Mechanical check of PMT Check base: Remove black tape and two small screws that secure the base. Tighten the nuts on the BNC connector for the HT input.

Slides:



Advertisements
Similar presentations
Constructing an Analog Digital Converter (ADC) to Measure Neutron Depolarization in Deuterium Aung Kyaw Sint and Dr. Alexander Komives CsI scintillator.
Advertisements

STAR Pixel Detector Phase-1 testing. 22 Testing interrupted LBNL-IPHC 06/ LG Lena Weronika Szelezniak born on May 30, 2009 at 10:04 am weighing.
Editing Process –Set up Decks, Monitors –Prepare Master Tape –Know operation of edit controller.
Measuring Cosmic Ray Flux with a trigger and CAMAC readout - Page 1 Connect the Fluke 415 HV supply output to the input of the voltage distribution box.
Design a Logic Probe Experiment 20. Design Specifications Design a logic probe as shown in the block diagram of Figure 1 of Experiment 20 with a signal.
COSMIC RAY MUON DETECTION USING SCINTILLATION COUNTER AND WAVELENGTH SHIFTING FIBERS ARUNODAYA BHATTACHARYA VSRP-2009,TIFR,MUMBAI 6/7/09.
Measurement of Light Transmission in Radiation Damaged Glued Quartz Bars for Q weak KATIE KINSLEY (Department of Physics, Ohio University, Athens, OH 45701)
Artemis Lite Fault Finding FAQ’s
ECAL and HCAL status 1Yu. Guz 2014/11/26. TED shots, 24-Nov 2Yu. Guz 2014/11/26.
Tutorial – “How to:” 1) Change the resolution on your display 2) Setup Multiple Displays.
Study of Photon Sensors using the Laser System 05/7/12 Niigata University, Japan Sayaka Iba, Editha P. Jacosalem, Hiroaki Ono, Noriko.
A Muon Veto for the Ultra Cold Neutron Asymmetry Experiment Vince Bagnulo with Dr. Jeff Martin Electrons Ultra Cold Neutrons Cosmic Ray Muons Protons Pions.
Hamamatsu Photonics K.K. Electron Tube Division R for ICECUBE 1.Delivery Record and Plan 2.Specification of R Test Result at Hamamatsu.
Power supply cable Charge injection 3 channels readout (external cables to the scope) 3 channels readout (internal cables) Set up for reading two cards.
One of our first tasks was to design permanent frames for the large scintillators. A ladder-like construct was chosen to be a light and strong way to protect.
Experimental Procedures Arrival at Desktop BASE Check that computer and DAQcard are still running. Sign in and start logbook entry (date and time). Note.
1 Lab Equipment. 2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope.
P. Karchin – PMTs for Scintillator Based Muon Systempage 11/7/2004 January 7, 2004 American Linear Collider Physics Group 2004 Workshop Stanford Linear.
October 1 -10, 2014JEM-EUSO Workshop - Toulouse1 Balloon – EUSO Xenon / UV LED Flasher Calibration Evgeny Kuznetsov for UAH / MSFC GLS team University.
Pulse Width Modulation (PWM) LED Dimmer Circuit
TIMERS.
Experiment 12 Non-Inverting Amplifier. Experimental Procedure Clarification in Step 3 (Modeling) – To perform the DC Sweep in the sinusoidal voltage source.
The next slide shows a simplified diagram of the pulser. A capacitor is charged up to perhaps 10V. Switches T1 and T2 close. Some of the capacitor current.
Photon detection Visible or near-visible wavelengths
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
Vladimir Frolov for Torino group. Experimental activities: The system for testing the MRPC in the Torino INFN laboratory has been fully mounted and checked;
1 System Description (2-4) Gains from single photo-electrons in vacuum at room temperature (5-8) Linearity Test at V in vacuum at room temperature.
Tests with JT0623 & JT0947 at Indiana University Nagoya PMT database test results for JT0623 at 3220V: This tube has somewhat higher than usual gain. 5×10.
Detectors - what detectors are available diamond / silicone - transport / shipping - 3 ROCs at UT? ROC Operation / Readout Modules (ED) - what modules.
Modelling of TPM noise problems Greg, following discussions and measurements with David and Senerath.
Cube Measurements Tent Crew. Scintillation BNL 241 Am Semi- collimated  Spectralon Diffuse UV Reflector SBD  -Trigger Scint. Light Poisson.
CAEN November 15, 2002 Vandelli W. 1 Test Conditions Prototype fed by CAEN Module 2527 through 100 m long cables From channels status page on generator.

