Pair Spectrometer Design Optimization Pair Spectrometer Design Optimization A. Somov, Jefferson Lab GlueX Collaboration Meeting September 9 2009.

Slides:



Advertisements
Similar presentations
Measuring the Neutron and 3 He Spin Structure at Low Q 2 Vincent Sulkosky College of William and Mary, Williamsburg VA Experimental Overview The.
Advertisements

Proposal for a new design of LumiCal R. Ingbir, P. Ruzicka, V. Vrba October 07 Malá Skála.
Hall D Photon Beam Simulation and Rates Part 1: photon beam line Part 2: tagger Richard Jones, University of Connecticut Hall D Beam Line and Tagger Review.
Upcoming Review of the Hall D Photon Beam and Tagger Richard Jones, University of Connecticut, for the GlueX collaboration GlueX Collaboration Meeting.
Status of the Tagger Hall Background Simulation Simulation A. Somov, Jefferson Lab Hall-D Collaboration Meeting, University of Regina September
Tagger Electronics Part 1: tagger focal plane microscope Part 2: tagger fixed array Part 3: trigger and digitization Richard Jones, University of Connecticut.
Tagger hodoscope and photon beam monitoring D.Sober, F.Klein (CUA) Tagger Review, Jan.23-24, 2006.
Accelerator hall of the S- DALINAC – electron energies from 2 to 130 MeV available – cw and pulsed beam operation possible – source for polarized electron.
The GlueX Photon Beam Richard Jones, University of Connecticut GlueX Photon Beamline-Tagger ReviewJan , 2005, Newport News presented by GlueX Tagged.
Tagger and Vacuum Chamber Design. Outline. Design considerations. Stresses and deformations. Mechanical assembly.
The Tagger Microscope Richard Jones, University of Connecticut Hall D Tagger - Photon Beamline ReviewJan , 2005, Newport News presented by GlueX.
Photon Source and Tagger Richard Jones, University of Connecticut GlueX Detector ReviewOctober 20-22, 2004, Newport News presented by GlueX Tagged Beam.
Tagging Near the End-Point Richard Jones, University of Connecticut GlueX Collaboration Meeting, Newport News, May 8-10, Current design capabilities.
Tagging spectrometer and photon beamline Review January 23-24, Response to Questions Bremsstrahlung Tagging Spectrometer and Photon Beam Review.
Study of two pion channel from photoproduction on the deuteron Lewis Graham Proposal Phys 745 Class May 6, 2009.
experimental platform
Tagger and Vacuum Chamber Design. Outline. Design considerations. Stresses and deformations. Mechanical assembly.
Prajwal T. Mohan Murthy Laboratory for Nuclear Science, MIT νDM Group Spin-Light Polarimeter for the Electron Ion Collider EIC Users Meeting 2014 Jun 2014.
Bogdan Wojtsekhowski, Jefferson Lab Experimental search for A’ for APEX collaboration 1.
M. Woods (SLAC) Beam Diagnostics for test facilities of i)  ii) polarized e+ source January 9 –11, 2002.
PAIR SPECTROMETER DEVELOPMENT IN HALL D PAWEL AMBROZEWICZ NC A&T OUTLINE : PS Goals PS Goals PrimEx Experience PrimEx Experience Design Details Design.
The PEPPo e - & e + polarization measurements E. Fanchini On behalf of the PEPPo collaboration POSIPOL 2012 Zeuthen 4-6 September E. Fanchini -Posipol.
HYP03 Future Hypernuclear Program at Jlab Hall C Satoshi N. Nakamura Tohoku University 18 th Oct 2003, JLab.
Medium heavy Λ hyper nuclear spectroscopic experiment by the (e,e’K + ) reaction Graduate school of science, Tohoku University Toshiyuki Gogami for HES-HKS.
Status of the Beamline Simulation A.Somov Jefferson Lab Collaboration Meeting, May 11, 2010.
SHMS Optics and Background Studies Tanja Horn Hall C Summer Meeting 5 August 2008.
The GlueX Detector 5/29/091CIPANP The GlueX Detector -- David Lawrence (JLab) David Lawrence (JLab) Electron beam accelerator continuous-wave (1497MHz,
AWAKE Electron Spectrometer Simon Jolly, Lawrence Deacon, Matthew Wing 28 th January 2015.
Measurement of Gas Bremsstrahlung at the Pohang Light Source Hyosang Lee Seoul National University, Q2C Pusan National University, HANUL HNP2011.
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
Status of Møller Polarimeter Peter-Bernd Otte September 23, th Collaboration Meeting, Mainz.
SHMS Optics Studies Tanja Horn JLab JLab Hall C meeting 18 January 2008.
Yosuke Watanabe….. University of Tokyo, RIKEN A, KEK C, Development of a GEM tracker for E16 J-PARC 1 Thanks to ???????????
