W504 – Bulk Analysis. Bulk Analysis - Introduction This session will not make you competent analysts! Aim is to make you aware of how samples are analysed.

Slides:



Advertisements
Similar presentations
Petrological Microscope
Advertisements

Fundamentals of Photoelasticity
Glass & Soil Review.
W504 - Asbestos types and properties. Asbestos – what is it? Naturally occurring fibrous silicate minerals Wide range of useful properties have led to.
POWERPOINT PRESENTATION ON POLARISED MICROSCOPE
Optical Mineralogy WS 2012/2013
Polarization of Light Waves
Glasgow Scientific Services Asbestos Dr Jim Lister Environment Group Manager.
Introduction to Light IN THIS LECTURE –Light –Electromagnetic Radiation –Wave Nomenclature –Electromagnetic Spectrum –Speed of Light –Wave front and wave.
Optical Mineralogy WS 2008/2009. Next week …. So far …. Light - properties and behaviour; Refraction - the refractive index (n) of minerals leads to.
BACTERIAL STAINING.
Liquid Crystal Technology Overview ECE-E443 Kai Chung Wong.
Indicatrix Imaginary figure, but very useful
The Optical Indicatrix
Mineral color and pleochroism
Extinction Angle and Pleochroism
L IQUID C RYSTALS P AUL D UPIANO M ANDEEP S INGH.
c = km/sec I F = I 0 x (cosθ) 2.
Study of Rocks 1) Field outcrop observe relationship between rocks
USE AND CARE OF THE MICROSCOPE LECTURE 1. MICROSCOPY u Light Microscopy: any microscope that uses visible light to observe specimens u Compound Light.
1 How do you study something that you cant see? You look at it under the microscope –But certain microbes (e.g. bacteria) do not have too many identifying.
The Polarizing Lens Microscope. Reticle Scale Objective4X4X 10 X 40 X Scale Bar (mm) Lg. Divisions (mm) Sm. Divisions (mm)
Introduction to Light and Polarized Light Lecture 1.
Liquid Crystals.
Reading Activity Questions? IB Assessment Statements Topic Polarization: Describe what is meant by polarized light Describe polarization.
PHYSICAL PROPERTIES – GLASS AND SOIL
Transverse wave is a wave in which the direction of displacement is perpendicular to the direction of propagation, as a surface wave of water.
Optical Mineralogy Technique utilizing interaction of polarized light with minerals Uses a polarizing microscope Oils - Grain mounts Thin sections – rocks.
Isotropic vs Anisotropic
Microscope.
Optical Mineralogy in a Nutshell
Analytical Tools Microscopy Chapter 4 ©2010 Elsevier, Inc.
O Aim of the lecture  Introduction of Waves water as a model Radio  Light representation with rays refraction reflection o Main learning outcomes  familiarity.
Identification of minerals with the petrographic microscope
The value of microscopy analysis Garry Burdett Health and Safety Laboratory Harpur Hill, Buxton, UK, SK17 9JN.
Copyright © 2006 Pearson Education, Inc., publishing as Benjamin Cummings Micro 20 Lab 2- Microscopy.
Function Parts and Function Different types. Scale 2.
Observing Microorganisms Through Microscopes
Honors Microbiology: Chapter 3 Microscopy and Staining
Microscopy Compound light microscope is composed of: 1- stand 2- stage 3- substage ( condenser, diaphragm) 4- body tube (carrying lens system) 5- light.
Experiment Questions Cell Microscopy - Plant and Animal.
  Any disintegrated surface material, natural or artificial that lies on or near the Earth’s surface.  Natural= rocks, minerals, vegetation, animal.
Interference Figures 1. Uniaxial Figures
Optical Mineralogy in a Nutshell Use of the petrographic microscope in three easy lessons Part I © Jane Selverstone, University of New Mexico, 2003 Used.
Biology Chapter 1 Biology as a science. Scientific Method.
Physics 11 Advanced Mr. Jean May 23 rd, The plan: Video clip of the day Wave Interference patterns Index of refraction Slit & Double Slit interference.
Optical Properties of Minerals
Starter: Microscopes Which image is from the light microsope? How do you know?
Waves: Physics AS LevelPage 1 Waves, Photons and Medical Physics AS Module 2 2.1Waves 2.2 Refraction 2.4Superposition and Interference 2.5 Diffraction.
What is a Stain A stain is a substance that adheres to a cell, giving the cell color. The presence of color gives the cells significant contrast so are.
The Microscope and Forensic Identification. Magnification of Images A microscope is an optical instrument that uses a lens or a combination of lenses.
GLG212 Part II, Lecture 1: Indicatrix and interference figures
1 Chapter 2 Steps in a chemical analysis Plan of analysis Before doing any quantitative analysis, the following questions should be answered: 1-
Optical Mineralogy in a Nutshell
By praveen. Light reflected from any smooth non diffusing Surface is said to be polarized or plane polarized. Eg :- snow,water Glare is commonly caused.
Observation of Microorganisms under Light Microscope
Tools of the Laboratory:
Microscope.
The Polarizing Light Microscope
Measuring Birefringence of Anisotropic Crystals
Light in Minerals II.
Types of Fractures by Projectiles
Optical Microscopy Study of how light passes through thin sections – rock cut and polished to about 0.3 mm thickness Use properties of light absorption.
Bright-Field Microscopy
Chapter 7 The Microscope
EQ: How is soil analyzed in forensic science?
Forensic Definition of Soil
Forensic Soil Analysis
LIGHT MICROSCOPY basic
Presentation transcript:

W504 – Bulk Analysis

Bulk Analysis - Introduction This session will not make you competent analysts! Aim is to make you aware of how samples are analysed and the limitations of the method Each asbestos type has slightly different chemical composition and crystal structure These differences are used to distinguish between the asbestos types (and between asbestos and other fibres)

Bulk Analysis - Introduction Multi stage process starting with initial examination by eye, then under low power microscopy, leading to a tentative identification Some fibres that have been tentatively identified are examined using polarised light microscopy at high magnification to confirm fibre type Note: Polarised light microscopy is the most widely used method but other methods are available.

Health and Safety Precautions Asbestos fibres need to be released from the sample matrix, so appropriate precautions must be in place All initial examination and sample preparation should be undertaken inside a safety cabinet Minimum face velocity of 0.5m/s. Fitted with a high efficiency “HEPA” filter. Visual indicator showing correct functioning Checked every day Tested every 6 months Risk assessments and precautions for working with acids, solvents and refractive index liquids

Typical safety cabinet

Initial Examination Entire sample examined by eye Initial assessment of possible type of asbestos product Visible fibres present or not? If sample non-homogenous each part examined Examination of sample using low power microscope Visible fibres present or not? Initial assessment of type(s) of fibre present Very fine fibres may still not be seen at this stage Appearance, colour and texture of any fibres noted and recorded

Sample Preparation Purpose of sample preparation Ensure fibres released from sample matrix Remove fine particles adhering to fibres Obtain dry fibres (essential for dispersion staining) Sample preparation techniques include Physical extraction – tweezers, scraping of surface Acid digestion Solvent extraction Combustion (below 400 o C) Wet grinding

Stereo microscopy Examination of sample inside safety cabinet Colour (blue, white etc) Elasticity (does the fibre return to its original shape when distorting force removed) Tenacity (resistance to breaking) Morphology (its form, structure) How fine are the fibres? Are the fibres in bundles?

