Novel 3-D Sample Plate using Monolithic Capture Media in Collimated-Hole Structures for Interfacing High Capacity Separations with MALDI-TOF Poster Number.

Slides:



Advertisements
Similar presentations
Chromatography Components stationary phase (eg., solid matrix) mobile phase (eg., solvent) solute Solutes which interact differently with the stationary.
Advertisements

Size Exclusion Chromatography
Foundation GPC Training Course Theory. Nomenclature Gel Permeation ChromatographyGPC Size Exclusion ChromatographySEC Gel Filtration ChromatographyGFC.
HPLC 1. Introduction 1.Introduction CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution.
1 1. Introduction H: High P : Performance (Pressure) L : Liquid C : Chromatography GC : Gas chromatography TLC: Thin layer chromatography IC : Ion chromatography.
KROMATOGRAFİ Sedat Türe. HPLC Liquid Chromatography.
Oligonucleotide analysis by Linear MALDI-TOF mass spectrometry Stephen J. Hattan , Kenneth C. Parker, Marvin L. Vestal; SimulTOF Systems, 60 Union Ave,
Gradient Manipulation and 1.8 µm LC Columns for High Resolution Analysis of Herbal Supplements John W Henderson Jr, Thierry Faye, Ulrik Witteg, Maureen.
Proteored Multicentric Experiment 8 (PME8) Quantitative Targeted Analysis in Proteomics. An Assesment Study (QTAPAS) ProteoRed WG1-WG2 Meeting Pamplona,
Chapter 32 HIGH-PERRORMANCE LIQUID CHROMATOGRAPHY High-performance liquid chromatography (HPLC) is the most versatile and widely used type of elution chromatography.
Presented by Meng Shi The C holesterol in plasma was a important factor to lead Thrombus.
Proteomics The proteome is larger than the genome due to alternative splicing and protein modification. As we have said before we need to know All protein-protein.
Column Chromatography. Types of columns: 1- Gravity Columns: The mobile phase move through the stationary phase by gravity force. 2- Flash Columns (Air.
Intro to Chromatographic Separations Chap 26. Originally based on separation and identification by color Originally based on separation and identification.
FIGURE 5. Plot of peptide charge state ratios. Quality Control Concept Figure 6 shows a concept for the implementation of quality control as system suitability.
MALDI-TOF-TOF with High Resolution Precursor Selection and Multiplexed MS-MS Poster Number ThP 618 Kevin Hayden, Stephen C. Gabeler, Mark Dahl and Marvin.
B IOCHEMICAL INSTRUMENTAL ANALYSIS -11 Dr. Maha Al-Sedik.
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
Tryptic digestion Proteomics Workflow for Gel-based and LC-coupled Mass Spectrometry Protein or peptide pre-fractionation is a prerequisite for the reduction.
Chromatography Desalting and Affinity. Chromatography Technique to separate components of a mixture by passing them through a matrix. –A solvent is used.
Comparison of chicken light and dark meat using LC MALDI-TOF mass spectrometry as a model system for biomarker discovery WP 651 Jie Du; Stephen J. Hattan.
Wilkes University - CHM D Gas Chromatography (or 3D with MS Detector) A powerful separations tool for complex volatile mixtures of heat-stable samples.
Chromatography Dr.Tawfeq A. Al-Howiriny Associate Professor
Chapter 6 - Chromatography
High Performance Liquid Chromatography
Chromatography Chapter 6.
Marvin Vestal and Kevin Hayden Virgin Instruments Corp. Sudbury, MA
Method conditions Excellent resolution and fast run times 2 x OligoPore, 4.6 x 250 mm columns gave excellent oligomeric resolution for the PS 580 sample.
Tissue Imaging by 5 kHz High-Performance MALDI-TOF Poster Number TP191 Christina Vestal 1, Kenneth Parker 1, Kevin Hayden 1, George Mills 1, Marvin Vestal.
INTRODUCTION TO CHROMATOGRAPY
-Aluminum housing with o-ring seal allows for washing (salt removal), plate cleaning and regeneration enabling for multiple use -Sample elution for MS.
DEVELOPMENT OF A RP-HPLC METHOD FOR THE DETERMINATION OF METFORMIN IN HUMAN PLASMA.
CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution coefficient.
Marvin Vestal and Kevin Hayden SimulTOF Systems
A new "Molecular Scanner" design for interfacing gel electrophoresis with MALDI-TOF ThP Stephen J. Hattan; Kenneth C. Parker; Marvin L. Vestal SimulTof.
