EBC Seminar The IAQ/Mold Assessment – Getting it Right! – Controlling Your Risk Next Speaker Rosemary McCafferty Haley & Aldrich, Inc.

Slides:



Advertisements
Similar presentations
IEC C ASE S TUDY PRESENTED BY: Mark D. Fisher, CHMM, LSRP Principal – The ELM Group, Inc.
Advertisements

Vapor Study Informational Meeting General Mills/Henkel Corp. Superfund Site Van Cleve Recreation Center November 12, 2013 Minnesota Department of Health.
VAPOR INTRUSION: AN INTRODUCTION OHIO COMMUNITY DEVELOPMENT CONFERENCE JENNIFER MILLER NOVEMBER 7, 2012.
Case Study of Subsurface Vapor Intrusion at a Dry Cleaner Site Amy Goldberg Day AEHS Annual East Coast Conference on Soils, Sediments.
Learning from the States… Commonwealth of Massachusetts
2014 Vapor Intrusion Guidance Amendments Discussion Points Waste Site Cleanup Advisory Committee Meeting May 22, 2014.
Vapor Intrusion. What is Vapor Intrusion? The migration of volatile chemical vapors from the subsurface to overlying buildings.
Vapor Intrusion: When to Worry? NAREIM National Assn of Real Estate Investment Managers Las Colinas, TX September 26, 2012 Beverlee E. Silva, Esq. Alston.
Claremore Medical Office Building From Landfill to Medical Office Building A Brownfield Success Story THE GREEN SIDE OF BROWNFIELD REMEDIATION.
Further Site Investigation Sutton Walls Former Landfill
Forensic Analysis and Sorbent Collection Methods MSRAS Soil Gas Sampling Workshop Indianapolis, IN August 21-22, 2006 Gina Plantz NewFields Environmental.
Environmental Investigation by Con Edison Former E115th Street Gas Works November 13, 2007.
Vapor Intrusion: Investigation of Buildings Overview of the US vapour intrusion framework, empirical attenuation factors, and the conceptual understanding.
Vapor Intrusion Workgroup July 29,
RADON The Health Risks and Solutions. What is Radon? A naturally occurring radioactive gas. Colorless, odorless and tasteless. Found all over the U.S.
EnviroSense, Inc. An Overview of Environmental Factors in Developing Brownfields Sites in Massachusetts Presented By: Eric S. Wood, P.Hg., PG, LSP President.
Vapor Intrusion Guidance Proposed Updates
DRAFT Field Sampling Guidance To be used this field season by DEC and consultants Initial focus on soil, groundwater, and vapor intrusion Future versions.
Vapor Intrusion Evaluation Strategy and Modeling Developments
Revised TCE Fact Sheet (a.k.a. “Status Update”) Q&A’s & Template IH Notice Form March 27, 2014 Paul W. Locke MassDEP Bureau of Waste Site Cleanup (617)
Radon Overview Reducing Radon in a Home. Learning Outcomes Upon completion of this module you will be able to:  Recall the most common method to reduce.
Overview of US EPA’s Vapor Intrusion Guidance VAP CP Summer Coffee July 14 th, 2015 Carrie Rasik Ohio EPA CO- Risk Assessor
Of Massachusetts Department ENVIRONMENTAL PROTECTION Soil Vapor Intrusion... A Decade of Regulatory Requirements & Experiences Paul W. Locke MA DEP Bureau.
Gradient CORPORATION Vapor Intrusion Attenuation Factors (AFs) – Measured vs. EPA Defaults A Case Study Presented by Manu Sharma and Jennifer DeAscentis.
DTSC VAPOR INTRUSION GUIDANCE California Industrial Hygiene Council 16 th Annual Conference Dan Gallagher Department of Toxic Substances Control California.
COMMITMENT & INTEGRITY DRIVE RESULTS WAITING TO EXHALE – OR HOW TO MANUEVER THROUGH THE INDOOR AIR MAZE Vapor Intrusion Pathway By: Lisa Campe, MPH, LSP.
Predicting Vapor Intrusion Risks in the Presence of Soil Heterogeneities and Anthropogenic Preferential Pathways Brown University Ozgur Bozkurt, Kelly.
Vapor Intrusion and Environmental Liability Learning From Past Mistakes EDR Insight Webinar, February 12, 2013 Presented by: Joseph Maternowski Hessian.
Background and lessons learned Managers Meeting February 13, 2014.
About Engineering Control Corp (ECC) provides construction design, support services and engineering controls to mitigate.
Modeling Vapor Attenuation Workshop A Study of Vapor Intrusion Modeling in the Context of EPA’s Guidance The 20 th Annual International Conference on Soils,