Stereo microscope examination

Transferring fibres onto slide Tentative identification of fibres is used to select the most appropriate refractive index liquid for subsequent analysis Fibres that are dry, relatively free from other adhering particulate matter chosen Placed into a drop of refractive index liquid on microscope slide Glass cover slip placed on top of liquid drop

Refractive index liquids

Polarised Light Microscopy Light is a type of energy that travels in the form of a wave Ordinary (un-polarised) light contains light vibrating in all directions Polarised light has a single vibration direction Ordinary light can be polarised with a polarising filter Some materials e.g. glass, some plastics are isotropic – they only have one refractive index Many materials e.g. asbestos fibres, many crystalline materials are anisotropic – they have more than one refractive index Polarised light is used to study anisotropic crystals

Colour and pleochroism Pleochroism – coloured anisotropic substances show different colours at different orientations relative to polarised light Crocidolite fibres showing pleochroism

Birefringence Anisotropic materials have different refractive indices The numerical difference between the different refractive indices is the birefringence i.e. Large difference in refractive indices – high birefringence Small difference in refractive indices – low birefringence Anisotropic materials show maximum interference colours and / or brightness against a dark background when aligned at about 45 o to the vibration plane of the polarised light

Birefringence

Crystalline materials with more than one refractive index (anisotropic) show birefringence under crossed polars. Isotropic materials (for example, glass fibre) have only one refractive index and do not polarise the light transmitted through them They show no birefringence and are distinguished easily from asbestos under cross polars - they are barely visible but will be seen easily with slightly uncrossed polars

Angle of extinction As the microscope stage rotates, an asbestos fibre viewed between crossed polars will disappear from view or “extinguish” at four positions each 90 o apart. Between each extinction interference colours should be visible. Chrysotile, amosite, crocidolite and anthophyllite extinguish when the fibre is parallel to the vibration orientation of the polariser or analyser. Actinolite and tremolite asbestos exhibit parallel or very nearly parallel (less than 5 o from parallel) extinction.

Sign of elongation The colour changes indicate whether the high refractive index vibration plane of the fibre is parallel to the long or short axis of the fibre (i.e. length fast or length slow) Crocidolite is the only asbestos type which usually shows a negative sign of elongation (length fast) Note: This can reverse if the fibre has been subjected to high temperatures

Sign of elongation Chrysotile fibres

Dispersion staining Dispersion staining colours will be observed when the fibre is immersed in a liquid with a refractive index close to that of the fibre in question Different colours will be produced when the fibres are oriented parallel or perpendicular to the polariser The presence of the correct dispersion staining colours is the final piece of evidence to confirm the identity of the asbestos fibres (which up to this point has only been a tentative identification)

Dispersion staining To produce dipersion staining colours the fibre must be immersed in a liquid with a refractive index close to that of the fibre in question There are different refractive index liquids commercially available The following refractive index liquids are used for asbestos identification Crocidolite Amosite Actinolite Anthophyllite and Tremolite Chrysotile

Dispersion staining Chrysotile fibres in refractive index liquid 1.55

Analysis of amosite

Analysis of chrysotile

Quality control Bulk analysis should only be undertaken by a trained and experienced analyst Organisation should have a in-house quality assurance programme in place In addition the organisation should take part in an external proficiency testing scheme e.g. AIMS or BAPAT In many countries accreditation to ISO17025 is mandatory e.g. UKAS, NATA, AIHA There are some recommendations on the maximum number of that should be analysed in a day

Detection limits In theory the method is capable of detecting as little as 1 part per million asbestos in a sample However, it is likely that this level of contamination may often not be detected It is important that any cross-contamination of samples is avoided Note: Percentage of asbestos in a sample cannot be determined by the method described earlier

Detection limits Most asbestos containing products contain at least 0.1% asbestos Many authorities define asbestos-containing in terms of licensing or waste regulation requirements This is often set at 0.1% Materials with less than 0.1% asbestos are not ‘asbestos-free’ but may be at a level where the risk assessment may not raise special concerns

Interfering products and fibres The analytical method can differentiate between the 6 asbestos types It can also differentiate between asbestos and other fibres such as glass fibre, vegetable fibres, refractory ceramic fibres etc However, some fibres show similar characteristics on examination which may lead to problems in analysis – an experienced analyst should be able to distinguish them Substances that may interfere include shredded polyethylene, leather swarf fibres, aramid fibres, some natural organic fibres, talc fibres and some mineral fibres