High Performance Liquid Chromatography. The chromatogram is a record of detector output Vs time as the analyte passes through the chromatography.
A versatile MALDI target plate based on polymer-filled reticulated vitreous carbon foam ThP Stephen J. Hattan ; Jie Du; Kenneth C. Parker VIC Instruments.
Improving the Detection of Hydrophilic Peptides for Increased Protein Sequence Coverage and Enhanced Proteomic Analyses Brian S. Hampton 1 and Amos H.
HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC). HIGH PERFORMANCE LIQUID CHROMATOGRAPHY High Performance Liquid Chromatography (HPLC) is one of the most.
LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY
1 Gas Chromatography Lecture Liquid Stationary Phases In general, the polarity of the stationary phase should match that of the sample constituents.
Introduction to Chromatography. Introduction Chromatography permit the scientist to separate closely related components of complex mixtures. In all chromatographic.
HPLC.
Chapter 28 High Performance Liquid Chromatography.
Biochemical instrumental analysis - 11 Dr. Maha Al-Sedik 2015 CLS 332.
Liquid Chromatography 2: New Technology Lecture Date: April 3 rd, 2007.
HPLC.
Selling Restek LC Solutions for Analytical Scale Laboratories Rick Lake Product Line Manager Liquid Chromatography x 2379
A bi-functional glass membrane designed to interface SDS-PAGE separations of proteins with the detection of peptides by mass spectrometry MP 006 Kenneth.
Lecture 8 Peak Parameters and Quantitative chromatography
Determination of metformin in urine (by Liquid Chromatography LC)
Instrumental Analysis (I) HPLC Tutorial 8. Graded presentation Students in groups of 4-5 individuals are asked to prepare a presentation (weight=5% of.
Downloaded from کروماتوگرافی CHROMATOGRAPHY Downloaded from
이 장 우. 1. Introduction  HPLC-MS/MS methodology achieved its preferred status -Highly selective and effectively eliminated interference -Without.
Biochemical instrumental analysis - 9 Dr. Maha Al-Sedik 2016 CLS 332.
High Performance Liquid Chromatography. What is HPLC ? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube.
Bioseparation II Chromatography Techniques. Chromatography Most widely used purification technique used for biomolecules. Most widely used purification.
H M Arif Ullah, Hye Jin Chung*
Chem. 133 – 5/2 Lecture.
Chromatography- TLC & HPLC
2 Dimensional Gel Electrophoresis
Chromatographic separation
HPLC.
Pierre P. Massion, MD, Richard M. Caprioli, PhD 
Shotgun Proteomics in Neuroscience
High-Performance Liquid Chromatography
Chromatography is a technique in which the components of a mixture are separated based on The differences in rates at which they are carried through a.
Transferring LC-UV to LC-MS.
Chromatography is a technique in which the components of a mixture are separated based on The differences in rates at which they are carried through a.
High-Performance Liquid Chromatography
Presentation transcript:

Novel 3-D Sample Plate using Monolithic Capture Media in Collimated-Hole Structures for Interfacing High Capacity Separations with MALDI-TOF Poster Number TP 060 Stephen Hattan, Marvin Vestal Virgin Instruments Corporation Sudbury, Massachusetts USA Overview/Introduction: 3 2 -Novel MALDI targets are being developed that use collimated hole structures (CHS) combined with monolithic chromatography media to enable capture & concentration of sample and serve as a direct interface between the mass spectrometer and different separation schemes -HPLC, electrophoresis and tissue imaging- -Plate construction, sample deposition (LC) and sample elution are presented -Results of capacity and LC interface at 15 and 50 μ L/min separation speeds are presented 5 Figure 3: Prototype LC deposition System -X Y control of solvent capillary -Tip seals with plate surface -column pressure forces column effluent through discrete locations on CHS plates. 4 Figure 1: CHS plates: Row 1: 100, 675 and 384 wells plate of 1.5, 3 and 10 mm thickness respectively constructed in metal and plastic designed for modes of discrete sample deposition such as LC or robotic and hand spotting. Row two shows glass μ-channel CHS plate (25μm holes) designed for interface with gel and tissue applications. 