High resolution SFOV gamma camera systems

Slides:



Advertisements
Similar presentations
Imaging Molecolare con radionuclidi: un potente mezzo di indagine di processi biologici in vivo F. Garibaldi - Fisica e tecnologie Nucleari per la Salute.
Advertisements

X-Rays In Medicine Noadswood Science, 2013.
David Rothery, Dept of Earth & Environmental Sciences X-Ray detection techniques and the BepiColombo-MIXS instrument.
Gamma Camera Quality Control
1 ATST Imager and Slit Viewer Optics Ming Liang. 2 Optical layout of the telescope, relay optics, beam reducer and imager. Optical Layouts.
King Abdul-Aziz University Diagnostic Radiology Department MS.Nouf Al-Zahrani DR. Saddiq Jastniah Introduction to Nuclear Medicine 2 nd year.
Digital Radiography.
RAD 354 Chapt. 26 Digital Imaging Many types/names for the digital imaging to come – Types CR: Barium fluorohalide PSP SPR (scan projection RAD): Nal scintillator/photodiode.
Future Of Diagnostic Imaging A Look Into The Next Decade ? (Part 1)
Skin Lesion James Warneke, MD University of Arizona.
Frank P. Dawry LYMPHOSCINTIGRAPHY Sentinel node localization in Melanoma.
Overview of XMM-Newton XMM-Newton carries three, co-aligned, densely-nested, grazing incidence telescopes, collectively providing unparalleled effective.
Sentinel Lymph Node Biopsy in Melanoma
Kit for the Preparation of Technetium Tc 99m Sulfur Colloid Injection For Subcutaneous, Intraperitoneal, Intravenous and Oral Use For Diagnostic Use by.
Development of a compact gamma camera for intra operative radiation imaging Konstantinou G. 1, Chil R. 1, Desco M. 1,2, and Vaquero J.J. 1,2 1 Departamento.
Current Topics in Medical Physics Research Xiaoming Zheng, PhD. School of Dentistry and Health Science Chengdu, China, 2009.
Nuclear Medicine Spring 2009 FINAL. 2 NM Team Nuclear medicine MD Nuclear medicine MD Physicist Physicist Pharmacist Pharmacist Technologist Technologist.
Gamma Camera Technology
LXO/MagEX Meeting Greenbelt, 24/10/07 Telescope Baseline Configuration: Imaging Capability (Micropore Optic) Telescope Field of View ~ 30° x 30° Angular.
Topics in Medical Physics Xiaoming Zheng, PhD. School of Dentistry and Health Sciences December 2009, Chengdu.
6 November 2007Cal-Ops Meeting Mallorca Recent Results from EPIC MOS Life Test Facility Tony Abbey and Craig Brown University of Leicester Space Research.
30 August 2006 Sensing. Refresher on Complex Numbers
Lecture 2-Building a Detector George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Paul Sellin Detector Research at the University of Surrey Dr Paul Sellin Centre for Nuclear and Radiation Physics Department of Physics University of Surrey,
Direct Digital Radiography or Direct Capture Radiography Bushong Ch. 27.
DIAGNOSTIC $ THERAPEUTIC NUCLEAR MEDICINE. Presented at the KNH Research Symposium On 13 th April 2012 PRESENTER: DR. DAVID NDIRANGU THEURI Nuclear medicine.
CCD Detectors in High- Resolution Biology Jian Guan
Image formation & Geometrical Transforms Francisco Gómez J MMS U. Central y UJTL.
– The clinical utility of ultrafast cardiocentric 3D SPECT novel semi-conductor scanner technology – Berry Allen PhD 31 August 2013.
8/18/2015G.A. Fornaro Characterization of diffractive optical elements for improving the performance of an endoscopic TOF- PET detector head Student: G.
Introduction to Nuclear Medicine
Autonomous Robotics in Medicine Michael Saracen February 11, 2009.
Design and simulation of micro-SPECT: A small animal imaging system Freek Beekman and Brendan Vastenhouw Section tomographic reconstruction and instrumentation.
November 8, 2005JLAB Awake Animal Project New Instrumentation for JLAB Awake Animal Project Smaller Pixel Size requires higher granularity in PMT (2.4.
Development of New Detectors for PET Imaging at BNL DOE/JLAB Meeting Bethesda, MD May 20, 2004 Craig Woody Physics Dept Brookhaven National Lab RatCAPBeta.
Space Research Centre Silicon Carbide X-Ray detectors for Planetary Exploration Dr. John E. Lees University of Leicester 8 th International Conference.
M. Alnafea1*, K. Wells1, N.M. Spyrou1 & M. Guy2
12/09/2011Position Sensitive Detectors 91 &. 12/09/2011Position Sensitive Detectors 92 Tracking of Moving Fiducial Markers during Radiotherapy using a.
Imaging of Ra-223 with a small- pixel CdTe detector: potential for improved image quantification for radionuclide dosimetry James Scuffham 1,2 Silvia Pani.
M. D. A NDERSON Cancer Center Nuclear Imaging (M.Cam) Richard E. Wendt III, Ph.D. and William D. Erwin, M.S. Small Animal Cancer Imaging Research Facility.
Lymphoscintigraphy and SNLB in
Uses Of X-Rays And Gamma Rays Georgina Randell. Similarities and difference and how x- rays images are created  X-rays and gamma rays are used in medicine.
1 Wojciech Dulinski Pixel 2000, Genova, Italy Pixel Sensors for Single Photon Detection Contents - Idea and basic architecture.
Filipe Castro Departamento de Física & i3n Universidade de Aveiro C S I(N A ) W AVELENGTH - SHIFTING FIBER GAMMA CAMERA USING S I PM S LIP Lisboa Apr.
RAD 254 Chapter 27 Digital Fluoroscopy
Victor Hess in his balloon (1912). Cosmic Rays Produce Muons in the Atmosphere.
Prostate probe with SPECT technique NSS – MIC November 5 - KnoxvilleF. Garibaldi- INFN – Roma1 – gr. Coll. ISS  the medical problem  the proposal.
PSD-V, London, September 1999 Two dimensional readout in a liquid xenon ionisation chamber V.Solovov, V.Chepel, A.Pereira, M.I.Lopes, R.Ferreira Marques,
Improved Hybrid PET Imaging Using Variable Focal Length Fan-Slat Collimators Thomas C. Rust and Dan J. Kadrmas, Ph.D. Medical Imaging Research Laboratory.
Compton imaging with the PorGamRays Detector D S Judson Imaging 2010, Stockholm, 8 th -11 th June 2010.
Active Pixel Sensors in Medical and Biologi The application of Large Area Active Pixel Sensor (LAS) to high resolution Nuclear Medicine imaging Bob Ott.
Acquisition time6 min1 min 12 s Collimator height25 mm (Anger)12 mm (HiSens) Detector1 layer, 1 pixel / hole3 layers, 1 pixel / hole3 layers, 4 pixels.
Geometry Calibration for High Resolution Small Animal Imaging Vi-Hoa (Tim) Tran Thomas Jefferson National Accelerator Facilities.
RAD 354 Chapt. 26 Digital Fluoro Terms to remember – DSA – digital subtraction angiography – Registration – Interrogation time – Hybrid subtraction – CCD.
Familial Bilateral Osteochondritis Dissecans of the Femoral Head by Mark C. Lee, Derek M. Kelly, Daniel J. Sucato, and John A. Herring J Bone Joint Surg.
Nuclear Medicine Introduction
Prostate probe with SPECT technique NSS – MIC November 5 - KnoxvilleF. Garibaldi- INFN – Roma1 – gr. Coll. ISS  the medical problem  the proposal.
Muhammad Musaddiq.
Evaluation of a CCD Imaging Detector with the Medipix2 Detector J. Touš - Crytur Ltd., Turnov, Czech Republic J.Žemlička, J. Jakůbek – IEAP, Prague, Czech.
An introduction to Breast Cancer and Unmet Clinical Needs
SCINTILLATOR STURUCTURE
Frank L. Glass, MDa, John A. Cottam, MDb, Douglas S
A Model for Breast Services in North Wales
Surgical Cancer Treatment
Schemes of portable  imagers
Application of Nuclear Physics
Gamma Ray and Beta Ray Probes
A Dual-layer Detector for Simultaneous Fluoroscopic and Nuclear Imaging  Real-time hybrid fluoroscopic and nuclear imaging may provide the physician with.
Treatment Overview: The Multidisciplinary Team
Development of a Large Area Gamma-ray Detector
Presentation transcript:

High resolution SFOV gamma camera systems John Lees University of Leicester

UoL Space Research Centre Technologies and Expertise Optical, UV, X-rays, gamma rays Charge Coupled Devices: CCD XMM-Newton: EPIC

Gamma Cameras and Probes A dual head gamma camera A nuclear probe detector

Mini Gamma Ray Camera (MGRC) Scintillator coated CCD Complementary to “standard” Gamma Camera High spatial resolution (<1mm) Energy range 30-160 keV. International Patents Hand held potential Point of care testing

Mini Gamma Ray Camera (MGRC) e2v CCD 97 BI 16 µm pixels 512 x 512 pixels 8 mm x 8 mm Pinhole collimators: FOV 40mm x 40mm

Camera Schematic The mini gamma camera Columnar CsI Each column acts as a “light pipe” The mini gamma camera

Phantoms

Mini-Phantom

Phantoms 99mTc image of leg and hips Mouse phantom

Comparison with WBGC Hot spot Phantom 99mTc 15 mm

MGRC performance Sub-mm spatial resolution ~0.9mm @ 25mm Interesting Energy Resolution

Clinical Applications & Evaluation lacrimal drainage (eye) Sentinel node detection (breast) Sentinel node detection skin (melanoma) Joint imaging Nasal clearance (drug delivery studies) General surgical exploration in bone (osteoid osteoma) tumour detection, (colon, ovary). thyroid morphology

Sentinel Node Detection RCS New Start Programme 2007-2008: Sentinel Lymph Node Biopsy Training Programme Regionally run programme aimed at all members of the breast care team.

Design evolution - MGRC

Clinical prototype design

Clinical prototype design MGRC in clinical setting MGRC prototype

Clinical trial, QMC Nottingham Tc-99m-HDP bone imaging in patient Conventional gamma camera HR Mini gamma camera

Tc-99m-MIBI Parathyroid Study

Multi-wavelength approach The Milky Way Man Near-Infrared Optical X - rays Gamma rays

Hybrid camera Minimises parallax Minimises image registration problems A combined optical and gamma camera system Co-aligned optical and gamma camera Minimises parallax Minimises image registration problems

Lymph node phantom

Hybrid Imaging

Benefits of SFOV Cameras High spatial resolution (<1mm) Energy range 30-160 keV. Hand held potential Point of care imaging Intra-operative imaging will Improve patient management Increase surgical confidence Reduce surgery time Reduce cost of treatment

Acknowledgements Space Research Centre, Leicester David Bassford, Oliver Blake, Tony Abbey, George Fraser, Duncan Ross, Chris Bicknell Massimiliano Canali University of Nottingham Alan Perkins and Elaine Blackshaw De Montfort University Peter Ford and Lee Cottrell