Scintillator-based Hadron Calorimetry for the ILC/SiD International Linear Collider Workshops Snowmass, 14-27 Aug, 2005 Dhiman Chakraborty.

Slides:



Advertisements
Similar presentations
Scintillator Tile Hadronic Calorimeter Prototype (analog or semidigital) M.Danilov ITEP(Moscow) CALICE Collaboration LCWS04, Paris.
Advertisements

2 Introduction   MiniCal test-beam studies started at the beginning of March (till March 6 we only had 17 APD’s, then 33 APD’s)   A few days were.
1 Construction of the hadronic calorimeter prototype for ILC (CALICE collaboration) or experience with Geiger mode operating multipixel photodiodes (SiPM)
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan 1.Introduction 2.Recent.
Fiberless Coupled Tiles for a High Granularity Scintillator-SiPM Calorimeter Rick Salcido Northern Illinois University November 14, 2009 Prairie Section.
Some early attempts at PFA Dhiman Chakraborty. LCWS05 Some early attempts at PFA Dhiman Chakraborty2 Introduction Primarily interested in exploring the.
A preliminary analysis of the CALICE test beam data Dhiman Chakraborty, NIU for the CALICE Collaboration LCWS07, Hamburg, Germany May 29 - June 3, 2007.
Jerry Blazey NIU/NICADD Towards A Scintillator (Semi)- Digital Hadron Calorimeter: Progress at NIU/NICADD Jerry Blazey Northern Illinois University.
Scintillator based muon upgrade / BELLE Super B Factory Workshop In Hawaii Jan 2004, Honolulu, Hawaii 1.Scintillator strip option 2.Geiger photodiodes.
Jerry Blazey NIU/NICADD Towards A Scintillating (Semi)- Digital Hadron Calorimeter: Progress at NIU/NICADD Jerry Blazey Northern Illinois University.
CALICE Toward a scintillator-based Digital Hadron Calorimeter and Tail-catcher for the LC Manuel I. Martin Northern Illinois University XI International.
Towards a Digital Hadron Calorimeter Vishnu V. Zutshi for NIU/NICADD Group.
A Digital Hadron Calorimeter ? Vishnu V. Zutshi NIU/NICADD.
Calibration issues for the CALICE 1m 3 AHCAL LCWS11 - International Workshop on Future Linear Colliders Granada, Spain 2011/9/28 Jaroslav Zalesak Institute.
1 Tianchi Zhao University of Washington Concept of an Active Absorber Calorimeter A Summary of LCRD 2006 Proposal A Calorimeter Based on Scintillator and.
Selection of Silicon Photomultipliers for ILC Analogue Hadron Calorimeter Prototype Lay-out * ILC Hadron Calorimeter prototype with SiPM readout * Selection.
Calorimetry: a new design 2004/Sep/15 K. Kawagoe / Kobe-U.
CALICE Meeting DESY ITEP&MEPhI status report on tile production and R&D activities Michael Danilov ITEP.
Calibration UV LED system for CALICE scintillator based Tile Hadron Calorimeter Ivo Polák on behalf of the CALICE Collaboration Institute of Physics of.
SiPM: Development and Applications
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
The Scintillator ECAL Beam Test at FNAL Adil Khan International Linear Collider Workshop 2010 LCWS10 & ILC10, Beijing, China CALICE Scintillator ECAL group.
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
Montpellier, November 15, 2003 J. Cvach, TileHCAL and APD readout1 TileHCAL- fibre readout by APD APDs and preamplifiers Energy scan with DESY beam –Energy.
Scintillator tile-SiPM system development for CALICE Engineering AHCAL Prototype Michael Danilov, ITEP & CALICE LCWS10 Beijing March 2010 Outline New scintillator.
Study of the Multi-Pixel Photon Counter for ILC calorimeter Satoru Uozumi (Kobe University) Atami Introduction of ILC and MPPC The MPPC performance.
Tungsten as HCal-material for a LC at multi-TeV energies CALICE AHCAL Meeting, DESY 17 July 2009 Christian Grefe for the Linear Collider Detector Group.
