R. Hui Photonics for bio-imaging and bio- sensing Rongqing Hui Dept. Electrical Engineering & Computer Science, The University of Kansas, Lawrence Kansas.

Slides:



Advertisements
Similar presentations
Absorption of photon elevates chromophore to excited state.
Advertisements

Pulsed Fiber Laser Autocorrelator
Multi-photon Fluorescence Microscopy. Topics Basic Principles of multi-photon imaging Laser systems Multi-photon instrumentation Fluorescence probes Applications.
D e t e c t o r s f o r H P L C.
The LaRC Fiber Draw Tower Presented by Stan DeHaven.
Microscopy Outline 1.Resolution and Simple Optical Microscope 2.Contrast enhancement: Dark field, Fluorescence (Chelsea & Peter), Phase Contrast, DIC 3.Newer.
Optical methods for semiconductor characterization Guillaume von Gastrow.
Sergey Kucheryavski Raman spectroscopy Acquisition, preprocessing and analysis of spectra.
Lasers and Confocal. Laser Acronym: Light Amplification by Stimulated Emission of Radiation Ordinary light emission: Comes from spontaneous decay of excited.
Laser Anemometry P M V Subbarao Professor Mechanical Engineering Department Creation of A Picture of Complex Turbulent Flows…..
Основы оптического имиджинга в нейронауках Алексей Васильевич Семьянов.
Fluorescence microscopy – Principle and practical consideration Hiro Ohkura.
Short pulses in optical microscopy Ivan Scheblykin, Chemical Physics, LU Outline: Introduction to traditional optical microscopy based on single photon.
Confocal & Two-photon Microscopy. Contents 1.Two-Photon Microscopy : Basic principles and Architectures 2. Resolution and Contrast in Confocal and Two-Photon.
1 Optical Fibre Amplifiers. 2 Introduction to Optical Amplifiers Raman Fibre Amplifier Brillouin Fibre Amplifier Doped Fibre Amplifier.
Optical Coherence Tomography Zhongping Chen, Ph.D. Optical imaging in turbid media Coherence and interferometry Optical coherence.
Fluorescence. Topics Sensitivity (nM-pM) –Contrast UV-vis measurements Derivatization Laser-Induced Fluorescence.
Atomic Absorption Spectroscopy (AAS)
Development of a thermal cooling system for a PMT (Photo Multiplier Tube) Summer Researcher Yasmine Salas Colorado State University Advisor: Dr. Julia.
FLOW CYTOMETRY Dr. MOHAMMED H SAIEMA LDAHR KAAU FACULTY OF APPLIED MEDICAL SCIENCES MEDICAL TECHNOLOGY DEPT. 2 ND YEAR MT INSTROMINTATION EXT
Fiber-Optic Communications
Atomic Absorption Spectroscopy Elemental analysis Dissolved metals Source –Hallow Cathode Lamp –Cathode of specific element Sample –Acetylene-air flame,
STUDY OF AMPLIFICATION ON ERBIUM DOPED FIBER AMPLIFIER Lita Rahmasari, Assoc. Prof. Dr. Yusof Munajat, Prof. Dr. Rosly Abdul Rahman Optoelectronics Laboratory,
Study of Protein Association by Fluorescence-based Methods Kristin Michalski UWM RET Intern In association with Professor Vali Raicu.
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
Nanoscale Cr 4+ – Doped Olivine Crystallites in Glass-Ceramics for NIR Optical Amplifiers and Lasers By: Fayette Colon Mentor: Mikhail Sharonov Assistant.
Illumination and Filters Foundations of Microscopy Series Amanda Combs Advanced Instrumentation and Physics.
Photo-Thermal Coherent Confocal Microscope This work is supported in part by the Center for Subsurface Sensing and Imaging Systems, under the Engineering.
IPC Friedrich-Schiller-Universität Jena 1 Reduction of out of focus light  Excitation light excites fluorescence more or less within the whole sample.
