TOPICS IN (NANO) BIOTECHNOLOGY Immunosensors 30th June PhD Course.

Slides:



Advertisements
Similar presentations
Research Techniques Made Simple: Enzyme Immunoassay and ELISA
Advertisements

Capability of Immobilisation techniques and detection of Ab-Ag interactions by Eyad Hamad November 2010.
Applied Biotechnology Innovation Centre Electrochemical Nanopatterning and Microsystems Ioanis Katakis Department of Chemical Engineering, ATIC Technology.
Dr. Marc Madou Class IV. Microfabrication of electrochemical sensors Winter 2011 BIOMEMS.
ELISA Enzyme Linked Immunosorbent Assay. Definitions  Antibodies (also known as immunoglobulins abbreviated Ig) are gamma globulin proteins that are.
1 Lecture: Forensic Serology - Immunoassays Antibody/Antigen reaction provides the means of generating a measurable result. “Immuno” refers to an immune.
Part Three Basic Test Methods
Immune Testing.
Immunolabeling Technique
Module Two Labeled Test Methods
© 2004 Wadsworth – Thomson Learning Immunology Tutorial Introduction & Course outline By: Moh’d J. Al Khatatneh.
NSF-ITR Meeting Miniaturized Sensors Air molecules aerosols Water molecules cells, viruses.
Introduction to Immunoassays
ELECTROCHEMICAL BIOSENSORS Modern and future approaches to medical diagnostics J. F. Rusling Dept. of Chemistry Dept. of Pharmacology, Univ. of CT Health.
The purpose of this work was the development of a disposable electrochemical immunosensor based on screen-printing technology for measurement of AFM1 in.
Altogen Labs, 4020 S Industrial Dr, Suite 130, Austin TX 78744, USA  ELIS A Enzyme-Linked Immunosorbent Assay ELISA.
Radioimmunoassay & Enzyme Linked Immunosorbent Assay
Department of Biotechnology and Microbiology
(Enzyme Linked Immunosorbent Assay)
Biosensor for Detecting Mycotoxins in Grains Sundaram Gunasekaran University of Wisconsin-Madison In collaboration with Senay Simsek North Dakota State.
Antigen antibody reactions
Lec 16 Medical biotechnology Shah Rukh Abbas, PhD
CLS 420 Clinical Immunology & Molecular Diagnostics
ELISA Equipment. INTRODUCTION TO ELISA ELISA, or Enzyme-Linked Immunosorbent Assay, are immunological procedures used to determine the presence of antibodies.
Enzyme-Linked Immunosorbent Assay
1 CLINICAL CHEMISTRY CHAPTER 6 IMMUNOASSAYS. 2 Introduction –In the last chapter, we discussed a variety of analytical techniques –In this chapter we’ll.
Western Blotting.
WHAT IS A WESTERN BLOT?.
Immunology Chapter 6, Lecture 2 Richard L. Myers, Ph.D. Department of Biology Southwest Missouri State Temple Hall 227 Telephone:
Enzyme-Linked Immunosorbent Assay [ELISA] BCH 462[practical] Lab#5.
Microscopy Special Techniques in Microscopy: Immunohistochemistry.
Immunochemical methods
Definitions  Antibodies (also known as immunoglobulins abbreviated Ig) are gamma globulin proteins that are found in blood and are used by the immune.
BioSensors Yang Yang 9/28/2004. Outlines BioMEMS Enzyme-coated carbon nanotubes Microcantilever biosensor with environmentally responsive hydrogel Cantilever.
MLAB 2401: Clinical Chemistry Keri Brophy-Martinez Immunoassays 1.
1 Immunoassay Testing Forensic Toxicology. 2 Introduction Antibody/Antigen reaction provides the means of generating a measurable result. “Immuno” refers.
Ex. 27: HIV ELISA, AIDS Diagnostic Tool. Human Immuno- deficiency Virus (HIV) First diagnosed in 1981 Over 20 million deaths worldwide, over a half million.
It's usually difficult to identify a protein of interest in a Commassie Blue-stained gel of cell extracts Coomassie Blue-stained gel MW stds. Cell extracts.
The Enzyme Linked Immunosorbent Assay (ELISA).. Capture ELISAs Antigen Capture: In this, more specific approach, a capturing Ab is adsorbed onto the solid.
LABORATORY METHODS BASED ON ANTIGEN-ANTIBODY INTERACTIONS I
A.) Introduction : 1.) Coulometry: electrochemical method based on the quantitative oxidation or reduction of analyte - measure amount of analyte by measuring.
1 Immunochemical assays Seminar No. 7 - Chapter 23 -
Real Time Electrochemical Displacement Immunosensor for TCA detection María Viviana Duarte 2nd year PhD Student Project thesis course January 2004.
Lecturer: David. * Reverse transcription PCR * Used to detect RNA levels * RNA is converted to cDNA by reverse transcriptase * Then it is amplified.
Western Blotting. Introduction … Western blotting, also known as immunoblotting or protein blotting, is a technique used to detect the presence of a specific.
Biochemical instrumental analysis - 12 Dr. Maha Al-Sedik 2015 CLS 332.
Enzyme Linked Immunosorbent Assay
ELISA Enzyme Linked Immunosorbent Assay Fariba mazrouei.
What is immunoassay? The term “immunoassay” is a combined term of “immuno” (= antigen-antibody-reaction) and “assay” (= determination of the amount of.
SCI3023 ELECTROCHEMISTRY Chapter 8e: Potentiometry
Telephone    Provider of Global Contract Research Services Accelerating Preclinical Research, Drug Discovery.
© 2004 Wadsworth – Thomson Learning Chapter 19 Diagnostic Immunology.
ICC Immunocytochemistry
ELISA BASICS.
GENE EXPRESSION STUDY ON PROTEIN LEVEL
Telephone    Provider of Global Contract Research Services Accelerating Preclinical Research, Drug Discovery.
Immunoassays are tests that take advantage of the specificity of antibodies to their protein epitotes. Qualitative example: pregnancy test kits, HIV.
Biosensors Definition
BIOELECTRONICS 1 Lec 5: Potentiometric Biosensors By
Enzyme Linked Immunosorbent Assay
Fluorescence Polarization Immunoassay FPIA
Labeled Immunoassays.
ELISA BASICS.
Blot, Blot, Western Baby Kristin B. Dupre June 30th, 2011.
Immunolabeling Technique
ELISA Immuno ExlorerTM HIV/AIDS Diagnostic Tool
Immunochemical methods
Enzyme Linked  Immuno sorbent  Assay  
Experimental Systems and Methods
Practical of Histopathology
Presentation transcript:

