Lecture 6 ATOMIC SPECTROSCOPY
Advertisements

Atomic Absorption & Emission Spectroscopy
1.1 Atomic Absorption Spectrometry (AAS) determination of elements not compounds needs radiation source high temperature for atomization Atomization a.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Chapter 8 & 9 Atomic Absorption Spectroscopy
427 PHC. Direct-Current Plasma  A direct-current plasma (DCP) is created by an electrical discharge between two electrodes. A plasma support gas is necessary,
1 Atomic Absorption Spectroscopy Atomic Emission Spectroscopy Lecture 18.
Atomic Absorption and Atomic Fluorescence Spectrometry Wang-yingte Department of Chemistry
Metal Analysis by Flame and Plasma Atomic Spectroscopy Flame A. Atomization 1. Types of Atomization Processes a.) Nebulizers b. Electrothermal atomization.
AAS and FES (Ch 9, 7th e, WMDS)
AA and Atomic Fluorescence Spectroscopy Chapter 9
Atomic Spectroscopy Atomic Spectroscopic Methods Covered in Ch 313: Optical Atomic Spectrometry (Ch 8-10) Atomic X-ray Spectrometry (Ch 12) Atomic Mass.
INTRODUCTION TO OPTICAL METHODS
Atomic Absorption Spectroscopy AAS Comparatively easy to use Low maintenance Low consumables Good for measuring one element at a time. Comparatively easy.
Atomic Absorption Spectrometry Dr AKM Shafiqul Islam University Malaysia Perlis.
1 Atomic Absorption Spectroscopy. 2 Atomic Transitions: Excitation and Emission.
Flame photometry.
Molecular Fluorescence Spectroscopy
Atomic Emission Spectroscopy
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Atomic Absorption Spectroscopy (AAS)
Atomic Emission - AES M* → M + hn Thermal excitation M → M*
Atomic spectra are a result of energy level diagrams - quantum theory.
Atomic Absorption Spectroscopy (AAS)
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Atomic-Absorption (AA) Spectroscopy 
OPTICAL ATOMIC SPECTROMETRY Chap 8 Three major types Optical spectrometry Optical spectrometry Mass spectrometry Mass spectrometry (X-ray spectrometry)
Instrumental Chemistry
Atomic Absorption Spectroscopy
ATOMIC ABSORPTION SPECTROSCOPY
BC ILN Atomic Absorption Spectroscopy (AAS) 1 Thompson Rivers University.
Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh
Chapter 8 An Introduction to Optical Atomic Spectroscopy
Atomic Emission Spectroscopy
Atomic Emission Spectrometry
Atomic Absorption Spectroscopy
Atomic Absorption Spectrometry
AAS Atomic Absorption Spectrophotometry. AAS – Widely in clinical laboratories to measure elements such as aluminum, calcium, copper, lead, lithium, magnesium,
1 Atomic Emission Spectroscopy Lecture Advantages of Plasma Sources 1.No oxide formation as a result of two factors including Very high temperature.
1 Atomic Absorption Spectroscopy Lecture Performance Characteristics of Electrothermal Atomizers Electrothermal atomization is the technique of.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 20
to Optical Atomic Spectroscopy
Atomic spectroscopy Elemental composition Atoms have a number of excited energy levels accessible by visible-UV optical methods ä Must have atoms (break.
1 Introduction to Atomic Spectroscopy Atomic Absorption Spectroscopy Lecture 12.
Adv. Inst. Techs.  flame emission (eg flame photometer) known as low temperature emission ( K) ◦ first form of spectroscopy ◦ used in commercial.
Beers Law for a Single Component Sample I0I0 A = Absorbance = - log 10 I I / I 0 b = Optical path length c = Solution Concentration (M/L) ε = Molar Absorptivity.
Atomic Fluorescence Spectroscopy. Background l First significant research by Wineforder and Vickers in 1964 as an analytical technique l Used for element.
Atomic-absorption spectroscopy
ATOMIC ABSORPTION SPECTROSCOPY (AAS) Atomization: It is the conversion of molecules to their component atoms in gaseous state using a source of heat (flame).
1 Atomic Emission Spectroscopy Molecular Absorption Spectroscopy Lecture 21.
A TOMIC - ABSORPTION SPECTROSCOPY. Atomic absorption spectroscopy (AAS) is a technique for determining the concentration of a particular metal element.
Atomic-absorption spectroscopy Lab3 Atomic-absorption spectroscopy.
A TOMIC - ABSORPTION SPECTROSCOPY Lab no. 3 Done by : Iman Al Ajeyan.
Chem. 133 – 4/4 Lecture. Announcements I Strike – If the strike occurs, it will affect classes April 14 th and 18 th (unless ended early) – Lab: would.
Chemistry 4631 Instrumental Analysis Lecture 18 Chem 4631.
Atomic Spectroscopy Flame emission spectroscopy (FES)
Chapter 28 Atomic Spectroscopy.
Chem. 133 – 4/4 Lecture.
ATOMIC ABSORPTION AND ATOMIC FLUORESCENCE SPECTROMETRY
Flame Emission Spectrometry
Flame Photometer.
Chem. 133 – 3/30 Lecture.
Atomic Absorption and Atomic Fluorescence Spectrometry
The ratio of excited state to ground state atoms as a function of temperature is determined by the Maxwell-Boltzmann expression. Fig Excited state.
Introduction to Atomic Spectroscopy
Elemental composition
Atomic Absorption and Atomic Fluorescence Spectrometry
Chapter 8 An Introduction to Optical Atomic Spectroscopy
Пламена Спектроскопија
Atomic Absorption Spectroscopy. Atomic absorption spectroscopy is based on the same principle as the flame test used in qualitative analysis.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Presentation transcript:

announcements and reminders Homework #2 due Wednesday September 27 problems: chapter 7(15(a,c,f and g) , 19 and 22) chapter 8(4,5,7 and 8) last lecture: optical instruments intro atomic spectroscopy today’s lecture: atomic spectroscopy and start 1st inst: AAS