14/02/2007 Paolo Walter Cattaneo 1 1.Trigger analysis 2.Muon rate 3.Q distribution 4.Baseline 5.Pulse shape 6.Z measurement 7.Att measurement OUTLINE.
1 Fulvio TESSAROTTO CERN, 23/04/ Contribution from Trieste UPDATE ON TRIESTE LAB. ACTIVITY The set-up to measure currents THGEM prototypes from ELTOS.
FLC Group Test-beam Studies of the Laser-Wire Detector 13 September 2006 Maximilian Micheler Supervisor: Freddy Poirier.
Sphere Standards and Standard Spheres Dr. Richard Young Optronic Laboratories, Inc.
Introducing gigahertz-bandwidth photodetectors for the visible and near-IR spectral range that provide highest performance-to-price ratio available today!
Status of Beam loss Monitoring on CTF3 Results of Tests on LINAC and PETS as R&D for TBL Anne Dabrowski Northwestern University Thibaut Lefevre CERN CTF3.
Vadodara Institute of Engineering kotanbi Active learning Assignment on Single phase AC CIRCUIT SUBMITTED BY: 1) Bhatiya gaurang.(13ELEE558) 2)
Abort Gap Monitoring Randy Thurman-Keup 6 / 8 / 2004 LARP Meeting.
ROBOX with Multi Anode PMT’s Status and plans A.Mestvirishvili, I. Schmidt, S. Sen, F. Ozok University of Iowa.
1 Fulvio TESSAROTTO CERN, 20/03/ GDD Meeting - Contribution from Trieste FIRST LOOK AT THGEM IN TRIESTE LAB. The set-up to measure currents THGEM.
LHCb HCAL PMT problems initial report 1 Yu. Guz. LHCb HCAL & ECAL 2 Yu. Guz PMTs of type HAMAMATSU R are used in both HCAL and ECAL. The detector.
Status of the ETL 9125FLB Photomultiplier Tubes Steve Bache UNC-Wilmington.
7/28/2003DC/EC Review Aerogel Read out Electronics K. Ozawa, N. Kurihara, M. Inaba, H. Masui T. Sakaguchi, T. Matsumoto.
Physics 2225: Faraday’s Law Purpose Study the induction of electric current according to Faraday’s Law.
Linearity Tests The laser induced high noise pulses on the APD rendering it useless. We tried several methods to shield and filter the noise. With a stabilized.
PMT-RAS. Turning the Clean Room Into a Dark Room.
CMS HF PMT SYSTEM By Y. ONEL U. of Iowa, Iowa City, IA CMS HCAL at Fermilab Feb 6-8, 2003.
SPD VFE installation and commissioning (status and plans) I.Summary of VFE installation II.Stand alone VFE test: noise & offset III.Stand alone test: LED.
The requirements of Ideal pulse-type counter :  1 Every particle entering the detector should produce a pulse at the exit of the counter,
1 Chapter No. 17 Radiation Detection and Measurements, Glenn T. Knoll, Third edition (2000), John Willey. Measurement of Timing Properties.
Casne.ncl.ac.uk Taking care of the CrumbleBot Please do NOT stress the robot's motors 1.Do NOT push the robot 2.Do NOT hold the.
Optical Calibration Updates Presentation for SK-UK Meeting 2016 Neil McCauley, Lauren Anthony, Adrian Pritchard, Joachim Rose 1.
 A) Pulse Height Spectroscopy  Identify the equipment such as detector, electronics modules and NIM.
PMT AFTERPULSE STUDIES By Ugur Akgun The University of Iowa.
E.Gushchin,S.Filippov(INR,Moscow) 16 April 2008Calo commissioning meeting CERN PS/SPD LED monitoring system status General status LED signal is used for.
The Working Theory of an RC Coupled Amplifier in Electronics.
The photomultiplier tubes selection for KM2A electromagnetic particle detectors (EDs) hou chao IHEP The 2nd workshop of air shower detection at high altitudes.
KM2A PMT testing platform FENG Cunfeng, LI Chaoju, SUN Yansheng Shandong University THE 2 nd WORKSHOP OF AIR SHOWER DETECTION AT HIGH ALTITUDES IHEP, Beijing,
JMU Dark Current Tests By: Kevin Nash.
Lets Design an LNA! Anurag Nigam.
AC Circuits AC Current peak-to-peak and rms Capacitive Reactiance
McCrometer Nano Board Test Procedure
The Life and Times of Cosmic-ray Muons
Comparator Circuits AIM:
Performance test of ACEM-detector (Aluminum Cathode Electron Multiplier) Marcus Palm AB-ATB-EA M. Palm, CERN.
6. USING THE TDR200 IN ANALOGUE MODE
Presentation transcript:

Mechanical check of PMT Check base: Remove black tape and two small screws that secure the base. Tighten the nuts on the BNC connector for the HT input and signal outputs if necessary. Reseat the PMT and tape the PMT to the base. Slide the shield back onto the PMT (be sure to connect the ground from the PMT shield to the base) and replace the screws and black tape. Setup Connect testing rig according to chart below. Check the LED source by moving the pulse width to maximum on the generator. A faint glow should be seen through the window in the LED block. Return the pulse width to 10 μs. Connect the PMT to the output cables and HT input and mount on the stand, with the end of the tube 50 cm from the LED source. Testing Set up a data table with 4 columns: Voltage, I-dark (0V), (I-dark (testV), and I-light (Voltage in kV, I in nA). Record the 0V current on the picoammeter (PAM). (The picoammeter’s baseline may shift over time.) Turn on the HV and raise the voltage to 1 kV. Record the test voltage dark current (Take aprrox. 10 sec to try and determine the mean value, the PAM reading will fluctuate considerably.) Turn on the LED by switching the polarity back to +. If PAM read OL switch back to – and seek problem. Record I-light. Switch off the LED and repeat measurements (I-dark (0V), I-dark (tV), I- light) up to 1.8 kV). I-dark (0V) can be recorded by disconnecting the BNC connector from the power supply to the PMT. If necessary, adjust the PAM range to 2 μa, but never allow the current to go above 1 μa. Replace PMT and repeat. PMT Mount in the dark box (50 cm from LED block) Acrylic Block with Embedded LED and Slit Window Thorn PMTs: acceptable sensitivity and SNR. The mean light current up to 1.5 kV is 7.9 nA. Individual Thorn PMT: current data and the net light current/net dark current ratio. A higher ratio represents low noise for the tube. Pulse width graph demonstrating the linear relationship between the LED pulse width and the output current. Hamamatsu PMTs: highest sensitivity and best SNR of all tubes. The mean light current up to 1.5 kV was 37.2 nA. The Hamamatsu tubes are considerably more sensitive than the PARTICLE and Thorn tubes. Consequently, the PMTs used in the detector will be Hamamatsu tubes. At operating voltage (1.4 kV) the mean current was 60.4 nA and the mean light current/dark current ratio was We decided to use an operating voltage of 1400 volts because beyond that there is no major increase of SNR, so there is no significant gain in sensitivity. Excepting a few bad tubes, most of the Thorn tubes had lower gain, but an acceptable SNR. At 1.5 kV the mean current was 26.2 nA and a 17.4 light current/dark current ratio. The RCA 6432 (PARTICLE) tubes intended for the smaller PARTICLE paddles were found to be noisy overall. They seemed to have the highest sensitivity and SNR at around 1.4kV, but often the dark current exceeded the light current. The mean dark current is nA higher than the mean light current. As result of the overall higher SNR they would not be appropriate for testing with the large scintillators. Testing Setup: Pictured are, from left to right, the dark box, the picoammeter, the pulse generator, the High Voltage source, and the oscilloscope. We evaluated two batches of 14-stage photomultiplier tubes for use in a large area muon detector: 8 Hamamatsu R5686 tubes and 26 Thorn 9954B tubes. The Hamamatsu tubes had the highest gain and displayed the best light to dark current ratio. At or below 1.5 kV the Hamamatsu tubes were 4.7x more sensitive to green light than the Thorn tubes. Since the Hamamatsu tubes were superior in both sensitivity and SNR, they were selected for use in the 10 ft. detectors. We applied our testing procedure to 22 RCA 6432 PMTs intended for the PARTICLE program detectors. As expected, these had lower gain, similar to the thorn tubes at low voltages. However, they had much higher dark current, particularly at high voltages. In order to find matching photomultiplier tubes (PMTs) to use in our muon detectors, the PMTs available had to be tested and sorted. The important characteristics to be measured were net output current light and the ratio of light current to dark current. Using a standard candle (pulsed green LED in acrylic block), a picoammeter, a pulse generator, a HV source, and an oscilloscope, the sensitivities and light to dark ratios of PMTs were measured. We started with 25 untested Thorn PMTs and 8 untested Hamamatsu tubes. The testing setup relied primarily on the linear nature of the light output of an LED, as seen in the far right frame. By controlling the light output of the LED with the pulse generator and measuring resulting output current from the PMT, the sensitivities and ratios of light current to dark current of the tubes were determined as a function of high voltage. The measured values were plotted as gain curves showing the sensitivity to light of the PMTs across a range of voltages. Through these graphs, the 4 most sensitive tubes were determined. Thorn vs. Hamamatsu: This demonstrates the superiority of the Hamamatsu PMTs.

