Session 4 Atomic Mass Spectrometry

Slides:



Advertisements
Similar presentations
FTIR ● Quite often EDS analysis will give only C and O peaks meaning that the material is organic. ● FTIR is sensitive to vibrations between bonds in materials.
Advertisements

FC-MS from Teledyne Isco CombiFlash ® a Name You Can Rely On.
Focused ion beam (FIB) 1.Overview. 2.Ion source and optics. 3.Ion-solid interaction, damage. 4.Scanning ion beam imaging. ECE 730: Fabrication in the nanoscale:
Atomic Absorption & Emission Spectroscopy
Chem. 133 – 4/13 Lecture. Announcements I Exam 2 Results: Ave = 55% (10% below last year’s) Lab: Should finish Set 2 Period 4 lab today Thursday is make-up.
Atomic Mass Spectrometry Yongsik Lee Introduction ► Atomic mass spectrometry  Versatile and widely used tool  All elements can be determined ►
Ion Sources Some characteristics of ion sources (especially in high precision work): It should have high efficiency in generating ions of the element of.
Chapter 10 ATOMIC EMISSION SPECTROMETRY
AAS and FES (Ch 10, 7th e, WMDS)
Inductively Coupled Plasma Mass Spectrometry or ICP-MS
IDDepth δ 13 CCarbonNitrogenδ 13 C Depth: (cm)(‰)(%) (‰)(cm) Gr. 3-5A %0.17% Gr %0.12% Gr %0.09%
12-1 Molecular Mass Spectroscopy Molecular structure Composition of mixtures Molecular mass spectra Ion Source Mass Spectrometers Applications.
AAS and FES (Ch 9, 7th e, WMDS)
AA and Atomic Fluorescence Spectroscopy Chapter 9
INTRODUCTION TO OPTICAL METHODS
1 Atomic Absorption Spectroscopy. 2 Atomic Transitions: Excitation and Emission.
Flame photometry.
Atomic Emission Spectroscopy
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Mass Spectroscopy Mass Spectrometry ä Most useful tool for molecular structure determination if you can get it into gas phase ä Molecular weight of.
Chapter 20 Molecular Mass Spectrometry. Introduction... Mass spectroscopy is perhaps one of the most widely applicable of all the analytical tools available.
announcements and reminders
Instrumental Chemistry Chapter 11 Atomic Mass Spectrometry.
Lecture 2 M.Sc.. AA Spectrometer Components Lamp and FlameDetector Fuel Oxidant Nebulizer Double-Click picture for VIDEO.
Atomic Emission - AES M* → M + hn Thermal excitation M → M*
Atomic Mass Spectrometry
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Atomic-Absorption (AA) Spectroscopy 
Atomic Mass Spectrometry
Molecular Mass Spectrometry
Chem415 Quantitative Bio-Element Imaging Center (QBIC): Part I APRIL 10, 2015 DIRECTOR: PROFESSOR THOMAS V. O’HALLORAN MANAGING DIRECTOR: KEITH MACRENARIS,
6. Mass Spectrometry Adv. Inst. Techs. How does it work? a very small amount of sample is bombarded by a beam of high energy (usually electron beam) produces.
Agilent 7500 ICP-MS Date: 28JUL2005.
Secondary Ion Mass Spectrometry (SIMS)
Atomic Emission Spectroscopy
Atomic Emission Spectrometry
Chapter 8 – Mass Spectrometry. Mass Spectrometry The mass spectrometer can be used for: – Quantitative analysis – as a sophisticated and very sensitive.
PC4250 Secondary Ion Mass Spectrometry (SIMS). What is SIMS? SIMS is a surface analysis technique used to characterize the surface and sub-surface region.
Secondary ion mass spectrometry (SIMS)
Mass spectrometry Ions are analyzed on the basis of their m/z Chlorine has 2 isotopes, 35 Cl and 37 Cl, in the approximate ratio of 3 :1. Electrons are.
Atomic Absorption Spectroscopy
Year 12 Chemistry Unit 3 – AOS 1 Chemical Analysis.
Mass spectrometry and the PITZ Sven Lederer Technisches Seminar
Advanced Analytical Chemistry – CHM 6157® Y. CAIFlorida International University Updated on 9/28/2006Chapter 6Electron Spectroscopy Chapter 6 Electron.
1 Chemical Analysis by Mass Spectrometry. 2 All chemical substances are combinations of atoms. Atoms of different elements have different masses (H =
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 20
Atomic spectroscopy Elemental composition Atoms have a number of excited energy levels accessible by visible-UV optical methods ä Must have atoms (break.
Adv. Inst. Techs.  flame emission (eg flame photometer) known as low temperature emission ( K) ◦ first form of spectroscopy ◦ used in commercial.
Chemistry Topic: Atomic theory Subtopic : Mass Spectrometer.
7-1 Atomic Mass Spectroscopy General Features Mass Spectrometers §Sources Atomic mass spectroscopy determines elements by mass §Mass to charge ratio §Lower.
For all CHEM5161 students: The first day of class for CHEM5161 (Analytical Spectroscopy) will be on TUE Sept 4 (following Labor Day). There will be no.
Mass spectrometry (Test) Mass spectrometry (MS) is an analytical technique that measures masses of particles and for determining the elemental composition.
Combining and Choosing Analytical Techniques Chapter 8.
Advanced Analytical Chemistry – CHM 6157® Y. CAIFlorida International University Updated on 9/26/2006Chapter 3ICPMS Interference equations Isobaric.
Eliminating Molecular Interferences in ICP-MS for the Simplest Method Development Dr. Torsten Lindemann.
Secondary Ion Mass Spectrometry A look at SIMS and Surface Analysis.
LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY
X-ray absorption spectroscopy (XAS)
Plasma A Plasma consists of a collection of free-moving electrons and ions and is very hot. Energy must be continually applied to sustain the plasma.
Chem. 133 – 4/4 Lecture. Announcements I Strike – If the strike occurs, it will affect classes April 14 th and 18 th (unless ended early) – Lab: would.
Chem. 133 – 4/12 Lecture. Announcements I Strike – No Strike now planned Exam 2: – Average was 77 (range 61 to 93) Last HW Set (Set 3 – see handout) Lab.
Chemistry 4631 Instrumental Analysis Lecture 18 Chem 4631.
Chapter 29 Mass Spectrometry. 29 A Principles of mass spectrometry In the mass spectrometer, analyte molecules are converted to ions by applying energy.
Flame Emission Spectrometry
Chem. 133 – 3/30 Lecture.
Chem. 133 – 4/20 Lecture.
Mass Spectroscopy. Mass Spectroscopy Mass Spectrometry Most useful tool for molecular structure determination if you can get it into gas phase Molecular.
Elemental composition
Instrumental Chemistry
Atomic Absorption Spectroscopy. Atomic absorption spectroscopy is based on the same principle as the flame test used in qualitative analysis.
Inductively Coupled Plasma
Presentation transcript:

Session 4 Atomic Mass Spectrometry Comparison of different techniques for trace analysis

Crucial steps in atomic spectroscopies and -metries and other methods Laser ablation etc. Nebulisation Solid/liquid sample Molecules in gas phase Solution Desolvation Sample preparation M+ X- Vaporisation MX(g) M(g) + X(g) Atomisation= Dissociation Atoms in gas phase Sputtering, etc. Excitation M+ Ionisation Ions Excited Atoms ICP-MS and other MS methods (also: ICP-OES)  AAS and AES, X-ray methods Adapted from www.spectroscopynow.com (Gary Hieftje)

ICP-MS Mass spectrometry method: detects ions distinguished by their mass-to-charge ratio (m/z value) Based on ions moving under influence of electrical or magnetic field Mass analysers generally require operation under vacuum, to avoid ions colliding with other particles Recommended series of short articles: Robert Thomas: A beginner’s guide to ICP-MS

ICP-MS instrumentation and principle Detector (e.g. electron multiplier) Plasma generates positive ions Under vacuum nebuliser Interface Sorted by mass analyser, e.g. quadrupole, magnetic sector, according to m/z ratio Spray chamber sample http://www.cee.vt.edu/ewr/environmental/teach/smprimer/icpms/icpms.htm

ICP-MS instrumentation Sampling cone Collision cell Detector (discrete dynode) ICP Torch Mass Analyser: Quadrupole Cones and Ion Optics Skimmer cone Modern instrument with collision/reaction cell

Recap: Ion formation in an inductively-coupled plasma Mostly, singly charged positive ions are generated (>90% efficiency)

