution from: S. Smolentsev, S. Malang University of Los Angeles August, 2009.
Chapter 22 Current and Resistance. Current Conservation of current Batteries Resistance and resistivity Simple circuits Chapter 22 Current and Resistance.
Overall Heat Transfer Coefficient
Neutronics Parameters for Preferred Chamber Configuration with Magnetic Intervention Mohamed Sawan Ed Marriott, Carol Aplin UW Fusion Technology Inst.
Penn ESE370 Fall DeHon 1 ESE370: Circuit-Level Modeling, Design, and Optimization for Digital Systems Day 10: September 28, 2011 MOS Transistor.
October 27-28, 2004 HAPL meeting, PPPL 1 Thermal-Hydraulic Analysis of Ceramic Breeder Blanket and Plan for Future Effort A. René Raffray UCSD With contributions.
Electric fields in Material Space Sandra Cruz-Pol, Ph. D. INEL 4151 ch 5 Electromagnetics I ECE UPRM Mayagüez, PR.
Soil water flow and Darcy’s Law. Laminar flow in a tube Poiseuille’s Law, ~1840: where: Q = volume of flow per unit time (m 3 s -1 ) r = radius of the.
Boundaries, shocks, and discontinuities. How discontinuities form Often due to “wave steepening” Example in ordinary fluid: –V s 2 = dP/d  m –P/  
Chapter 27 Current and Resistance Scalar Sense determined by the movement of the positive charge carrier Average Electric Current Instantaneous Electric.
Electric Circuits. What is Electric Current? Current in a river –The movement of water molecules Higher current = more water passing a given point each.
MHD/Heat Transfer considerations for SiC FCI in DEMO and ITER Sergey Smolentsev DCLL Special Meeting at UCLA April 23-24, 2007.
EXAMPLE 27.1: A copper wire carries a current of 10 A. It has a cross- sectional area of 0.05 cm 2. Estimate the drift velocity of the electrons.
Fluid Dynamics and Heat Transfer in a Hartmann Flow RPI Master’s Project Update Timothy DePuy – 11/15/2010.
Optimization Of a Viscous Flow Between Parallel Plates Based On The Minimization Of Entropy Generation Presentation By Saeed Ghasemi.
Chapter 7 Energy and Energy Balance By : Mrs. Norazian Mohamed Noor
Chapter 4.4 Notes Resistance in Thermal Systems. In fluid systems, resistance opposes the flow of Fluid. In thermal systems, resistance opposes the flow.
Materials Integration by Fission Reactor Irradiation and Essential Basic Studies for Overall Evaluation Presented by N.Yoshida and K.Abe At the J-US Meeting,
Report on testing Snake2 u-channel. P. Jalocha & J. Buytaert. 8 June 2015.
Plan for IEA LB Workshop Dai-Kai Sze, UCSD PattrickCalderoni, INL Fusion Nuclear Science and Technology Meeting UCLA, August 2-4, 2010.
Heat Transfer Introduction and Conduction. Conduction  If a temperature gradient exits in a continuous substance, heat can flow unaccompanied by any.
Progress on coolant routing and MHD ARIES Project Meeting January 2012 M. S. Tillack UC San Diego.
Cooling of GEM detector CFD _GEM 2012/03/06 E. Da RivaCFD _GEM1.
March 3-4, 2005 HAPL meeting, NRL 1 Assessment of Blanket Options for Magnetic Diversion Concept A. René Raffray UCSD With contributions from M. Sawan.
1 A Self-Cooled Lithium Blanket Concept for HAPL I. N. Sviatoslavsky Fusion Technology Institute, University of Wisconsin, Madison, WI With contributions.
INTRODUCTION : 80% of total electricity produced in the world, is hydral, while remaining 20% is produced from nuclear, thermal, geo-thermal energy and.
Summary of Tritium Issues Dai-Kai Sze, UCSD Phil Sharpe, INL FNST Meeting UCLA, August 12-14, 2008.
Page 1 of 12 Design of a low pressure drop liquid metal cooling system M. S. Tillack with advice and assistance from X. R. Wang, S. Malang and others ARIES.
Thermag VII, Turin, Italy
CH 5 – Electricity and Magnetism
DCLL TBM Reference Design
Effect of Calcium on TBR of ARIES-RS Li/V Blanket
Can We achieve the TBR Needed in FNF?
Chapter30: Electromagnetic Induction
Manifolding and MHD issues
Moving Conductors in Magnetic Fields
Fluid Friction in Pipes
VLT Meeting, Washington DC, August 25, 2005
Presentation transcript:

MHD Coating Requirements Dai-Kai Sze, Xueren Wang UCSD UCSD US/Japan Workshop on Power Plant Studies Presented at UCSD October 9-11, 2003

Introduction  For a self-cooled liquid metal blanket for MFE systems, an insulating coating is necessary to control the MHD pressure drop.  This insulating coating can be in the form of self-healing coating, a permanent coating or an insulated insert.  It is important to define how perfect this coating need to be.

MHD Pressure Drop in Fully Developed Flow Conducting wall DP/DX = VB 2 t w k w /a In which V: average velocity B: the transverse magnetic field t w : wall thickness k w: wall electrical conductivity

MHD Pressure Drop in Fully Developed Flow(Continue)

Insulating Wall Duct Dp/dx = kVB 2 /M K: Fluid electrical conductivity M= Ba(k/u) 0.5 U is the viscocity of the fluid. If a= 5 cm, t w = 5 mm, B = 11T, V= 1m/s, L= 1 m For conducting wall DP= 12 MPa For insulated wall DP= 0.01 Mpa

Insulating Wall Duct (Continue)

Coating Requirements  Thermodynamically stable at elevated temperature.  Chemically compatible with liquid metal and structural material at elevated temperature.  Sufficient high electrical resistance during normal operation.  Either self-healing or maintain low cracking fraction during the operation.

Question What is the acceptable cracking fraction in the coating?

Answer The electrical resistance across the crack is much larger than the electrical resistance on the side wall.

Current Path on the side wall The resistance on the side wall is R w b/t w The resistance on the crack is Rd/ax

Current Path on the side wall (Continue) In which R w is the electrical resistivity of the wall material b is the dimension of the channel perpendicular to the field. t w is the wall thickness R is the electrical resistivity of the coolant d is the coating thickness a is the half width of the channel parallel to B x is the fraction of the crack.

Current Path on the side wall (Continue) For the channel to act as insulated channel, the resistance has to be dominated by the crack, or Rd/ax >> R w b/t w Rd/ax >> R w b/t w R is 0.25X10 -6, d is 10 micro, t w is 1mm, a is 5cm, R w is 10 -6, and b is 10 cm. Therefore, X is << 5X10 -7 X is << 5X10 -7

Current Path on the side wall (Continue)

Conclusion For the wall to act like a perfectly insulated wall, the fraction of the crack on the wall has to be less or about For the wall to act like a perfectly insulated wall, the fraction of the crack on the wall has to be less or about If the cracking fraction is higher than 10 -7, the wall will act like a perfect conducting wall. If the cracking fraction is higher than 10 -7, the wall will act like a perfect conducting wall. Question: Can we develop and maintain an insulated wall with a cracking fraction below ? Question: Can we develop and maintain an insulated wall with a cracking fraction below ?

Possible Solutions Possible Solutions * Develop a self-healing coating. * Develop a self-healing coating. * Develop a laminated wall system. * Develop a laminated wall system. * Investigate the contact resistance between the liquid and the wall. * Investigate the contact resistance between the liquid and the wall. * Investigate designs which can accept higher crack fraction. * Investigate designs which can accept higher crack fraction.