Test Results on the Photomultiplier Tubes for the ANTARES Neutrino Telescope Juan-de-Dios Zornoza IFIC (CSIC–Valencia University, Spain) On behalf of the.

Slides:



Advertisements
Similar presentations
COSMIC RAY MUON DETECTION USING SCINTILLATION COUNTER AND WAVELENGTH SHIFTING FIBERS ARUNODAYA BHATTACHARYA VSRP-2009,TIFR,MUMBAI 6/7/09.
Advertisements

The Multi-PMT Optical Module P.Kooijman, University of Amsterdam University of Utrecht Nikhef.
Prototype of the Daya Bay Neutrino Detector Wang Zhimin IHEP, Daya Bay.
Time-of-Flight at CDF Matthew Jones August 19, 2004.
Mechanical check of PMT Check base: Remove black tape and two small screws that secure the base. Tighten the nuts on the BNC connector for the HT input.
M. Palm, CERN1 Performance test of ACEM-detector (Aluminum Cathode Electron Multiplier) Marcus Palm AB-ATB-EA.
Basic Measurement of the Hamamatsu 10 inch PMT at –40 degree –40 degree Hiroko Miyamoto Dept. of Physics CHIBA University Angular Response of 10inch PMT.
Calibration of the 10inch PMT for IceCube Experiment 03UM1106 Kazuhiro Fujimoto A thesis submitted in partial fulfillment of the requirements of the degree.
Energy Reconstruction Algorithms for the ANTARES Neutrino Telescope J.D. Zornoza 1, A. Romeyer 2, R. Bruijn 3 on Behalf of the ANTARES Collaboration 1.
Genova/Pavia/Roma Flavio Gatti, PSI, July 1st, Timing Counter july 2004.
Prototype string for a km3 Baikal neutrino telescope Roma International Conference on Astroparticle Physics V.Aynutdinov, INR RAS for the Baikal Collaboration.
A feasibility study for the detection of SuperNova explosions with an Undersea Neutrino Telescope A. Leisos, A. G. Tsirigotis, S. E. Tzamarias Physics.
Measurement of the absolute efficiency,
1 Light Collection  Once light is produced in a scintillator it must collected, transported, and coupled to some device that can convert it into an electrical.
The ANTARES experiment is currently the largest underwater neutrino telescope and is taking high quality data since Sea water is used as the detection.
Photon detection Visible or near-visible wavelengths
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
Catania VLVnT09 Athens, Greece 1/14 Catania Performances of four super bialkali large area photomultipliers with respect to.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
Hanoi, Aug. 6-12, 2006 Pascal Vernin 1 Antares Status report P.Vernin CEA Saclay, Dapnia On behalf of the Antares collaboration P.Vernin
Leroy Nicolas, HESS Calibration results, 28 th ICRC Tsukuba Japan, August Calibration results of the first two H·E·S·S· telescopes Nicolas Leroy.
Coincidence analysis in ANTARES: Potassium-40 and muons  Brief overview of ANTARES experiment  Potassium-40 calibration technique  Adjacent floor coincidences.
Francisco Salesa Greus IFIC (CSIC–Universitat de València, Spain) Representing the KM3NeT Consortium 4 th International Workshop on Very Large Volume Neutrino.
1 S. E. Tzamarias Hellenic Open University N eutrino E xtended S ubmarine T elescope with O ceanographic R esearch Readout Electronics DAQ & Calibration.
1 Max-Planck-Institut fuer Physik, Muenchen, Germany, 2 Humboldt-Universituet Berlin, Germany, 3 Univ. Complutense, Madrid, Spain, 4 ETH, Zurich, Switzerland,
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
Ondřej Svoboda for the ECAL group HADES collaboration meeting XXV, 19 – 23 November 2012 GSI.
SINP MSU, July 7, 2012 I.Belolaptikov behalf BAIKAL collaboration.
Amsterdam 29 March 2011 Fernando Urbano IFIC (CSIC – Universidad de Valencia) KM3NeT Optical Calibration Laser Beacon and Nanobeacon Status.
FLC Group Test-beam Studies of the Laser-Wire Detector 13 September 2006 Maximilian Micheler Supervisor: Freddy Poirier.
Improved PMTs for the Cherenkov Telescope Array project Razmik Mirzoyan for the Focal Plane Instrumentation WG Max-Planck-Institute for Physics Munich,
