Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Chapter 35 Humidity and Bland Aerosol Therapy.

Slides:



Advertisements
Similar presentations
Heating, Ventilation, and Air-Conditioning (HVAC) Systems
Advertisements

Oxygen Therapy.
1 Oxygen Gas Administration م. م زيد وحيد عاجل. 2 Oxygen Therapy General Goals/objectives –Correcting Hypoxemia By raising Alveolar & Blood levels of.
Oxygenation By Diana Blum MSN NURS Oxygen is clear odorless gas 3 components for respiration Breathing Gas exchange Transportation Structures Upper.
Rhonda Contant, BScH, RRT
Basic Refrigeration Cycle
RT Physics Week 4 QUIZ Review of Pressure Conversions
Refrigeration Flow Control
Heating Control Devices
High Flow Therapy (HFT)
Gas – Vapor Mixtures & Air – Conditioning
Resistance. What is Resistance? Resistance is a measurement of the frictional forces that must be overcome during breathing. It can also be described.
High Flow Therapy (HFT)
Initiation of Mechanical Ventilation
Steam Power Plant.
Chapter 39 Lung Expansion Therapy
HVACR416 - Design Humidification. Relative Humidity 1.Air in the home is artificially dried out when it is heated. 2.Because warm air expands, this expansion.
It is the amount of water vapour present in the atmosphere and is subdivided into two types: Absolute humidity: - The total mass of water vapour present.
Dr. Mohamed Sayed Shorbagy Lecturer of Anesthesia and Intensive care
Aerosol Therapy and Nebulizers
Lesson 7 Steam Power Plant.
Review Lung Volumes Tidal Volume (V t )  volume moved during either an inspiratory or expiratory phase of each breath (L)
Advanced Issues in Humidification Advanced Issues in Humidification Presented by: Ruben Restrepo MD, RRT, FAARC Professor, Department of Respiratory Care.
1 Elsevier items and derived items © 2010 by Saunders, an imprint of Elsevier Inc. Chapter 19 Mechanical Ventilation of the Neonate and Pediatric Patient.
Humidity & Aerosol.
CHAPTER 6 Moving Heat: Heating and Air Conditioning Principles
Humidity Therapy and Humidifiers
Copyright © 2009 Wolters Kluwer Health | Lippincott Williams & Wilkins Chapter 21 Oxygenation.
Water in the Atmosphere Section 1 Changing Forms of Water Water in the atmosphere exists in three states, or phases. One phase is known as a gas called.
Without reference, identify principles about volume/pressure and high frequency ventilators with at least 70 percent accuracy.
Know your Os? How much Oxygen is the patient on? How much does the patient need? How’s this mask work? Is this thing hooked up right?
Oxygenation And Ventilation
Lesson 8 SECOND LAW OF THERMODYNAMICS
+ Atmospheric Moisture Chapter 4. + Learning Targets LT #1: I can describe the movement of water through the hydrologic cycle. LT #2: I can summarize.
Final Considerations in Ventilator Setup Chapter 8.
Heating Systems.
1 © 2013 Cengage Learning. All Rights Reserved. May not be copied, scanned, or duplicated, in whole or in part, except for use as permitted in a license.
Mosby items and derived items © 2008, 2002 by Mosby, Inc., an affiliate of Elsevier Inc. Chapter 3 Administration of Aerosolized Agents.
 Spray drying - formation of droplets from the bulk liquid – moisture removal  liquid droplets - sprayed –drying chamber  the low-humidity hot gas.
Copyright © 2009 Wolters Kluwer Health | Lippincott Williams & Wilkins Chapter 21 Oxygenation.
Copyright © 2011, 2007 by Mosby, Inc., an affiliate of Elsevier Inc.
Aerosol Therapy and Nebulizers
Chapter 14 Respiratory Procedures. Copyright © 2007 Thomson Delmar Learning. ALL RIGHTS RESERVED.2 Patients at Risk for Poor Oxygenation Hypoxemia –Insufficient.
Respiratory care.
EARTH SCIENCE Prentice Hall EARTH SCIENCE Tarbuck Lutgens 
Chapter 35 Humidity and Bland Aerosol Therapy
Prepared by Dr. Irene Roco
Chapter 14 Respiratory Procedures. Copyright © 2007 Thomson Delmar Learning. ALL RIGHTS RESERVED.2 Patients at Risk for Poor Oxygenation Hypoxemia –Insufficient.
Inhalation Devices Heba Abd El-fattah Sabry Pharm D.
EARTH SCIENCE Prentice Hall EARTH SCIENCE Tarbuck Lutgens 
Student will be able to explain the various methods of oxygen administration and the role of the NA. Student will be able to list the safety precautions.
1 Elsevier items and derived items © 2010 by Saunders, an imprint of Elsevier Inc. Chapter 20 Neonatal and Pediatric High-Frequency Ventilation.
Water in the Atmosphere Chapter 18, Section 1. Water in the Atmosphere  Precipitation – any form of water that falls from a cloud  When it comes to.
Automotive Heating and Air Conditioning CHAPTER Automotive Heating and Air Conditioning, 7e James D. Halderman | Tom Birch SEVENTH EDITION Copyright ©
Wet Packs: Strategies for Prevention and Resolution
Mechanical Ventilator
PRESSURE CONTROL VENTILATION
A Simple Circuit to Deliver Bubbling CPAP Charanjit Kaur, Akatoli Sema, Rajbir S. Beri and Jacob M. Puliyel Department of Pediatrics, St Stephens Hospital,
Respiratory Therapy Equipment Adnan Mohemmed S6 AE.
Mechanical Ventilation Circuit Errors For RET 2264C-12 Dr. J.B. Elsberry Prof. J. M. Newberry.
Promoting Oxygenation
“Respiratory equipments”
Psychrometric Processes
Respiratory Disorders
By: JAGDEEP SANGWAN Refrigeration Basics 101.
Aerosol Drug Therapy Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc.
Review of Humidity-Aerosol Therapy
Presentation transcript:

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Chapter 35 Humidity and Bland Aerosol Therapy

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 2 Learning Objectives  Describe how airway heat and moisture exchange normally occur.  State the effect that dry gases have on the respiratory tract.  State when to humidify and warm inspired gas.  Describe how various types of humidifiers work.  Describe how to enhance humidifier performance.

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 3 Learning Objectives (cont.)  State how to select and safely use humidifier heating and feed systems.  Identify the indications, contraindications, and hazards that pertain to humidification during mechanical ventilation.  Describe how to monitor patients receiving humidity therapy.  Describe how to identify and resolve common problems with humidification systems.

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 4 Learning Objectives (cont.)  State when to apply bland aerosol therapy.  Describe how large-volume aerosol generators work.  Identify the delivery systems used for bland aerosol therapy.  Describe how to identify and resolve common problems with aerosol delivery systems.

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 5 Learning Objectives (cont.)  Describe how to perform sputum induction.  State how to select the appropriate therapy to condition a patient’s inspired gas.

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 6 Humidity Therapy  Physiologic control of heat & moisture exchange  Heat & moisture exchange is primary role of upper airway, mainly nose Nose heats & humidifies gas on inspiration & cools & reclaims water from gas that is exhaled  BTPS conditions Body temperature at 37º C; barometric pressure; saturated with water vapor [100% relative humidity at 37º C] Achieved as inspired gas moves into lungs Normally ~5 cm below carina is isothermic saturation boundary (ISB)

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Humidity Therapy (cont.)  Physiologic control of heat & moisture exchange (cont.)  Isothermic saturation boundary Above ISB, temperature & relative humidity decrease during inspiration & increase during exhalation Below ISB, temperature & relative humidity remain constant ISB shifts distally when  person breathes cold, dry air  airway is bypassed (breathing through an artificial airway)  minute ventilation is higher than normal Shifts of ISB can compromise body’s normal heat & exchange mechanisms  humidity therapy may be indicated 7

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Humidity Therapy (cont.) 8

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Humidity Therapy (cont.)  Relative humidity  Ratio between amount of water in given volume of gas & maximum amount it is capable of holding at that temperature  Expressed as percentage & is obtained with hygrometer  Relative humidity = absolute humidity capacity x 100  Absolute humidity  Amount of water in given volume of gas; its measurement is expressed in mg/L 9

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Humidity Therapy (cont.)  Body Humidity  Relative humidity at body temperature & is expressed as percentage  Capacity of water at body temperature is 44mg/L  Body humidity = absolute humidity/ 44mg/L x 100  Humidity deficit  Inspired air that is not fully saturated at body temperature  Deficit is corrected by body’s own humidification system  Humidity deficit = 44 mg/L – absolute humidity 10

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 11 What is the term for inspired air that is not fully saturated at body temperature? A.relative humidity B.absolute humidity C.humidity deficit D.body humidity

