Electrical hazards are present in all laboratories. Adherence to all electrical safety standards is essential in preventing electrical accidents.

Slides:



Advertisements
Similar presentations
Hazards Of Electricity
Advertisements

Introducing Electricity and Electrical Safety
Electrical safety Electrical Safety Testing Procedure Content
Electrical Safety.
Electrical Safety Electrical Safety In and Around the Home NUECES COUNTY Risk Management Department.
Electrical Safety Scenarios
Electrical Safety Basic Electrical Safety Rafael Coll, Environment Safety and Health Section Health& Safety Group Ext Pager: (630)
Electrical Safety 29 CFR I. Background for the Trainer:
CHEM 521 Safety Presentation. Hazard Symbols You Must Know.
Section 2 Safety, Tools and Equipment, Shop Practices Unit 4 General Safety Practices.
By: Aseem Aggarwal. Causes of Electrocution Fatalities Contact with Overhead Power lines Contact with Live Circuits Poorly Maintained Extension Cords.
Electrical Safety and Grounding Essentials Copyright © Texas Education Agency, All rights reserved.
Better Safe Than Sorry A WORLD THAT STARTS WITH ELECTRICAL HAZARDS AND SAFETY. ELECTRICITY IS A VERY SERIOUS BUSINESS AND THE EFFECTS ON THE HUMAN, ELECTRICAL.
Annual Refresher Electrical Safety. Electrical Safety Precautions Inspect equipment periodically. Make sure it is properly grounded. Replace any frayed.
Standard 29 CFR Part Welding, Cutting and Brazing Training.
ELECTRICAL SAFETY Safety Training for the Non-Qualified.
Technician License Course Chapter 9 Lesson Module 20: Electrical Safety.
Technician License Course Chapter 9 Lesson Module 20: Electrical Safety.
Electrical Safety in the Laboratory Joshua D. Horvath Andrew J. Gellman Carnegie Mellon University Department of Chemical Engineering February 18, 2003.
LABORATORY ELECTRICAL SAFETY Discussion topics: Electrical shock hazards Identifying hazards Research apparatus/ systems Proper emergency procedures Electricalfor.
Module 1A: Safety and Health Alexander MacFarlane.
Electrical Safety 29 CFR Concerned About Electricity? How many sets of Christmas lights do you plug into one extension cord? Do you still use.
Unit 4, Lesson 9 Keeping You and Your Computer Safe AOIT Computer Systems Copyright © 2008–2013 National Academy Foundation. All rights reserved.
Imagination at work Ground Fault Circuit Interrupters Jonathan Potter GE Energy Management Industrial Solutions.
Safety Training For The Non-Qualified
Basic Electrical Safety
ADVANCED ELECTRICAL SAFETY AWARENESS February 9, 2008 Guest Palace Hotel Doha, Qatar Engr. Amado B. Taduran Philippine Association of Safety Engineers.
© Business & Legal Reports, Inc Alabama Retail is committed to partnering with our members to create and keep safe workplaces. Be sure to check out.
Electrical Safety.
Electrical Safety INSTRUCTOR’S NOTES:
Electrical Safety INSTRUCTOR’S NOTES:
Electrical Safety.
Devices (TV, Refrigerator, etc) are rated for maximum power/voltage/etc. (They stop working if exceeded) Devices can be overpowered by accident by  overloading.
Copyright © 2008–2011 National Academy Foundation. All rights reserved. Unit 4, Lesson 9 Keeping You and Your Computer Safe AOIT Computer Systems.
20.3 Electric Circuits
Basic Electrical Safety
Copyright  Progressive Business Publications Electrical Safety.
BEAMLINE for SCHOOLS – East Area ELECTRICAL HAZARDS SAFETY 11 th September 2015 HSE Unit 1.
Accommodation & Hospitality Services STAFF BRIEFING – No 16 Electrical Safety.
Electrical Principles and Wiring Materials Unit #31.
Shop Safety Electrical Hazards….  Even small electric shocks are dangerous  Many hazards include electrocution, fire, or explosions  Even small electric.
Chapter 7 Safety. Introduction This chapter covers the following topics: Dangers of electricity Preventive measures Electrostatic discharge Safety practices.
Unit 4: General Safety Practices
Proper Use of Extension Cords
Tulane University - Office of Environmental Health & Safety (OEHS) Electrical Safety For Office, Facility, and Laboratory Employees Tulane University October.
ELECTRICAL SAFETY OUTLINE  The basic effect of electricity on human body  Ventricular Fibrillation  Electric shock  Electric Shock – Treatment  Important.
Electrical Safety and Electrical Safe Work Practices EHS Course #525 Reference EHS Electrical Safety Procedure
Relationship between power, current, voltage and resistance: P = power (watts) I = current (amperes) V = voltage (volts) R = resistance (ohms) Example:
Lab Safety MYCAERT INC.. What is Safety? Safety is preventing injury and loss. Injury and loss may be inflicted on people or their property.
Electrical Safety Chapter 2 Section 6 Pages
Current Electricity is the rate at which charges pass a given point. The higher the current is the greater the number of charges pass the point each second.
Electrical Safety, Subpart K
Services Electrical Safety & LOTO Awareness Training.
Timing (minutes) Learning ObjectiveMain tasks / ProcessResources / tools 5TitleStandard Operating Procedures for Power Press Machine Slide 1 5Index 
Chapter 3 PHYSICAL INJURY AND CONTROLS 3.2 Electrical Safety
Electrical Safety Basic Electrical Safety. Electrical Safety  Course not designed to teach you to work on electrical equipment. Basic Electrical Safety.
ELECTRICAL SAFETY in the Lab. 1.Electricity takes the path of least resistance. 2.Electricity wants to go to ground. 3.If an electrical appliance or tool.
Electrical Safety and Safe Work Practices
Laboratory Safety: Electricity
Electrical Safety.
Basic Electrical Safety
Hazards of Electricity Electrical Hazards Include Electrical Hazards Include Electrical Shock Electrical Shock Electrical Explosions Electrical Explosions.
Electrical Safety Review Compliance Assistance Region IV
Shop Safety Electrical Hazards….
Lab Safety.
Basic Electrical Safety
Click anywhere to get started…
Basic Electrical Safety
Presentation transcript:

