Hydraulic Jump.

Slides:



Advertisements
Similar presentations
Chapter 4: Non uniform flow in open channels
Advertisements

Flood Profile Modeling with Split Flows and Weirs
Change of the flow state
Spillways Abdüsselam ALTUNKAYNAK, PhD Associate Professor,
Introduction to Long-Throated Flumes and Broad-Crested Weirs
Chapter 13: Momentum Principles in Open-Channel
Total & Specific Energy
CHAPTER FOUR Stream flow measurement
Example: Uniform Flow at Known Q and y
Weirs Generally, any flow obstruction that causes water to rise to flow over it, but used exclusively for intentional obstructions Uses include flow measurement.
Flow Over Notches and Weirs
Experiment (6) Flow over weirs
HYDRAULIC 1 CVE 303.
Open Channel Flow Part 2 (cont)
CHAPTER 6: Water Flow in Open Channels
Control Structures.
Gates. Gates Gates are used to control the discharge and also to stop the flow if required. Gates are used to control the discharge and also to stop the.
Broad-crested Weir.
Pertemuan Open Channel 2. Bina Nusantara VARIED FLOW IN OPEN CHANNELS.
Hydraulic Jump as an application of Momentum Equation
MECH 221 FLUID MECHANICS (Fall 06/07) Chapter 10: OPEN CHANNEL FLOWS
If there is no change in friction or slope as we move down stream
The Centrifugal Pump.
Hydrology and Water Resources RG744 Institute of Space Technology December 11, 2013.
GRADUALLY VARIED FLOW CVE 341 – Water Resources
Water Flow in Open Channels
Open Channel Flow.
Chapter 7 continued Open Channel Flow
Chapter 20 Open-channel flow. When one has a flow of water to convey, either to provide some at a place where there is none, or to drain where there is.
PRINCIPLES OF OPEN CHANNEL FLOW
MEASURING FLUMES By CH. VENKATARAMAIAH.
Engineering Low-Head Dams for Function and Safety Fritz R. Fiedler Department of Civil Engineering University of Idaho.
Unit: IV-Fluid Dynamic
Hydraulics for Hydrographers Basic Hydrodynamics
The Stage-Discharge Rating D. Phil Turnipseed, P.E. Hydrologist USGS-FERC Streamgaging Seminar Washington, D.C. June 6-7, 2006.
ERT 349 SOIL AND WATER ENGINEERING
Overview of Open Channel Flow Definition: Any flow with a free surface at atmospheric pressure Driven entirely by gravity Cross-section can vary with location.
CTC 261 Culvert Basics.
Chapter 2: Total Hydrostatic Force on Surfaces
Basic Hydraulics: Channels Analysis and design – I
Basic Hydraulics: Open Channel Flow – I
OC FLOW: ENERGY CONCEPTS, CHANNEL ANALYSIS
Basic Hydrology & Hydraulics: DES 601 Module 16 Open Channel Flow - II.
Statika Fluida Section 3. Fluid Dynamics Objectives Introduce concepts necessary to analyse fluids in motion Identify differences between Steady/unsteady.
 It is the type of V. F. in which the width of throat is decreased to such an extent that the depth of water in throat is equal to critical depth. 
Basic Hydraulics: Rating curve. Definition & terminology Rating curve, also known as stage–discharge curve, is a graph showing the relation between the.
Hydrology and Water Resources RG744 Institute of Space Technology November 13, 2015.
Energy Equation The expanded Bernoulli's equation
HYDROLOGY & WATER RESOURCES ENGINEERING TYPES OF SPILLWAYS
Basic Hydraulics: Open Channel Flow – II
SUB:-FLUID MECHANICS TOPIC:-FLOW MEASUREMENT DEVICES SUBMITTED TO: KULDEEP SIR Government engineering college, valsad.
Government Engineering College,Bhavnagar
Open Channel Hydraulic
CE 3372 Water Systems Design
EXAMPLE Water flows uniformly in a 2m wide rectangular channel at a depth of 45cm. The channel slope is and n= Find the flow rate in cumecs.
FLUID MECHANICS.
Expression Session Summarise “stream discharge” and “river load” using diagrams to assist your answer.
Flow measuring device mouthpiece.
DISCHARGE OVER A BROAD-CRESTED WEIR
Measurement of discharge
Basic Hydrology & Hydraulics: DES 601
ERT 349 SOIL AND WATER ENGINEERING
Chapter 4. Gradually-varied Flow
CE 356 Elements of Hydraulic Engineering
Hydraulic Structures HYDRAULIC STRUCTURES.
HEC-RAS US Army Corps of Engineers Hydrologic Engineering Center
Subject Name: FLUID MECHANICS
BAE 6333 – Fluvial Hydraulics
Flow Measurements.
Fundamentals of TRANSPORT MECHANISMs
Presentation transcript:

Hydraulic Jump

Most important phenomena in Hydraulics Occurs when supercritical flow has its velocity reduced to subcritical The result is marked by a discontinuity of surface characterised by a steep upward slope of the water surface broken throughout by violent turbulences known as Hydraulic Jump.

This hydraulic jump is said to be the dissipater of the surplus energy of water. After the hydraulic jump the water flows with a greater depth and less velocity. The use of this phenomenon is sometimes made in hydraulic structures such as spillway of a dam to minimize the erosive power of supercritical flow

Relationships for the calculation of depth of flow before and after the jump are needed. For channels of gradual slope (less than 0.05) the gravity component of the weight is very small and can be neglected without introducing significant error. Frictional forces can also be neglected because of shorter length of the channel and therefore the only significant forces are the hydrostatic forces.

