Lecture 6a. Introduction I Chromatography was discovered by Russian botanist Mikhail Semyonovich Tsvett, who separated plant pigments using calcium carbonate.

Slides:



Advertisements
Similar presentations
In this presentation you will:
Advertisements

Lecture 7a Chromatography I.
Paper Chromatography 1Dr. Nikhat Siddiqi. Paper chromatography and TLC are examples of adsorption chromatography. 2Dr. Nikhat Siddiqi.
Lecture II. 5- collection of fraction and visualization Fraction could be collected based on 1- fixed volume 2- specified time.
Chapter 8 Thin-Layer Chromatography
Analysis of Analgesic Tablets by Thin Layer Chromatography (TLC) Organic Chemistry Lab I Fall 2008 Dr. Milkevitch Oct 12 & 14, 2009.
Lab Activity 7 IUG, Fall 2012 Dr. Tarek Zaida IUG, Fall 2012 Dr. Tarek Zaida 1.
Paper and Thin layer Chromatography
CHM 312 Fall 2008 CHROMATOGRAPHY. THIN LAYER CHROMATOGRAPHY (TLC)
Thin Layer Chromatography of Lipids
Sabrina Schmidtke Partnership for Environmental Education and Rural Health Protein Chemistry.
Experiment 15 A: Isolation of Pure Aspirin From Aspirin Tablets B: TLC of a Dye Mixture.
What is Chromatography?
PLANNAR CHROMATOGRAPHY
Chromatography and Instrumentation. Invented by a Russian Botanist Mikhail Tswett in 1903 He used chromatography to separate the colour pigments in plants.
Dr. Samah Kotb Nasr Eldeen.  Amino acids: are the building blocks of peptides and proteins.  They possess two functional groups, the carboxylic acid.
What is Chromatography? Chromatography is a technique for separating mixtures into their components in order to analyze, identify, purify, and/or quantify.
Chromatography Chromo: color Graph: to write
Paper and Thin Layer Chromatography (TLC) Experiment 4 BCH 333[practical]
Chromatography Lab # 5.
Chromatographic Separation
Chromatography Dr.Tawfeq A. Al-Howiriny Associate Professor
THIN-LAYER CHROMATOGRAPHY Judith is preparing her TLC chamber, which is shown at left in the developing step #4. Scroll down for her to guide you through.
Column and Thin Layer Chromatography
What is Chromatography? Chromatography is a technique for separating mixtures into their components in order to analyze, identify, purify, and/or quantify.
Experiment.13 Amino acid analysis by adsorption thin layer chromatography (adsorption TLC)
Chromatography. TLC Thin layer chromatography Stationary phase Mobile phase.
Alexandria University Faculty Of Science Practical Training Course In Applications Of Plant Physiology Prepared By Dr. Mohamed Mohamed Ibrahim Lecturer.
Lecture 12 Chromatography Introduction Ch 7: Thin-Layer Chromatography Lecture Problem 4 Due This Week In Lab: Ch 6: Procedures 2 & 3 Due: Ch 5 Final Report.
TLC and HPLC of Nitroanilines
Paper and Thin Layer Chromatography (TLC) Experiment 6 BCH 333 [practical]
Thin-Layer Chromatography (TLC) Uses: To separate the components of a mixture To determine the purity of a compound To see if two compounds are identical.
Chromatography Chapter Dr Gihan Gawish. 1. Paper Chromatography Dr Gihan Gawish  Paper chromatography is a technique that involves placing a small.
Chromatography is a technique for separating mixtures into their components in order to analyze, identify, purify, and/or quantify the mixture or components.
HPLC.
Lab Activity 7 IUG, Fall 2012 Dr. Tarek Zaida IUG, Fall 2012 Dr. Tarek Zaida 1.
Cellular Biochemistry and Metabolism (CLS 333 ) Dr. Samah Kotb Nasr Eldeen Identification of free amino acids by Thin layer chromotography (TLC) using.
1/17/ Thin-Layer Chromatography References: Pavia:Experiment 5A; pp. 36 – 39 Technique 2.0; pp. 801 – 812 Note:The above reference material is not.
PAPER CHROMATOGRAPHY.
By Susan McCullough With Thanks to Lori Olson at SRI International.
Chromatography.
Experiment 5: Chromatography
Thin Layer Chromatography(TLC)
PLANAR CHROMATOGRAPHY Ferosekhan. S FNB-41 Chromatography Chromatography is a technique for separating mixtures into their components in order to analyze,
THIN LAYER CHROMATOGRAPHY
PAG6 TLC. Need to book Repro – Example results or Page 19 of delivery guide – Example method – FLIPPED learning sheet for start of nucleotides Applied.
THIN LAYER CHROMATOGRAPHY
THIN LAYER CHROMATOGRAPHY.
Thin Layer Chromatography. Thin layer chromatography The common adsorbent materials are silica, alumina, kieselguhr, celite, cellulose powder, ion exchange.
Lecture 11 Chromatography 2 Thin Layer Chromatography (TLC)
PAPER CHROMATOGRAPHY.
What is Chromatography?
THIN LAYER CHROMATOGRAPHY
PLANNAR CHROMATOGRAPHY
Lab Activity 7 Separation of blood serum lipids by thin-layer chromatography IUG, Dr. Tarek Zaida.
Lab Activity 5 Separation of blood serum lipids by thin-layer chromatography IUG, Fall 2017 Dr. Tarek Zaida.
Lab Activity 4 IUG, Fall 2017 Dr. Tarek Zaida.
What is Chromatography?
Dnyanasadhana College, Thane. Department of Chemistry T. Y. B. Sc
Chromatography.
Lecture 7a Chromatography I.
SEPARATION TECHNIQUES
ADSORPTION CHROMATOGRAPHY
Thin layer chromatography (TlC) Saman Kotigala BSc MSc.
Hands-on Chromatography
What is Chromatography?
Lab Activity 7 Separation of blood serum lipids by thin-layer chromatography IUG, Fall 2017 Dr. Tarek Zaida.
1/18 Objective: Explain the purpose and process of chromatography.
Lab Activity 4 IUG, Fall 2017 Dr. Tarek Zaida.
What is Chromatography?
Presentation transcript:

Lecture 6a

Introduction I Chromatography was discovered by Russian botanist Mikhail Semyonovich Tsvett, who separated plant pigments using calcium carbonate columns (1901) Martin and Synge (Noble Prize in Chemistry, 1952) established many of the basic techniques in partition chromatography i.e., paper chromatography, gas chromatography, HPLC, etc.

Applications TLC is usually performed on a glass, plastic or aluminum foil that is covered with an adsorbent (=stationary phase) Uses Monitor the progress of reactions Identify compounds in a mixture Determine the purity of a compound Optimizing a solvent mixture Applications Separation of dyes in pen ink (i.e., black ink) Separation and determination of pigments in plants (i.e., spinach) Monitor the progress of fermentation in wine making (T=tartaric acid, M=malic acid, L=lactic acid)

Stationary Phase Commonly used are silica, alumina, cellulose (i.e., paper chromatography), etc. These stationary phases are considered polar due the presence of hydroxyl groups on the surface and their ability to form hydrogen bonds with polar and protic solvents Silica-coated TLC plates are primarily used in organic labs because most of the compounds analyzed in the lab are (weakly) polar due to the presence of carbonyl groups, hydroxyl functions, etc. The type of stationary phase used in a given separation problem depends on the polarity of compounds and the separation mechanism

Mobile Phase The eluting power of the mobile phase depends on the polarity of the solvent vs. the polarity of the stationary phase Polar solvents i.e., alcohols have a high eluting power on polar stationary phases because they interact strongly with the polar stationary phase via their hydrogen bonding donor and a hydrogen bond acceptor ability Medium-polar solvents like ketones, esters and ethers possess a medium eluting power because they only act as hydrogen bond acceptors Non-polar solvents i.e., toluene, hexane, etc. have a low eluting power on polar stationary phases because their interaction with polar stationary phase is weak The general affinity of functional groups towards silica is: ionic > acids/bases > amides > alcohols > ketones > aldehydes > esters > ethers > halides > unsaturated hydrocarbons > saturated hydrocarbons