TOPICS IN (NANO) BIOTECHNOLOGY Immunosensors 30th June PhD Course

Overview Last week we looked at what is DNA and what is a gene. We also looked at DNA replication and protein synthesis, and the path from the gene to protein This week we will look at Recombinant DNA technology We will also look at the amplification of DNA and finally at its sequencing

Immunosensors

What is an antibody?

How do we produce polyclonal and monoclonal antibodies? Polyclonal antibodies - larger quantities may be produced at a time - sometimes better selectivity and sensitivity due to recogintion of multiple epitopes - no guarantee of batch to batch reproducibility Monoclonal antibodies - long and expensive process - sometimes lower selectivity and sensitivity in comparison to Pabs observed - once cell line established constant reproducible supply of antibodies …. forever

Sandwich assay substrate product substrate product substrate product Concentration Response Useful for large molecules Robust assay - all reagents in excess Use with Pabs or different MAbs

Competition assay substrate product substrate product Concentration Response Useful for small molecules Reportedly less sensitive Concentrations of reagents critical

Displacement assay substrate product substrate product Concentration Response One step assay In practise difficulties to achieve - effect of non specific displacement Sub-optimum haptens met with some success

History of immunosensors Fluorescence polarisation labeled Ab and Ag First voltammetric immunosensor (Purdy et al) Use of FITC First PZ immunosensor (Shons et al) First potentiometric immunosensor (Janata) First report of EIA (Rubenstein et al) First amperometric immunosensor (Aizawa) First fluorescence immunoassay

Electrochemical transduction

Duan & Meyerhoff, 1994 Gold coated microporous nylon membranes, serving as solid phase and working electrode Ab immobilised via SAM of thioctic acid on gold side of membrane Separation free sandwich assay - surface bound spatially resolved from excess conjugate in bulk Substrate introduced through back side of porous membrane Substrate diffuses rapidly through membrane first encountering ALP-Ab Enzymatically generated product detected immediately via oxidation at gold electrode Assay time of 30 minutes, measurement of 1 minute

Skladal et al, 1995

Bauer et al, 1996 FIA system using bienzyme recycling for detection of 2,4-D Clark-type electrode covered by membrane with PPO and PQQ-GDH 350-fold amplification observed 60 minute incubation with PP and zeptomole detection