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 12 Humidity Therapy (cont.)  Indications for humidification & warming of inspired gases  Administration of dry medical gases at flows greater than 4 L/min.  Overcoming humidity deficit created when upper airway is bypassed, such as after endotracheal intubation  Managing hypothermia  Treating bronchospasm caused by cold air

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Humidity Therapy (cont.) 13

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 14 Equipment  Humidifier- device that adds molecular water to gas, occurring by evaporation of water from a surface

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Equipment (cont.)  Physical principles governing humidifier function:  Temperature – the higher the temperature of gas, the more water it can hold  Surface area – affects rate of evaporation  Time of contact – evaporation increases as contact time increases  Thermal mass - the greater the amount of water in humidifier, the greater the thermal mass & capacity to hold & transfer heat to therapeutic gas 15

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Equipment (cont.) 16

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 17 Types of Active Humidifiers  Bubble humidifiers  Breaks underwater gas stream into small bubbles  Use of foam or mesh diffuser produces smaller bubbles than open lumen, allowing greater surface area for gas/water interaction  Usually used unheated with oxygen delivery systems to raise water vapor content of gas to ambient levels  Includes simple pressure relief valve, or pop off to warn of flow-path obstruction & to prevent bottle from bursting  Can produce aerosols at high flow rates Poses risk of infections

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Bubble Humidifiers 18

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 19 Types of Humidifiers (cont.)  Passover  directs gas over water surface  Three types 1. Simple reservoir type 2. Wick type  Absorbent material increases surface area for dry air to interface with heated water 3. Membrane type  Separates water from gas stream by means of hydrophobic membrane  Advantages over bubble humidifier: Maintains saturation at high flow rates Add little or no flow resistance to spontaneous breathing circuits Do not generate any aerosols that can spread infection

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Types of Humidifiers (cont.) 20

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 21 Types of Humidifiers (cont.)  Heat-moisture exchangers (HMEs)  Often passive humidifier that has been described as “artificial nose”  Does not add heat or water to system  Captures exhaled heat & moisture, which is then applied to subsequent inhalation  Types of HMEs Simple condenser humidifiers Hygroscopic condenser humidifiers Hydrophobic condenser humidifiers  Adds mL of dead space

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Types of Humidifiers (cont.) 22

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Types of Humidifiers (cont.)  Active HMEs  Humid-Heat Absorbs expired heat & moisture & releases it into inspired gas Consists of supply unit with microprocessor, water pump, & humidification device  HME Booster Designed for patients with minute volumes of 4-20L Not appropriate for pediatric patients & infants Consists of T-piece containing electrically heated element 23

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 24 Which humidifier can deliver gas at 100% body humidity? A.wick humidifier B.passover humidifier C.bubble humidifier D.HME

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 25 Heating Systems  Heat improves water output of bubble & passover humidifiers  Used primarily for patients with bypassed upper airways & those receiving mechanical ventilation  Heating inhaled gas can expose patient to certain risks (e.g., airway burns)

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Heating Systems (cont.)  Types of heating elements that require energy source:  Hot plate element at base of humidifier  Wraparound type  Yolk, or collar element  Immersion-type heater  Heated wire 26

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 27 Reservoir & Feed Systems  Heated humidifiers can evaporate more than 1 L H 2 O per day  To avoid constant refilling, devices use:  Large water reservoir  Gravity feed system

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Reservoir & Feed Systems (cont.) ●Manual Systems ●Simple large reservoir systems are manually opened & refilled with sterile or distilled water; cross-contamination can occur ●Small inlet can be attached to gravity-fed intravenous bag & line allows refilling without interruption ●Automatic Systems ●Avoids need for constant checking & manual refilling ●Flotation valve controls can be used to maintain humidifier reservoir fluid volume 28

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Reservoir & Feed Systems (cont.) 29

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Reservoir & Feed Systems (cont.) 30

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 31 Setting Humidification Levels ●At least 30 mg/L of humidity is recommended for intubated patients ●Humidifiers should provide optimal levels of humidity in inspired gas ●Some experts recommend heating inhaled gas to maintain airway temperatures near ºC

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 32 Problem Solving & Troubleshooting ●Condensation  Poses risks to patient & caregivers  Can waste a lot of water  Can occlude gas flow through circuit  Can be aspirated  Problem can be minimized with use of water traps & heated circuits, by positioning circuits so it drains condensate away from patient, & checking humidifier & nebulizer often

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Problem Solving & Trouble Shooting (cont.) 33