Interface and ion optics Room temperature, vacuum 6000 K, ambient pressure ICP torch Major challenge in instrumentation: large differences in temperature and pressure. Interface (consisting of two cones) allows connecting ion source to mass analyser (requires vacuum) Lens focuses ions. Necessary for getting as many ions as possible into analyser (maximising signal)

Mass analysers for ICP-MS Quadrupole: High mass stability, fast Lowest cost option Time-of-Flight (rare) HR (High-resolution): Uses magnetic sector mass analyser Highest sensitivity and resolution, but slow and requires stable working environment Expensive Multi-collector (MD): Also with magnetic sector, but with detector array Good for accurate and precise isotope ratios Isotope dilution measurements – e.g. for accurate elemental ratios

Quadrupole mass analyser Four parallel metal rods with dc and ac voltage (alternating with radiofrequency) Works as mass filter: allows passage of particular m/z ions only Can scan over m/z range  spectrum

Atomic mass spectra Ray and Hieftje, J. Anal. At. Spectrom., 2001, 16, 1206-1216 http://www.wcaslab.com/tech/tbicpms.htm

Typical detection limits of ICP-MS instrument http://las.perkinelmer.co.uk/content/TechnicalInfo/TCH_ICPMSThirtyMinuteGuide.pdf

Multi-collector mass analyser Magnetic sector mass analyser separates ions according to m/z Simultaneous detection with array of collectors (Faraday cups) Best for detn. of isotope ratios Applications in geochemistry and biomedical research

Possible factors that can affect the performance of ICP-MS Variations in plasma ionization efficiency Possible clogging or corrosion of cone apertures Differing concentrations of other components in matrix (e.g. acid, bulk elements) in samples could result in matrix suppression Ion current influenced by matrix composition Temperature and humidity fluctuations in the laboratory environment Isobaric elemental and polyatomic interferences: Used to be greatest limitation for applicability

Polyatomic interferences in ICP-MS: Origins Spectral interference: caused by presence of species with same mass as analyte Often derived from compounds with Ar Analyte Interference 39K+ 38Ar1H+ 40Ca+ 40Ar+ 51V+ 35Cl16O+ 52Cr+ 40Ar12C+ 56Fe+ 40Ar16O+ 63Cu+ 23Na40Ar+ 75As+ 40Ar35Cl+ 80Se+ 40Ar2+

Overcoming polyatomic interferences: Collision/reaction cells (CRC technology) Various modes of action: Collision-induced dissociation (less important) Chemical reaction (major mechanism) Electron transfer (major mechanism) KED: kinetic energy discrimination (monoatomic analyte and interfering molecules are retarded differently) Can either affect analyte or interference Commonly used gases: He, H2, ammonia Requires reactive gas http://breeze.thermo.com/collisioncells/ (Webinar)

Polyatomics and high-resolution ICP-MS also no problem with polyatomics, as there are small, resolvable differences in mass: 31P 16O16O 14N16O1H 15N16O 32S 30.95 31.00 31.95 32.00 Mass (u)

Stable isotopes and their uses Most elements have more than one isotope E.g. 32S and 34S, or 56Fe and 57Fe Can use more than one mass for one element for measurements in ICP-MS IDSM: Isotope dilution mass spectrometry: Use particular isotope of desired analyte as internal standard in ICP-MS Can buy enriched compounds, e.g. 67ZnO, and use as “tracers”

Example for use of stable isotopes Metal-binding protein with 4 Zn(II) Are all four zinc ions exchangeable ? Isolated with natural abundance Zn(II): 10 20 30 40 50 60 64 66 67 68 70 % 67Zn: 4.1% Isotope Incubated overnight at 37°C with 40 mol equivalents of 67Zn(II) (93% isotopic purity) Measured isotopic ratios

Measurement and output (Thermofinnigan Element2) Total Zn and total S were determined using standard addition. For Zn quantification, the sum of the Zn isotopes 64, 66, 67, 68 and 70 was used. S was measured on the 32S isotope. Zn isotopic distribution (64, 66, 67, 68, 70) was determined. All elements and isotopes were measured in Medium Resolution (R = 4000). No internal standard has been used. No mass bias correction (using certified materials) was used for the isotopic distribution measurement. Sample preparation: Sample was diluted 1+49 with 18 MΩ water. For blank subtraction, the 10 mM NH4Acetate buffer was diluted 1+49 with 18 MΩ water. Results for sample: Total S 2.45 mg/L (± 0.2 %) Total Zn 2.21 mg/L (± 0.6 %) Ratios: 66Zn / 64Zn 0.657 ± 0.0028 (n = 7) 67Zn / 64Zn 4.17 ± 0.025 (n = 7) 68Zn / 64Zn 0.490 ± 0.0037 (n = 7) 70Zn / 64Zn 0.01325 ± 0.00007 (n = 7)  S: Zn ratio: 9:4 (as expected; the protein contains 9 sulfurs)