Electrical hazards are present in all laboratories. Adherence to all electrical safety standards is essential in preventing electrical accidents

A COMPLETE CIRCUIT OR LOOP IS NECESSARY FOR CURRENT TO FLOW

E LECTRICITY IN THE BODY Muscles Muscles control all the body movements Including & importantly those that keep us alive - Breathing and Heart The brain controls voluntary muscles using Current pulses along nerves

E LECTRICITY IN THE BODY External current through the body causes Loss of muscle control Spasms & Involuntary movement Inability to let go Burns - external & internal

The severity and effects of an electrical shock depend on a number of factors, such as The pathway through the body The amount of current The length of time of the exposure Whether the skin is wet or dry.

P HYSIOLOGICAL E FFECTS OF E LECTRICITY CurrentReaction 1-5 Milliampere Slight shock felt; not painful but disturbing 6-30 MilliamperesPainful shock; "let-go" range Milliampere Extreme pain, respiratory arrest, severe muscular contraction 1,000-4,300 Milliamperes Ventricular fibrillation 10,000+ Milliamperes Cardiac arrest, severe burns, and probable death

E LECTRICAL H AZARDS Major hazards associated with electricity are electrical shock and fire. Electrical shock occurs when the body becomes part of the electric circuit, when: An individual comes in contact with both wires of an electrical circuit. One wire of an energized circuit and the ground. Or a metallic part that has become energized by contact with an electrical conductor.

In addition to the electrical shock hazards, sparks from electrical equipment can serve as an ignition source for flammable or explosive vapors. Loss of electrical power can result in extremely hazardous situations: Flammable or toxic vapors may be released as a chemical warms when a refrigerator or freezer fails. Fume hoods may cease to operate, allowing vapors to be released into the laboratory.