Discerning Background Sources from Vapor Intrusion Jeffrey Kurtz, Ph.D. and David Folkes, PE EnviroGroup Limited Denver Boston Albuquerque Seattle Colorado.
Modeling Vapor Attenuation Workshop A Study of Vapor Intrusion Modeling in the Context of EPA’s Guidance USEPA’s (OSWER) Nov Draft Guidance for Evaluating.
VI Draft Guidance: Overview of Comments to November, 2002 OSWER VI Guidance Michael Sowinski DPRA, Inc.
Monitored Natural Attenuation and Risk-Based Corrective Action at Underground Storage Tanks Sites Mike Trombetta Department of Environmental Quality Environmental.
SITE STATUS UPDATE TOP STOP PETROLEUM RELEASE SITE GUNNISION, UTAH Morgan Atkinson – Division of Environmental Response and Remediation, Project Manager.
USEPA Region 2 Vapor Intrusion Study Cayuga Groundwater Contamination Site March 4, 2009.
© 2008 Fox Rothschild MANDATORY GOVERNMENTAL REQUIREMENTS AND INCENTIVES: VAPOR INTRUSION June 25, 2008 By David Restaino, Esq. and Burton J. Jaffe, Esq.
Preparing a Site Conceptual Model. Typical Site Management Problems: Site complexities  Complicated hydrogeology  Multiple contaminants of concern (COCs)
Potential Addition of Vapor Intrusion to the Hazard Ranking System U.S. EPA Office of Solid Waste and Emergency Response February 24, 2011 Listening Session.
GORE, GORE-TEX and designs are trademarks of W. L. Gore & Associates © 2007 W. L. Gore & Associates, Inc. 1 Environmental Investigations Using Versatile,
Vapor Intrusion Guidance Updates VAP CP Training October 27, 2015 Audrey Rush Ohio EPA DERR
Charge Questions for Expert Panel Modeling Vapor Attenuation Workshop Annual International Conference on Soils, Sediments, and Water October 19, 2004 Amherst,
FAIR Meeting April 6, Groundwater Results – Fall 2003 Benzene ND 1,000 ug/L Product.
Massachusetts Waste Site Cleanup Program _________________________________ Privatized program since 1993 Direct oversight of only the highest priority.
1 FORMER COS COB POWER PLANT From Characterization to Redevelopment Brownfields2006 November 14, 2006.
UNEXPECTED VOCS IN SOIL GAS ASSESSMENT RESULTS James M. Harless, PhD, CHMM Vice President / Principal Cheryl Kehres-Dietrich, CGWP Principal Paul Roberts.
Evaluation of Methane Pathway, Risk and Control Rafat Abbasi, P.E., Senior Project Manager Brownfields and Environmental Restoration Program Department.
Vapor Study Informational Meeting General Mills/Henkel Corp. Superfund Site Van Cleve Recreation Center November 12, 2013 Minnesota Department of Health.
Building Trust. Engineering Success. Real-time Vapor Intrusion Investigations in Industrial Buildings Using Portable GC-MS Presented by: Paul Gallagher,
Human Impact on the Atmosphere Human Impact on the Atmosphere Chapters 18 and 19 Living in the Environment, 11 th Edition, Miller Advanced Placement Environmental.
The World of AUL Presentation by: Atul Pandey, P.E. PANDEY Environmental, LLC 2016 Ohio Brownfield Conference April 7, 2016.
The Indoor Inhalation Exposure Route Heather Nifong Illinois EPA May 5, 2008.
Risk CHARACTERIZATION
Welcome to the World of AUL Avoiding the voidance of your CNS.
What’s the Problem: The Vapor Intrusion Issue Brownfields 2008 Heavy Starch: Cleaning the Dry Cleaners Detroit, MI May 5, 2008 Presented by: Henry Schuver,
Lenny Siegel Center for Public Environmental Oversight Brownfields 2008—May 7, 2008 LONG-TERM MANAGEMENT at Schools with Shallow VOCs.
ASTM Standard Practice for Assessment of Vapor Intrusion Into Structures on Property Involved in Real Estate Transactions: Status Report presented by Anthony.
Proposed Plan for No Further Action
General Principles for Hydrocarbon Vapor Intrusion
Chemical Metals Industries, Inc. (CMI)
Welcome.
Jay Peters Gina M. Plantz Richard J. Rago
Using the HAPSITE® as a Vapor Intrusion Investigation Tool
At facilities with subsurface contamination, what other chemicals may your workers be breathing? Matt Raithel.
Connecticut Remediation Standard Regulations: Volatilization Criteria
How can you reduce radon in a home?
Hold Your Breath—Ohio EPA’s TCE Initiative
Radon Vapor Intrusion Screening Level Calculator
Chemical Metals Industries, Inc. (CMI)
Presentation transcript:

EBC Seminar The IAQ/Mold Assessment – Getting it Right! – Controlling Your Risk Next Speaker Rosemary McCafferty Haley & Aldrich, Inc.

Outline Vapor Intrusion Overview Vapor Intrusion Sampling Vapor Intrusion Evaluation Consideration Remediation Case Study Questions

Vapor Intrusion Overview: Vapor Intrusion to Indoor Air Vapor intrusion is the migration of volatile chemicals from the subsurface (soil gas) through cracks in the foundation and into indoor air. Sources can be soil, groundwater or free product (LNAPL).

Soil Gas Properties And Factors Affecting Its Behavior Soil gas enters structures through the openings in the foundation. The concentration found in any building is determined by several factors, including: –the concentration of gas in the soil –the permeability of the soil –the pressure differential between the soil and the building –other preferential pathways Most buildings exert a negative pressure on the soil because of the natural stack effect and exhaust devices that exist in all buildings. This “stack effect” can bring in soil gas.

State Vapor Intrusion Guidance Not evaluated Defers to federal program Developed/developing program with varied flexibility Developed program with varied flexibility, including numerical standards/screening criteria Conservative program with substantial regulatory oversight Currently developing guidance No guidance; pathway not evaluated currently

Attributes of MA, NY, and NJ Guidance MANYNJ Trigger distance (feet) GW: 30H; 15V Soil: 6H; 10V H; 30V? Modeling vs. Measurem ent Measurem ent Numerical criteria GWIA (5 compound s) IA, possibly SV and GW Backgroun d #s incorporate d? Yes No Analyte listSite- related SV: “wide range” IA: site- related Full suite TO-15 Outdoor air sampling? Yes Hypothetic al future use? NoYes

Massachusetts DEP VI Regulatory Guidance GW-2 Groundwater-to-Indoor Air Standards Indoor Air Sampling & Evaluation Guide, April 2002 Tiered, risk-based approach: –Generic cleanup standards, –Site-specific standards using modeling, –Site-specific risk assessment Background included quantitatively in standards and evaluation (75 th - 90 th percentile literature value) **Critical Exposure Pathways – “measurable concentrations of OHM into the living or working space of a pre-school, daycare, school or occupied residential dwelling…” –Experience says that “background” is not always sufficient. Individual case managers may require non-detects.

