FP5000 Refer to www.eatonelectrical.com for the latest information on this constantly evolving productwww.eatonelectrical.com.

Slides:



Advertisements
Similar presentations
DS|POWER DS300 series New generation DSP controlled Uninterruptible power supplies.
Advertisements

CL100D series DSP controlled Uninterruptible power supplies.
سیستم آلارم دیجیتالی مجهز به ثبات خطا
Installation base of over 25,000 valued installations, Country wide Installation base of over 25,000 valued installations, Country wide Recognised as.
1. Four LLs were published in February Transmission Relaying – Undesired Blocking 2.Lack of Separation for Critical Control Power Supply Leads.
Model H Free Standing Static Transfer Switch. Why choose a model H static transfer switch? Increases power availability. True solid state. Rugged, reliable.
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
ModCon® 75 Controller.
1 GE Digital Energy Multilin Industrial Solutions for Energy Management and Energy Efficiency By John S. Levine, P.E. Levine Lectronics and Lectric, Inc.
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Multi Functional Digital Fault Recorder
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin
Tool removed during cycle Fault #2 Conditions for setting Tool cocked prox switch goes open during cycle AND force on load cell drops below limit in fault.
SYMAP-BC SYMAP-BC.
12-Port IP Power Manager IPM  Product Overview  Product Features  Applications  Comparison Presentation Outline 2 / 15.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
M Family Industrial Systems 1 M Family relays provide economical & reliable digital protection, metering, control and monitoring in an integrated package.
1 Lab Equipment. 2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope.
DATALOGGER Welcome to the Presentation on DATALOGGER.
Slide 1 / 35 P&T - GPS - Training PhB - 01_TECH_TeSys_U_controller_ en 06/2004 Presentation of the range Composition of the controller  Control base 
G GE Power Management MMII Intelligent MCC Controller.
DCRK DIGITAL POWER FACTOR CONTROLLERS
Make the most of your energy Make the most of your energy SM Add application photo in this area PowerLogic ® Branch Circuit Power Meter for data center.
MIG II DIGITAL FEEDER PROTECTION
Chapter 7 SYSTEM PROTECTION
MP-3000 Motor Protection.
The Peak in Performance
G GE Power Management 369 Motor Management Relay.
1 Industrial Systems A dvanced L ine P rotection S ystem.
Workflow Based Tools Simplifying All Job Functions.
ZTE Series Automatic Transfer Switches (ATS)
G650 Generator Protection & Control System
Scheduled Versus Event Driven Testing of Distribution Protection IEDs Dr. Alexander Apostolov, Benton Vandiver, Will Knapek, OMICRON electronics.
Looking for a more powerful circuit monitor?
FG Wilson Access 4000 Control Panel
SFT 2841 IN CONNECTED MODE Prepare setting files.
Distribution Automation Overview, Activities, and Roadmap David G
New IQ300 IQ Data & IQ Generator Replacement. Current Product  IQ Data Measures  Phase Currents  Voltage L-L, L-N  IQ Generator adds  Frequency measurement.
1 Monitor System Reliability alarm on demand, sag/surge, and etc. Perform Advanced Power Quality Analysis provide real-time trending. Centralized.
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
Electrical Distribution Training
Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.
TYPICAL SCADA SYSTEM FIELD UNIT SCADA H/W & S/W C TX O RX M E M Q N P
Universal Relay Family B30 Presentation Q&As. Power Management The Universal Relay Contents... Application Algorithm Biased Characteristic Dynamic Bus.
IQ Analyzer 6400/6600 Series Cutler-Hammer Power Management Products High End Metering Capabilities.
Electrical Distribution Training Logic Equation Editor.
Queensland University of Technology CRICOS No J Protection of distributed generation connected networks with coordination of overcurrent relays.
SmartMQn Motor Horner APG, LLC September 9, 2008.
Motor. What Does it Do? Monitors three phase motors for a number of current, temperature, estimated power and timing parameters. Provides motor protection.
Announcements Read Chapters 10 and 11
Main contacts closed – RED Colour with ON
SmartMQn Motor Protective Functions Ken Jannotta Jr. Horner APG, LLC.
Flip Flops Engr. Micaela Renee Bernardo. A latch is a temporary storage device that has two stable states (bistable). It is a basic form of memory. Latches.
Sub-Synchronous Frequency Detection Using SEL OGIC ® Control Equations SSF Relay ERCOT Workshop NPRR562 Subsynchronous Resonance Larry Gross.
Tool Removed During Cycle Fault #2 Conditions for Setting Tool cocked prox switch goes open during cycle AND force on load cell drops below 5 lbs. Active.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
G GE Power Management 269Plus Motor Management Relay.
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 1 HighPROTEC-2 MRI4-2 Feeder Relay Sales presentation 2015/08/10.
MegaTronandMegaTronSS Water Treatment’s Most User Friendly Web Capable Controllers.
HighPROTEC-2 MRA4-2 Directional Feeder Relay Sales presentation
PMC-680i Front Panel Interface Display Firmware Version V
TPS - Thyristor Power Supply for Resistive/Inductive Loads
Digital Fundamentals Floyd Chapter 7 Tenth Edition
FEEDER PROTECTION UNIT
Chapter 7 System Protection
Protection Philosophy
METER SPECIFICATIONS.
PowerLogic™ offer for the basic metering market
PowerLogic PM5350 High-performance multifunction power meter
Presentation transcript:

FP5000 Refer to for the latest information on this constantly evolving productwww.eatonelectrical.com

FP5000 Product Overview Microprocessor design combines protection, metering and control into a single compact package Flexible configuration and programmable logic control for custom applications Easy navigation keys and menu structure make it simple and safe to use Meets ANSI, UL and CUL standards

FP5000 Product Overview User Interface –Latching cover and Password protection for security –4 x 20 character vacuum fluorescent display for improved readability –18 status LED’s for trip, alarm, breaker status and display mode indication Battery backed up trip LED for target indication even if station is dead –Direct access to monitoring, view settings, logs and status/control screens –Breaker open/close buttons can provide direct breaker control when enabled

FP5000 Product Overview Hardware –Advanced 32 bit Microprocessor design –Compact drawout case design for easy installation and removal –Four currents inputs (1A or 5A) Measured three phase and ground currents Calculated residual ground current –Four voltage inputs Three phase plus fourth auxiliary voltage measurement

FP5000 Product Overview Hardware –8 optically isolated contact inputs –5 trip rated “a” contact outputs 2 outputs with circuit continuity monitoring –2 form c alarm contacts One is for relay healthy alarm –C-H Zone Interlocking Circuitry –Inputs and outputs are user configurable

FP5000 Protection Features One-line Drawing

Instantaneous Overcurrent 50 (P,X,R)

FP5000 Protection Features Three phase and ground overcurrent (50P-1, 50P-2, 50P-3, 51P and 50R-1, 50R-2,50R-3,51R, 50X-1,50X-2,50X-3,51X) –Measured (X) and calculated (R) ground currents Negative sequence overcurrent (46-1, 46-2) Three phase over and under voltage protection (27M-1, 59M-1, 27M-2, 59M-2) Single phase over and under voltage protection (27A-1, 27A-2, 59A-1, 59A-2) Over and under frequency protection (81U-1, 81U-2, 81O-1, 81O-2)

FP5000 Protection Features Negative sequence over voltage protection (47-1,47-2) Breaker failure (50BF) –Internal Breaker Failure Initiation –External Breaker failure Initiation Apparent and Displacement Power factor (55A,55D) Four setting groups available

Time Overcurrent 51 (P,X,R)

Current Unbalance 46

Voltage Unbalance 47

Main Over Voltage 59M

Main Under Voltage 27M

Auxiliary Over Voltage 59X

Auxiliary Under Voltage 27X

Over Frequency 81O

Under Frequency 81U

Breaker Failure Logic

FP5000 Protection Features Zone Interlocking –Faster fault clearing times with better zone coordination –Stuck breaker (breaker failure) accelerated remote fault clearing –Phase and ground selectable –Extended range up to 1000’ –Works with DT3000

Zone Interlocking Location 2 CB2 sees fault & sends interlocking signal to upstream devices at CB1 Upstream devices continues to operate on normal set time for remote backup protection CB2 fast trips to interrupt fault If CB2 fails to interrupt fault in 10 cycles remote clearing of CB1 occurs Location 1 CB2 does not see the fault - no signal is sent to CB1 CB1 sees fault but does not receive interlocking signal - Fast Trips Zone 1 Zone 2 CB1 Fault 2 FP5000 Protection Features CB2 Fault 1

FP-5000 Metering Features RMS Load Values –Currents - Ia, Ib, Ic, IX, IR, I Average –Voltages - LL, LN, VX, LL Average, LN Average –System Power - Watts, vars, VA –Power Factor, Frequency –% THD Voltage and Current –Magnitude THD Voltage and Currents Current accuracy ±0.5% or ±0.025 A Voltage accuracy ±0.5% or ±0.02 V Power accuracy ±1.5% worse case

FP5000 Metering Features Fundamental phasor measurements –Magnitude and phase angle of voltages and currents –Magnitude and phase angle of positive, negative and zero sequence voltages and currents –Percent voltage unbalance and phase rotation (%V2/V1) –Percent current unbalance and phase rotation (%I2/I1)