Effect of Temperature Boltzmann Equation Example 8-2: Ratio of Na atoms in the 3p excited state at 2500 K (Acetylene/Air) = 1.72 10-4 Change in number of excited atoms for 10 K = 4%

Band and Continuum Spectra Band spectra – the additional vibrational and rotation energy levels of simple molecules (e.g., CaOH) result in broad (a few nm) spectral features Continuum Spectra – particulate matter within flame acts as a source of black body radiation

Sample introduction Nebulization Electrothermal Vaporizer sample is converted into a mist of finely divided droplets (aerosol) Electrothermal Vaporizer sample is vaporized and atomized within a closed tube that is electrically heated at temperatures up to 3000 K (page 203)

Chemical conversion convert sample into a volatile molecular species that is more efficiently atomized. hydride generation (page 203) As-cmpds + NaBH4 → AsH3 cold vapor AAS Hg-cmpds and ions + SnCl2 → Hg0 US EPA Method 1631

Solid Samples Electrothermal Ablation sample is vaporized and atomized within a closed tube that is electrically heated at temperatures up to 3000 K (page 203) Ablation high energy discharge (electrical spark or arc; laser pulse) causes a plume of particulate and vaporized matter to be ejected from a solid surface.

Direct Sample Insertion Glow Discharge low pressure plasma in contact with the sample sputters the sample atoms (~0.1mg/min) Direct Sample Insertion self evident

AAS Flame AAS: 1% precision possible (2-3% typical) Useful for ~60 metals and metalloids Detection limits 1-20 ppb typical, depends on element Linear Dynamic Range: ~one order of magnitude Matrix effects: significant ~$30,000

flame processes Oxidation: atoms metal oxides (secondary combustion zone; yellow) Ionization: neutral atoms ions (interzonal region; measurement zone) Excitation - atom is thermally excited into a higher energy state Dissociation: molecules atoms (primary combustion zone; blue) Volatilization: salt particles gaseous molecules Desolvation: spray salt particles Relative importance of these processes depends upon: element flame temperature Hydrogen-Air 2000-2100 C GC detectors Acetylene-Air 2100-2400 C Best for non-refractory elements Acetylene-N2O 2600-2800 C Best for refractory elements

electrothermal AAS sample is vaporized and atomized within a closed tube that is electrically heated to 3000 K add-on to flame AAS Precision: 5-10% Matrix effects: severe Sample required: L Detection limits: 0.002-0.01 ppb Better because holds atoms in light beam longer

electrothermal process Drying- removes solvent eg, 125C for 20 s Charring (Ashing) – destroy organic matter smoke cause strong signal (not related to concentration) eg., 1400 C for 60 s Atomize - rapidly vaporize sample and break it down to atoms rapid heating to 2000-3000C yields a transient signal (<1 second)

Chemical conversion convert sample into a volatile molecular species that is more efficiently atomized e.g., hydride generation As-cmpds + NaBH4 ➔ AsH3 continuous signal (although the magnitude and temporal dependence will depend upon the reaction kinetics)

hollow cathode lamp emits sharp atomic lines characteristic of the element from which the cathode is made simplicity of HCL spectra means that a low resolution monochromator can be used

background correction two line continuum Smith-Hieftje (self reversal)

Zeeman background correction moderate field (10kGauss) transitions split to satellite and main absorption of atoms only occurs when polarization is parallel to magnetic field

Questions about AAS Question: why is monochromator after the flame? Question: What about flame light that is at the same wavelength as is being measured?

AAS summary Advantages of AAS: very sensitive (ppb detection limits) useful for a wide range of metals relatively inexpensive (~$30,000) When is AAS the preferred technique? Low concentration of metal ions in aqueous solution If you are interested in only a few metals (6) If sample volume is very small (<1 mL), electrothermal atomic absorption is best Disadvantages of AAS: limited dynamic range (need to know conc you are looking for) Subject to numerous types of intereference (flame and furnace)

basic properties quantification of nearly 70 elements ppb - weight percent microliter or microgram (furnace) milliliter (flame) biomedical, environmental, steel and metal, pharmacy, food, pollution and industrial monitoring solid liquid or gas minimal sample prep sample prep 0sec to 24hrs, measurement (seconds (flame) minutes (furnace)) no chemical info (only elemental composition) destructive more appropriate for few elements at a time (not easily applied to multielement problems) accuracy (homogeneous solution 5-10 x detn limit (accuracy ~1%) (direct solids accuracy ~5-10%) linear dynamic range usually 2 orders of magnitude (sometimes 3)

AAS costs simple no bkgd corr ($10k) full package ($100k) lamps (single element($150-$400) multielement($300-$400)) last ~200hrs of continuous emission gases typically run $120/year graphite tubes ($20-$50/ea) last ~200 firings heavily used system may cost $1-$2000/year for operations full service contract typically will run $6000/yr