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 34 Problem Solving & Troubleshooting (cont.) ●Cross-contamination  Water in circuit can be source of bacterial colonization  Minimizing condensation is helpful to reduce risk of colonization  Wick-or membrane type passover humidifiers prevent formation of bacteria-carrying aerosols  Frequently changing circuit is not needed to reduce chance of nosocomial infection

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Problem Solving & Troubleshooting (cont.)  Proper conditioning of Inspired Gas  RT’s role Ensure proper conditioning of inspired gas received by patients by:  Regularly measuring patients’ inspired FiO 2 levels  Providing ventilatory care & monitoring selected pressures, volumes, & flows  Using hygrometer-thermometer system 35

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 36 Common problems with humidification systems include all of the following, except: A.dealing with condensation B.avoiding cross contamination C.ensuring proper conditioning of inspired gas D.hypothermic interpretation

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 37 Bland Aerosol Therapy  Bland aerosol consists of liquid particles suspended in gas (oxygen or air)  Variety of liquids may be used  Sterile water  Sterile saline hypotonic isotonic hypertonic

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 38 Large-Volume Jet Nebulizers  Most common device used for bland aerosol therapy  Pneumatically powered & connected directly to flowmeter & compressed gas source  Unheated large-volume nebulizers can produce 26 to 35 mg H 2 O/L  Heated nebulizers can produce 35 to 55 mg H 2 O/L  Mainly due to increased vapor capacity  Variable air-entrainment port allows air mixing to increase flow rates & to alter FiO 2 levels

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 39 Large-Volume Jet Nebulizers (cont.)  Mechanism  Liquid particles are generated by passing gas at high velocity through small jet orifice  Low pressure at jet draws fluid from reservoir up siphon tube  Water is then shattered into liquid particles  Smaller particles leave nebulizer through outlet port in gas stream

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Large-Volume Jet Nebulizer 40

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 41 Ultrasonic Nebulizers ●Electrically powered device that uses piezoelectric crystal to generate aerosol ●Crystal transducer converts radio waves into high-frequency mechanical vibrations that produce aerosol

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Ultrasonic Nebulizers ●Particle size is inversely proportional to signal frequency ●Signal amplitude directly affects volume of aerosol output ●Flow & amplitude settings interact to determine aerosol density (mg/L) & total water output (mL/min) 42

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Ultrasonic Nebulizer 43

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 44 Airway Appliances  Types  Aerosol mask  Face tent  T-tube  Tracheostomy mask  All used with large-bore tubing to minimize flow resistance & prevent occlusion by condensate

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Airway Appliances 45

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 46 Enclosures (Mist Tents & Hoods)  Used to deliver aerosol therapy to infants & children  Poses problems  Heat retention Handled differently by each manufacturer Maxicool use high fresh-gas flows Others may use separate cooling device  CO 2 buildup in tents High flows of fresh gas circulating continually through tent help “wash out” CO 2 & reduce heat buildup

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 47 Problem Solving & Troubleshooting  Problems with bland aerosol therapy  Cross-contamination and infection Adhere to infection control guidelines  Environmental exposure Follow Centers for Disease Control & Prevention standards & airborne precautions  Inadequate mist production Check electrical power supply, carrier gas is actually flowing through device, amplitude control, & couplant chamber

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Problem Solving & Troubleshooting (cont.)  Problems with bland aerosol therapy (cont.)  Overhydration Prevention by careful patient selection & monitoring is key  Bronchospasm Treatment must be stopped immediately & provide oxygen  Noise 48

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 49 The main usage for bland aerosol therapy include all of the following, except: A.treat upper airway edema B.overcome heat and humidity deficits C.help obtain sputum specimens D.provide adequate mist production

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Sputum Induction  Cost-effective, safe method for diagnosing tuberculosis, Pneumocystis carinii (aka P. jiroveci), pneumonia, & lung cancer  Involves short-term application of high- density hypertonic saline (3% to 10%) aerosols to airway  Aids in mucociliary clearance  High-density aerosols are most easily generated by using ultrasonic nebulization 50

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. Selecting the Appropriate Therapy 51

Copyright © 2013, 2009, 2003, 1999, 1995, 1990, 1982, 1977, 1973, 1969 by Mosby, an imprint of Elsevier Inc. 52 The key considerations of selecting the appropriate therapy for conditioning a patient’s inspired gas include all of the following, except: A.gas flow B.presence or absence of an artificial tracheal airway C.character of pulmonary secretions D.medications used