Applying momentum equation between section 1 and 2 of the figure and using the relation for end forces, Where hc is the depth to the centroid of the end area.

Rearranging the previous equation This states that the momentum plus the pressure force on the cross sectional area is constant, or dividing by γ and observing that V=Q/A

This can be applied to any shape of cross section.

For a rectangular cross section, and the discharge Q in terms of discharge per unit width can be given by Q=bq. So

A curve of different values of fm for different values of y is plotted. The loss of energy due to the jump will not affect the force so fm before and after the jump is the same So the vertical line on the fm curve shows two conjugate depths y1 and y2.

These depths represent possible combinations of depth that could occur before and after the jump. So in the figure, the line for initial water level y1 intersects the fm curve at ‘a’ giving a value of fm which must be the same after the jump. The vertical line ‘ab’ then fixes the value of y2

This is then transmitted to the specific energy diagram to determine the value ‘cd’ of V22/2g. The value of V12/2g is the vertical distance ef. For a rectangular channel, it can be shown that the minimum value of fm occurs at the same depth as the minimum value of E. Differentiating fm with respect to ‘y’ and equating to zero

The above expression is same as the relation for critical depth

So for a given ‘q’ the minimum value of fm occurs at the same depth as does the minimum value of E. When the rate of flow and depth before or after the jump are given, the equation for fm becomes a cubic equaiton when solving for other depth This can be reduced to a quadratic equation by observing that

so

Flow measuring structures

Weirs are overflow structures build across channels to measure the volumetric rate of flow of water. It is an obstruction that causes the liquid to rise behind the weir and flow over it. The crest of the measuring weir is normally perpendicular to the direction of flow.

Constructed from metal, masonry or concrete etc. Weirs are identified by the shape of their opening or notch The edge of the opening can be sharp or it can be broad, consequently, the weirs will weather be sharp crested or broad crested.

Sharp crested weir A weir with a sharp upstream corner is known as sharp crested weir The weir plate thickness at the crest edges should be from 0.03 to 0.08 inches.

A weir having a horizontal or nearly horizontal crest sufficiently long in the direction of flow These support the falling jet over their crest in the longitudinal direction.

Discharge over a rectangular weir can be calculated by using the formula Cd is the coefficient of discharge and L is the length of crest.

Consider a broad-crusted wire as shown above. Let A and B are u/s and d/s ends of the weir. Let L is length and Cd is coefficient of discharge. H is the head at u/s and h is at d/s of weir. Let V is velocity of water at B now applying energy eq. at A&B (considering the approach velocity to be zero)

The discharge over weir at B is given by Q=Cd*Area of Flow*Velocity Substituting the value of V

(1) If Cd, L and g are constant, then discharge will be maximum when (Hh2 – h3) is maximum. Differentiating with respect to h and equating to zero

Substituting the values in (1)

Triangular or V-notch weir For relatively small flows, the rectangular weir could be quite narrow. In this case the value of H over the weir will be so small that the nappe will not stay clear rather it will cling to the plate Thus the use of triangular weir comes into practice as it function for relatively low flows

The fundamental equation for discharge over a triangular v-notch weir is given by

Velocity of approach Sometimes a weir is provided in a stream or a river (in storage reservoir vel. of app is taken as zero) to measure the flow of water. In such a case, the water approaching the u/s of weir has got some velocity of approach and is assumed to be uniform over the whole weir.

In deriving formula for discharge over broad crested weir, we have ignored velocity of approach but in actual practice velocity of approach of water is sure to affect the discharge over the weir. Let a = x- sectional area of channel on u/s side of weir

Additional height / head due to velocity of approach

Thus if velocity of approach is also considered then total height above the weir is Ht = H + Ha H = Ht – Ha Discharge over the weir will then be given by

In every hydraulic structure (i. e In every hydraulic structure (i. e. Bridge, regulator etc) which is constructed across an open channel, a few opening are left to allow the water to pass. If the total width of all these openings is practically the same as that of the channel, such a structure is called full width or unflumed structure. But generally the total width of such a structure is kept much less than the width of the channel to keep economy in its construction and to increase its utility. Such a structure whose width is less than the width of channel is called flumed structure.

A flumed structure used for the measurement of the quantity of water is called venturiflume. The difference between venturimeter and venturiflume is that in venturimeter the flow is under pressure whereas in a venturiflume the flow is under gravity and pressure is atmospheric. Following two types of venturiflume are important from subject point of view:-

Non-modular venturiflume A non-modular venturiflume consists of Convergent cone It is short part of the channel which converges from b1 to b2. It is also called inlet of the venturiflume. Throat It is the small portion of the channel in which width b2 is kept constant Divergent cone It is the small portion of the channel which diverges from width b2 to again width b1.

Venturi meter

Venturi Flume

The liquid while flowing through venturiflume is accelerated between section 1-1 and 2-2 so the velocity at 2-2 is more than that at 1- 1 thus depth at section 2-2 decreases energy eq. between sec 1-1 &2-2 (as z1=z2)

Since discharge at section 1-1&2-2is continuous therefore A1 V1 = A2 V2 (Eq.of cont.)

Substituting this value in eq.

Let h = difference of head at 1-1&2-2

Discharge through venturiflume is Q = coeff of venturiflume xa2 v2 Q = Ca2v2 Value of C depends on smoothness of surface of bed/sides and round ness of cornors of V.F= It ranges 0.95 to 1.0

Modular Venturi flume It is the type of V. F. in which the width of throat is decreased to such an extent that the depth of water in throat is equal to critical depth. The velocity of flow through the throat corresponding to critical depth is also critical.