U. Akgun, HCAL Fall Meeting, 11/11/2004, Fermilab, IL HF PMT ISSUES By Ugur Akgun The University of Iowa.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
Calibration Methods and Tools for KM3NeT V. Kulikovskiy on behalf of the KM3NeT collaboration.
Techniques for Nuclear and Particle Physics Experiments By W.R. Leo Chapter Eight:
Time over Threshold electronics for an underwater neutrino telescope G. Bourlis, A.G.Tsirigotis, S.E.Tzamarias Physics Laboratory, School of Science and.
Time Calibration with Optical Beacons Pylos, Apr 2007 C.Bigongiari IFIC Pylos, Apr 2007 C.Bigongiari IFIC (CSIC – Universitat de València)
Catania Study on large area photomultipliers with superbialkali photocathode E. Leonora 1, S. Aiello 1, D. Lo Presti 2, V. Giordano 1 1 INFN, section of.
Catania 11 ICATPP october, 2009 Como 1/12 Catania Comparative measurements of the performances of four super bialkali large.
Timing Studies of Hamamatsu MPPCs and MEPhI SiPM Samples Bob Wagner, Gary Drake, Patrick DeLurgio Argonne National Laboratory Qingguo Xie Department of.
Linearity Tests The laser induced high noise pulses on the APD rendering it useless. We tried several methods to shield and filter the noise. With a stabilized.
Cold PM test at Indiana final measurements, September 9 – 24, 2007 PM under test: Hamamatsu R7725 serial # ZK3692 (tube with Pt underlayer) Hans-Otto Meyer.
Latest progress in PMT development VLVnT11 in October, 2011 Hamamatsu Photonics K.K. Electron Tube Division Yuji Hotta.
Time and amplitude calibration of the Baikal-GVD neutrino telescope Vladimir Aynutdinov, Bair Shaybonov for Baikal collaboration S Vladimir Aynutdinov,
PMT measurements in Antares Oleg Kalekin on behalf of Antares collaboration VLVnT 2011 Erlangen
Calibration of Under Water Neutrino Telescope ANTARES Garabed HALLADJIAN October 15 th, 2008 GDR Neutrino, CPPM, Marseille.
Basic Measurement of the Hamamatsu 10 inch PMT at –40 degree –40 degree Hiroko Miyamoto Dept. of Physics CHIBA University The Uniformity measurement of.
A. Tsirigotis Hellenic Open University N eutrino E xtended S ubmarine T elescope with O ceanographic R esearch Reconstruction, Background Rejection Tools.
E. Picatoste, D. Gascon PMT afterpulsing and SPD trigger 1 Looking to the problem from the instrumentation point of view LHCb Calorimeter Meeting – CERN.
The VSiPMT: A new Generation of Photons Detectors G. Barbarino 1,2, F. C. T. Barbato 1,2, R. de Asmundis 2, G. De Rosa 1,2, F. Di Capua 1, P. Migliozzi.
Characterization of Hamamatsu R12199 PMTs Oleg Kalekin KM3NeT Meeting CPPM, Marseille
PMT AFTERPULSE STUDIES By Ugur Akgun The University of Iowa.
Silicon Photomultiplier Development at GRAPES-3 K.C.Ravindran T.I.F.R, OOTY WAPP 2010 Worshop On behalf of GRAPES-3 Collaboration.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
The photomultiplier tubes selection for KM2A electromagnetic particle detectors (EDs) hou chao IHEP The 2nd workshop of air shower detection at high altitudes.
Umberto Emanuele IFIC (CSIC-UV), Valencia (Spain) Status of Time Calibration System forKM3NeT.
KM2A PMT testing platform FENG Cunfeng, LI Chaoju, SUN Yansheng Shandong University THE 2 nd WORKSHOP OF AIR SHOWER DETECTION AT HIGH ALTITUDES IHEP, Beijing,
Status procurement of PMTs Oleg Kalekin KM3NeT WPF/L General Meeting Amsterdam
The dynamic range extension system for the LHAASO-WCDA experiment
Fabio, Francesco, Francesco and Nicola INFN and University Bari
Ultra fast SF57 based SAC M. Raggi Sapienza Università di Roma
ANTARES time calibration
Instrumentation for Colliding Beam Physics 2017
on behalf of the NEMO Collaboration
Department of Physics and Astronomy,
BESIII EMC electronics
Development of hybrid photomultiplier for Hyper-Kamiokande
Performance test of ACEM-detector (Aluminum Cathode Electron Multiplier) Marcus Palm AB-ATB-EA M. Palm, CERN.
Nanobeacon: A low cost calibration instrument for KM3NeT
Presentation transcript:

Test Results on the Photomultiplier Tubes for the ANTARES Neutrino Telescope Juan-de-Dios Zornoza IFIC (CSIC–Valencia University, Spain) On behalf of the ANTARES collaboration International Workshop on UHE Neutrino Telescopes Chiba, July 29-30, 2003

J. D. Zornoza - IFIC Contents  ANTARES experiment  PMTs specifications  Comparison of PMT candidates –Experimental setup at IFIC –Results –Conclusions  Tests on the Hamamatsu R –Experimental setup at DAPNIA –Results –Conclusions

J. D. Zornoza - IFIC ANTARES Detector  The detector will consist of a 3D matrix of 900 photomultipliers housed in pressure-resistant glass spheres.  These PMTs will detect the Cherenkov light emitted by the muon produced in the CC interaction of the neutrino.  The detector will be located in the Mediterranean sea (near Toulon, France) at 2475 m deep. 350mactive SubmarineElectro-optical Cable ~40km Cable ~40km Junction Box Readout cables Shore station anchor buoy Electronics container ~60m Compass,tiltmeter Optical Modules Acoustic Beacon ~100m 12 strings

J. D. Zornoza - IFIC The Optical Module Pressure-resistant sphere Material: Vitrovex 8330 Resistant to 700 bars Inner diameter: 425 mm Transm.: >95% (350 nm) Good optical matching Material: μ metal (nickel-iron alloy) Magnetic permeability: 5x x10 5 Magnetic field at ANTARES site: 44 μT Magnetic Shield Optical glue Material: Silicone rubber gel Optical matching glass sphere - PMT Fixation of the mechanical position of the different elements PMT base Modified version of PHQ5912 from iSeg Compact design Low voltage supply (±5V) Voltage stability: Three last dynodes active Internal LED Blue LED to monitor PMT transit time Pulse rise time: ~2 ns Light output: 0 to 40 pJ Stability:±5%. The main element of the Optical Module is the PMT. The sphere also houses additional elements for operation and calibration.

J. D. Zornoza - IFIC Specifications (I)   Dimensions: the PMTs for neutrino telescopes should have a large sensitive surface. However, the PMT has to fit in the glass sphere so the photocathode radius of curvature is limited to 19 cm (15'' PMT) and the total PMT height to 35 cm.   Gain: the amplitude of the single photoelectron (SPE peak) pulses has to be larger than 40 mV to avoid problems caused by electronic noise. This value corresponds to a gain of 5x10 7. In order to have a safety margin, the PMT must be able to reach a gain of 5x10 8.   Nominal voltage: the high voltage at which the gain is 5x10 7 is called nominal voltage (HV nom ) and should be lower than 2000 V so as to avoid ageing problems. The specifications explained in this section are required always at the nominal voltage.   Dark noise: due to the optical background from 40 K decays, the dark noise limit is not very stringent in the ANTARES experiment. This limit has been established at 25% the rate due to 40 K, i.e. 15 kHz for a 10'' PMT.

J. D. Zornoza - IFIC Specifications (II)   Peak to valley ratio: in order to isolate properly the single photoelectron signal from the pedestal, a minimum peak to valley ratio of 2 is required.   Transit time spread: transit time spread (TTS) is one of the most important parameters since a large value of the TTS could limit the angular resolution of the detector, which depends on time resolution. For this reason, a maximum of 3.6 ns (FWHM) has been established.   Pre-pulses and after-pulses: pre-pulses and after-pulses may induce misreconstructed events. The definitions and the maximum rates are in the table below. The time window is defined with respect to the expected time of the main pulse. The third column indicates if the pulse is correlated in time with a main pulse. TypeTime window Selection Limit Pre-pulses[-100 ns, -10 ns]<1% Delayed pulses[10 ns, 100 ns]<5% After-pulses-1*[10 ns, 100 ns]<1% After-pulses-2[100 ns, 16 μs]<10% *After-pulses-1 are correlated in time with a main pulse.