Vapor Intrusion Sampling: When VI would be evaluated (in MA) Presence of occupied building Groundwater concentrations (MA trigger distances) exceed GW-2 standards Volatile compounds detected in soil (no screening levels provided) Presence of LNAPL/free product (MA trigger distances) Soil gas concentrations above screening values (petroleum sites only) Known or suspect source beneath structure

Definitions Of Soil Gas Gaseous compounds (and/or elements) in the spaces between particles of the earth and soil. These gases can be moved or driven out under pressure. Soil gas is vapor that can be extracted from the subsurface, from pores in unconsolidated material above the water table.

Bang Bar Installation source: Solinst

Soil Gas from Permanent Well

Indoor Air Sampling Considerations Conceptual Site Model Site-Specific Compounds of Concern Building Survey Preferential Pathways Background* Individual or Batch Cleaned Canisters Sample Collection Method TO- 15/-14/-17, APH Certified Laboratories

When to Collect Indoor Air Samples? (Indoor Air Sampling and Evaluation Guide, MADEP, April 2002)

Indoor Air Background Things that are present at a site in the absence of a release May be naturally occurring or anthropogenic Mold, Moisture, Radon, Pet allergens Carbon dioxide and Carbon monoxide Asbestos and Particulates VOCs/SVOCs Can differ from residence to residence & from night to day Background sources/studies EPA VOC Database/Shah and Singh – 1988 Stolwijk – 1990 MA DEP IA Hydrocarbon Study – 1997 H&A/Alpha Labs MA Residential IA Study- 2004/2005

Vapor Intrusion Evaluation Considerations (in Massachusetts)

Evaluation of Potential Indoor Air Impacts from Subsurface Source 1.Compare groundwater, soil and/or soil gas concentrations to screening levels If groundwater or soil gas concentrations do not exceed screening levels AND no precluding factors exist, then no further action is necessary. Precluding factors include: –Preferential migration pathways (e.g., utilities, sumps, openings to the subsurface) –Very shallow vapor sources or wet basements –Very “tight” buildings with low air exchange rates or high indoor/outdoor pressure differentials 2.Groundwater, Soil, Soil Gas Modeling

Evaluation of Potential Indoor Air Impacts from Subsurface Source 2.Compare list of indoor air contaminants to subsurface contaminants –Chemicals detected in both subsurface media and indoor air are more likely to be site-related –Indicator compounds not commonly found in household products (e.g., 1,1-DCE, radon) –Potential for reverse migration of vapors to occur (from building interior to sub-slab) 3.Compare indoor air concentrations to literature or site-specific background values and outdoor air concentrations

Evaluation of Potential Indoor Air Impacts from Subsurface Source 4.Compare indoor air concentrations from different levels (or areas) to evaluate presence of concentration gradients. basement 1st floor 2nd floor soil gas groundwater

Remediation: Setting Cleanup Standards Risk Based Targets Background Values Non-Detect (CEP)

Consider Vapor Mitigation Options Engineering Controls –Floor slab sealing –Vapor barriers –Increased ventilation –Sub-slab depressurization Institutional Controls –Deed restrictions Active Remediation –SVE Monitoring –Long-term costs –Ownership –Liability –Public perception (USEPA-TIO Internet Seminar, February 11-12, 2003.

Summary Management of VI sites differs between states Sampling should be guided by historic information, site conditions, and available data Cleanup standards will depend on site use VI mitigation is often a cost- effective solution, especially when implemented during construction or redevelopment

Case Study Site: 6 Family Residence Conditions: adjacent dry cleaner potential source of legacy chlorinated solvents; groundwater < GW-2, however, elevated soil gas Identified: Substantial Release Migration “releases to the groundwater that have resulted or are within one year likely to result in the discharge of vapors into school buildings or occupied residential dwellings.” Installed and are operating of a subslab depressurization/ventilation to mitigate the volatilization of VOCs into the building from the underlying groundwater. Assessed indoor air quality to evaluate the effectiveness of the subslab system

Thank You State and federal vapor intrusion guidance and references can be found at: html html Searchable, indexed database for household products: Questions?