Scintillator ECAL for ILC for Calorimeter Review DESY May2007 Tohru Takeshita (CALICE-Shinshu) Idea implementation current status future mile stones.
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group (KNU, Kobe, Niigata, Shinshu, ICEPP.
DESY Beam Test of a EM Calorimeter Prototype with Extruded Scintillator Strips DongHee Kim Kyungpook National University Daegu, South Korea.
ILC Calorimetry Test Beam Status Lei Xia ANL HEP.
FSC Status and Plans Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA Russia workshop, ITEP 27 April 2010.
Multipixel Geiger mode photo-sensors (MRS APD’s) Yury Kudenko ISS meeting, KEK, 25 January 2006 INR, Moscow.
Prospects to Use Silicon Photomultipliers for the Astroparticle Physics Experiments EUSO and MAGIC A. Nepomuk Otte Max-Planck-Institut für Physik München.
Scintillator tile – SiPM development at ITEP Michael Danilov, ITEP CALICE Meeting, Casablanca, 23 Sep 2010.
V. Korbel, DESY1 Progress Report on the TESLA Tile HCAL Option To be filled soon.
SiPM for CBM Michael Danilov ITEP(Moscow) Muon Detector and/or Preshower CBM Meeting ITEP
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
(s)T3B Update – Calibration and Temperature Corrections AHCAL meeting– December 13 th 2011 – Hamburg Christian Soldner Max-Planck-Institute for Physics.
LC Muon Detector Development Overview Hardware R&D Goals Hardware Configuration Design Issues Procurement, Engineering, Manpower Additional Development.
Calibration issues for the CALICE 1m3 AHCAL ALCPG11 - Linear Collider Workshop of the Americas Eugene, Oregon, USA 2011/3/22 Jaroslav Zalesak Institute.
Imaging Hadron Calorimeters for Future Lepton Colliders José Repond Argonne National Laboratory 13 th Vienna Conference on Instrumentation Vienna University.
Performance of Scintillator-Strip Electromagnetic Calorimeter for the ILC experiment Satoru Uozumi (Kobe University) for the CALICE collaboration Mar 12.
Jet Energy Measurement at ILC Separation of jet particles in the calorimeter is required for the PFA  Fine granular calorimeter is necessary. Particle.
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
CALICE, CERN June 29, 2004J. Zálešák, APDs for tileHCAL1 APDs for tileHCAL MiniCal studies with APDs in e-test beam J. Zálešák, Prague with different preamplifiers.
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan for the GLD Calorimeter.
Study and Development of the Multi-Pixel Photon Counter for the GLD Calorimeter Satoru Uozumi (Shinshu, Japan) on behalf of the GLD Calorimeter Group Oct-9.
Energy Reconstruction in the CALICE Fe-AHCal in Analog and Digital Mode Fe-AHCal testbeam CERN 2007 Coralie Neubüser CALICE Collaboration meeting Argonne,
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Performance of 1600-pixel MPPC for the GLD Calorimeter Readout Jan. 30(Tue.) Korea-Japan Joint Shinshu Univ. Takashi Maeda ( Univ. of Tsukuba)
CEPC ScECAL Optimization for the 3th CEPC Physics Software Meeting
Roman Mizuk (ITEP, Moscow)
Scintillation Detectors in High Energy Physics
SiD Calorimeter R&D Collaboration
State-of-the-art in Hadronic Calorimetry for the Lepton Collider
Vishnu V. Zutshi For the NICADD team.
Towards a Scintillator-based (semi)Digital HCal
ITEP&MEPhI status report on tile production and R&D activities
Study of a Scintillating Digital Hadron Calorimeter Prototype
Argonne National Laboratory
Vishnu V. Zutshi for NIU/NICADD
N vs. E 0.25mip threshold roughcut for SLAC 2/24/2019.
Scintillator HCal Prototype
LC Calorimeter Testbeam Requirements
The MPPC Study for the GLD Calorimeter Readout
LC Muon Detector Development Overview
Towards a Scintillator-based (semi)Digital HCal
Presentation transcript:

Scintillator-based Hadron Calorimetry for the ILC/SiD International Linear Collider Workshops Snowmass, Aug, 2005 Dhiman Chakraborty

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 2 Why (not) scintillators? Tested and true, well understood & optimized, New developments in cell fabrication & photo- detection help meet ILC/PFA demands –Fine segmentation at a reasonable cost –Photodetection and digitization inside detector ⇒min. signal loss/distortion, superior hermeticity Can operate in both analog and digital modes –Measures energy, unlike RPC & GEM that only offer hit-counting (“tracking” or “imaging” calorimetry) –Remains a viable option if digital PFA fails to deliver.

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 3 Design Considerations: PFA Need ≲10 cm 2 lateral segmentation. At least ~35 layers and ~4λ must fit in ~1 m along R. –Min. R in driven by tracker performance. –Max. R out limited by magnet and material costs. –Min. absorber fraction limited by the need for shower containment. ⇒2 cm thick absorber layers if SS (less if W). ⇒ cm sensitive layers must respond to MIPs with good efficiency and low noise. (cont’d...)

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 4 Design Considerations: PFA (…cont’d) Good lateral containment of showers is important for minimizing the confusion term. W absorber in ECal ⇒ e/  compensation is not built in ⇒ must be achieved in software ⇒ particle id (inside calorimeter by shower shape?) may be important.

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 5 Design Considerations: Others The technology must be –Reliable, –Mechanically sound, –Operable inside strong (~4.5T) magnetic field, –Capable of 15+ years of running, –Tolerant to ~5  fluctuations in T, P, humidity, purity of gas (if any). Monitoring will be necessary if response depends strongly on any of these, –Suited for mass-production and assembly of millions of cells in ~40 layers, (cont’d…)

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 6 Design Considerations: Others The technology must be (…cont’d) –Allow hermetic construction (minimum cracks/gaps) –Safe (HV, gas, …), –Compatible with other subsystems (MDI?), –Amenable to periodic calibration, –Able to handle the rates (deadtime < 0.1 s?) –Cost-effective (including construction, electronics, operation).

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 7 Hardware tests Cells made of cast (Bicron) and extruded scintillators (NICADD/FNAL) have been extensively tested with many variations of –Shape (hexagonal, square), –Size, thickness –Surface treatment (polishing, coating), –Fibers (manufacturer, diameter, end-treatment) –Grooves (  shaped, straight) –Photodetectors (PMT, APD, SiPM, MRS)

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 8 Hardware tests Different cell and groove shapes with extruded and cast scintillators

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 9 Hardware Prototypes (DESY “MiniCal”) DESY 6 GeV e beam scintillator tiles (5x5cm) Readout with Silicon PMs on tile, APDs or PMTs via fibres 2 cm steel 0.5 cm active DES Y, Hamburg U, ITEP, LPI, MEPHI, Prague

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 10 DESY “MiniCal” Test Beam results Resolution as good as with PM or APD* Non-linearity can be corrected (at tile level) –Does not deteriorate resolution –Need to observe single photon signals for calibration Well understood in MC Stability not yet challenged NIM A (2005)

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 11 Choosing the Optimum Threshold 0.25 MIP threshold: efficient, quiet

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 12 Miscellaneous Measurements Response ratios between types, glues, fibers,… Scintillator type: extruded/cast ≈ 0.7 Optical glue: EJ500/BC600 ≈ 1.0 Fiber: Y11/BCF92 ≈ 3.2 –Y11 = 1 mm round Kuraray, –BCF92 = 0.8 mm square Bicron Extruded/cast (cost) ≈ 0.05

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 13 Optimum parameters Shape: Hexagonal or Square Thickness: 5 mm Lateral area: cm 2 Groove: straight Fiber: Kuraray 1 mm round (or similar) Fiber glued, surface painted Scintillator type: Extruded But a bigger question is the photodetector: PMTs are costly, bulky, won’t operate in B field. We have been investigating APDs, MRS, Si-PM… Based on what we have learnt so far

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 14 The Metal/Resistor/ Semiconductor Photodiode (MRS) From the Center of Perspective Technologies & Apparatus (CPTA), Multi-pixel APDs with every pixel operating in the limited Geiger multiplication mode & sensitive to single photon, pixels on 1 mm x 1 mm sensor, Avalanche quenching achieved by resistive layer on sensor, Detective QE of up to 25% at 500 nm, Good linearity (within 5% up to 2200 photons) Immune to magnetic field, Radiation-tolerant.

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 15 Study of MRS/SiPM Determination of Working point: –bias voltage, –threshold, –temperature Linearity of response Stress tests: magnetic field, exposure to radiation. Tests with scintillator using cosmic rays and radioactive source.

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 16 Metal Resistive Semiconductors (MRS) Typical pulseheight spectrum Poduced by the Center of Perspective Technologies & Apparatus (CPTA) B. Dolgoshein

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 17 SiPM Summary We have conducted a set of measurements to illustrate the potential use of Si photodetectors in High Energy Collider experiments in general, and for hadron calorimetry at the ILC in particular. Good MIP sensitivity, strong signal (gain ~O(10 6 )), Fast: Rise time ≈ 8 ns, Fall time < 50 ns, FWHM ≈ 12 ns (w/ amp) Very compact, simple operation (HV, T, B,…), Each sensor requires determination of optimal working point, Noise is dominated by single photoelectron: a threshold to reject 1 PE reduces the noise by a factor of ~2500, The devices operate satisfactorily at room temperature (~22 ˚C). Cooling reduces noise and improves gain, Not affected by magnetic field (tested in up to 4.4 T + quench), No deterioration of performance from 1 Mrad of  irradiation.