HPS Beamline: Background Rates, Sensitivity to Field Uncertainties M. Ungaro1HPS Collaboration Meeting, JLAB, May Concrete Wall thickness Study.
Status of Moeller Polarimeter Peter Otte April 7, th Collaboration Meeting, Dubrovnik.
PrimEx collaboration meeting Energy calibration of the Hall B bremsstrahlung tagging system using magnetic pair spectrometer S. Stepanyan (JLAB)
M. Dugger, February Triplet polarimeter study Michael Dugger* Arizona State University *Work at ASU is supported by the U.S. National Science Foundation.
HPS T EST R UN C ONTINGENCY P LAN S. Stepanyan JLAB.
GlueX Collaboration Meeting. Jefferson Lab. September 9 – 11, Review of Tagger System.
Latifa Elouadrhiri Jefferson Lab Hall B 12 GeV Upgrade Drift Chamber Review Jefferson Lab March 6- 8, 2007 CLAS12 Drift Chambers Simulation and Event Reconstruction.
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Measuring the charged pion polarizability in the  →    −  reaction David Lawrence, JLab Rory Miskimen, UMass, Amherst Elton Smith, JLab.
GlueX Two Magnet Tagger G. Yang University of Glasgow Part 1, 3 D Tosca analysis. Part 2, Preliminary Drawings. Part 3, Proposed Assembly Procedures (i)
Photon Flux Control Liping Gan UNCW. Outline PrimEx-  experiment requirement Tagged photon Procedure to obtain the number of tagged photons Relative.
Lecture 9: Inelastic Scattering and Excited States 2/10/2003 Inelastic scattering refers to the process in which energy is transferred to the target,
1 Yuri Shestakov Budker Institute of Nuclear Physics Novosibirsk, Russia Tagging system of almost-real photons for photonuclear experiments at VEPP-3 Moscow,
Calorimetry for Deeply Virtual Compton Scattering in Hall A Alexandre Camsonne Hall A Jefferson Laboratory Workshop on General Purpose High Resolution.
Pad design present understanding Tel Aviv University HEP Experimental Group Ronen Ingbir Collaboration High precision design Tel-Aviv Sep.05 1.
Photon Source and Tagger Richard Jones, University of Connecticut GlueX Detector ReviewOctober 20-22, 2004, Newport News presented by GlueX Tagged Beam.
Magnetized hadronic calorimeter and muon veto for the K +   +  experiment L. DiLella, May 25, 2004 Purpose:  Provide pion – muon separation (muon veto)
J-PARC でのハイパー核ガンマ線分光実験用 散乱粒子磁気スペクトロメータ検出器の準備 状況 東北大理, 岐阜大教 A, KEK B 白鳥昂太郎, 田村裕和, 鵜養美冬 A, 石元茂 B, 大谷友和, 小池武志, 佐藤美沙子, 千賀信幸, 細見健二, 馬越, 三輪浩司, 山本剛史, 他 Hyperball-J.
Jan. 18, 2008 Hall C Meeting L. Yuan/Hampton U.. Outline HKS experimental goals HKS experimental setup Issues on spectrometer system calibration Calibration.
An electron/positron energy monitor based on synchrotron radiation. I.Meshkov, T. Mamedov, E. Syresin, An electron/positron energy monitor based on synchrotron.
 0 life time analysis updates, preliminary results from Primex experiment 08/13/2007 I.Larin, Hall-B meeting.
Calibration of energies at the photon collider Valery Telnov Budker INP, Novosibirsk TILC09, Tsukuba April 18, 2009.
Electron Spectrometer: Status July 14 Simon Jolly, Lawrence Deacon 1 st July 2014.
Photon Source and Tagger Richard Jones, University of Connecticut GlueX Detector ReviewOctober 20-22, 2004, Newport News presented by GlueX Tagged Beam.
SPring-8 レーザー電子光 ビームラインでの タギング検出器の性能評価 核物理研究センター 三部 勉 LEPS collaboration 日本物理学会 近畿大学 1.レーザー電子光 2.タギング検出器 3.実験セットアップ 4.エネルギー分解能 5.検出効率とバックグラウンドレート.
Proposal for the End Station Test Beam (ESTB) at SLAC John Jaros ALCPG09 Albuquerque September 30, 2009.
Tagger and Vacuum Chamber Design Jim Kellie Glasgow University.
Simulation / reconstruction with GEMs at DAC A.Zinchenko, A.Kapishin, V.Vasendina for the collaboration VBLHEP, JINR, Dubna,
R. Arnold SLAC 24 June 2002 Real Photon Collaboration Conceptual Design Review Beam Monitoring Instruments.
MAGIX Detectors Overview
Polarized WACS Experiment (E ) Using Compact Photon Source (CPS)
A. Gasparian NC A&T State University, Greensboro, NC
Preparation of the CLAS12 First Experiment Status and Time-Line
Progress on J-PARC hadron physics in 2016
Special Considerations for SIDIS
GEANT Simulations and Track Reconstruction
CLIC luminosity monitoring/re-tuning using beamstrahlung ?
Presentation transcript:

Pair Spectrometer Design Optimization Pair Spectrometer Design Optimization A. Somov, Jefferson Lab GlueX Collaboration Meeting September

Outline  Asymmetric-energy design of Pair Spectrometer based on scintillator counters  Symmetric-energy design. Instrumentation of Pair Spectrometer with microstrip/GEM detectors - detector size - energy resolution - detector pitch size - rate - selection of PS magnet and length of the vacuum chamber Pair Spectrometer Design Optimization, Hall-D Collaboration Meeting, September

Main components:  Thin target (10 -3 radiation length)  Dipole magnet m long T in the gap.  1.5 m long vacuum chamber  Hodocope counters: - 24 FSF counters (positrons) all tilted by 15  - 6 WSF counters (electrons) tilted individually by  Current Design of Pair Spectrometer  Proposed by H.Hakobyan  Based on a few readout channels ( scintillator counters ) Pair Spectrometer Design Optimization, Hall-D Collaboration Meeting, September

Energy Resolution FSF counters WSF counters FSF counters: - 24 counters cover the energy range from 3 GeV to 4 GeV - counter’s width 0.61 – 1.11 cm (  ~ 12 MeV ) WSFcounters: 6 counters: 3.25, 4.25, 5.25, 6.25, 7.25, 8.25 GeV counter width 0.2 – 1.36 cm (  ~ 17 MeV ) Converter thickness L = 5x10 -3 X 0 Resolution at the photon end-point energy region is about 50 MeV - dominated by the beam spot size of about 4 mm at the converter Reconstructed photons Pair Spectrometer Design Optimization, Hall-D Collaboration Meeting, September

Energy Spectrum Pair Spectrometer Design Optimization, Hall-D Collaboration Meeting, September Photon energy spectrum 5  X 0 converter high-luminosity runs 24 x 6 = 144 energy bins

