ElectroMagnetic Compatibility in Cable Tray Systems

Slides:



Advertisements
Similar presentations
attract circuit When two objects are pulled together.
Advertisements

attract When two objects are pulled together circuit.
International Telecommunication Union Technical Session on Home Networks Geneva, 29/04/2011 ITU-T Study Group 5 Protection against Lightning Phil Day Australia.
Standards for the protection of radio installations
Interface and cabling characterization for SKA Paul van der Merwe Prof. HC Reader Stellenbosch University.
Transmission Media T.Najah Al-Subaie Kingdom of Saudi Arabia
Electricity By Lauryn Jackson. How lightning is formed. Lighting is formed by: a build up of charge Separating of the charges Then finally, the charges.
+ Straight-Through Cable Construction Lab 4. + Data Transmission In data transmission system, the transmission medium is the physical path between transmitter.
1 Internal loop Slot Strap ESD simulator Cable to the Oscilloscope Point A Point B CST STUDIO SUITE™ 2006 EMC - Application and Feature Tutorial.
Earth Ground Resistance The Basics
Telecom Cabling Grounding and bonding.
TRENDS IN ELECTRIC FENCING
Electrical Safety and Grounding Essentials Copyright © Texas Education Agency, All rights reserved.
Designing a EMC Compatible Electronic Meter using AD7755 a.
Technician License Course Chapter 9 Lesson Module 20: Electrical Safety.
Guide to Network Cabling Fundamentals
Lecture 1: Safety and Protection. 1. A robot may not injure a human being or, through inaction, allow a human being to come to harm. 2. A robot must obey.
1 ME 234/2 HV noise investigation N.Bondar CMU. 12/18/02.
IHP Im Technologiepark Frankfurt (Oder) Germany IHP Im Technologiepark Frankfurt (Oder) Germany ©
HARMONY XB5R SENSING RANGE & ROBUSTNESS. Schneider Electric 2 - Control – L.Bernier – August 2011 Typical distance transmitter / receiver 100m in free.
Bonding, Grounding and the NEC  Presented by The National Association of Certified Home Inspectors
HL-LHC Standards and Best Practices Workshop (11-13 June 2014)
Experimental Area Meeting V. Bobillier1 Good connection to earth (in many points) of every metallic parts to be installed in the cavern is very.
Reproduction interdite © ALMA EUROPEAN CONSORTIUM Reproduction forbidden Design, Manufacture, Transport and Integration in Chile of ALMA Antennas Page.
Climatic, Mechanical resistance and EMC requirements Russian justification Accident Emergency Call System (AECS) 4 th meeting Paris April 28 th - 30 th.
A basic property of the tiny particles that make up matter; it can be positive or negative: Some particles of matter have an electric charge. Electric.
Operational and Technical Requirements Rob Connatser Chief Instrument Project Engineer November 2014.
Communication channels and transmission media
PSerc Lightning Protection: A Stroke of Luck? Theory and Application: Customer Side Low Voltage Systems Ward Jewell Wichita State University APPA 2005.
ECOM 4314 Data Communications Fall September, 2010.
Grounding, bonding, and ground fault currents
Integrated Grounding, Equipotential Bonding and Lightning Protection in Smart Grids and Smart Buildings – A Multi-Faced Approach Ladies and gentlemen,
Section 3.1: Wires, Cables, and Connectors Scott Glogovsky and Jonathon Sturm Scott Glogovsky and Jonathon Sturm.
Copper Media Describe the specifications and performances of different types of cable. Describe coaxial cable and its advantages and disadvantages over.
Ground loops Why grounding is so important ?DefinitionGround loops :(Introduction)where ground loops affect ?Ground loops are created by :Solutions.
Transmission Lines No. 1  Seattle Pacific University Transmission Lines Kevin Bolding Electrical Engineering Seattle Pacific University.
A division of Martek Power Group Ground Bond Testing for Production and Maintenance.
07 - Winter 2005 ECE ECE 766 Computer Interfacing and Protocols 1 Grounding Grounds: –Common reference for the circuit –Safety What is the potential problem.
Etienne CARLIER, LBDS Audit, 28/01/2008 LBDS Environmental Aspects EMC, radiation, UPS… Etienne CARLIER AB/BT/EC.
Prof R T KennedyEMC & COMPLIANCE ENGINEERING 1 EET 422 EMC & COMPLIANCE ENGINEERING.
TELECOMMUNICATIONS SPACES
Electrical Safety Authority
Grounding.
TELECOMMUNICATION. Communication over a long distance.
Institute of Electrical Power Systems Institute of High Voltage Engineering and Systemmanagement NEW WAYS TO INTEGRATE GROUNDING, EQUIPOTENTIAL BONDING,
“HVDC TRANSMISSION” SUNIT KUMAR SAHOO REG NO-S BRANCH-EEE PREPARED BY.
Dr.F. Arteche EMC DEPFET Project: A general overview.
ESS Grounding System Concept Fundamentals and Requirements
Developing Cabling Module Situation at August 2006 Vello Vanem.
EMC issues for cabling and racks layout design. (Belle II – Grounding) F.Arteche.
Electrical and RF Safety. Electrical Safety Generators Generators convert mechanical energy to electrical energy. They actually consist of two devices:
HVDC Transmission.
SunSpec EMC Compatibility Considerations Charles Razzell.
IEEE NPEC SC2 Equipment Qualification Electromagnetic Compatibility Compliance Type Test-Design Considerations- Installation and Mitigation Standard/Guidance.
Smitty’s Two Minute Drill Grounding
Graz University of Technology May 11th – 12th Maribor, Slovenia
Principles of Audio System Grounding and Signal Integrity
Transmission Media (Coaxial Cable and Twisted Pair) Khaled Al Otaishan
Grounding.
Lecture 4: Wave Propagation Concept
Basic Electrical Circuits
LIGHTNING AND INSULATIONS COORDINATION
1-2 Grounding Principles and CF Infrastructure in Instruments Halls
Physics 16 Electromagnetism
Physics 16/21 Electromagnetism
Physics 133 Electromagnetism
Transmission Media 1 INTRODUCTION 2 GUIDED MEDIA 3 UNGUIDED MEDIA 7.#
Grounding Myths.
Presentation transcript:

ElectroMagnetic Compatibility in Cable Tray Systems Ed Cronin, RCDD, President, Cronin Consulting Claes Rosenberg, Export Manager, Defem System/Schneider Electric

EMC Research Consortium

Definition of ElectoMagnetic Compatibility ”The ability of a device, equipment or system to function satisfactorily in its electromagnetic environment without introducing intolerable electromagnetical disturbances to anything in that environment” Source: 2008 International Electrical Committee (IEC)

EMC in the Data Room The metal cable tray is part of the electrical structure The metal cable tray is part of the metallic structure Any metallic structure is known as a “generalized shield”

Definition of generalized shield To function as a generalized shield, the metal does not have to be enclosing the cable. Any continous metal along the cable is a shield. A shield is any metal structure that is continous and parallel along the cable path

Metal Cable Tray Quick Facts Properly bonded and grounded = ”earth” Poorly bonded and grounded = ”antenna”

Background July 2007 - EU introduces new EMC directive It states that any electrical installation shall be made according to ”good engineering EMC practice”

EU Directive ...”installer must document that the EMC performance of complete installation is made according to ”good engineering practice” ... Source: EMC Directive 2004/108/EC

“Come and go problems” “Slow down problems” Common EMC Problems Lightning strike on/off transients radio transmission “Slow down problems” Disturbances may force packaged signals to be re-packaged and re-sent

Principles of Generalized Shield Equipment Metal structure Cables Differential mode

Various Shield Structures

Principles of Earth Loop Area Reduction

Principles of Earth Loop Area Reduction

Principals of Earth Loop Area Reduction

Principles of Earth Loop Area Reduction

Tray Design Minor Importance wire mesh solid metal tray perforated metal tray cable ladder …are all “shield” when properly installed

Schneider Electric tests performed with Defem cable tray

Ultimate installation Tray directly connected to top of cabinets Floor is Ground Reference Plane.

Realistic installation Tray connected with short ground wire to top of both cabinets

Possible installation Tray connected with long ground wire to low point of both cabinets

Poor installation Tray connected once with a single ground wire to one cabinet

Schneider Electric Results

Test Conclusions Single ground connection Continous tray installation Tray connected to one cabinet only worse than no metal tray at all creates a disturbance Continous tray installation Tray from cabinet to cabinet best option not realistic for practical reasons

Test Conclusions Realistic installation Critical Parameter Sort ground wire between tray and all cabinets clear improvement Critical Parameter connection between cable trays and cabinets continuity of generalized shield

Other Conclusions Source and victim cables at bigger separation distance does not compensate for a badly connected cable tray. It is still contagious…

Good Engineering Practices IEC Standards To use gasfree and vibration safe joinings of tray, ensuring max 50mΩ To mark tray joints with a bonding sign To connect metal cable trays to all cabinets with ground wire, preferrably at cable entrance

Good Engineering Practices Place cables as close as possible to parallel earth conductor

Good Engineering Practices Additional cables will enhance external shielding effect

Good Engineering Practice With multi level cabling, ground wire connection between tray levels

Take Away Properly bonded and grounded = ”earth” Poorly bonded and grounded = ”antenna”

Thank You Claes Rosenberg – Defem Ed Cronin RCDD – Cronin Consulting

Thank You