K. Oishi, K. Kosako and T. Nakamura Institute of Technology, Shimizu Corporation, Japan id=17 SATIF-10.

Slides:



Advertisements
Similar presentations
X Rays Medical Physics Notes.
Advertisements

New results of radiation environment investigation by Liulin-5 experiment in the human phantom aboard the International Space Station.
Stefan Roesler SC-RP/CERN on behalf of the CERN-SLAC RP Collaboration
Beam-plug and shielding studies related to HCAL and M2 Robert Paluch, Burkhard Schmidt November 25,
RAD309 Patient Dose.
Particle interactions and detectors
RHESSI/GOES Observations of the Non-flaring Sun from 2002 to J. McTiernan SSL/UCB.
Radioactivity – review of laboratory results For presentation on May 2, 2008 by Dr. Brian Davies, WIU Physics Dept.
Properties of Multilayer Optics An Investigation of Methods of Polarization Analysis for the ICS Experiment at UCLA 8/4/04 Oliver Williams.
Radioactivity – inverse square law, absorption, and rates presentation for Apr. 30, 2008 by Dr. Brian Davies, WIU Physics Dept.
Monte Carlo model and spectral measurements of a computed tomography x-ray tube Magdalena Bazalova Frank Verhaegen.
Interaction of Radiation with Matter - 4
1 Radiation Environment at Final Optics of HAPL Mohamed Sawan Fusion Technology Institute University of Wisconsin, Madison, WI HAPL GIMM Conference Call.
At the position d max of maximum energy loss of radiation, the number of secondary ionizations products peaks which in turn maximizes the dose at that.
Beam Therapy Equipment 3 Patient Treatment and Accessories.
Radiation therapy is based on the exposure of malign tumor cells to significant but well localized doses of radiation to destroy the tumor cells. The.
Dose Distribution and Scatter Analysis
ALPHA Project Safety Assessment Document Vladimir Anferov.
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
HABIS X-RAY PRODUCTION AND EXPOSURE FACTORS X-RAY PRODUCTION AND EXPOSURE FACTORS PREPARED BY PREPARED BY Dr fahad albadr radiology chairman radiology.
Radiation Protection in Radiotherapy
Preliminarily results of Monte Carlo study of neutron beam production at iThemba LABS University of the western cape and iThemba LABS Energy Postgraduate.
SHMS Optics and Background Studies Tanja Horn Hall C Summer Meeting 5 August 2008.
FUNCTIONAL SPECIFICATION Dorothea Pfeiffer Dennis Haasler GIF++ User Meeting
Nuclear Instrumentation Laboratory Federal University of Rio de Janeiro -BRAZIL X-ray Fluorescence and X-ray Transmission Microtomography Imaging System.
First AWAKE dump calculations Helmut Vincke. Beam on dump Muon axis inside and outside CERN Distances: Beam impact point to end of West hall: ~300 m Beam.
COMPANY CONFIDENTIAL Mike Dalterio…Bio Michael Dalterio, Experimental Physicist Mr. Dalterio has over 20 years experience as a physicist in start-up companies.
Table of Contents  General Description  Concept of RX Vessel and Location of Defect  Radiation Dose Control  Repair Schedule of Bottom Header Defected.
Araki F. Ikegami T. and Ishidoya T.
Systematic studies of neutrons produced in the Pb/U assembly irradiated by relativistic protons and deuterons. Vladimír Wagner Nuclear physics institute.
Integrated Radiation Measurement and Radiation Protection of BES Ⅲ Zhang Qingjiang, Wu protection group, accelerator center, IHEP,
Managed by UT-Battelle for the Department of Energy Residual Does Rate Analyses for the SNS Accelerator Facility I. Popova, J. Galambos HB2008 August 25-29,
Cosmic rays at sea level. There is in nearby interstellar space a flux of particles—mostly protons and atomic nuclei— travelling at almost the speed of.
October 2005 Qweak Collaboration Meeting Detailed Design of Shield House and Collimators wrt Backgrounds Yongguang Liang Just getting started – will probably.
Authorization and Inspection of Cyclotron Facilities Design, Layout and Shielding.
Experimental Studies of Spatial Distributions of Neutrons Produced by Set-ups with Thick Lead Target Irradiated by Relativistic Protons Vladimír Wagner.
Shielding Measurements For A Proton Therapy Facility S. Avery, K. P. Risolo, M. Bartels, C. Ainsley, J McDonough, R. L. Maughan University of Pennsylvania.
Determining Radiation Intensity
First radiological estimates for the HIRADMAT project H. Vincke and N. Conan 1.
Recent Studies on ILC BDS and MERIT S. Striganov APD meeting, January 24.
Introduction to Radiation Therapy
1 Neutron Effective Dose calculation behind Concrete Shielding of Charge Particle Accelerators with Energy up to 100 MeV V. E Aleinikov, L. G. Beskrovnaja,
Radiation Protection in J-PARC neutrino beam line Sep Yuichi Oyama (KEK) for T2K neutrino beam line construction group Happy birthday.
Gamma Shielding Calculations
Mixed field irradiation -- Who answered ?  In total 36 forms filled / 34 persons answered: 38% 62% CERN: mainly LHC related topics CERF: beside LHC topics.
Interaction of x-ray photons (and gamma ray photons) with matter.
24 th ICNTS Design and test of an albedo personal neutron dosemeter based on PADC detectors R. Bedogni a, A. Esposito a, G. Gualdrini b, R. Mishra c, S.
ArgonneResult_ ppt1 Comparison of data and simulation of Argonne Beam Test July 10, 2004 Tsunefumi Mizuno
The Science of Radiation Shielding An introduction to the science of radiation shielding Steven Johnston Ph.D. AIA Chicago Healthcare Knowledge Community.
Present status of production target and Room design Takashi Hashimoto, IBS/RISP 2015, February.
Ma zhongjian Ding yadong Wang qingbin Wu qingbiao Radiation Protection Group/IHEP.
1 Radiation Environment at Final Optics of HAPL Mohamed Sawan Fusion Technology Institute University of Wisconsin, Madison, WI HAPL Meeting ORNL March.
EURISOL, TASK#5, Bucuresti, November 1 Preliminary shielding assessment of EURISOL Post Accelerator D. Ene, D. Ridikas. B. Rapp.
Control of occupational exposure when working within a reactor containment building at power Matthew Lunn British Energy Generation Ltd. Sizewell B Power.
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 12.1 : Shielding and X-ray room design Practical.
Radiation protection studies for the ESS Activation issues AD seminar Michał Jarosz , Lund.
Mathematics for Computed Tomography
Louisiana State University Radiation Safety Office
Primary Radiation Calculation for Sun Yat-Sen Proton Hospital
CHAPTER 3 DOSE DETERMINATION FOR EXTERNAL BEAMS
Austrian Research Centers Seibersdorf
6th European ALARA Network Workshop Madrid, oct. 23rd 2002
Radioactivity – review of laboratory results
Radiation protection of Linac4 M. Silari Radiation Protection Group
Ch 10. A System of Dosimetric Calculations
X Rays Medical Physics Notes.
Occupational Radiation Dose Management
Monte Carlo simulations for the ODIN shielding at ESS
Sheng Yang a, Yen-Wan Hsueh Liu b
Radioactivity – review of laboratory results
Presentation transcript:

K. Oishi, K. Kosako and T. Nakamura Institute of Technology, Shimizu Corporation, Japan id=17 SATIF-10

2  Recently electric linac oncology facilities incorporating seismic base-isolation structure have become very popular in Japan to prevent strong impact to the equipments by the earthquakes.  When the boundary of the controlled area is set below the base- isolated foundations, additional shielding of iron plate is needed and the cost for shielding increases up to $100M. 2

3  Since no one usually accesses underneath the base-isolated foundation, except short maintenance period for base-isolation structure, it is reasonable to set the boundary around the downstairs room by fence. 3

44 concrete air room pit floor side X Z IC target and collimator 0°18.4° 33.7° 45° 53.1° 59.0° 63.4° iron  However, it is very difficult to estimate the dose rate of new boundary by using the simple shielding calculation method, because of rotating gantry head and effect of scattering radiation in the base- isolation floor.

5 1.To investigate the complicated behavior of photons in the “pit” by the analysis, (1) Which angle of the gantry will influence the most to the dose rate at the new boundary ? (2) How much can we reduce the thickness of additional iron plate ? (3) Which component of the radiation is dominant at the new boundary ? 2. To verify the calculated results by the measurement. 3. Assess the feasibility of simple calculation method from this study Objectives

66  Code:MCNP5  Library:EL3 for electron, MCPLIB04 for photon  Source:10 MeV electrons (pencil beam)  Target:Cu (2 cm-thick)  Tally:# cell tallies for photon and electron flux : lower layers in pit (1 cm-thick, 10x20cm 2 ) # point detectors for photon at positions estimated. The criteria of the boundary dose rate is 8.3 micro Sv/h. ( 1,300 micro Sv/h) /156 h = 8.3 micro Sv/h )

7 63.4° air concrete air room pit floor side X Z IC target and collimator 0°33.7°45°53.1° 59.0° boundary of controlled area cell tallies 100 cm 450 cm iron (1) Which angle of the gantry will influence the most to the dose rate at the new boundary ? The highest dose rate was obtained at the direction 0 degree.

88 (2) How much can we reduce the thickness of additional iron plate ? X air concrete iron air room pit floor side Z IC target and collimator 0° boundary of controlld area cell tallies 100 cm 450 cm No additional iron shield is necessary.

9 (3) Which component of the radiation is dominant at the new boundary ? attenuation scattering concrete pit IC boundary of control area iron To estimate the component of dominant radiation to the new boundary, we have performed calculation with and without base floor. The influence of scattered radiation from the floor became dominant to the new boundary at the position greater than 3m. It decreased constant inclination. Base floor

10 concrete air room pit floor side X Z IC target and collimator boundary of controlled area cell tallies 40 cm 5 cm 125 cm 130 cm 100 cm 450 cm 600 cm 100 cm 10 cm iron 150 cm air iron 100 cm space for turn table 170 cm 0 cm 5. Comparison between calculated and measured results Final shielding design

11 Very good agreement was obtained within 20%, except beneath iso-center and boundary. We have measured dose rate along the pit floor by ionization chamber.

12 Reasons of disagreement between calculated and measured results The structure of turn table in the treatment room concrete pit X Z IC boundary of control area iron space for turn table 0 cm # Anisotropy of turn table base was not considered in the calculation model. # Pipes and some equipments near the boundary were not considered in the calculation model. Pipes near the boundary

13 6. Possibility of simple calculation method TVL in the pit varied from 360 to 400 cm Although the structure of the shielding wall is different, the slope of attenuation coefficient is almost the same. The energy spectra of attenuated photons are also very similar. We may define Tenth Value Layer (TVL) in the pit for simple calculation method. concrete pit IC boundary of control area iron

14 : effective dose [μSv/(3 month)] at an evaluation position I 0 : X-ray dose rate [Gy/min] at 1 [m] of distance from target 60 : conversion coefficient from minute to hour unit 10 6 : conversion coefficient from Gy to μGy unit L : distance [m] from target to an evaluation position Dt : transmittance of shielding material with thickness t [cm] where ti: effective thickness [cm] of shielding material xi: Tenth value layer [cm] of shielding material T : operated time [hours/(3 month)] U : directional useful rate 1.0 : conversion coefficient from Gy to Sv unit. f : correction factor Dose rate outside of the primary barrier concrete pit IC boundary of control area iron Conventional calculation method for primary shield for linacs

Photon Dose-rate distribution at upper position in pit space for floor direction shielding (beam angle = 0 deg., current = 64.8  A). iron 55cm iron 50cm iron 45cm iron 40cm iron 35cm iron 30cm iron 25cm iron 20cm iron 15cm iron 10cm iron 5cm iron 0cm Distance on X-direction from IC [cm] f Result of simple calculation method = 0.57 micro Sv/h Result of MCNP5 calculation method = 0.36 micro Sv/h

16 7. Conclusion 1. We have performed the analysis of the behavior of photons in the pit and found out no additional iron shielding was necessary, which carried out an extreme reduction of costs. 2.Good agreement between calculated and measured results were obtained, and passed the examination by the authority. 3. It has been suggested there is a possibility of simple calculation method for the estimation of dose rate at the new boundary.

17