We tested three distinct models of tubes: 8 Hamamatsu R5686 tubes, 26 Thorn 9954B tubes, and 22 Quarknet tubes. The Hamamatsu tubes were the most sensitive and displayed the best light to dark current ratio. At or below 1.5 kV the Hamamatsu tubes were 4.7x more sensitive than the Thorn tubes. The Thorn and Quarknet tubes had similar net light currents. It was discovered that the Quarknet tubes had an unsatisfactory signal to noise ratio (SNR), with measured dark current being considerably higher than the light current at high voltages. Since the Hamamatsu tubes were superior in both sensitivity and SNR, they were selected for use in the 10 ft. detectors.

In order to find matching photomultiplier tubes (PMTs) to use in our muon detectors, the PMTs available had to be tested and sorted. The important characteristics to be measured were net output current light and the ratio of light current to dark current. Using a standard candle (pulsed green LED in acrylic block), a picoammeter, a pulse generator, a HV source, and an oscilloscope, the sensitivities and light to dark ratios of PMTs were measured. We started with 25 untested Thorn PMTs and 8 untested Hamamatsu tubes. The testing setup relied primarily on the linear nature of the light output of an LED, as seen in the far right frame. By controlling the lighting of the LED with the pulse generator and measuring resulting output current from the PMT, the sensitivities and ratios of light current to dark current of the tubes were determined. The measured values were plotted as gain curves showing the sensitivity to light of the PMTs across a range of voltages. Through these graphs, the 4 most sensitive tubes were determined.

Mechanical check of PMT Check base: Remove black tape and two small screws that secure the base. Tighten the nuts on the BNC connector for the HT input and signal outputs if necessary. Reseat the PMT and tape the PMT to the base. Slide the shield back onto the PMT (be sure to connect the ground from the PMT shield to the base) and replace the screws and black tape. Setup Connect testing rig according to chart below. Check the LED source by moving the pulse width to maximum on the generator. A faint glow should be seen through the window in the LED block. Return the pulse width to 10 μs. Connect the PMT to the output cables and HT input and mount on the stand, with the end of the tube 50 cm from the LED source. Testing Set up a data table with 4 columns: Voltage, I-dark (0V), (I-dark (testV), and I-light (Voltage in kV, I in nA). Record the 0V current on the picoammeter (PAM). (The picoammeter’s baseline may shift over time.) Turn on the HV and raise the voltage to 1 kV. Record the test voltage dark current (Take aprrox. 10 sec to try and determine the mean value, the PAM reading will fluctuate considerably.) Turn on the LED by switching the polarity back to +. If PAM read OL switch back to – and seek problem. Record I-light. Switch off the LED and repeat measurements (I-dark (0V), I-dark (tV), I-light) up to 1.8 kV). I-dark (0V) can be recorded by disconnecting the BNC connector from the power supply to the PMT. If necessary, adjust the PAM range to 2 μa, but never allow the current to go above 1 μa. Replace PMT and repeat.

The Hamamatsu tubes are considerably more sensitive than the Quarknet and Thorn tubes. Consequently, the PMTs used in the detector will be Hamamatsu tubes. At operating voltage (1.4 kV) the mean current was 60.4 nA and the mean light current/dark current ratio was We decided to use an operating voltage of 1400 volts because beyond that there is no major increase of SNR, so there is no significant gain in sensitivity. Excepting a few bad tubes, most of the Thorn tubes seemed to be of similar sensitivity with an acceptable SNR. At 1.5 kV the mean current was 26.2 nA and a 17.4 light current/dark current ratio. The Quarknet tubes were found to be noisy overall. They seemed to have the highest sensitivity and SNR at around 1.4kV, but often the dark current exceeded the light current. The mean dark current is nA higher than the mean light current. As result of the overall higher SNR they would not be the first choice for testing with the large scintillators.

Testing Setup: Pictured are, from left to right, the dark box, the picoammeter, the pulse generator, the High Voltage source, and the oscilloscope.

PMT Mount in the dark box (50 cm from LED block) Acrylic Block with Embedded LED and Slit Window Pulse width graph demonstrating the linear relationship between the LED pulse width and the output current.

Individual Thorn PMT: current data and the net light current/net dark current ratio. A higher ratio represents low noise for the tube.

Thorn PMTs: acceptable sensitivity and SNR. The mean light current up to 1.5 kV is 7.9 nA.

Quarknet PMTs: signal to noise ratio was exceptionally poor when tested with green LED. The mean up to 1.5 kV was 8.1 nA.

Hamamatsu PMTs: highest sensitivity and best SNR of all tubes. The mean light current up to 1.5 kV was 37.2 nA.