Pore Detection in Small Diameter Bores The University of Michigan, Ann Arbor NSF Engineering Research Center for Reconfigurable Manufacturing Systems.

Slides:



Advertisements
Similar presentations
Bio-Rad Labs. Chromatic Aberration Sources and Measurement.
Advertisements

Simulation of Fibrous Scaffold Optimal Distribution by Genetic Algorithm Presentation : D. Semnani ICSIP 2009, Amsterdam Isfahan University of Technology.
Design Project MAK112E Computer Aided Technical Drawing Dr C Erdem – 9.30 Project work (meeting) Search in internet, patents and standards.
SXC meeting SRON, July 19-20, SXC meeting 19-20/07/2007 Alignment Positioning of mirror with respect to detector (internal). Positioning of total.
Blizard Advanced Light Microscopy club Making friends with your microscope.
Deriving Lights from Pixels Presented By: WAIL ALI EL EBEEDY By: By: Web Address: ArchitectureWeek - Tools - Deriving Lights from Pixels _0528.htm.
Logging and Replay of Go Game Steven Davis Elizabeth Fehrman Seth Groder.
Group S3. Lab Session 5 Following on from our previous lab session decided to find the relationship between Disparity vs Camera Separation. Measured Disparity.
Conceptual Design Review Senior Design University of Idaho College of Engineering.
Primary Goals Fully develop vision system for Wunderbot IV autonomous robot Adapt it specifically for June 2008 Intelligent Ground Vehicle Competition.
Three-Dimensional Concepts
Ch 25 1 Chapter 25 Optical Instruments © 2006, B.J. Lieb Some figures electronically reproduced by permission of Pearson Education, Inc., Upper Saddle.
Introduction to Operation of the XL- 30 Scanning Electron Microscope Tutorial # 2 Introduction to Operation and Imaging.
Photography Parts of a Camera. Aperture size (or width or diameter) of the opening of a lens diaphragm inside a photographic lens regulates the amount.
Magnus Pro Training Presentation
1.1 Intro to the microscope and Calculating cell size.
SL Introduction to Optical Inspection1. Introduction to Optical Inspection Helge Jordfald Sales & Marketing Manager Tordivel AS – Norway.
Reconfigurable Inspection Machine (RIM). NFS Engineering Research Center for Reconfigurable Manufacturing Systems College of engineering, University of.
Prepared by Mahmoud F. Elbatta Ahmad Alyazgi Amjad Alaskary Akram abo Twahina Roshdi tambora.
DELTA Quadrant Tuning Y. Levashov, E. Reese. 2 Tolerances for prototype quadrant tuning Magnet center deviations from a nominal center line < ± 50  m.
The University of Michigan, Ann Arbor Engineering Research Center for Reconfigurable Manufacturing Systems TA-3 Projects In-Process Metrology.
Optical Design Work for a Laser-Fiber Scanned
Real Time Ultrasound Camera for Industrial Applications Bob Lasser Imperium, Inc. Beltsville, MD.
Adam Dick M.Sc.F. Candidate, University of New Brunswick 2007 Western Mensurationists Meeting June 24-26, 2007 Kelowna, B.C.
Dimensioning (WEEK 2).
NSF Engineering Research Center for Reconfigurable Manufacturing Systems University of Michigan College of Engineering In-Line Engine Valve Seat Inspection.
Study of Surface Porosity
PHYS 1442 – Section 004 Lecture #22-23 MW April 14-16, 2014 Dr. Andrew Brandt 1 Cameras, Film, and Digital The Human Eye; Corrective Lenses Magnifying.
IPD Technical Conference February 19 th 2008 Friction Roller Identification Jack Weatherford Hermitage Automation & Controls.
Detecting Pedestrians Using Patterns of Motion and Appearance Paul Viola Microsoft Research Irfan Ullah Dept. of Info. and Comm. Engr. Myongji University.
1 NSF Engineering Research Center for Reconfigurable Manufacturing Systems University of Michigan College of Engineering Cylinder Bore Inspection Engineering.
IPD Technical Conference February 19 th 2008 Application: Juice Box Web Slitting Application – Monitor and Verify Crease to Knife Cut Edge Position. Distributor:
Sensing for Robotics & Control – Remote Sensors R. R. Lindeke, Ph.D.
 When light strikes the surface of an object  Some light is reflected  The rest is absorbed (and transferred into thermal energy)  Shiny objects,
Microscope Lab. Mrs. Orwar’s sure fire way to find an image every time! 1.Start on low power (red objective) 2.Place your slide centered over the light.
LNGS 4 Jul 2006 INFN BO1 Grain analysis with High-Resolution microscope  An High Resolution microscope was developed in parallel with the ESS and is working.
Forward-Scan Sonar Tomographic Reconstruction PHD Filter Multiple Target Tracking Bayesian Multiple Target Tracking in Forward Scan Sonar.
NSF Engineering Research Center for Reconfigurable Manufacturing Systems University of Michigan College of Engineering Reconfigurable System for Turbine.
Supervisor: Prof K. Abramski States of polarization of chosen fiber elements.
How to startpage 1. How to start How to specify the task How to get a good image.
Real-time Parathyroid Visualization System for use in Endocrine Surgery Oral Presentation 3 Feb 16, 2010 BME 273 Senior Design Group 1 Isaac Pence Advisors:
Microscope Basics.
IPD Technical Conference February 19 th 2008 Application: Pipette Measurement and Flash Inspection. Distributor: CPU Automation Engineer: Mike Bray.
Magnification, Working Distance, Resolution and Field of View.
1 4. Principles of Dimensioning This week you will learn dimensioning. The steps to follow are: Functional & Non-functional Dimensions Principles of Dimensioning.
 Mirrors that are formed from a section of a sphere.  Convex: The reflection takes place on the outer surface of the spherical shape  Concave: The.
Revision of terminology and drawing a Ray diagram
1 of 175 Focus 3D X 130 and X 330 Laser Scanners SCENE 5.3 September 2014.
Real-time Parathyroid Visualization System for use in Endocrine Surgery Oral Presentation 4 March 18, 2010 BME 273 Senior Design Group 1 Isaac Pence Advisors:
SL/BI 16/05/1999DIPAC’99 -- JJ Gras -- CERN SL/BI -- Adaptive Optics for the LEP 2 SR Monitors G. Burtin, R.J. Colchester, G. Ferioli, J.J. Gras, R. Jung,
Microscope 101 Always carry a scope with two hands: One on the arm and one under the base.
Based on an Article Published 12/2011 by: En Hong, Honogwei Zhang, Reuven Katz, John S.Agapiou Presented by: Vadim Tutaev & Boris Sheendlin.
7-1 Chapter 7 THE MICROSCOPE. 7- Criminalistics, 10e Richard Saferstein © 2011, 2007, 2004, 2001, 1998, 1995 Pearson Higher Education, Upper Saddle River,
Logan Regional Family History Center Microfilm/Fiche Viewer/Scanner Prepared by Robert Curry 11/22/2010.
Outline Sample preparation Instrument setting Data acquisition Imaging software Spring 2009AFM Lab.
© Sierra College Astronomy Department1 Photographing the Sun and Moon (II-C) Prime Focus Photography.
11/25/03 3D Model Acquisition by Tracking 2D Wireframes Presenter: Jing Han Shiau M. Brown, T. Drummond and R. Cipolla Department of Engineering University.
Non-Contact Inspection of Internal Threads of Machined Parts
ΜD Series 9 LFB --- CYCLOPS. Provides technical support for sister companies including robotic system design and fabrication, equipment maintenance Founded.
Four OTRs for ATF2 OTR History Current OTR setup New OTR design.
Chapter 7 THE MICROSCOPE.
NEW UPGRADE TO THE APS MAGNETIC FIELD INTEGRAL MEASUREMENT SYSTEM
Melissa Crawford, Renjie Zhou, and Prof. Lynford Goddard
MultiView 400™ Product Presentation Nanonics MultiView 400™
Three-Dimensional Concepts. Three Dimensional Graphics  It is the field of computer graphics that deals with generating and displaying three dimensional.
Preliminary Design Review
Paper Synopsis: Lens Centering using the Point Source Microscope Robert E. Parks by Wenrui Cai Opti521.
Inline System to Detect Hydrates, Wax and Sand Thomas M. Canty PE J. M
Chapter 7 THE MICROSCOPE.
Presentation transcript:

Pore Detection in Small Diameter Bores The University of Michigan, Ann Arbor NSF Engineering Research Center for Reconfigurable Manufacturing Systems

University of Michigan College of Engineering ERC Presentation Format # 2 Introduction Pores above 500 micron inside small bores may cause leakage and other problem Specifications: Dimension: Φ 5-15 mm L mm ( May be stepped and discontinuous) Material: Aluminum Pore Size: Φ < 1 mm Surface: Glossy Φ15mm Φ5mm mm

NSF Engineering Research Center for Reconfigurable Manufacturing Systems University of Michigan College of Engineering ERC Presentation Format # 3 Project goals 1.In-line inspection of the inner surface of small bores of power train parts 2.Detect and locate pores lager than 1mm diameter inside a small bore

NSF Engineering Research Center for Reconfigurable Manufacturing Systems University of Michigan College of Engineering ERC Presentation Format # 4 Progress Stage 1. Background investigation (April, 2007 ) Stage 2. Preliminary study (May, 2007) Stage 3. System integration (June, 2007) Stage 4. Image processing and porosity analysis (July-Now, 2007)

NSF Engineering Research Center for Reconfigurable Manufacturing Systems University of Michigan College of Engineering ERC Presentation Format # 5 Sight Pipe System X Y motion stage Z rotary stage CCD Sight Pipe Sample Side and top view of the system

NSF Engineering Research Center for Reconfigurable Manufacturing Systems University of Michigan College of Engineering ERC Presentation Format # 6 “Paper Bore” image 13 mm Diameter Real Bore image The shadow lines appears Scanning results

NSF Engineering Research Center for Reconfigurable Manufacturing Systems University of Michigan College of Engineering ERC Presentation Format # 7 Scanning result after alignment After alignment Before alignment Large intensity variance small intensity variance

NSF Engineering Research Center for Reconfigurable Manufacturing Systems University of Michigan College of Engineering ERC Presentation Format # 8 Alignment of Camera and motion stage Step1- Focus the camera onto a target point at a close distance and center the target using linear adjustments. Step2- Use motion stage to move the camera to the further distance and center the target using angular adjustments. Step3- Repeat steps 1 and 2 until the targets are centered in the same position.

NSF Engineering Research Center for Reconfigurable Manufacturing Systems University of Michigan College of Engineering ERC Presentation Format # 9 Aligning the Bore axis Step1-Focus on front of the bore and find the center of the circular opening. Step2-Focus on the back of the bore and find the center of a circular ring. Step3-Align angular and linear positioning of the bore until the two reference circles are centered with the camera.

NSF Engineering Research Center for Reconfigurable Manufacturing Systems University of Michigan College of Engineering ERC Presentation Format # 10 Straightness and angular tolerance for aligning the Bore The bore must be properly aligned to provide a low intensity variance for the unwrapping zone. –Straightness should be within ~0.18 mm in each direction –Angular error should be within ~670 arcsecs

NSF Engineering Research Center for Reconfigurable Manufacturing Systems University of Michigan College of Engineering ERC Presentation Format # 11 Current Work 1.Software interface improvement  User-Friendly interface  Well organized program with clear comments 2.Porosity analysis using Labview –Detect pores with different size –Indicate the location of the pores –Filter the pores as needed (By size, location and so on) –Provide statistic table 3.Redesign mounting structure for the sight pipe system to add one degree of freedom in vertical direction

NSF Engineering Research Center for Reconfigurable Manufacturing Systems University of Michigan College of Engineering ERC Presentation Format # 12 Some Algorithms Sight Pipe + IMAQ image processing: Finding center polar unwrapping stitching Motion control : Magnification = real width of line / pixel width of line*Pixel size Total time of Scan = scanning distance/ motion velocity Motion velocity= Width of sampling zone*Pixel size*Magnification / Sampling period Finding the Pore: Threshold Particle Filter Particle Analysis

NSF Engineering Research Center for Reconfigurable Manufacturing Systems University of Michigan College of Engineering ERC Presentation Format # 13 Image Processing 1.A background correction threshold is applied to the entire image. –Background correction breaks the image up into smaller regions and searches for the darkest areas in each image. 2.The particles are then put through a particle filter based on the major axis of the best fit ellipse. 3.The image saved with particle information are loaded into a screen that allows the user to easily see the pores and their location based on the filter been chosen.

NSF Engineering Research Center for Reconfigurable Manufacturing Systems University of Michigan College of Engineering ERC Presentation Format # 14 MINI CCD updating 51 degree field of view with normal lens Inside view of a bore ( 13 & 30 mm diameter)

NSF Engineering Research Center for Reconfigurable Manufacturing Systems University of Michigan College of Engineering ERC Presentation Format # 15 Fiber illumination for the MINI CCD Fiber MINI CCD

NSF Engineering Research Center for Reconfigurable Manufacturing Systems University of Michigan College of Engineering ERC Presentation Format # 16 Next Steps Optimize the pore detection algorithms Improve the mounting structure of the sight pipe system Increasing the optical magnification to get higher resolution Upgrading the CCD and DAQ device for higher speed if necessary Continue the Mini CCD research