M Family Industrial Systems 1 M Family relays provide economical & reliable digital protection, metering, control and monitoring in an integrated package.

Slides:



Advertisements
Similar presentations
Variable Frequency Drives Bypass Options
Advertisements

DS|POWER DS300 series New generation DSP controlled Uninterruptible power supplies.
CL100D series DSP controlled Uninterruptible power supplies.
سیستم آلارم دیجیتالی مجهز به ثبات خطا
Square D Electrical Protection And Monitoring
Model H Free Standing Static Transfer Switch. Why choose a model H static transfer switch? Increases power availability. True solid state. Rugged, reliable.
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
UR - The Universal Relay
1 GE Digital Energy Multilin Industrial Solutions for Energy Management and Energy Efficiency By John S. Levine, P.E. Levine Lectronics and Lectric, Inc.
Multi Functional Digital Fault Recorder
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin
1 Industrial Systems Advanced Protection, Monitoring, Control, & Communications in One Integrated Package! Universal Recloser Control (URC) Reliable reclosing.
GENERATOR PROTECTION.
Protections from the technical point of view “What you always wanted to know about protections and were afraid to ask…” Petra Píclová Online training
EVD4 - The Smart eVolution Primary distribution circuit-breaker with integrated protection, control and sensors © ABB Group 15. April 2017 | Slide 1 1.
FP5000 Refer to for the latest information on this constantly evolving productwww.eatonelectrical.com.
W650 Wind Generator Protection System
Application & Configuration
SYMAP-BC SYMAP-BC.
Generator Management Relay
Generator Protection System
SR489 Generator Management Relay
Slide 1 / 35 P&T - GPS - Training PhB - 01_TECH_TeSys_U_controller_ en 06/2004 Presentation of the range Composition of the controller  Control base 
GE Consumer & Industrial Multilin  Single & Three phase models  Specific mount CT’s  Rectangular & Toroidial models  Plastic case & cast models  Multi.
G GE Power Management MMII Intelligent MCC Controller.
Generator Protection. Amount of Protection Rated power of the generator Ratio of its capacity to the total capacity of the system Configuration of the.
Industrial Systems Introducing the L90 Universal Relay Advanced transmission line protection and control High-speed current differential protection for.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
Make the most of your energy December 2008 PowerLogic Enercept Submetering ….when space is at a premium PowerLogic® Enercept Meter.
MIG II DIGITAL FEEDER PROTECTION
The Peak in Performance
G GE Power Management 369 Motor Management Relay.
1 Industrial Systems A dvanced L ine P rotection S ystem.
Workflow Based Tools Simplifying All Job Functions.
ZTE Series Automatic Transfer Switches (ATS)
Copyright © 2008 Rockwell Automation, Inc. All rights reserved. Direct-to-Drive Technology Product Feature Overview.
SCADA and Telemetry Presented By:.
Interconnect Protection of Dispersed Generators
G650 Generator Protection & Control System
April 2011 ezPAC SA320/330. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Make the most of your energy Make the most of your energy SM Add application photo in this area Need an easy to use, modular system for revenue metering?
Electrical Distribution Training
Prepared By :.  Introduction  Techniques Used  Case Study  Advantages  Application  Conclusion OUTLINE.
1 Monitor System Reliability alarm on demand, sag/surge, and etc. Perform Advanced Power Quality Analysis provide real-time trending. Centralized.
VS mini J7 COMPACT INVERTER FOR GENERAL USE
AQ 100 Series Arc Flash Protection System. Characteristics of arc protection Speed, no intentional delays Sensitive, current set-points just above loads.
3-Phase Submersible Motor Control
YASKAWA VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase).1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase).1Kw ~ 7.5Kw (.13HP.
Protection & Switchgear
SmartMQn Motor Horner APG, LLC September 9, 2008.
Franklin Electric - The Company You Trust Deep Down Provides The Ultimate Protection for Your Pump & Motor! Franklin SubMonitor.
New product introduction:
1 Industrial Systems BUS2000 Busbar Differential Protection System Differential overcurrent system with percentage restraint protection.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
G GE Power Management 269Plus Motor Management Relay.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
Altivar 32 So slim, So smart!
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 1 HighPROTEC-2 MRI4-2 Feeder Relay Sales presentation 2015/08/10.
HighPROTEC-2 MRA4-2 Directional Feeder Relay Sales presentation
Protection of Power Systems
By, Rakesh Das B.P.E-4 th yr. Roll No th August’ 2011.
MiCOM P125 P126 & P127 27th, Aug 2007 Lakshmikanthan Balaji Application Engineer.
HighPROTEC-2 MRM4-2 Motor Protection Relay Sales presentation
Interconnect Protection of Dispersed Generators
FEEDER PROTECTION UNIT
Chapter 7 System Protection
Protection Philosophy
PowerLogic™ offer for the basic metering market
PowerLogic ION6200 Power and energy meter.
Presentation transcript:

M Family Industrial Systems 1 M Family relays provide economical & reliable digital protection, metering, control and monitoring in an integrated package. M FAMILY

M Family Industrial Systems 2 What is the M Family Applications Features & Benefits Monitoring and Metering User Interfaces M+PC Program Features MIF: Digital Feeder Protection MIV: Digital Voltage/Frequency Protection MIG: Digital Protection for Rotating Machines MIN: Digital Directional Ground Protection MIW: Digital Directional Power and Loss of Field Protection Summary Presentation Overview:

M Family Industrial Systems 3 The M Family Platform consists of the following devices: MIF – Digital feeder protection & back-up protection for transformers, motors and generators MIG – Digital protection for rotating machines including small generators and motors, or large generator in a protection scheme MIN – Digital directional ground overcurrent protection, line protection schemes and as a component for generator, motor and transformer schemes MIV – Digital voltage and frequency protection MIW – Digital directional power protection for small and medium generators What is the M Family?

M Family Industrial Systems 4 Feeder protection at any voltage level Main protection for small generators and motorsMain protection for small generators and motors Backup/auxiliary protection for transformers, motors, generators and busbarsBackup/auxiliary protection for transformers, motors, generators and busbars Can be used alone or in an automation systemCan be used alone or in an automation system Overload protection Automatic transfer equipment Load shedding and restoration schemes Backup directional overcurrent protection Reverse power protection Bus or line synchronism check Generator and network synchronism check Three phase reclosing M Family relays can be used in the following applications: Applications:

M Family Industrial Systems 5 Features & Benefits Safety: UL & CSA approved Reliability: Mature family with Failure Rate below 0.3%/year Delivery: Quick deliveries achieved via automated production cells Simple 3-board architecture:  Main board: CPU, Voltage Inputs, I/O, Power Supply  Secondary board: Current inputs  Front board: HMI (Display, LEDs, RS232) Surface mount board manufacturing technology: reduces size, energy consumption and heat ModBus RTU: Industry standard communication protocol New relays to come: Pilot wire, Phasor Surge, MIF with auto-reclose

M Family Industrial Systems 6 Features & Benefits: The M Family offers users many advanced features including: ! Configurable logic ! Configurable curves ! Flash memory allows easy field software upgrades ! Two settings tables (basic and advanced) ! Modular package allows easy and fast maintenance ! Common modules reduce cost of spare components !Universal AC/DC Power Supply

M Family Industrial Systems 7 !Current, Voltage, Frequency, Thermal Image, Power !Event recorder (24/32 events) !Self-diagnostics !Analog/Digital Oscillography (with M+PC Software) Monitoring and Metering

M Family Industrial Systems 8 DISPLAY KEYPAD !Scrolling LED Dot matrix !Visible in dim lighting or at any angle !Used for programming, monitoring, status, fault diagnosis, and settings !Six LEDs (four of them configurable, one fixed for service and one fixed for trip) !Three button keypad !Rubber keypad dust tight and splash proof !RS232 front communication port User Interfaces: M Family devices feature user-friendly local interfaces:

M Family Industrial Systems 9 !Software runs on Windows ® -based PCs ! Easy viewing of acual values, view/edit settings, view event recorder, view relay status, configure LEDs !Relay firmware programming for upgrades !Download & view Oscillography in Comtrade format !Program I/O logic !Simple software calibration allows extra performance with no extra product cost M+PC Software Features: Windows ® -based software allows easy set-up and monitoring of measured values:

M Family Industrial Systems 10 ! Feeder protection at any voltage level ! Backup/auxiliary protection for transformers, motors, and generators - MIF Feeder Protection MIF Digital Feeder Protection 3 phase and ground time delayed overcurrent (51P, 51G) 4 preconfigured overcurrent curves 1 user configurable overcurrent curve 3 phase and ground instantaneous overcurrent (Hiset and Loset) (50PH, 50PL, 50GH, 50GL) !Open & Close breaker controls Thermal image protection (49) Cold load pickup Configurable inputs and outputs 6 outputs: trip, service required, auxiliary MIF Protection and Control characteristics include: The MIF suits the following applications:

M Family Industrial Systems 11 ! Primary amps reading ! Independent CT ratios for G & N !Complete fault reporting ! Simple software calibration increases accuracy up to 1% !(49) thermal function compatible with other vendors in newer models of MIF !Convenient pullers and rear connectors upgraded to ease extraction and insertion !Single shot recloser (79) built in using flex logic. New MIF Features and Benefits: - MIF Feeder Protection

M Family Industrial Systems 12 ! Over/undervoltage protection and monitoring ! Overvoltage protection for generators ! Undervoltage detection in automatic transfer systems ! Undervoltage/voltage unbalance protection for motors ! Monitoring of lines and busbars for healthy/existing/lack of voltage ! Voltage/frequency load shedding and restoration - MIV Digital Voltage/Frequency Protection MIV Voltage and Frequency Protection The MIV can be used for applications such as:

M Family Industrial Systems 13 Three phase undervoltage protection (27) (Hiset and Loset) MIV includes a separate setting for enabling /disabling the undervoltage unit when a breaker is open Three phase overvoltage protection (59) (Hiset and Loset) Ground overvoltage protection (59N) (Hiset and Loset) Voltage unbalance protection (47) Under/overfrequency protection(81U/81O) Each unit can be independently set as underfrequency or overfrequency. Each frequency unit is supervised by an independently adjustable undervoltage element Multiple Setting Groups Configurable I/O 6 outputs: trip, service required, auxiliary MIV Protection & Control: - MIV Digital Voltage/Frequency Protection The MIV offers advanced Protection and Control functions including:

M Family Industrial Systems 14 - MIG Three-phase protection for rotating machines ! Small Generator protection ! Component in larger generator protection scheme ! Standby/critical power protection main unit ! Small motor protection MIG Digital Protection for Rotating Machines The MIG can be used for applications such as:

M Family Industrial Systems 15 MIG Protection & Control: - MIG Three-phase protection for rotating machines Thermal image protection Unbalance or current reversal Phase, ground time overcurrent (51P, 51N) Phase, ground instantaneous overcurrent (50P, 50N) Undercurrent (37) 4 pre-configured overcurrent curves (ANSI, IEC) Maximum number of starts Locked Rotor 6 outputs: trip, service required, auxiliary Two setting tables

M Family Industrial Systems 16 ! Directional ground protection & control ! Isolated ground or Petersen Coil option ! Backup/auxiliary protection for line schemes ! Component relay for generator, motor and transformer packages - MIN Digital Directional Ground Protection MIN Digital Directional Ground Protection Applications for the MIN include:

M Family Industrial Systems 17 Two ground IOC (high and low) units for grounded systems Two ground TOC (high and low) units for grounded systems Two directional units (67N) for grounded systems Two directional units for ungrounded or Petersen coil systems Configurable breaker failure to open Directional comparison scheme logic (MIN L models) 4 preconfigured overcurrent curves (ANSI or IEC) Configurable I/O 6 outputs: trip, service req’d, auxiliary MIN Protection & Control: - MIN Directional Ground Protection The MIN offers users advanced Protection and Control features including:

M Family Industrial Systems 18 - MIW Directional Power & Loss of Field Relay ! Small and Medium Generators ! Component for complete M050 and M100 systems ! Standby/critical power protection main unit MIW Digital Power Protection The MIW is suitable for the following applications:

M Family Industrial Systems 19 Single universal model for 1 and 5 A CT using just a single terminal. High accuracy current sensors allow extremely wide range (from 1% to 150% of rated current) allowing. Digital software calibration improves accuracy. Advanced phase angle compensation allows high accuracy even in extreme conditions. Single model use for over/under power applications. Easy to use flex logic through M+PC software. Full compatible with URPC standard software. MIW Features & Benefits The MIW’s main features and benefits include: - MIW Directional Power & Loss of Field Relay

M Family Industrial Systems 20 Active Power protection (32) Forward and Reverse (Motoring of generator) Under and Over (Wind generators application) Loss of field excitation (40) Fuse Failure (60) 6 outputs: trip, service required, auxiliary Two setting tables MIW Protection & Control: - MIW Directional Power & Loss of Field Relay The MIW’s Protection and Control features include:

M Family Industrial Systems 21 GE Power Management 215 Anderson Ave., Markham, Ontario Canada L6E 1B3 Web: Tel: Fax: M Family relays provide economical & reliable digital protection, metering, control and monitoring in one integrated package. MIF – Feeder & auxiliary protection for transformers, motors and generators MIG – Protection for small generators and motors, and component in large generator protection schemes MIN – Protection for directional ground, auxiliary line schemes, and as a component for generator, motor and transformer schemes MIV – Voltage and frequency protection MIW – Power protection for small and medium generators, and as a component for M050 and M100 system M Family Summary: