Advanced Control Systems

Slides:



Advertisements
Similar presentations
CONTROLS OF SUPER CRITICAL BOILERS
Advertisements

Chapter 2 Traditional Advanced Control Approaches – Feedforward, Cascade and Selected Control.
Operational Ideas for Supercritical Systems The Ultimate Criteria for Appreciation ….. P M V Subbarao Professor Mechanical Engineering Department I I.
MISS. RAHIMAH BINTI OTHMAN
Energy Efficient Steam Systems
Enhanced Single-Loop Control Strategies
CHAPTER I INTRODUCTION
Ratio Control Chapter 15.
CHE 185 – PROCESS CONTROL AND DYNAMICS
1 ChE / MET Apr 12 Process Linearity, Integral Windup, PID Controllers Linearity, Windup, & PID.
Dynamic Behavior of Closed-Loop Control Systems Chapter 9.
Control System Instrumentation
CHE 185 – PROCESS CONTROL AND DYNAMICS
Superheaters.
CHE 185 – PROCESS CONTROL AND DYNAMICS
Dynamic Behavior Chapter 5
THE INTRODUCTION OF AUTOMATIC PROCESS CONTROL
CHE 185 – PROCESS CONTROL AND DYNAMICS
Lecture 11. Real Heat Engines and refrigerators (Ch. 4) Stirling heat engine Internal combustion engine (Otto cycle) Diesel engine Steam engine (Rankine.
Practical Process Control Using Control Station
1 Fifth Lecture Dynamic Characteristics of Measurement System (Reference: Chapter 5, Mechanical Measurements, 5th Edition, Bechwith, Marangoni, and Lienhard,
Enhanced Single-Loop Control Strategies
Non Isothermal Chemical Reactor ChE 479 Alexander Couzis.
CONTROL SYSTEM INSTRUMENTATION
Strategies to Achieve A Fast Cycle with High & Safe Peak Pressure in SI Engines P M V Subbarao Professor Mechanical Engineering Department Fuel Economy.
Control System Instrumentation
Classification of Instruments :
Gas Turbine Power Plant
CHAPTER II PROCESS DYNAMICS AND MATHEMATICAL MODELING
Process Operability Class Materials Copyright © Thomas Marlin 2013
Process Operability Class Materials
Chapter 2. Control Objectives and Benefits
1 Dynamic Behavior Chapter 5 In analyzing process dynamic and process control systems, it is important to know how the process responds to changes in the.
MISS. RAHIMAH BINTI OTHMAN
SUBMITED BY BISWAJIT BEHERA
Energy and the Environment Spring 2014 Instructor: Xiaodong Chu : Office Tel.: Mobile:
Cascade and Ratio Control
26 Nov 12 Process Linearity, Integral Windup,
Richard Kelly, D.I.T.1 Facilities Management and the Environment BSc in Electrical Services and Energy Management.
Process Control: Designing Process and Control Systems for Dynamic Performance Chapter 7. The Feedback Loop Copyright © Thomas Marlin 2013 The copyright.
NOVO ETS IMPROVING YOUR ORGANIZATIONS’ ENVIRONMENTAL, HEALTH AND SAFETY PERFORMANCE ENERGY MANAGEMENT IN THE CONTEXT OF GREEN PRODUCTIVITY.
Outline Skogestad procedure for control structure design I Top Down
Control System Instrumentation
DYNAMIC BEHAVIOR OF PROCESSES :
PROCESS CONTROL SYSTEM (KNC3213) FEEDFORWARD AND RATIO CONTROL MOHAMED AFIZAL BIN MOHAMED AMIN FACULTY OF ENGINEERING, UNIMAS MOHAMED AFIZAL BIN MOHAMED.
Chapter 11 Heat Exchangers ( ) Heat Exchangers.
Topic 5 Enhanced Regulatory Control Strategies. In the last lecture  Feedforward Control –Measured Vs Unmeasured Loads –Purpose of feedforward control.
1 II. Bottom-up Determine secondary controlled variables and structure (configuration) of control system (pairing) A good control configuration is insensitive.
1 ChE / MET Apr 12 Cascade Control: Ch 09 Ratio Control: Ch 10 Advanced control schemes.
Valves In Industry (Part 1)
Chapter 3 : Simple Process Dynamics and Transfer Function
Dr. Owen Clarkin School of Mechanical & Manufacturing Engineering Summary of Energy Topics Chapter 1: Thermodynamics / Energy Introduction Chapter 2: Systems.
MISS. RAHIMAH BINTI OTHMAN
Cascade Control Systems (串级控制系统)
ERT 321 – Process Control & Dynamics Feedforward & Ratio Control Ms Anis Atikah Ahmad
Gas Turbine Power Plant
Lecture 11. Real Heat Engines and refrigerators (Ch. 4)
Control System Instrumentation
ERT 321 – Process Control & Dynamics Feedforward & Ratio Control
Workshop for Flipped Class
Introduction to process control
Control System Instrumentation
Process Control Engineering
Plant-wide Control : part1
Enhanced Single-Loop Control Strategies
Control System Instrumentation
Priyatmadi Jurusan teknik Elektro FT UGM
Introduction to process control
Process Operability Class Materials Copyright © Thomas Marlin 2013
Egyptian Atomic Energy Authority (EAEA), Egypt
Presentation transcript:

Advanced Control Systems Selective Control Systems These are control systems that involve one manipulated variable and several controlled outputs. Since with one manipulated variable we can control only one output, the selective control systems transfer control action from one controlled output to another according to need.

Override Control During the normal operation of a plant or during its startup or shutdown it is possible that dangerous situations may arise which may lead to destruction of equipment and operating personnel. In such cases it is necessary to change from the normal control action and attempt to prevent a process variable from exceeding an allowable upper or lower limit. This can be achieved through the use of special types of switches: HSS (high selector switch):- whenever a variable should not exceed an upper limit. LSS (low selector switch); to prevent a process variable from exceeding a lower limit.

Override Control Override control to protect a boiler system PT Steam LT LC LSS PC Discharge Line Loop 1 Loop 2 Boiler Water Steam pressure in the boiler is controlled through the use of a pressure control loop on the discharge line (Loop 1). Water level in the boiler should not fall below a lower limit necessary to keep the heating coil immersed in water thus preventing its burning out. Therefore an override control system using an LSS is used. If liquid level falls below the allowable limit, the LSS switches the control action from pressure control to level control (Loop 2) whenever discharge pressure reaches the upper limit.

Override control to protect a compressor An override control with HSS is used to prevent discharge pressure from exceeding an upper limit. It transfers control action from the flow control to the pressure control loop (Loop 2). SC Motor FT FC PT PC HSS Loop 1 Loop 2 Gas in Gas out Compressor Override control to protect a compressor

ii- Auctioneering Control Temperature Hot Spot L Auctioneering control system for a tubular catalytic reactor TC TT Auctioneering system Reactants Products Coolant

Controller’s output signal Split Range Control The split range configuration has one measurement only (controlled output) and more than one manipulated variable. Reactor PT PC V2 V1 Reactants Products Reaction system with split-range control Valve stem position Controller’s output signal Open Closed 3 6 9 15 V2 V1 psi Controller’s output signal Valve, V1 Stem position Valve, V2 3 psig Open Closed 9 psig 15 psig

Adaptive Control It is a control system which can adjust its parameters automatically to compensate for variations in the characteristics of the process it controls

Why do we need adaptive controller in Chemical Processes? Most chemical processes are nonlinear,  linearized models that are used to design linear controllers depend on the particular steady state around which the process is linearized. As desired steady state operation of a process changes the best values of the controller parameters change. Most of the chemical processes are non-stationary i.e. their characteristics change with time e.g. decay of catalyst activity in a reactor and the decrease of the overall heat transfer coefficient in a heat exchanger due to the fouling. This change leads to deterioration in the performance of the linear controller which was designed using some nominal values for the process parameters.

. Programmed or Scheduled Adaptive Control Controller Process Adjustment mechanism Set Point Controlled Output Auxiliary measurements New values of controller parameters Outer Loop Inner Loop Suppose the process is well known i.e. an adequate mathematical model for it is available. If there is an auxiliary process variable which correlates well with the changes in process dynamics, by measuring the value of the auxiliary variable we can program the adaptation of a programmed adaptive control system. The figure shows the block diagram of a programmed adaptive control system.

Example : Programmed Adaptive Control of a Combustion System Consider a burner where the fuel/air ratio is kept at its optimal value to achieve highest combustion efficiency. This is maintained through a ratio control mechanism shown in the figure below. Fuel Air Desired ratio FT FC TT Ratio Adjustment Fuel Air Desired ratio FT FC Optimal value of F/A depends on the process conditions (e.g. air temperature). If we know how (F/A)op changes with Tair for max. efficiency  we can use programmed adaptive control system as shown in figure below.