FP-5000 Metering Features Energy Measurements –System Watt Hours - Forward, Reverse, Net –System var Hours - Forward, Reverse, Net –System VA Hours –Start Date & Time for Energy Accumulation Minimum & maximum values –Phase and Ground Currents –Voltages - LL and LN –System Power –Frequency –Power Factor –time and date stamp

FP-5000 Monitoring Features Relay self-diagnostics and Relay Healthy Alarm Output (failsafe operation) –Memory and setting checks –Calibration and A/D monitoring –Power supply monitoring –Watchdog timer Trip circuit monitoring and alarming Close circuit monitoring and alarming

FP-5000 Monitoring Features Circuit breaker monitoring and Alarming –Breaker open/close state and indication –Operation counter and alarm –Breaker wear alarm (accumulated interrupted current per phase) –52 auxiliary contact monitoring with 52a and 52b contact inputs connected –Sluggish breaker operation monitoring –Loss of Vacuum monitoring –Stuck breaker (breaker failure)

Breaker Duty

Breaker Monitoring Logic

FP5000 Logic & Control Features

FP-5000 Logic & Control Features Breaker open and close logic with front panel open/close control Power factor monitoring and cap bank switching control Output contact logic gate control Overcurrent blocking gates Multiple setting group selection and control Main-tie-main transfer schemes

FP-5000 Logic & Control Features Programmable logic control function –Six programmable logic gates AND OR, NAND, NOR 4 programmable inputs –Six programmable timers Pick up time delay Drop out time delay –Two Latching logic gates –Use internal or external signals

FP-5000 Data Logging Features Event Log Trip Log History Log Data Logger (communication access only) Waveform Capture (communication access only)

FP-5000 Data Logging Features Event log records 100 events with date and time stamp ( 1 ms resolution) –Event Types General –Control power on/off –Breaker open/close –Reset demand, min/max, energy –Change settings Trip, alarm, pickup, dropout Input / output state change Self-test warning

FP-5000 Data Logging Features Trip log records last 16 trips –Date & time stamp (1 ms resolution) –Fault type, status –Trip counter, event number, osc buffer –Time to trip (51 elements) –Phase currents & voltages (rms. and phasor) –Frequency –I/O and logic states

FP-5000 Data Logging Features History log records accumulated values –Number of operating hours –Number of trips –Number of breaker operations –Accumulated interrupted amps per phase –Times powered up –Number of setting changes –Date and time stamp of last reset

FP-5000 Data Logging Features Data logger –1024 records in 128 blocks –Each block: timestamp & 8 records –Log 8 quantities in each record Default configuration logs currents & voltages Select from V, I, Power, PF, Freq, %THD, Demand, Contact inputs/outputs –Select logging interval from 1 s to 1 hour –Select continuous or single pass logging –Trigger: auto, Cin, Logic, PB, Comm.

FP-5000 Data Logging Features Waveform Capture –256 cycles of data storage –Select Trigger: Pickup, Trip, Cin, dV/dI, Logic, PB, Comm. –Number of pre-trigger cycles is configurable –Stored Parameters –32 samples per cycle: 4 Currents, 4 Voltages –Once a cycle: rms and phasor Voltages & Currents Frequency, Fault Type Input & Output States Pickup, Trip, Alarm, & Logic States

Power Port Main Screen Device Status Communication Settings

FP-5000 Display Setpoints System Configuration Settings

FP-5000 Display Setpoints Trip1 Output Relay Settings

FP-5000 Change Setpoints System Configuratio n Settings

FP-5000 Change Setpoints Protection Setting Group 1 Overview

FP-5000 Change Setpoints Phase Overcurren t Settings –51P ITOC –50P-1 IOC –50P-2 IOC

FP-5000 Change Setpoints Current & Voltage Unbalance Under & Over Voltage Protection

FP-5000 Change Setpoints Breaker Failure Power Factor Over & Under Frequency Protection

FP-5000 Change Setpoints Datalogger Configuration

FP-5000 Change Setpoints Waveform Capture Configuration

FP-5000 Change Setpoints Contact Input Configuration

FP-5000 Change Setpoints Trip 1 Output Relay Settings

FP-5000 Change Setpoints Indicator Settings

FP-5000 Monitoring Metering Overview

FP-5000 Monitoring Voltage Phasors

FP-5000 Monitoring Overcurrent Protection Function Status

FP-5000 Monitoring Input Status

FP-5000 Monitoring Output Status

FP-5000 Control Relay Control Reset Functions Active Setting Group Control