Comparison of experimental and calculated isotopic ratios Calculated for 4 exchanging Zn(II) As measured Calculated for 3 exchanging Zn(II) 66/64 67/64 68/64 70/64 For each isotopic ratio, results agree best with the scenario for 3 exchanging zinc: Clear demonstration that only 3 out of 4 Zn exchange: The protein has one zinc that is inert towards exchange

ICP-MS and hyphenation ICP-MS can be coupled with a variety of separation techniques: Liquid chromatography  HPLC-ICP-MS Capillary electrophoresis  CE-ICP-MS Advantages of hyphenated techniques: better control over matrix Allows separation of different components: direct access to speciation Laser ablation  LA-ICP-MS For surface analysis For materials that are difficult to digest (e.g. alloys) Is being developed in scanning fashion with mm spatial resolution: Imaging the metal composition of a material Caveat: Calibration ?

Laser ablation Useful for surface analysis of solid samples monitor camera UV light Laser To ICP Carrier gas in sample

The ablation process Plume of molecules and ions from a surface hit by a laser http://kottan-labs.bgsu.edu/pictures/

Comparison: AAS, ICP-OES, and ICP-MS AAS: Single element, ppm/ppb range Cheap, simple Small dynamic range GFAAS about 100 times more sensitive than FAAS, but also more challenging ICP-OES: Multi-element, ppb range Limited spectral interferences, good stability, low matrix effects ICP-MS: Multi-element, possible to reach ppt (or even ppq) Most complex, most expensive, lowest detection limits, isotope analysis possible

Comparison: Detection limits and working ranges http://pubs.acs.org/hotartcl/tcaw/99/oct/element.html

Synopsis: Interferences in atomic spectroscopy Technique Type of Interference Method of Compensation Flame AAS Ionization Chemical Physical Ionization buffers Releasing agent or nitrous oxide-acetylene flame Dilution, matrix matching, or method of additions  Graphite Furnace AAS Physical and chemical Molecular absorption Spectral Spectral Standard Temperature Platform Furnace (STPF), conditions, standard additions Zeeman or continuum source background correction Zeeman background correction ICP-OES Matrix Background correction or the use of alternate analytical lines Internal standardization ICP-MS Inter-element correction, use of alternate masses, higher resolution systems or reaction/collision cell technology Internal standardization http://pubs.acs.org/hotartcl/tcaw/99/oct/table1.html

A technique decision matrix Exercise: How is this decision matrix correlated with strengths and limitations of the various techniques ? http://las.perkinelmer.com/content/relatedmaterials/brochures/bro_atomicspectroscopytechniqueguide.pdf

Other inorganic mass spectrometry methods Mainly for surface analysis (depth profiling, imaging) in different materials (e.g. conducting, semiconducting, and nonconducting solid samples; technical, environmental, biological, and geological samples) Spark source mass spectrometry (SSMS) Glow discharge mass spectrometry (GDMS) Laser ionization mass spectrometry (LIMS) Thermal ionization mass spectrometry (TIMS) Secondary ion mass spectrometry (SIMS): most sensitive elemental and isotopic surface analysis technique Sputtered neutral mass spectrometry (SNMS) Detection limits for the direct analysis of solid samples by inorganic solid mass spectrometry: down to ppb levels

SIMS: secondary ion mass spectrometry One of the most widespread surface analysis techniques for advanced material research Principle: bombard surface with ions, “secondary” ions are sputtered from surface High sensitivity for all elements Any type of material that can stay under vacuum (insulators, semiconductors, metals) Potential for high-resolution imaging (down to 40 nm) Very low background: high dynamic range (more than 5 decades) Quantitative work complicated by variations in secondary ion yields in dependence on chemical environment and the sputtering conditions (ion, energy, angle) Rapid deterioration of bombarded surface Static SIMS: Molecular and elemental characterisation of top monolayer Dynamic SIMS: Bulk composition or depth distribution of trace elements. Depth resolution ranging from one to 20-30 nm