RamanRaman. Scattering Tyndall scattering – if small particles are present During Rayleigh scattering (interaction of light with relatively small molecules)
Dispersive spectrometers measure transmission as a function of frequency (wavelength) - sequentially--same as typical CD Interferometric spectrometers.
Dr Gihan Gawish Hydrodynamic focusing is a technique used to provide more accurate results from flow cytometers or Coulter counters for determining the.
 Flow cytometry is a technique for counting, examining, and sorting microscopic particles suspended in a stream of fluid.
Optical Characterization methods Rayleigh scattering Raman scattering transmission photoluminescence excitation photons At a glance  Transmission: “untouched”
FEMTOSECOND LASER FABRICATION OF MICRO/NANO-STRUCTURES FOR CHEMICAL SENSING AND DETECTION Student: Yukun Han MAE Department Faculty Advisors: Dr. Hai-Lung.
Epi-illumination is form of Kohler Illumination:
Two-Focus Fluorescence Correlation  Spectroscopy: A New Tool for Accurate and Absolute Diffusion Measurements Jörg Enderlein et al., ChemPhysChem, 8, 433–443.
Single Molecule Spectroscopy (SMS) 2010/6/9 Miyasaka Lab. Iida Atsushi.
Sowmya Vasa, Umar Alqasemi, Aditya Bhargava. Objectives This paper aims in bringing out a novel light microscopy method called Focal Modulation Microscopy.
Functional cellular imaging by light microscopy MICROSCOPIES.
Developments in Imaging Technology and Staining Techniques Unit C: Section 1.3 Science 10.
Pursuing the initial stages of crystal growth using dynamic light scattering (DLS) and fluorescence correlation spectroscopy (FCS) Takashi Sugiyama Miyasaka.
1.Stable radiation source 2.Wavelength selector 3.Transparent sample holder: cells/curvettes made of suitable material (Table 7- 2) 4.Radiation detector.
Optical Amplifiers By: Ryan Galloway.
1 Multilayer optical bit-oriented memory. 2 Abstract The advent of blue-laser (405nm) optical storage in the form of BD, HD DVD, holographic memories,
Designing a Microscopy Experiment Kurt Thorn, PhD Director, Image from Susanne Rafelski, Marshall lab.
Date of download: 5/28/2016 Copyright © 2016 SPIE. All rights reserved. Confocal to multiphoton conversion. (a) Schematic of system adaptation. The near.
James A Germann, Brian K Canfield, Jason K King, Alexander Terekhov, Lloyd M Davis.
Imaging.
Reporter: Chien-Chung Tsai
Date of download: 7/5/2016 Copyright © 2016 SPIE. All rights reserved. Spatial light modulator-two-photon microscope (SLM-2PM) scheme: (1) Ti:Sa laser.
Lasers and Confocal.
UNIT-3 ADVANCES IN METROLOGY
Optical Non-Invasive Approaches to Diagnosis of Skin Diseases
Mingyun Li & Kevin Lehmann Department of Chemistry and Physics
Flowcytometry.
Introduction to Optoelectronics Optical communication (3) Optical components Prof. Katsuaki Sato.
Lightwave Engineering
transmitted radiation
Volume 84, Issue 6, Pages (June 2003)
Optical Non-Invasive Approaches to Diagnosis of Skin Diseases
Molecular Dynamics in Living Cells Observed by Fluorescence Correlation Spectroscopy with One- and Two-Photon Excitation  Petra Schwille, Ulrich Haupts,
Vital imaging: Two photons are better than one
LIGHT MICROSCOPY variations
Sapun H. Parekh, Young Jong Lee, Khaled A. Aamer, Marcus T. Cicerone 
Complex Nanophotonics
The Art of Flow Cytometry
Flow Cell Injector Tip Fluorescence signals Focused laser beam Sheath
Volume 95, Issue 8, Pages (October 2008)
Flow Cell Injector Tip Fluorescence signals Focused laser beam Sheath
Presentation transcript:

R. Hui Photonics for bio-imaging and bio- sensing Rongqing Hui Dept. Electrical Engineering & Computer Science, The University of Kansas, Lawrence Kansas

R. Hui Laser scanning confocal microscope Photo detector Detector pin-hole Focal plane Laser source Out of focus Lens Beam splitter 3-demensional translation stage Fluorescently labeled tissue Advantages: out-of-focus background can be removed by the small aperture in front of the detector Allows 3-D imaging Disadvantages: Photon bleach because the use of visible light (400 – 600 nm) sensitive to background light

R. Hui Concept of Two-photon excitation ~400nm Fluorescence Ground state Excited state One photon excitation ~800nm Fluorescence Ground state Excited state ~800nm Two photon excitation

R. Hui Two-photon microscopy Optical power spreading Better focus Use near infrared wavelength -less photon bleach and less scattering when penetrating through tissue Detection at wavelength far away from excitation – no background noise due to Raman and direct fluorescence Two-photon excitation is proportional to the square of the power density – smaller focus point, minimum off- focus excitation and no need of a pin- hole in front of the detector

R. Hui Why two-photon microscopy is not popular so far ? n Requires very high peak optical power because of the low 2-photon excitation efficiency n Ti:Sapphire lasers have to be used to provide kW level peak optical power: big in size, very expensive, needs tweaking from time to time n Difficult to deliver femtosecond optical pulse from laser to microscope

R. Hui High power femtosecond fiber laser Pump Saturable absorption mirror Faraday rotator Partial reflection Doped MM fiber Popular wavelengths: 1550nm: Erbium doped fiber 1064nm: Ytterbium doped fiber 780nm: Frequency-doubling the output of 1550nm fiber laser using periodically polled LiNbO3 (PPLN)

R. Hui Enabling technologies n Improvement in rear-earth doped optical fibers n Excite only the fundamental mode of a doped multi- mode fiber: breakthrough power limitations n Use Faraday rotator: eliminate polarization sensitivity n Saturable absorption mirror: pulse shaping

R. Hui Femtosecond fiber laser at 780nm (fixed wavelength)

R. Hui Highly nonlinear Photonic crystal fiber n Periodic air holes in the core n Very high nonlinearity n Zero-dispersion wavelength shifted to 700nm n Support Raman shifted soliton in NIR

R. Hui Wavelength shift using photonic crystal fiber Femtosecond fiber laser Optical spectrum analyzer Mechanical translation stage 6m photonic crystal fiber

R. Hui Pulse wavelength shift due to power change (from 1mW to 4mW average power) Power spectral density (linear) Wavelength (nm) Fundamental soliton condition:

R. Hui Pulse wavelength shift due to power change (Computer simulation)

R. Hui Multi-color two-photon fluorescent microscopy using TDM 780 nm fiber laser PCF-1 AOM Sample Detector Register nm fiber laser AOM PCF-2 Digital control Microscope Source Memory & signal processing 2 n Filter Control and signal processing Pulse compressor Fig.3. Block diagram of the proposed wavelength switchable two-photon equipment

R. Hui Absorption and emission spectrum of Alexa fluorescent dyes

R. Hui Measured Two-photon fluosphere images At depth 1 At depth 2

R. Hui Radial and axial two-photon intensity profiles (excited at 780nm)

R. Hui Radial and axial two-photon intensity profiles (excited at 920nm)

R. Hui Focal volume area Observation volume area Fluorescent correlation spectroscopy (FCS) (measured at 780nm)

R. Hui Bio-assay based on flow cytometry Count and analyze individual particles in a fluid channel

R. Hui Silicon substrate Spin-coat SU-8 photo-resistor Photo-mask UV Silicon substrate Flow-cytometer on chip: Create channels

R. Hui Silicon substrate Spin-coat second layer SU-8 Photo-mask UV Silicon substrate Flow-cytometer on chip: Create grooves

R. Hui Silicon substrate Molding PDMS

R. Hui Picture of a flow chip Input fiber Detection fiber Buffer Sample

R. Hui Demonstration of sheath flow Buffer Sample Sheath creation

R. Hui Measurement Laser Fluid pump (water) Fluid pump (sample) Fluid pump (water) PMT D/A converter Computer Waste

R. Hui Measurement passing diluted yeast solution through the cytometer Time (s) PMT output (V)

R. Hui Clean water 4 times increase of yeast concentration between each measure

R. Hui 10log(N) 10log(V) Cumulative summation histogram V: threshold n: number of counts