Current Design Summary - Precise measurement of the photon flux stability with the required accuracy of about 1% - Determination of the photon polarization with the accuracy of a few % Disadvantages: small counter acceptance ( less than 0.1% ), spacial separation of the counters - potential difficulties with the counter acceptance determination relatively poor energy resolution of reconstructed photons at the end-point region - calibration of the tagger microscopes using Pair Spectrometer require huge magnet (BNL 30D72 magnet, weight 64 tons, gap size 6  - has to be reduced ) Study feasibility of the alternative symmetric-energy design Pair Spectrometer Design Optimization, Hall-D Collaboration Meeting, September

Detector Size Detector width as a function of the magnetic field Study energy resolutions/rates of the microstrip detectors: - use ‘default’ lengths of the vacuum chamber and the magnet - lower magnetic ffield to 1.1 T ( 1.98 T m ) detector width ~26 cm - symmetric-energy range GeV for both e  arms Pair Spectrometer Design Optimization, Hall-D Collaboration Meeting, September

Energy Resolution  Initial spread of the polar angle distribution of e  in photon pair production  Multiple scattering of e  in the converter  Photon beam spot size/emittance at the converter  Pitch size of the detectors Pair Spectrometer Design Optimization, Hall-D Collaboration Meeting, September

Initial Angular Spread of e  in Pair Production Pair Spectrometer Design Optimization, Hall-D Collaboration Meeting, September r.m.s.  GAUSS

Energy Resolution: Initial Angular Spread & Multiple Scattering Optimization of Tagger Magnet Optics, Collaboration Meeting, JLab 10 Pair production Multiple Scattering ( 2  X 0 )  GAUSS r.m.s. Correlation between e + and e – angles Pair production angle dominates energy uncertainties up to ~ 5  X 0

Energy Resolution: Beam Spot Size Pair Spectrometer Design Optimization, Hall-D Collaboration Meeting, September Relative energy shift of reconstructed photons as a function of the fractional electron energy E e / E  Pencil beam photons shifted by  X = 2.5 mm at the converter  E  ~ 0

Overall Energy Resolution Pair Spectrometer Design Optimization, Hall-D Collaboration Meeting, September | E e / E  | < 0.02 Full Geant detector simulation 3.4 mm primary collimator X 0 converter

Pair Spectrometer Rates Pair Spectrometer Design Optimization, Hall-D Collaboration Meeting, September Background random coincidence rate: - estimated to be on the level of 1% - design of the tapered collimators should be optimized All e + e - coincidences

BNL Magnet 18D36 Pair Spectrometer Design Optimization, Hall-D Collaboration Meeting, September  Several magnets available at BNL  Maximum field 2.2 T with 6  gap size ( 2200 A - 2 T, linear up to 1900 A) - reduce the gap size, operate at 1.5 T ( ~ 1.4 Tm ) - acceptance: E e > 0.9 GeV  20 tons, can be split in half  The same magnet is used in Hall-B ( 6  gap size ) - ‘reliable’ operation, mapped the field. Will try to find the calibration stand for us.

Resolution for Different Vacuum Chamber Length Pair Spectrometer Design Optimization, Hall-D Collaboration Meeting, September Detector width: 14 cm Pitch size: 400  m GEM (?) ( 350 x 2 = 700 channels) Energy resolution: ~10 MeV for 6 GeV e  ( 20 MeV for  )

Summary Pair Spectrometer Design Optimization, Hall-D Collaboration Meeting, September We performed a study of an alternative symmetric-energy instrumentation of the Pair Spectrometer which has several advantages compared with the default instrumentation: - better energy resolution - possibility to reduce energy uncertainties associated with the beam spot size - the acceptance of the microstrip detectors is expected to be easier to calibrate - possible to use smaller magnet (18D36 magnet is about 3 times lighter than 30D72)