Math for Water Technology MTH 082 (pg. 468)

Slides:



Advertisements
Similar presentations
Amherst , MA, Drinking Water System Atkins Water Treatment Plant
Advertisements

Drinking Water Treatment Seminar Leesville Middle School
Arsenic/Iron Co-Precipitation and High Rate Filtration in the City of Portage Christopher Barnes, P.E., City of Portage Kendra Gwin, P.E., City of Portage.
Often water is prescreened, treated with ozone, or pre-chlorinated before entering the coagulation basin (depending on the quality of the water). Coagulation.
DISINFECTION.
Basic Math Area Formulas
CE 370 Sedimentation.
Biological waste water treatment
C. T Calculation Math for Water Technology MTH 082 (pg. 468) Math for Water Technology MTH 082 (pg. 468) “Required by Law”
Introduction to Septic Tanks John R. Buchanan, Ph.D., P.E. University of Tennessee.
An-Najah National University Civil Engineering Department
FE Review for Environmental Engineering Problems, problems, problems Presented by L.R. Chevalier, Ph.D., P.E. Department of Civil and Environmental Engineering.
Math Basics I Area, Volume, Circumference, Converting Inches to Feet, Converting Flow, Converting Percent/Decimal Point, Decimal Point, Detention Time.
Surface Water Treatment Plant
Discharge Monitoring Reports (DMRs)
WASTE STABILIZATION POND (WSP). Advantages:Simplicity simple to construct simple to construct simple to operate and maintain simple to operate and.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Reactors The Case of the Chlorine Contact Tank.
Wastewater Treatment Plants & Bacteria: Strategies for Compliance Chlorine Contact Chambers; Chlorine Mixing and Contact Time for Ct Harris County Wastewater.
Surface Water Treatment Rule Bob Clement Drinking Water Program U.S. EPA Region 8.
Well Disinfection Math for Water Technology MTH 082 Lecture
Water Treatment System Design for Cinnamon Creek Campground Nomads Engineering: Achit-Erdene Gankhuyag Cuyler Frisby Kevin Wagner.
REPORTING REQUIREMENTS. Overview How to fill out the monthly SWTR operating reports –How often to record turbidities –Highest turbidity of the day –Peak.
Sustained Compliance Workshop - Anchorage, AK September 23-24, 2010 Eric Burg Kenai Peninsula & Southeast Alaska – Compliance & Monitoring Section DEC.
Groundwater Math Math for Water Technology MTH 082 Lecture 2 Well Drawdown, Well yield, Specific Capacity, Well Disinfection Course Reader Week 2 Chapter.
Filter Loading and Backwash Rates Well Yields and Chlorine Dosage in Waterworks Operation Math for Water Technology MTH 082 Lecture Chapter 4 & 8- Applied.
Water Treatment for NYC Croton Schematic. NYC Filtration Plant for Delaware and Catskill Systems  Filtration avoidance criteria  Alternatives to Filtration.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Multiple Barriers, Multiple Exposures Perspectives from the North and the South.
Flow From a Faucet, Flushing a Service Line, 90 th Percentile Lead and Copper Rule, Copper Sulfate Application Rates in Waterworks Operation Math for Water.
Water Treatment for NYC Croton Schematic. NYC Filtration Plant for Delaware and Catskill Systems ä Filtration avoidance criteria ä Alternatives to Filtration.
Basic Hydraulics of Flow (Pipe flow, Trench flow, Detention time)
NYC Filtration Plant for Delaware and Catskill Systems ä Filtration avoidance criteria ä Alternatives to Filtration? ä Where should the plant(s) be located?
Basic Math Conversions Math for Water Technology MTH 082 Fall 08 Chapters 1, 2, 4, and 7 Lecture 1 Math for Water Technology MTH 082 Fall 08 Chapters 1,
Basic Math Midterm Review Math for Water Technology MTH Math for Water Technology MTH
Math Midterm Review Math for Water Technology MTH 082.
Math Final Exam Review Math for Water Technology MTH 082.
Basic Hydraulics Irrigation.
Module 4: Fundamentals of Wastewater Treatment Wastewater Treatment Plant Operator Training.
1 Chlorine Contact Time / Virus & Giardia Log Removal Credit Calculations The EPA Guidance Manual on the Surface water Treatment Rule and Disinfection.
WASTEWATER STABILIZATION LAGOON PROCESS
Effective Use Of Peracetic Acid to Reduce Effluent Disinfection Byproduct in Water Resource Recovery Facilities Isaiah Shapiro, EIT Dimitri Katehis PhD,
SEAVURIA Seattle + Kenya (2012)
REPORTING REQUIREMENTS. Overview How to fill out the monthly SWTR operating reports –How often to record turbidities –Highest turbidity of the day –Peak.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Reactors The Case of the Chlorine Contact Tank 
CTC 450 Review Water processing.
DAF System Air Supply Pressurizing Pump Retention Tank
Dr. Joel J. Ducoste, North Carolina State University, 1 Importance of water “Water is life” Looking at water, you might think that it's the most simple.
$200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 MCLsMonitoring RulesReporting.
DECENTRALISED WASTEWATER TREATMENT AND REUSE Components and Designing
State of Alaska Implementation of MBDP Rules Carrie Bohan Environmental Program Specialist ADEC DW Program.
Christopher Hill December 6, 2006 CE 679
Instructors: Greg & Patresha Pearson, RN; CSUS-OWP Instructors © GREPA Health & Environmental – All rights reserved Drinking Water Workshops Essential.
5.6 SEDIMENTATION Objective
Kinetics of Disinfection Ideally:All cells equally mixed with disinfectant All cells equally susceptible to disinfectant. Disinfectant concentration unchanged.
1 III. Water Treatment Technologies Topic III. 6. Water Disinfection: Reagents, Processes and Equipment Reagents §Chlorine and Cl-compounds l Very effective.
Leah Guzman and David Edmunds Environmental Program Specialists The Ground Water Rule Workshop Department.
DISINFECTION CE326 PRINCIPLES OF ENVIRONMENTAL ENGINEERING
SATMathVideos.Net Water is pumped into an tank at 20 gallons per minute. The tank has a length of 10 feet and a width of 5 feet. If the tank starts empty,
CTC 450 Review WW Collection Systems Types of pipes Installation.
16 – Measurement of Flows in Piping Systems 1 March 14, 2013 Professor Doran CEE 410.
Amherst , MA, Drinking Water System Atkins Water Treatment Plant
CTC 450 Review Water processing.
CT Values Dan Lanteigne
DAF System Air Supply Pressurizing Pump Retention Tank
Treatment – Chlorine Disinfection
Pilot testing services and a case study to reduce organics Devendra Borikar, Laura Zettler, Jeff Avedesian, Lindsay Ariss, Luc Léonard, Denis Dolbec,
Three choices: Surface water Groundwater
Clarifier Calculations Prepared By Debremarkos Department of HWRE Water treatment unit.
5.7 Flocculation   Flocculation is the process of gentle and continuous stirring of coagulated water for the purpose of forming flocs through the aggregation.
  5.6 Rapid mix Rapid mixers should provide sufficient agitation to disperse the coagulant in raw water. Rapid mixing units can be classified according.
Trihalomethanes Removal Evaluation
Presentation transcript:

Math for Water Technology MTH 082 (pg. 468) C.T Calculation “Required by Law” Math for Water Technology MTH 082 (pg. 468)

C.T calculation “C” is the concentration of chlorine, “T” is the amount of time the water has been in contact with chlorine before the first user. Calculated daily and compared against the EPA CT “Required” Table EPA rules states - “Measurements must be taken on the same day of the week, every week, for one year (52 measurements), during peak hourly flow for that day. Data can be measured manually or with on-line instrumentation.”

C.T calculation Surface Water Treatment Rule: all surface water and GWUDI systems require 99.9% (3-log removal) and/or inactivation of Giardia and 99.99% (4-log) removal of viruses through disinfection and treatment Ground Water Treatment Rule: If a system is fecal positive may be required to achieve inactivation of 99.99% (4-log) removal of viruses through disinfection and treatment

C.T Calculation Problems To calculate the contact time T, the results of a recent tracer study must be used!! The peak flow must be measured from the effluent side of the clearwell or contact chamber, NOT the flow through the plant. The chlorine residual, pH, and temperature values used to calculate CT must be measured at the effluent side of the clearwell or contact chamber, or before the first user.

CT Calculation Problems When using the EPA CT tables, make sure you round down for temperature, and round up for pH. log-reduction must equal 3.0 for Giardia

For surface water systems without filtration, the Surface Water Treatment Rule requires public water systems to? Provide coagulation and filtration Maintain a C X T value above the minimum value Continuously sample for total coliforms Maintain public notification

In the application of chlorine for disinfection, which of the following is not normally an operational consideration? Mixing Contact time Dissolved oxygen pH None of these answers are correct

The chlorine residual, pH, and temperature values used to calculate CT must be measured at? effluent side of the clearwell effluent side of the contact chamber before the first user Any of the above would be ok

The C.T calculation must be calculated Once a year Once a month Once a week Once a day

The peak flow must be measured as total flow through the plant? True False

The final C.T calculation has what units? Mg/L Lbs/day mg-min/L time

What is the acceptable log reduction for Giardia? 1 2 3 4

What is the acceptable log reduction for viruses? 1 2 3 4

Four log removal is? 90.00 % 99.00 % 99.90 % 99.99 %

If your temperature is 8 degrees with a pH of 7 If your temperature is 8 degrees with a pH of 7.2, you should use the ____ degree page and the _____ pH table (please look at your tables). 5, 19 10, 8.5 5, 7.5 10, 7

Disinfection CTs have been established for? Free chlorine Chloramine Chlorine dioxide Ozone All of the above

Disinfection C.T are impacted by which of the following? Chlorine residual concentrations (mg/L) Contact Time (min) Water Temperature Water pH All of the above

T =contact time= Detention Time C.T Calculation T =contact time= Detention Time “the length of time water is retained in a vessel or basin ”

The units of T in the final CT calculation are ? Seconds Minutes Hours Days

Want T value to be in minutes Determining T in CT? Detention time (DT) = volume of tank = MG (1440min) flow rate MGD (1day) Want T value to be in minutes T = volume X Baffle Factor (table) flow rate

Baffle Factor? Poor circulation Baffling efficiency = 5-10% out Poor circulation Baffling efficiency = 5-10% in out No circulation Baffling efficiency = 0% in out

Baffle Factor? No circulation Baffling efficiency = 0% Good circulation Baffling efficiency = 30-50% in out in out Superior circulation Baffling efficiency = 70%

Baffle Factor? Perfect circulation Baffling efficiency = 100% out Poor circulation/hydropneumatic tank Baffling efficiency = 10% in out No circulation/Bladder type pressure tank Baffling efficiency = 0%

Baffle Factor? Unbaffled Tank 0.1 Poor Baffling 0.3 Average Baffling 0.5 Superior baffling 0.7 Pipe Flow 1.0 “How well the chlorine is in contact with the water”

What is the average detention time in a basin that is 1240 ft3 when the flow rate is 4.1 MGD? 3.3 min .03 min 303 min 435,512 min

What is the average detention time in a basin given the following: diameter = 80' depth = 12.2' flow = 5 MGD 132 min 101 min 144 min 105 min

Determine T at the effluent side of a superior baffled contact chamber basin that has the following: diameter = 30' depth = 15' flow = 700 gpm 65.8 min. 79.1 min 75 min. 86.1 min.

96.17 min 67.32 min 12.85 min 9 min DRAW: Given: Formula: Solve: Determine T at the effluent side of a superior baffled contact chamber basin that has the following: Length of = 30ft, width of 20 ft, depth = 15' flow = 700 gpm? DRAW: Given: Formula: Solve: tank= L X W X D , Flow rate 700 gpm, BF=0.7 T= DT X BF T= volume of tank/flow rate X BF Vt= L X W X D Vt=30 ft X 20 ft X 15 ft= 9000 ft3 9000 ft3 (7.48 gal/1ft3)= 67320 gal DT=VT/FR X BF Time = 67,320 gal/700gpm X 0.7 Time= 96.17 min X 0.7 Time= 67.32 min in 700 gpm out 30 ft 20 ft 15 ft 96.17 min 67.32 min 12.85 min 9 min

Disinfection C•T Requirements Chlorine residual concentrations (mg/L) Contact Time (min) Water Temperature Water pH Disinfection power= [residual chlorine] • time of its contact

Disinfection C•T Calculation C•T= [disinfection concentration mg/L] • contact time (min) C•T units= mg/L• min or mg •min/L Required C•T CTrequired is # established by EPA to provide log inactivation. Based on Giardia cysts. Look up in charts Actual C•T CTactual is # established by multiplying actual chlorine residual by hydraulic detention time and baffle factor.

Disinfection C•T Calculation C•T actual =[Residual chlorine]•hydraulic detention time•baffle factor (table) Hydraulic detention time = volume/flow rate C•Tact/ CTreq= ratio must be > or = to 1. C•Tact/ CTreq > 1.0 “You want to make sure that you are actually meeting the necessary requirements”

Disinfection C•T Rules Chlorine residuals used for C•T calculations are measured after contact, but before first customer. 2. Contact times are determined by calculating the hydraulic detention time (HDT) as water flows through pipes and tanks. Based on highest flow of day.

Disinfection C•T Rules 3. Water flowing through pipes provides contact times that are equal to the calculated HDT. Circular or rectangular tanks used for contact time are given only partial credit due to short circuiting.

Removal Credits Requirements Viruses Table 7.2: Typical Removal Credits and Inactivation Requirements for Various Treatment Technologies Process Typical Log Removal Credits Resulting Disinfection Log Inactivation Requirements Giardia Viruses Conventional Treatment 2.5 2.0 0.5 Direct Filtration 1.0 3.0 Slow Sand Diatomaceous Earth Filtration Unfiltered 4.0 * Systems must demonstrate to the State by pilot study or other means that the alternative filtration technology provides the required log removal and inactivation shown in Table 7-1.