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 18 SiPM prospects on the horizon Bigger SiPMs are under development –3mm x 3mm made, but require cooling to -40 C –5mm x 5mm thought possible –cost increase: insignificant (CPTA), linear (H’matsu)? 5mm x 5mm may help us eliminate fibers –put the SiPM directly on the cells –wavelength matching by n-on-p (sensitive to blue scint. light) or WLS film –hugely simplifies assembly Better uniformity across sample with purer Si.

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 19 Simulation Studies Steel 20mm Polystyrene 5mm Scint HCal Gas Geom1 Steel 20mm Gas 5mm Gas Geom2 G10 Glass 1mm Gas 1mm Geometries considered

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 20  + energy resolution as function of energy for different (linear) cell sizes

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 21 Compensation Cell counting has its own version of the compensation problem (in scintillators). With multiple thresholds this can be overcome by weighting cells differently (according to the thresholds they passed). In MC, 3 thresholds seem to be adequate.

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 22  + energy resolution vs. energy Two-bit (“semi-digital”) rendition offers better resolution than analog

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 23 Nhit vs. fraction of  + E in cells with E>10 MIP: Gas vs. scintillator 2-bit readout affords significant resolution improvement over 1-bit for scintillator, but not for gas

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 24  + energy resolution vs. energy Multiple thresholds not used

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 25 Non-linearity Nhit/GeV varies with energy. This will introduce additional pressure on the “constant” term. For scintillator, the non-linearity can be effectively removed by “semi-digital” treatment.

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 26  ± angular width: density weighted

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 27 Simulation Summary Large parameter space in the nbit- segmentation-medium plane for hadron calorimetry. Optimization through cost- benefit analysis? Scintillator and Gas-based ‘digital’ HCals behave differently. Need to simulate detector effects (noise, x-talk, non-linearities, etc.) Need verification in test-beam data. More studies underway.

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 28 TB: Scint HCal layer assembly

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 29 Summary Simulations indicate (semi-) digital approach to be competitive with analog calorimetry Prototypes indicate scintillator offers sufficient sensitivity (light x efficiency) & uniformity. Now optimizing materials & construction to minimize cost with required sensitivity. SiPM and MRS photodetectors look very promising. Preparations for Test Beam (Analog tile HCal and Strip tail-catcher/muon tracker) are in full swing. All-in-all scint looks like a competitive option. We are moving toward the next prototype.

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 30 Thank you! For further details, see talks given by DC at The LC study group mtg on 26 May ’05, The Beaune Photodetection Conference, June ’05. Links at

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 31 Backup slides

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 32 Working point determination with LED The MRS is to able to separate single photoelectrons Different response under identical setup ⇒ working point must be determined for each channel individually Channel 2 Channel 4 Channel 5

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 33 Cosmic MIP detection with SiPM Comparable to PMT

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 34 Noise Rate vs. Bias Voltage & Threshold The right end of the plateau region in the Figure on left is optimal for our purpose. For thresholds in the range of 80±10 mV and bias voltage in 50.0±0.5 V, the dark noise is well under control.

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 35 Signal & Noise Amplitudes vs. Bias Voltage For this particular device S/N peaks at V bias ≈ 52 V Sharp peaking in S/N⇒ working point must be found for each piece.

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 36 Temperature Dependence Bias = 51.3 mV, threshold = 80 mV Loss in signal amplitude with increase in T ≈ 3.5%/˚C

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 37 Fiber Positioning on MRS Optimal fiber-sensor mating is crucial.

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 38 Linearity of Response Since the response of an individual pixel is not proportional to n , (unless it has had time in between to recover), non-linearity is expected when the detector receives a large number of photons. Deviation reaches 5% (10%) at n  ≈ 2200 (3000) or, n PE ≈ 550 (750). One MIP ≈17 PE ⇒ up to 32 MIPs can be measured within 5% linearity.

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 39 Stress Tests: Effect of Mag. field No significant effect of fields up to 4.4 T and quenching at 4.5T 

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 40 Stress Tests: Effect of Irradiation No detectable damage from 1 Mrad of 

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 41 Hit timing

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 42 Hit timing (contd.)

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 43 Hit timing (contd.)

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 44 Hit timing (contd.) Scintillator RPC Same Z → jj event at pole Same cell size (1cm x 1 cm) Same threshold of 0.25 MIP

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 45 Hit timing (contd.) ECal hits in the same events as on the last slide

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 46 Time of flight t (ns) dN hit /dt

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 47 Time-of-flight dependence of resolution 100ns/5  s

ILCW2005, SnowmassScintillator-based HCal for ILC Dhiman Chakraborty 48 Avalanche Photo-Diodes