Lu et al, 1997 Electrically wired amperometric immunosensor Demonstrated for detection of biotin Redox polymer and antibody co-immobilised and competitive assay for biotin Only surface bound biotin-HRP ‘wired’ L.O.D. One order of magnitude better than ELISA

Rishpon & Ivnitski, 1997 Separation free enzyme channelling immunosensor Graphite pencil, E app = 0.0V Poly(ethylene)imine film to discriminate surface bound and bulk HRP Formats with I 2, aminosalicylic acid minute assay

Keay & McNeil, 1998 Separation free immunosensor based on enzyme channelling Ab immobilised on Biodyne C membrane on SPEs 15 minute assay time, L.O.D mg/L (12 p.p.t)

Wang, Tian & Rogers, 1998 Bi3+ Bi Bi3+ 3é StrippingDeposition Potentiometric stripping analysis HSA used as model analyte Bismuth metal ion label 30 minute incubation HCl and Hg+ added to release metal label 10 minute deposition

Bäumner & Schmid, 1998 Pioneering work patented by Durst (1996) Hapten tagged liposomes containing ascorbic acid Competition, - unbound labeled hapten passes detergent loaded membrane - releases ascorbic acid for electrodetection Ascorbic acid released SIGNAL

SmartSense TM Ohmicron Co SmartSense Atrazine at p.p.b. Levels 15 minute assay time

Dequaire et al, 1999 Sample and 2.4-D-ALP added to microwell-electrode format - 40 minute incubation Microwell-electrode format supported on magnet holding block Beads magnetically separated for 3 minutes and excess liquid removed Phosphoric acid ester of [[(4-hydroxyphenyl)amino]- carbonyl]cobaltecium hexafluorophosphate used as substrate Cationic phenol accumulated in Nafion film for 30 minutes L.O.D. of 10ng/L (p.p.t) of 2.4-D

Campbell et al, 1999 Ingenious assay - separation and reagentless immunosensor Choline oxidase does not interact with wire - produces H 2 O 2 to act as substrate for HRP Washing not required as only surface bound HRP will be wired to electrode surface ChOX and avidin immobilised on redox hydrogel followed by biotinylated specific antibody An 18 minute assay - demonstrated with IgG

Kim et al, 2000 Attempted electrochemical detection of traditional immunochromatographic strips by measuring change in conductance upon aggregation of colloidal gold labels Direct detection - low sensitivity Used gold colloids coated with polyaniline Large improvement in sensitivity Demonstrated with HSA 6 minute assay time

Benkert et al, 2000 Anti-analyte antibody Redox labeled analyte Analyte Size exclusion layer MWCO 20,000 SERI - size exclusion redox-labeled immunoassay Analyte competes with redox-labeled analyte for antibody binding Unbound redox-labeled passes therough the size exclusion layer and is indicated electrochemically Demonstrated with creatinine - low L.O.D.

Yang et al, 2001 Layer by layer (LbL) approach Applied to enyme and immunosensors Platform for fluorsecent immunosensors Deposition of IgG PS MicroparticleDye-labeled PS microparticleIgG conjugated dye-labeled PS microparticle Consecutive assembly of PAH- FITC and PSS

Katz et al, 2001 Sensing antibody using antigen monolayer electrode and anti idiotypic-HRP Biocatalytic precipitation of insoluble product - forms an insulating layer on electrode surface, decreases interfacial electron transfer rate constant Chronopotentiometry - measurement time of seconds, Faradaic impedance spectroscopy - 15 to 20 minutes

O’ Sullivan & Katakis, 2001 Quasi counter – reference Ag/AgCl electrode Carbon working electrode Insulation Layer Area for sample application Competitive assay - immobilised antigen, labeled antibody Originally used ALP label and p-APP substrate - 22 minute assay time, mainly due to substrate development Using Os-amine mediator and HRP label assay time of 10 minutes

Market drivers The market drivers for the biosensors market, in order of impact, are:  high demand,  expanding application areas  high levels of research & development  advancing technologies reducing production costs  increased customer awareness  legislation  integrating partnerships between academia and industry  innovative new product developments  strong economy

Market predictions to 2004 Biosensor Market Segments (Frost & Sullivan, 1998) Medical applications will continue to dominate Overall best growth rate of 6.8% predicted for environmental biosensors as applications will be realised for site characterisation and clean-up Growth attributed to development of immunosensors