J. D. Zornoza - IFIC Candidates  Several models were studied in the pre-selection stage.  Three models were considered candidates for the ANTARES experiment (*). Photomultiplier Photocathode diameter Number of stages Dynode Structure Hamamatsu R201815”13Venetian blind Hamamatsu R ”14Box line Photonis XP18029”11Linear focused ETL 93538”12Linear focused ETL 9360KB11”12Linear focused *Hamamatsu R ”14Box line *Photonis XP1804/D210.6”10Linear focused *Hamamatsu R805513”11Box line Hamamatsu R Photonis XP1804/D2 Hamamatsu R8055

J. D. Zornoza - IFIC Experimental Setup at IFIC (I)   The PMT is inside a black box.   A μ-metal cage is used in order to shield it from the Earth magnetic field.   The laser is pulsed by means of a pulse generator and the light output is guided via an optical fiber cable inside the box.   A Lambertian diffuser is used to illuminate uniformly the photocathode.   Data acquisition is performed by CAMAC modules and the oscilloscope and sent to a PC via GPIB. Laser NIM Modules Generador de pulsos Digital Oscilloscope CAMAC Modules PC with Labview Scheme of the experimental setup used at IFIC, Valencia.

J. D. Zornoza - IFIC Experimental Setup at IFIC (II)  The laser used in the calibration is a Nd-YAG device.  It emits intense (~1μJ) and short (FWHM ~ 0.8 ns) pulses at =532 nm (green).  In few minutes, a good stability is reached (<3%).  An internal photodiode measures the emission time with very good precision (~50 ps)

J. D. Zornoza - IFIC SPE spectrum  The single photoelectron (SPE) charge spectrum is fitted to a function which takes into account the different contributing terms: G  Gaussian distribution P  Poissonian distribution F  Valley distribution (exp + G) μ n = n·μ 1 and  n 2 = n· 1 2 ω  fraction of wrongly amplified electrons. β  fraction of the valley events moving to the exponential α  slope of the exponential notation:

J. D. Zornoza - IFIC Gain The largest gain and the fastest increase with voltage are attained for the R model (it has 14 dynodes). The model with higher nominal voltage is the R8055, since it is optimized for TTS, not for gain. The three models reach a gain of 10 8.Model HV nom (V) R XP1804/D21680 R Nominal voltage (Gain=5x10 7 )

J. D. Zornoza - IFIC Amplitude (SPE peak) The behaviour for amplitude (SPE peak) is similar to the case of gain. The highest amplitude is reached by the R The value of the R8055 model at the nominal voltage is slightly low.Model Amplitude (mV) R XP1804/D260 R HV nom

J. D. Zornoza - IFIC Peak to Valley The peak to valley ratio of the R and the XP1804/D2 at nominal voltage is around 2.7. The behaviour of the R8055 is very good: high P/V and quite stable around the HV nom.ModelP/VR XP1804/D22.7 R Peak to HV nom

J. D. Zornoza - IFIC Energy Resolution The behaviour of the R7081 at low voltages is unstable, but around the HV nom is flat (~30%). The XP1804/D2 is also almost flat around the same value. The R8055 curve is a bit worse since it grows with voltage up to 35%.Model Energy Resolution R % XP1804/D231% R805534% Energy HV nom *The energy resolution is defined as the ratio of the charge SPE peak width over its position.

J. D. Zornoza - IFIC Transit Time Spread The level of illumination is around 0.3. The threshold of discrimination is ½ photoelectron. Example of Time Distribution The time distribution measured by the TDC is fitted to the product of a Gaussian and an exponential: A calibrated PMT (TTS=0.230.01 ns) is used to measure the contribution not due to the PMT

J. D. Zornoza - IFIC TTS The slope of the decrease of TTS with voltage is quite similar for the three models. The better value at HV nom is obtained by the XP1804/D2. All of them are within the specifications.Model TTS (ns) R XP1804/D22.0 R HV nom

J. D. Zornoza - IFIC Dark Current Noise The lower dark noise rate of the R can be partially attributed to its smaller surface. When normalizing to the same area, R remains the better, but the other models are within the specifications.Model DC (Hz) R XP1804/D24300 R Dark Current HV pe

J. D. Zornoza - IFIC After-pulses RatePre-pulses [-100 ns, -10 ns] Delayed Pulses [10 ns, 100 ns] After-pulses-1 After-pulses-2 [100 ns, 16 μs] R <0.01%3.6%1.0%3.8% XP1804/D2<0.01%4.7%3.2%18% R %5.0%2.4%19% Pre-pulse rate is OK for the R and the XP1804, but too high for R8055. All PMTs exhibit acceptable delayed pulse rates. Only R have good values of after-pulses 1 and 2.

J. D. Zornoza - IFIC Summary  In general, the three models are within the specifications.  The nominal amplitude of the R8055 is slightly low.  The XP1804/D2 and the R8055 show a high rate of after-pulses.  Finally, the R was considered the best choice.

J. D. Zornoza - IFIC Experimental Setup at DAPNIA  After the choice of the model (R ), the full sample of ANTARES PMTs (912) has been tested by means of an experimental setup capable to provide a fast way to characterize them.  This characterization was carried out in the ‘recette’ test bench, which consists of a light tight plastic cylinder 1.5 m long and 0.46 m in diameter.  The PMT is illuminated by a blue LED guided by an optical fiber.  A Lambertian diffuser is used for uniform illumination of the whole photocathode. All final test have been performed with an optimsed PMT base. This explains the difference between the HV nom and the TTS obtained during the final tests and the results discussed previously.

J. D. Zornoza - IFIC Gain The mean of the distribution is ~1800 V with an RMS around 50 V. In all cases, the nominal voltage is below 2000 V, as required. Moreover, all the tubes reach a gain of Evolution of HVnom with the batch number

J. D. Zornoza - IFIC Amplitude – Peak to Valley There are 20 PMTs with a low P/V value, but the mean P/V is around 2.8, i.e. within the specifications. There is a correlation with the batch number, which indicates a gradual improvement in this parameter. The mean amplitude is larger than 40 mV, which is within the recommended value. The amplitude of all the PMTs is larger than 35 mV.

J. D. Zornoza - IFIC Pulse Shape  Mean rise time is slightly higher than 4 ns and fall time is around 12 ns.  Regarding time width, the value for all the PMTs is lower than 9 ns, i.e. acceptable according to the specifications. Rise time (ns) Time width (ns) Fall time (ns)

J. D. Zornoza - IFIC TTS The value of TTS has been improved by a modification in the PMT base design. The distribution of the values of the transit time spread (FWHM) has a mean value of 2.8 ns and RMS of 0.15 ns. There is no tube with a TTS value larger than 3.6 ns.

J. D. Zornoza - IFIC Dark Current Noise Almost all the PMTs have a dark current rate lower than 9000 Hz, i.e. within the specifications for a tube whose photocathode surface is 450 cm 2. Only two PMTs are above this limit. Moreover, 85% of the tubes are below 3000 Hz. Threshold=1/4 pe

J. D. Zornoza - IFIC Pre-pulses and Delayed Pulses The pre-pulse rate is very low (<0.1% for all the PMTs). Results for delayed pulses are also OK. Only two units exhibit a rate larger than 5%.

J. D. Zornoza - IFIC After-pulses The distribution of the after-pulses-1 shows two types of PMTs. Those of the first batch are above 2% and the rate for the rest is around 1.5% The after-pulse-2 rate is within the limits, since all PMTs show a rate below 6%.

J. D. Zornoza - IFIC Ageing (I)  Long term stability has to be checked.  Three PMTs were placed in a black box and excited by three independent LEDs.  LEDs reproduced the optical background environment ( 40 K and bioluminiscence), increased by a factor two to speed up the process: –A continuous rate of 100 kHz –Bursts of 1 MHz lasting 0.1 second every second.

J. D. Zornoza - IFIC Ageing (II) Time (days) Gain (x10 8 ) Evolution of gain at HV constant  Along the first 100 days, the three PMTs showed an increase of 50-70% in gain, and then stabilized (running-in phase).  P/V, energy resolution, TTS and dark noise remained stable.  After-pulse-2 rate showed an increase (30%) most likely due to the accumulation of ionized gas atoms.

J. D. Zornoza - IFIC Conclusions  The PMTs are a key component of the ANTARES neutrino telescope.  A list of specifications has been done in order to choose the optimum PMT.  After a pre-selection stage, three models were considered as candidates: R , XP1804/D2 and R8055.  Taking into account these results, the R was considered the best option.  A large sample of 912 units of the selected model has been tested and the results are satisfactory.