C OMMON E LECTRICAL P ROBLEMS Extension Cords and Power Strips Power Cords Solvents and Electricity Water and Electricity Laboratory Equipment Capacitors and Transformers

P OWER STRIPS ARE APPROVED FOR USE ONLY WITH COMPUTERS AND COMPUTERIZED EQUIPMENT. P OWER STRIPS SHOULD BE USED SPARINGLY. C ARE MUST BE TAKEN NOT TO OVERLOAD POWER STRIPS.

EXTENSION CORDS ARE APPROVED FOR TEMPORARY USE ONLY. IF EXTENDED USE IS REQUIRED, HARD WIRING SUCH AS A NEW OUTLET SHOULD BE INSTALLED. EXTENSION CORDS ARE EASILY FRAYED, A CONDITION WHICH MAY EXPOSE BARE WIRES.

Power cords are doubly insulated and should be replaced if the outer layer of insulation becomes frayed exposing wires.

P OWER C ORDS Avoid dangling cords and cords at floor.

O VERLOADS OCCUR WHEN MORE CURRENT FLOWS THROUGH A CORD THAN IT IS RATED TO HANDLE. P OWER STRIPS CAN BE OVERLOADED IF TOO MANY HIGH CURRENT DRAW DEVICES ARE PLUGGED IN AT ONE TIME

C OMMON LABORATORY EQUIPMENT SUCH AS CENTRIFUGES AND OVENS ARE HIGH CURRENT DRAW DEVICES. I F TWO OR MORE HIGH CURRENT DRAW DEVICES ARE PLUGGED INTO THE SAME OUTLET OR POWER STRIP AN OVERLOADED CIRCUIT MAY RESULT.

C ARE MUST BE TAKEN TO INSURE THAT POWER CORDS DO NOT COME IN CONTACT WITH HOT SURFACES SUCH AS THE TOP OF A HOT PLATE WHERE THEY MAY MELT EXPOSING BARE WIRES.

P OWER STRIPS MUST BE LOCATED OUTSIDE OF ANY FUME HOOD WHERE FLAMMABLE VAPORS ARE PRESENT.

W ATER AND E LECTRICITY Eyewashes should be located away from electrical devices and outlets. Outlets within six feet of a sink or other source of plumbing must be protected in order to minimize shock hazards. An unprotected outlet is illustrated in this picture

Safety showers must not be located directly over switches, outlets, equipment, or other sources of electrical energy such as those shown in the picture to the left.

P OWER SUPPLIES REPRESENT A POTENTIALLY LETHAL SOURCE OF ELECTRICAL ENERGY. E XPOSED CONNECTORS SUCH AS BANANA CLIPS ( ALLIGATOR CLIPS ) SHOULD NEVER BE ATTACHED TO A POWER SUPPLY OR ANY OTHER HIGH VOLTAGE, HIGH CURRENT PRODUCING DEVICE.

Electrophoresis equipment containing high voltage power supplies are found in many laboratories. Care must be taken to use only approved equipment. Leads should be checked periodically for frays.

Flammable storage refrigerators are specially designed for flammable liquid storage. The interior of these types of refrigerators do not contain any potential spark sources such as lights and switches.

B ASIC E LECTRICAL S AFETY G UIDELINES Learn the location of your electrical panels and shut-off switches so you can quickly disconnect power in the event of an emergency. Always leave at least a 3-foot clearance around electrical panels for ready access. Plan ahead for what steps will be taken in the event of a power loss. Conduct a periodic inspection of laboratory electrical equipment to be sure it is in good condition. Electrical outlets should have a grounding connection and accept three-prong plugs. Multiple plug outlet adapters are not allowed.

E LECTRICAL F IRES Unplug equipment first. Use dry chemical fire extinguisher. If fire is large, unplug equipment and call fire dept. Never use water!!.

Type A fire extinguishers use water to put out fires. They are not approved for use on electrical fires. Type A extinguishers are denoted by a pressure gauge at the top of the unit that indicates whether or not the extinguisher is fully charged