1 Figure 2: Plate Construction: -styrene/divinylbenzene based polymers for reversed phase capture media of protein/peptides -monomer solutions are injected into tetrafluoroethylene molds -polymerization is thermally initiated -Excess polymer is shaved to a level coincident with the plate substrate (metal, plastic, glass). -ratio and constitution of dilution solvent(porogens) are used to tailor pore-size/flow properties -Sample application/analysis occur on the polymer surface. Figure 4: Prototype Elution System -uses pressure on reservoir of eluent residing on one side of the plate to force the liquid through all holes simultaneously. -enclosed chamber with exhaust fan on opposite side of plate enhances solvent evaporation and matrix crystallization. Figure 5 LC Results: -3D plots of signal intensity as function of surface location from 1pmol BSA digest LC separation Conditions: 0.5 mm column ID C-18 (eksigent), 15uL/min, 5-45%ACN gradient (50min), dwell time 30s/spot 10x10 CHS plate (Fig. 1 top left) -Frame A: extracted ion chromatogram (EIC) all peptides from Da. -Frame B: EIC of three individual peptides (927,1479,1725 Da) -Frame C: EIC of 379Da ACCH matrix dimer. Figure demonstrates the ability of the CHS plates to capture/concentrate sample without loss of chromatographic resolution and uniform sample elution. Figure 6: Comparison with conventional 2D plate: -Identical 1hr separation of 1pmol BSA at 15uL/min flow spotted at 5s intervals on a 2D surface and 20s intervals on a CHS plate. -Left frames shows the EIC and max-intensity spectrum of 1479Da peptide from each run (CHS top:2D bottom). -Right frames are blow-ups of the EIC region of interest. -Right top: raw signal intensity 13x increase in intensity -Right bottom: signal intensity normalized against a 1042Da internal standard (matrix addition) demonstrates 32x increase in signal intensity Based dwell time and spot dimensions a 36x increase in signal was calculated therefore the above results indicate near 100% sample recovery. 6 7 Figure 7: Capacity study: -plots from different loading schemes aimed at determining capacity of CHS plate with ~5 μ L void volume. -Plot A: dilution series of different conc. loaded in some volume as not overwhelm the void volume of well shows ~ 8pmol load capacity limited primarily by analyte/matrix ratio/ ionization efficiency -Plot B Same sample different load volume --void volume exceeded-- Limited by binding capacity of CHS wells ~2.5 pmol of digested protein. -Binding capacity will vary with well dimensions fmol TIC (x1000) 1479 select fmol Area 1479 Figure 8: Four Identical, 25 min, 50 μ L/min LC separation on single CHS plate Conditions: 50x1mm, 200Å, C-18 5μm, Higgins Anal., 0-45% ACN (25 min) 50μL/min flow, dwell time/spot 10s -overlay of EIC from 12 mid-intensity range peptides plotted as ratio against1042internalstandardand show and average relative standard deviation of 22%. -5pmol of BSA digest run in series and spotted on a single 675 well CHS plate (Fig. 1 top middle) -separations conditions represent a X increase in flow rate/sample load and capture over conventional LC-MALDI schemes performed on 2D plates. -relative large sample load, high speed, reproducible separation afforded by CHS plates. EIC DaEIC 3 individual peptidesEIC matrix A B C Conclusions: -Novel 3-dimensional MALDI target that captures and concentrates peptide/protein sample and serves as a direct interface between separation and mass spectrometer -Plates allow for higher load capacity (potentially 100s μ g to mg quantity) and higher flow (100s μ L- mL/min) separations that should enable dramatic increase in the detection levels of lower concentration proteins/peptides in complex proteomic mixtures. -Plates are designed to be reusable with current prototypes easily withstanding analyses (like typical LC columns). -Presentation focuses on the reversed phase LC-MALDI interface because of its near ubiquitous capture of peptide material; however, plates focused on affinity capture (ie. glyco-capture) and studies focused on direct interface of Gel and tissue sample preparation schemes with MALDI are underway. Acknowledgement: Recognition and thanks is deserved for the entire Virgin Instruments staff for significant contributions to this project; Christina Vestal, Kevin Hayden, Roger Voyer, Joseph Fitzpatrick, Joseph Valentine “as in Valentine’s Day”, George Mills, Steve Gabeler, Matthew Gabeler and Mark Dahl. Funding: This work was supported by SBIR Grant GM ~2x2” 100 well 5x5” 675 wellStd. 384 well μ - Channel 2x2” 10fmol-10pmol dilution series different sample Conc. loaded in identical volumes 10fmol-7.5pmol conc. series identical sample loaded in different volumes 32x increase 13x increase