Development of a mover having one nanometer precision and 4mm moving range Y. Morita, S. Yamashita ICEPP, University of Tokyo Y. Higashi, M. Masuzawa,

Slides:



Advertisements
Similar presentations
Industrial Electrical Engineering and Automation Actuators Linear movement and vibration.
Advertisements

ATF2 Interaction Point Beam Size Monitor (Shintake Monitor) Status T. Yamanaka, M. Oroku, Y. Yamaguchi, S. Komamiya ( Univ. of Tokyo ), T. Suehara, Y.
Vibration issues for SuperKEKB M. Masuzawa, R. Sugahara and H. Yamaoka (KEK) Vibration issues for SuperKEKB (IWAA2010)
1/8 T. Kume, Y. Honda, and T. Tauchi High Energy Accelerator Research Organization (KEK) T. Suehara, H. Yoda, M. Oroku, T. Yamanaka and Y. Kamiya The univ.
Flexures for Optics. Outline Brief overviews of micro flexures Focus on macro flexures in this tutorial Beam bending Symmetry -> precision Degree of freedom.
ILC Cryomodule Earthquake response simulation H. Hayano, H. Nakai, Y. Yamamoto LCWS13 AWG7-SCRF.
April 27th, 2006 Paola Puppo – INFN Roma ILIAS Cryogenic payloads and cooling systems (towards a third generation interferometer) part II: the Vibration.
Wed 15 Jul 2009 ATF2 weekly meeting Oxford MONALISA 1 MONALISA at ATF2 First installation report 15 July 09.
Global Design Effort Detector concept # Plenary introductory talk IRENG07 Name September 17, 2007.
G M Advanced R&D1 Seismic Isolation Retrofit Plan for the LIGO Livingston Observatory Dennis Coyne 29 Nov 2001.
Sta bilization of the F inal F ocus : Stabilization with Nano-Meter Precision.
StaFF: Motion Stabilization with Nano-Meter Precision Proposed experiment conducted within framework of StaFF (Stabilization of Final Focus for ILC). Funded.
Linac Coherent Light Source Stanford Synchrotron Radiation Laboratory Stanford Linear Accelerator Center LCLS Undulator Physics.
Chapter 14 Oscillations Chapter Opener. Caption: An object attached to a coil spring can exhibit oscillatory motion. Many kinds of oscillatory motion are.
Integration and Differentiation of Time Histories
IPBPM piezo-mover system and plans for in situ monitoring of calibration and stability Current status and plan for ATF2 Philip Bambade Laboratoire de l’Accélérateur.
-brief report of October runs and some inputs for the Nov/Dec planning – Nobuhiro Terunuma, KEK, ATF ATF session on LCWS13, Tokyo Univ., Nov. 13, 2013.
Vibration measurements on the final doublets and the Shintake Monitor Benoît BOLZON7th ATF2 project meeting, 16/12/08.
Yuji Otake, Akito Araya and Kazuo Hidano
Alignment and Beam Stability
ALIGNMENT DESIGN AND STATUS OF TAIWAN PHOTON SOURCE WEI-YANG LAI October,
David Urner, Oxford University, RHUL – June StaFF Stabilization of Final Focus Motion Stabilization with Nano-Meter Precision David Urner Paul Coe.
Supports and Movers for ATF2 Magnets R. Sugahara KEK France and Japan Collaboration Meeting Feb , 2006.
Y. Ohnishi / KEK KEKB-LER for ILC Damping Ring Study Simulation of low emittance lattice includes machine errors and optics corrections. Y. Ohnishi / KEK.
Vibration Measurement on the Shintake Monitor and Final Doublet Takashi Yamanaka (Univ. of Tokyo) Benoît Bolzon (LAPP) ATF2 weekly meeting 26 November,
CLIC MDI stabilization update A.Jeremie G.Balik, B.Bolzon, L.Brunetti, G.Deleglise A.Badel, B.Caron, R.Lebreton, J.Lottin Together with colleagues from.
A NON-TRADITIONAL HIGH PERFORMANCE BROAD-BAND SEISMOMETER PMD/eentec, USA
Performance Test of Laser Trackers of FARO Ryuhei Sugahara, Mika Masuzawa and Yasunobu Ohsawa KEK, High Energy Accelerator Research Organization Oho, Tsukuba,
1/10 Tatsuya KUME Mechanical Engineering Center, High Energy Accelerator Research Organization (KEK) ATF2-IN2P3-KEK kick-off meeting (Oct. 10, 2006) Phase.
Experience on Vibration Isolation System R. Sugahara KEK and Mika Masuzawa (1), Hiroshi Yamaoka (1), Yasuo Higashi (1) Yuichi Morita (2) and Satoru Yamashita.
NLC - The Next Linear Collider Project SLAC tunnel motion and analysis Andrei Seryi SLAC Originally given at The 22nd Advanced ICFA Beam Dynamics Workshop.
ILC FAST TUNER R&D PROGRAM at FNAL Status Report CC2 Piezo Test Preliminary Results Ruben Carcagno (on behalf of the FNAL FAST TUNER Working Group) 4/5/06.
1 SiD Push-pull Plans Marco Oriunno, SLAC International Workshop on Linear Colliders 2010 Geneva, October 2010 M.Oriunno, IWLC10 – Geneva, Oct.2010.
Cavity support scheme options Thomas Jones 1. Introduction Both cavities will be supported by the fundamental power coupler and a number of blade flexures.
Short range alignment strategy in CLEX and first results CLIC Workshop January 2015 on behalf of : Hélène Mainaud-Durand, Mateusz Sosin Mathieu.
Production and Installation Policy of IP-BPM ATF2 Project Meeting, 2006/12/18 Y. Honda, Y. Inoue, T. Hino, T. Nakamura.
How high frequency we care if we need the stabilization of 1nm level?
LASER FRAME: Straightness monitor (Tentative results of resolution test) Third Mini-Workshop on Nano Project at ATF May 30-31,2005 KEK Nano BPM Group Y.Higashi,
IP BPM’s for ATF2 Vladimir Vogel KEK May30, 2005 Third Mini-Workshop on Nano Project at ATF.
Main beam Quad Stabilisation: Status of the stabilisation test program at CERN CLIC-stabilization day S. Janssens Contribution to slides by:
Current Status of LASER FRAME for KEK-Nano BPM (Tentative results of resolution test) Second Mini-Workshop on Nano Project at ATF December 11-12, 2004.
Taikan SUEHARA, ATF2 meeting, KEK, 2006/11/22 Status of fringe stabilization of Shintake-monitor Taikan SUEHARA The University of Tokyo.
FD Movers and Alignment Methods Superconducting Magnet Division, BNL IRENG07 Workshop: September 19, 2007.
NUMI Flexible Joint/Floating Clamp WBS Power Supply System Level 3 Manager Nancy Grossman FNAL July 10, 2001.
Summary of Tuning, Corrections, and Commissioning ( Short summary of ATF2 meeting at SLAC in March 2007 ) and Hardware Issues for beam Tuning Toshiyuki.
Taikan SUEHARA et al., LCWS2007 & DESY, 2007/06/01 R&D Status of ATF2 IP Beam Size Monitor (Shintake Monitor) Taikan SUEHARA, H.Yoda, M.Oroku,
1 KEK Hiroshi Yamaoka Vibration analysis of the ILD QD0-support system Oct, 2 nd '09 KEK H. Yamaoka - Results of Vibration analysis - Coherency measurement.
ATF2: final doublet support Andrea JEREMIE B.Bolzon, N.Geffroy, G.Gaillard, J.P.Baud, F.Peltier With constant interaction with colleagues from KEK, SLAC.
NLC - The Next Linear Collider Project Keeping Nanometer Beams Colliding Vibration Stabilization of the Final Doublet Tom Himel SLAC NLC MAC review October.
QD0 stabilisation in CLIC CDR A.Jeremie with LAViSta team.
SPM Users Basic Training August 2010 Lecture VIII – AC Imaging Modes: ACAFM and MAC Imaging methods using oscillating cantilevers.
Design for a New Optical Table of the Shintake Monitor Takashi Yamanaka The University of Tokyo ATF2 weekly meeting 2007/9/26.
Progress of Shintake Monitor (ATF2 IP-BSM) ATF2 weekly meeting 2008/9/3 Takashi Yamanaka The University of Tokyo.
Accuracy of the orbit measurement by KEKB BPM system for the study of ILC damping ring H. Fukuma (KEK) Requirement for the accuracy of BPM data.
Moving Wire, Pulsed Wire and Long Coil Measurements on the SSRL Beam Line 5 EPU Scott Anderson SLAC Magnetic Measurements.
HLS Installation at KEKB Main Ring after the Great East Japan Earthquake Takashi Kawamoto, Mika Masuzawa, Ryuhei Sugahara High Energy Accelerator Research.
Tutorial On Fiducialization Of Accelerator Magnets And Undulators
Summary FD Support System
Vibration issues at Linear Colliders:
CLIC magnets precise positioning
Period of Simple Harmonic Motion
For Discussion Possible Beam Dynamics Issues in ILC downstream of Damping Ring LCWS2015 K. Kubo.
Vibration studies for the QD0-support system
By Arsalan Jamialahmadi
Sonde Specifications Piezoelectric P wave transducer
الفصل 1: الحركة الدورانية Rotational Motion
1/10 prototype support tube
IP configuration session
The MPPC Study for the GLD Calorimeter Readout
Presentation transcript:

Development of a mover having one nanometer precision and 4mm moving range Y. Morita, S. Yamashita ICEPP, University of Tokyo Y. Higashi, M. Masuzawa, R. Sugahara, H. Yamaoka KEK IWAA’06, SLAC, Sep. 28, 2006

ILC (International Linear Collider) Next generation large linear accelerator Next generation large linear accelerator The beam size at the interaction region is The beam size at the interaction region is several nm several nm

Motivation for the mover The beam size is several nm require 1nm precision alignment of components

Purpose of the mover Fine tuning for the position of ILC components Fine tuning for the position of ILC components (1nm precision) (1nm precision) Wide range adjustment (4.5mm) Wide range adjustment (4.5mm)

Specification Beam direction V Y X

Specification Mass: about 350kg Material: SUS303 The load limit: about 700kg Piezoelectric mover Cam mover This mover is for fine tuning 6 piezoelectric transducers X, Y, V and  x,  y,  v directions Moving range: 0.4  m Moving precision: 1nm This mover is for wide range adjustment 3 motors X, V and  y directions Moving range: 4.5mm Moving precision: 0.1  m

Cam mover 3 motors Shafts with offsets motor X V Top table moves in X, V and  y directions Rotation axis Center of the thick shaft Connecting arm 1.6mm offset

Piezoelectric mover 3 piezoelectric transducers for vertical motion 3 piezoelectric transducers for horizontal motion The table moves X, Y, V and  x,  y,  v directions The cross section along the line W springs

Cam mover

Calculation of the cam mover motion 4.5mm  1=0,  2=  3  2 and  3 are rotated.  1=  3=0  2 is rotated. 2mm  x 1  r · cos  1 +D  2  y 1  r · sin  1  h  2  l 2 (x 2  r · cos  2  D  2  y 2  r · sin  2  h  2  l 2  x 2  r · cos  3  D  d  2  y 2  r · sin  3  h  2  l 2  x 2  x 1  2  y 2  y 1  2  4 · D 2

Comparison between calculation and measurement Solid line: calculation result “ + ” marks: measurement Pulses to the motors Slope (rad) Pulses to the motors Slope (rad) Slope of the table is compared  1=0,  2=  3  2 and  3 are rotated.  1=  3=0  2 is rotated.

Piezoelectric mover

Noise of the capacitive sensor Sampling rate is 2.54kHz Sampling rate is 2.54kHz For 10 seconds For 10 seconds Standard deviation is 2.4nm Standard deviation is 2.4nm A capacitive sensor is used to examine the property of the piezoelectric transducers Capacitive sensor

Piezo motion Piezoelectric transducer Capacitance type displacement sensor Voltage on piezo (V) Movement of table (  m) A piezoelectric transducer has a hysteresis Moving range is about 0.4  m

Piezo resolution and response speed 12nm Resolution 1 or 2nm can be expected Time (sec) Movement of table (  m) Response speed of the piezoelectric transducer is 56  m/sec

Vibration cancellation and natural vibration of the mover stoppers Up to 30Hz vibration cancellation system will be developed Natural vibration of the mover is 45Hz near Stoppers are installed to shift the natural vibration frequency

Vibration of the table (PSD) Vertical directionX direction Vertical direction Red: on the table Blue: on the floor With stoppers Without stoppers 30, 50, 60Hz 65Hz 50, 60Hz over 100Hz

Summary Moving range 4.5mm  m Moving range 4.5mm  m 12nm step was clearly observed 12nm step was clearly observed  1 or 2nm resolution can be expected  1 or 2nm resolution can be expected Response speed of the piezo is 56  m/sec Response speed of the piezo is 56  m/sec Natural frequency of the mover is 65Hz or higher with stoppers Natural frequency of the mover is 65Hz or higher with stoppers

Future prospect The response speed of the piezoelectric transducer is high (56  m/sec) 2. Develop the vibration cancellation system up to about 30Hz (In the region>30Hz, amplitude<1nm) feedback or feedforward Michelson-Morley or Fabry-Perot laser interferometer 1. Measure again with more sensitive and stable sensors

The end of the slides

Specification Range Resolution Speed Rough movers ± 1.5 mm 0.1  m > 0.1 mm/sec Precision movers ± 0.2  m 1 nm > 0.5  m/sec Need 5 directions (X, Y,  X,  Y,  Z ) Max. weight of load is 2 tons Size of table (to install QD0) 600        H - Two stage mover Rough mover stage --> Cam movers Precision mover stage --> Piezo movers

X Y Z Y

Horizontal piezo actuator Vertical piezo actuator Beams

According to ANSYS calculation, rough mover stage is weak! --> Stopper is installed w/o stoppers With stoppers Primary mode 45.1 Hz Hz Secondary mode Third Stoppers Total system -->