Experimental I TLC plate The plate is coated with a very thin layer (~0.25 mm) of a mixture of a stationary phase and a binder i.e., gypsum The stationary phase often also contains a fluorescent indicator (zinc silicate, zinc cadmium sulfide), which appears bright green when exposed to short wavelengths ( =254 nm) Preparation of the TLC plate The white surface should not be touched Draw a very thin start line with pencil or mark the plate on the lower end on each side (~0.5 cm from the bottom) Do not use a pen for this step

Experimental II Spotting A capillary spotter (drawn from a Pasteur pipette) or a commercial spotter should be used for spotting (top: melting point capillary, bottom: commercial spotter) Melting point capillaries, syringe needles, etc. (as is) are not suitable for the spotting process because they produce a huge spot that overloads the plate (=tailing, see also last slide)! The spots have to be equally spread at the starting line and not be located too close to the outer edges The spots have to be small in diameter (~1-2 mm) A diluted solution of the compound in a low-boiling, low polarity solvent i.e., diethyl ether, hexane, ethyl acetate, etc. has to be used (5 mg/mL) If the compound cannot be detected with the naked eye, the TLC plate has to be dried and then be inspected under the UV-lamp prior to development i.e., benzil, dibenzyl ketone are colorless in low concentrations

Experimental III Developing the plate A jar or a small beaker covered with a watch glass is used as development chamber, lining the walls with wet filter paper is usually not necessary if the jar is kept close The solvent level in the jar has to be below the starting line The TLC plate is placed straight in the chamber, which is left undisturbed The compounds move up the plate at different rates (if the proper mobile phase is used) Note that the rate of movement is not constant (Why?) The solvent front is allowed to move up the plate until ~1 cm from the top The plate is then removed and the solvent front immediately marked t=0 mint=1 mint=5 min Brown: Mixture Green: compound A Red: compound B

Experimental IV Visualization (for more reagents see SKR 326) First, the plate has to be dried thoroughly UV light: It is only useful if the compounds are UV active and the stationary phase contains a fluorescent indicator Iodine: It is used for unsaturated and aromatic compounds (brown stain, not permanent) Permangante: It is used for compounds that can be oxidized easily (mostly yellow on purple) Vanillin: It works well for hydroxyl and carbonyl compounds (appear in different colors depending on the compound) Ceric staining (CAM): It is good general stain but particularly sensitive for hydroxyl, carbonyl, epoxides (dark blue upon heating) Ninhydrin: It is used for amino acids, amines (often pink or purple) Bromocresol green: It is mainly used to detect carboxylic acids After marking the spots with pencil, the diagram is transferred to the notebook (taking a picture with the cell phone could not hurt either). Do not take the TLC plate home because the silica will rub off. Silica powder can cause a lung disease called silicosis.

Data Analysis Determination of R f -value gr Measure the distance of the center of the spot from the starting line (g, r) Measure the distance of the solvent front from the starting line (s) The R f -value is defined as the ratio of the travel distances The R f -value is a ratio and thus is a unitless number The R f -value has to be between 0 and 1 g r s

Solvent Effect Changes in the mobile phase have an impact on the movement of all compounds (with varying degree though due to changes in various parameters) The more eluting power the mobile phase (given as e 0 -values on silica above) has, the more the compounds move because the mobile phase interacts stronger with the stationary phase. This makes it more difficult for the compounds to interact with the stationary phase leading to higher R f -values and (often) poorer separation. Hexane e 0 =0.0 Chloroform e 0 =0.26 Diethyl ether e 0 =0.38

Common Problems Problem 1: All spots are grouped together on the lower (upper) end of the plate Solution 1: The eluting power of the solvent was too low (high) for this separation problem. A more polar (less polar) solvent should be added to the mobile phase (see previous slide). Problem 2: The spot is spread over a large part of the lane or does not look round. Solution 2: The student spotted too much of the sample on the plate that leads to tailing. Less sample should be spotted using the proper spotter. Problem 3: The spot has a crescent shape after the development. Solution 3: The solvent used to dissolve the sample was too polar and was not allowed to evaporate completely. Problem 4: The spots seem to run into each other on the top. Solution 4: Either the spots were to close at the start line or the TLC plate was not placed straight in the jar.