SoLID EC Design for IHEP 2012/10. Basic Features of Preliminary Design Based on COMPASS Shashlyk module design. 0.5mm lead/0.12mm air gap/1.5mm scintillator/0.12mm.

Slides:



Advertisements
Similar presentations
Zhiwen Zhao 2011/12/09. Outline  Configuration  Requirements  Calorimeter design  Beam Test plan  Help we need 1.
Advertisements

CBM Calorimeter System CBM collaboration meeting, October 2008 I.Korolko(ITEP, Moscow)
Quartz Plate Calorimeter Prototype Ugur Akgun The University of Iowa APS April 2006 Meeting Dallas, Texas.
DREAM Collaboration: Recent Results on Dual Readout Calorimetry. F.Lacava for the DREAM Collaboration Cagliari – Cosenza – Iowa State – Pavia – Pisa –
Jin Huang Los Alamos National Lab.  Cited from March collaboration Meeting EC group Internal Communication Jin Huang 2 Preshower ID power drop significantly.
R&D of Strip/Block Scintillators E.P.Jacosalem, S.Iba, N.Nakajima, H.Ono, A.L.Sanchez, A.M.Bacala & H.Miyata GLD Calorimeter Group 8 th ACFA Workshop on.
Jin Huang MIT SoLID Collaboration Meeting June 03, 2011, Jefferson Lab.
W. Clarida, HCAL Meeting, Fermilab Oct. 06 Quartz Plate Calorimeter Prototype Geant4 Simulation Progress W. Clarida The University of Iowa.
1 G4MICE studies of PID transverse acceptance MICE video conference Rikard Sandström.
GlueX Simulations Status Report on CD3 geometry Richard Jones GlueX Collaboration Meeting, Newport News, January 10-12, 2008.
1 EMCal design MICE collaboration meeting Fermilab Rikard Sandström.
Ultra-sensitive HALO monitor N. Vinogradov, A. Dychkant, P. Piot.
1 Tianchi Zhao University of Washington Concept of an Active Absorber Calorimeter A Summary of LCRD 2006 Proposal A Calorimeter Based on Scintillator and.
Study of response uniformity of LHCb ECAL Mikhail Prokudin, ITEP.
SoLID EC Update Zhiwen Zhao 2012/05/22. Beam test update Coverage for PVDIS Road map.
Shashlik type calorimeter for SHIP experiment
Beam test results of Tile/fiber EM calorimeter and Simulator construction status 2005/03/05 Detector Niigata University ONO Hiroaki contents.
Calorimeter Group. SoLID Collaboration Meeting 2.
R&D on W-SciFi Calorimeters for EIC at Brookhaven E.Kistenev, S.Stoll, A.Sukhanov, C.Woody PHENIX Group E.Aschenauer and S.Fazio Spin and EIC Group Physics.
SoLID baffle update Zhiwen Zhao 2013/04/02. Current Baffle The total distance from plane 1 to 6 is 150cm which is a few cm overlapping with endcap nose.
Shower Containment and the Size of a Test Calorimeter Adam Para, September 6, 2006.
Study of Sampling Fractions Shin-Shan Yu, A P, Hans Wenzel, October 18, 2006.
CALORIMETER system for the CBM detector Ivan Korolko (ITEP Moscow) CBM Collaboration meeting, October 2004.
Fiber update Zhiwen Zhao/Mehdi Meziane 2012/02/12.
The Tungsten-Scintillating Fiber Accordion Electromagnetic Calorimeter for the sPHENIX Detector Craig Woody, for the PHENIX Collaboration Physics Department,
Jin Huang Los Alamos National Lab.  Calorimeter defines the inner-R edge of large- angle acceptance  The proposal assumed a 2.5 degree polar angle gap.
Electromagnetic Calorimeter for the CLAS12 Forward Detector S. Stepanyan (JLAB) Collaborating institutions: Yerevan Physics Institute (Armenia) James Madison.
15-16 Oct 2005 Alice-USA meetingAleksei Pavlinov GEANT EMCAL geometry for ALICE current status Aleksei Pavlinov WSU.
Cherenkov Counters for SoLID Z.-E. Meziani on behalf of Simona Malace & Haiyan Gao (Duke University) Eric Fuchey (Temple University) SoLID Dry Run Review,
Scintillating Tiles for the Muon Inner regions LHCb Muon Upgrade meeting, CERN May Wander Baldini for the Ferrara LHCb group.
Hadron Calorimeter HCAL-J GEp Electron Calorimeter BigCal Hadron Calorimeter 1 G. Franklin, Carnegie Mellon University 10/13/2011.
Shashlyk FE-DAQ requirements Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA FE-DAQ workshop, Bodenmais April 2009.
The NA62 rare kaon decay experiment Photon Veto System Vito Palladino for NA62 Coll.
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
ECAL PID1 Particle identification in ECAL Yuri Kharlov, Alexander Artamonov IHEP, Protvino CBM collaboration meeting
Mechanics and granularity considerations of a Tile hadronic calorimeter for FCC hh barrel Nikolay Topilin/Dubna+ Sergey Kolesnikov/Dubna Ana Henriques/CERN.
DESY Beam Test of a EM Calorimeter Prototype with Extruded Scintillator Strips DongHee Kim Kyungpook National University Daegu, South Korea.
Magnetized hadronic calorimeter and muon veto for the K +   +  experiment L. DiLella, May 25, 2004 Purpose:  Provide pion – muon separation (muon veto)
MAMUD Magnetized hadronic calorimeter and muon veto for the K +   +  experiment L. DiLella, March 29, 2005 Purpose:  Provide pion – muon separation.
V. Korbel, DESY1 Progress Report on the TESLA Tile HCAL Option To be filled soon.
Study of SoLID Baffle, Background and Trigger Zhiwen Zhao UVa, ODU&JLab 2014/07/09 1.
SoLID DAQ A.Camsonne SoLID collaboration meeting November 8 th 2013.
DESY Beam Test of a EM Calorimeter Prototype with Extruded Strip Scintillator DongHee Kim Kyungpook National University Daegu, South Korea.
SPHENIX EMCAL R&D Craig Woody BNL sPHENIX Design Study Meeting September 7, 2011.
Geant4 Tutorial, Oct28 th 2003V. Daniel Elvira Geant4 Simulation of the CMS 2002 Hcal Test Beam V. Daniel Elvira Geant4 Tutorial.
SoLID Background Update Zhiwen Zhao UVa 2013/11/08 1.
Calorimeters Design Issues and Simulation Needs C.Woody Physics Department Brookhaven National Lab EIC Simulation Workshop Oct 9, 2012.
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
SoLID Simulation Update Zhiwen Zhao University of Virginia SoLID Collaboration Meeting 2011/10/14 Introduction GEMC Update Simulation Study Summary Introduction.
DEVELOPMENT OF THE POLYSTYRENE SCINTILLATOR TECHNOLOGY AND PARTICLE DETECTORS ON THEIR BASES VLADIMIR RYKALIN IHEP, PROTVINO INSTR-14, NOVOSIBIRSK, 24.
SHIP calorimeters at test beam I. KorolkoFebruary 2016.
Simulation and reconstruction of CLAS12 Electromagnetic Calorimeter in GSIM12 S. Stepanyan (JLAB), N. Dashyan (YerPhI) CLAS12 Detector workshop, February.
Update on EM Calorimeters Calorimeter Group. Overview SoLID Collaboration Meeting 2.
Update on EM Calorimeters Calorimeter Group. SoLID Collaboration Meeting 2 SoLID EM Calorimeter Overview PVDIS forward angle SIDIS forward angle SIDIS.
PPAC Jonathan Olson University of Iowa HCAL November 11-13, 2004.
1 SoLID Collaboration Meeting, July 9-10, 2014 Electromagnetic Calorimeters (EC) for SoLID The SoLID EC Working Group SoLID Collaboration Meeting July.
1 SoLID Collaboration Meeting, November 7-8, 2014 Electromagnetic Calorimeters (EC) for SoLID The SoLID EC Working Group SoLID Collaboration Meeting November7-8,
Update on EM Calorimeters
for SoLID Collaboration
FCAL R&D towards a prototype of very compact calorimeter
IHEP group Shashlyk activity towards TDR
KM2A Electron Detector Optimization
Jin Huang Los Alamos National Lab
Simulation Updates on PVDIS EC
Detector Configuration for Simulation (i)
Special Considerations for SIDIS
Study of a Scintillating Digital Hadron Calorimeter Prototype
Dual readout calorimeter for CepC
Update on EM Calorimeters
Zhiwen Zhao,UVa for EC group
Presentation transcript:

SoLID EC Design for IHEP 2012/10

Basic Features of Preliminary Design Based on COMPASS Shashlyk module design. 0.5mm lead/0.12mm air gap/1.5mm scintillator/0.12mm air gap – Assume Lead X 0 =0.56mm, scintillator X 0 =42.4cm, air gap needs to be replaced with actual wrapping or coating. – each layer 2.24mm(0.93X 0 ), total 216 layers, 48.3 cm in length (20 X 0 ) – Reach energy resolution of 5%/sqrt(E) with good linearity – Balance between resolution and longitudinal size 10x10cm of transverse size in square shape – reach 1cm position resolution – Balance between number of modules (cost), position resolution and background – Total about 2000 modules. Splitting : preshower and shower – Maximizing e-pi separation (20: :1 pion rejection depending on momentum) 100 WLS fibers/module – 1/cm 2 fiber density to sample the EM shower – Use KURARAY Y11 for higher radiation hardness and longer attenuation length or use Bicron fibers to save cost. Readout options in orders of preference: – Directly couple to PMT, if B-field permits – PMT readout with WLS to clear fiber extension (with lightguide or connector) to out-of- B-field region – APD/SiPM, if B-field is significant and if the radiation allows Based on COMPASS Shashlyk module design. 0.5mm lead/0.12mm air gap/1.5mm scintillator/0.12mm air gap – Assume Lead X 0 =0.56mm, scintillator X 0 =42.4cm, air gap needs to be replaced with actual wrapping or coating. – each layer 2.24mm(0.93X 0 ), total 216 layers, 48.3 cm in length (20 X 0 ) – Reach energy resolution of 5%/sqrt(E) with good linearity – Balance between resolution and longitudinal size 10x10cm of transverse size in square shape – reach 1cm position resolution – Balance between number of modules (cost), position resolution and background – Total about 2000 modules. Splitting : preshower and shower – Maximizing e-pi separation (20: :1 pion rejection depending on momentum) 100 WLS fibers/module – 1/cm 2 fiber density to sample the EM shower – Use KURARAY Y11 for higher radiation hardness and longer attenuation length or use Bicron fibers to save cost. Readout options in orders of preference: – Directly couple to PMT, if B-field permits – PMT readout with WLS to clear fiber extension (with lightguide or connector) to out-of- B-field region – APD/SiPM, if B-field is significant and if the radiation allows

Preshower/Shower Design 1(preferred) Preshower has 1 layer of 11.2mm (2X 0 ) lead as passive radiator and 1 layer of 20 mm scintillator with embedded WLS fiber for readout. – Used by LHCb and Hermes – Good hadron rejection – No change to Shashlyk module prodution – Preshower lead layer work as radiation shielding – Significant reduction of the number of fibers for readout in preshower Preshower (2X 0 lead + scintillator) Shower, 18 X 0, Shashlik Shower WLS fibers Preshower WLS fibers 434.5mm (194 layers)20mm11.2mm100mm ? Total length 569mm ? clear fibers connector Not shown Supporting rod Not shown Supporting rod

Preshower/Shower Design 2 Preshower and shower have separate WLS for readout. Preshower WLS fibers bend and go back from the side. Shower (15X 0 ) Preshower (5X 0 ) – Only small change to current COMPASS module production method – preshower WLS fibers need to have bending radius > 70mm – Radiation damage on the fibers in front, need shielding? 362mm (162 layers) 121mm (54 layers) 100mm ? 70mm? clear fibers connector Not shown Supporting rod Not shown Supporting rod Total length 653mm ?

Preshower/Shower Design 3 Preshower and shower have separate WLS for readout. Preshower WLS fibers go to back through hollow supporting rods. The number of preshower WLS fibers is limited by the hollow rod diameter. Shower Preshower – change to COMPASS module production method – Same or less number of WLS fibers in preshower than shower. – 0.7mm WLS fibers could be use instead of 1mm for preshower – Add more supporting rods to 9 or 16 – Additional mold is required for preshower to allow WLS fibers to sample light – Need more R&D Shower WLS Preshower WLS hollow rod Total length 583mm ?

Preshower/Shower Design 4 Preshower has thin WLS plate for readout and use embedded clear fibers to send signal at back. Shower has WLS for readout. Shower Preshower Pros: – Significant reduce number of fiber for readout in preshower. Concerns – change to COMPASS module production method – No enough light collected by the pad due to light transmission in the thin scintillator layers limited within around 1cm? Shower WLS Preshower Clear fiber WLS plate

SoLID PVDIS

SoLID SIDIS and J/ψ

Large Angle EC We want to cover full azimuthal angle and leave no gap between modules, so module can not be tilted and need to be along Z axis Prefer having short outer module so that the outer module area can cover more and inner module area can cover less Inner module need to be special shape to avoid blocking acceptance. One way to solve it is to have smaller 4x4cm (like COMPASS) module with various length 24 o 14.7 o inner module (160mm in radius) Outer module (500mm in radius) 17.5 o Blue: LAEC acceptance angle Orange : angle between inner and outer 600mm 4x4x43cm 4x4x32cm 4x4x27cm 10x10x60cm module assume 600mm full module length

SoLID Collaboration MeetingJin Huang, Zhiwen Zhao10 Position resolution VS lateral size Blue: calorimeter modules along z axis Red: calorimeter modules along central track Shifted pion ΔR Calorimeter theta angle coverage PVDIS (22-35), SIDIS(8-15,15-24)

LHCb Calorimeter Preshower LHCb used diamond mill to make curvy groove and glue WLS fibers in Can curvy grooves be made with scintillator mold? Will it be cheaper compare to diamond mill cut? Can straight grooves be made with scintillator mold? Will it be cheaper compare to diamond mill cut?

How to bend WLS fibers from preshower scintillator pad? WLS fibers come out of preshower scintillator pad and go back along module for readout. To have large bending angle, let fibers go transversely first and then go longitudinally to back. 100mm 20mm Red: straight part of fiber inside pad Orange: Curvy part of fiber outside pad Assume straight holes

Impact to energy resolution from the passive preshower Simulated with 2 X0 passive radiator and 2 cm scintillator as preshower Minor degrade on energy resolution observed for our energy range Passive preshower + 18 X 0 Shashlyk 20 X 0 Shashlyk

Pion rejection comparisons 1/pion rejection with 94% electron eff. Passive preshower + 18 X 0 Shashlyk 20 X 0 Shashlyk Passive preshower show degrade on pion rejection for higher energy range