ACR Ultrasound PM / Standards

Slides:



Advertisements
Similar presentations
An Indispensable Quality Assurance Tool for Dairy Processing Plants.
Advertisements

Tips to a Successful Monitoring Visit
Quality Management in Diagnostic Imaging
Chapter3 Pulse-Echo Ultrasound Instrumentation
FloormapVS2i.
Gamma Camera Quality Control
PERFORMING EFFECTIVE BUILDING SYSTEM RECOMMISSIONING STUDIES Joseph J. Watson, P.E. Booth # 312.
Grayscale Calibration Grayscale Standard Display Function
RAD 354 Chapt. 30 Digital QC Performance Assessment Standards Luminance Meter Digital Display QC QC by Technologist.
Quality Assurance and Digital Radiography
Radiology Understanding Display Characteristics What You Should Know When Viewing Images from PACS.
고려대학교 구로병원 강 대 현 Goal of Ultrasound QA/QC Program To make sure a system is set up correctly and performs to specified standards. (
Resident Physics Lectures
1 CS 502: Computing Methods for Digital Libraries Lecture 9 Conversion to Digital Formats Anne Kenney, Cornell University Library.
Ultrasound Modes A Mode presents reflected ultrasound energy on a single line display. The strength of the reflected energy at nay particular depth is.
DoD Information Technology Security Certification and Accreditation Process (DITSCAP) Phase III – Validation Thomas Howard Chris Pierce.
Laboratory Personnel Dr/Ehsan Moahmen Rizk.
IS112 – Chapter 1 Notes Computer Organization and Programming Professor Catherine Dwyer 2003.
Detailed Design Review of Magnetic Field Centering Device Project # P08028 “Develop a Design and Methodology to Ensure the Concentricity between the Magnetic.
Ahmed Abdel-Fattah Jerry Chang Derrick Culver Matt Zenthoefer.
QUALITY ASSURANCE IN BLOOD BANKING
Basic quality control tests in medical radiography
Quality Assurance/Quality Control Chapter 10. Quality Assurance Definition A system of activities whose purpose is to provide assurance that the overall.
User Centered Design Lecture # 5 Gabriel Spitz.
IR-CAP Condition Assessment Program Indian Register of Shipping.
By : Alanoud Al Saleh. What is PACS quality control ? The PACS monitor quality control (QC) program objectives are:  to ensure consistent display performance.
Unit IV Analyzing the Image. Unit IV Analyzing the Image.
THE ULTRASOUND IMAGE: GENERATION AND DISPLAY
1 CCTV SYSTEMS TESTING. 2 CCTV SYSTEMS CCTV systems of all sizes are complex video signaling systems, they are subject to many of the same problems found.
 A monitor or display is an electronic visual display for computers.  The monitor consists of : o the display device o circuitry o enclosure The display.
On the Design, Construction and Operation of a Diffraction Rangefinder MS Thesis Presentation Gino Lopes A Thesis submitted to the Graduate Faculty of.
CLINICAL ENGINEERING part(1) Dr. Dalia H. Elkamchouchi CLINICAL ENGINEERING part(1) Dr. Dalia H. Elkamchouchi CLINICAL ENGINEERING part(1)
Occupational Health Programs
Commission on Accreditation for Respiratory Care The Site Visitors Are Coming! Transitioning from Successful Self- Study to Successful Site Visit Bradley.
Commissioning the NOAO Data Management System Howard H. Lanning, Rob Seaman, Chris Smith (National Optical Astronomy Observatory, Data Products Program)
Getting Started with Adobe Photoshop CS6
Introduction to Software Quality Assurance (SQA)
THROUGH PROFICIENCY TESTING
ICAO Aerodrome Safety Workshop Almaty, Kazakhstan – 18 to 22 November 2002  AERODROME MANUAL.
Ensuring Quality in PACS. What is the first thing that comes to mind when you think of quality?
True OMR Second Darkest Mark Detection For Erasure Analysis.
ACR Full-Field Digital Mammography Accreditation Update
 Without reference, identify principles relating to Diagnostic Ultrasound Imaging Calibration with at least 70 percent accuracy.
LASER AND ADVANCES IN METROLOGY
Welcome to the Interactive Survey System. 2 What Is the Interactive Survey System? Online, interactive version of the documents needed for NCQA accreditation,
Product Development Chapter 6. Definitions needed: Verification: The process of evaluating compliance to regulations, standards, or specifications.
Machine Vision Products that IMPACT your Bottom Line! Introducing KickStart!
The Leeds Teaching Hospitals NHS Trust Is Grey the New Black? Image Display Optimisation & Consistency for Softcopy Reporting Mark Barnfield St James’s.
Physical Inventory Why? 1 Barbara A. Finnegan, CPPM CF.
Quality Assurance.
Digital Reformatting of Photographic Formats -2- Aaron Choate Digital Library Production Services The University of Texas Libraries.
Mec-Tric Control Company In Field Valve Testing on SRV’s with on process line AVK pressure device. MEC-TRIC.
Mammography Regulations and Standards in the U.S.: The Basics of the Mammography Quality Standards Act Helen J. Barr, MD Director, Division of Mammography.
Unit IV Ultrasonic examination of welds Foreword.
Safety Management Systems Session Four Safety Promotion APTA Webinar June 9, 2016.
Quality Management for Radiological Equipment
Ultrasound Physics Image Formation ‘97. Real-time Scanning Each pulse generates one line Except for multiple focal zones frame one frame consists of many.
Digital Light Sources First introduced in 2001.
Ultrasound Physics Image Formation ‘97.
Impact of Obesity on Medical Imaging and Image-Guided Intervention
Ultrasound Physics Image Formation ‘97.
Clinical engineering Lecture (7).
Clinical Engineering Lecture (3).
The American College of Radiology Mammography Accreditation
Resident Physics Series
Medical Ultrasound: Image Optimisation
Emulsion Task Force Meeting
First Article Inspection
How to conduct Effective Stage-1 Audit
3. Software Quality Management
Presentation transcript:

ACR Ultrasound PM / Standards

ACR Accreditation This accreditation program involves the following: Acquisition of clinical ultrasound images. Personnel qualifications must be met for both physicians and technologists. The submission of physician reports related to the ultrasound images. Quality Control Program must be in place for each ultrasound system in the facility.

ACR Accreditation Changes New for 2014 Different forms New tests / verifications New mandatory frequency of testing

Sensitivity/Penetration Testing To perform system sensitivity/penetration test, the following parameters should be selected: • Maximum transmit power. • Proper gain and TGC (time gain control) to produce an image in the far field. • Transmit focus set as deep as possible. The maximum depth of visualization represents system’s penetration capability.

Sensitivity/Penetration Testing Measure to the noise floor

Image Uniformity Testing To perform image uniformity test, adjust TGC / DGC and gain settings to obtain an image as uniform as possible. Note on the QC/Preventative maintenance form any of the following: Dropouts Vertical or radial streaks Reduction in brightness near edges of the scan Brightness transitions between focal zones

Image Uniformity Testing Image artifact in near field of probe Probe array? Probe cable? Probe pins/connector? Connector board? Front end board?

NEW: Geometric Accuracy Commonly involves use of the scanner calipers to measure known distances between test targets. Measurement is required only in the mechanically scanned directions The caliper readout of the distance between these two targets agrees to within 1.5 % or 1.5 mm, whichever is greater both axially (vertically) and laterally (horizontally)

Geometric Accuracy

NEW: Scanner Electronic Image Display Performance Display characteristics that are evaluated may include gray scale response and luminance calibration, presence of pixel defects, and overall image quality Completed Not Completed

NEW: Primary Interpretation Display Performance Display characteristics that are evaluated may include gray scale response and luminance calibration, presence of pixel defects, and overall image quality Completed Not Completed N/A (Only required if located at the facility where ultrasound is performed.)

LCD Visual Inspection Brightness. Color clarity. Dead pixels. Details of the image should not be difficult to see or dull. Color clarity. Colors should be brilliant and dissimilar. Dead pixels. Dead pixels are acceptable around the outer perimeter of the screen out of the viewing area. General inspection. Monitor should not have abnormalities in display area. Utilize grayscale bar to ensure all shades of gray are displayed. Whites should be white but not blooming.

Assurance of Electrical/Mechanical Safety Make sure all cords and cables are intact Make sure all transducers are intact without cracks or delaminating Verify all transducers are being cleaned after each use Make sure the image monitors are clean Verify air filters are clean Make sure the wheel locks are in working condition Make sure the wheels are fastened securely to the US unit and they rotate easily Make sure all accessories (VCR, cameras, etc.) are fastened securely to the US unit

New Forms for ACR Compliance Summary page

New Forms for ACR Compliance ACR worksheet page 1

New Forms for ACR Compliance ACR worksheet page 2

Frequency Annual Surveys are complete tests performed once a year by the medical physicist or designee to assess the performance of the equipment. Although the Annual Surveys include all of the same tests conducted during routine QC testing, it is intended to be more extensive. In addition, Annual Surveys include an evaluation of the facility’s routine QC program, if applicable. Routine QC testing is less extensive and is recommended to be performed semiannually by the facility’s sonographer (or a service engineer).

What is the benefit of a Conquest PM?

Customer Interview during a PM Start your PM by talking to the customer and end it with talking to the customer. Make sure you address all of your customer’s concerns before you leave the site. If you have to come back to finish the job, communicate that to the customer.

System Configurations Print/capture DICOM settings Print/capture licensed options/encrypted strings Print/capture system S/N, SW revision, HW revision, system type, supported applications and PCB configuration. Back up user presets and peripheral settings.

Mechanical / Visual Inspection Perform visual inspection on the ultrasound system paying close attention to its user interface, trackball, lights, probes, casters, break assembly and peripherals. Inspect system’s display and peripherals and make sure they are securely attached to the ultrasound unit. Inspect and clean all air filters

Electrical / Safety Inspection

Transducer Leakage

Completing the PM Document the outcomes of the PM. If the PM is not completed because of system/probe concerns, document your recommendations to resolve these issues on the PM report. Fill out a complete PM service report with customer name, system type, and system serial number. Discuss with the customer any items that need further attention Attach a PM verification label to the system Get a customer signature

Questions?