Pumps and Pumping Stations

Slides:



Advertisements
Similar presentations
Fluid Mechanics.
Advertisements

Fluid Mechanics 07.
Booster System Basics: Constant Speed Systems
Pipeline Hydraulics.
Our Plan – Weeks 6 and 7 Review energy relationships in single pipes Extend analysis to progressively more complex systems – Pipes in parallel or series.
Marine Auxiliary Machinery
Operation of Centrifugal pump
CE 230-Engineering Fluid Mechanics
Reynolds Experiment Laminar Turbulent Reynolds Number
Pertemuan CLOSED CONDUIT FLOW 1
Water Pumps turbo-hydraulic pumps, positive-displacement pumps.
Pump Basics. Centrifugal Pumps From the Center of a Circle RADIAL DIRECTION To the Outside of a Circle A machine for moving fluid by accelerating the.
The Centrifugal Pump.
CEE 345, Spring 2012 Part 2: Hydraulics and Open Channel Flow Instructor: Mark Benjamin, 335 More Hall;
Basic Hydraulics Irrigation.
Lesson 26 CENTRIFUGAL PUMPS
Core Ag Engineering Principles – Session 1
1 CTC 450 Pumps Pumps
MER Design of Thermal Fluid Systems Pumps and Fans Professor Anderson Spring Term
Components of Centrifugal pumps
Water piping design.
Lecture 6. Fluid Mechanics
CHAPTER 2: Flow through single &combined Pipelines
1 Pumping Learning Outcomes Upon completion of this training one should be able to: Know what are the key pump components and how they impact pump.
Pumps and Lift Stations. Background Fluid Moving Equipment Fluids are moved through flow systems using pumps, fans, blowers, and compressors. Such devices.
Boundary layer concept
CE 3372 Water Systems Design
Things to grab for this session (in priority order)  Pencil  Henderson, Perry, and Young text (Principles of Process Engineering)  Calculator  Eraser.
Unit: V-Flow Through Pipes. Flow Through Pipes  Major Energy Losses - Darcy-Weisbach Formula - Chezy’s Formula  Minor Energy Losses -Sudden expansion.
Things to grab for this session (in priority order)  Pencil  Henderson, Perry, and Young text (Principles of Process Engineering)  Calculator  Eraser.
General Energy Equation. Chapter Objectives Identify the conditions under which energy losses occur in fluid flow systems. Identify the means by which.
SUBJECT CODE NAME OF SUBJECT TOPIC :::::: FLUID POWER ENGINEERING CENTRIFUGAL PUMP Parul Institute of Engineering & Technology.
PIPE LINE SYSTEM Series Pipe Line System Class I Class II Class III
Urban Storm Drain Design: Pump Performance Curves.
Introduction to Energy Management
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
CE 3372 Water Systems Design
Water Resources System Modeling
Objectives Describe room distribution basics Select diffusers
Things to grab for this session (in priority order)  Pencil  Henderson, Perry, and Young text (Principles of Process Engineering)  Calculator  Eraser.
CENTRIFUGAL PUMPS:- DESIGN & PERFORMANCE Ir. N. Jayaseelan 2012.
Major loss in Ducts, Tubes and Pipes
Chapter 10: Flows, Pumps, and Piping Design
PUMPS Thermal Systems Laboratory Samuel A. Santiago Pérez Modesto González David Alvarado.
Power – Energy Relationships
System One Pumps S1-200 Centrifugal Hydraulics
CENTIFUGAL PUMP OPERATION
II.4.1. Pipe – Pump Systems II Simple Pump in a Pipeline
Chapter 3.
CE 3372 Water Systems Design
CE 3372 Water Systems Design
Deptt. of Irrigation and Drainage Engineering, Dr. PDKV, Akola
EXERCISES Two water reservoirs are connected by a pipe 610m of 0.3m diameter, f’=0.038 and the flow produced by the difference in water surface elevations.
Information the Might be Useful for the Exam
Environmental Engineering CIV2257
Chapter 4. Analysis of Flows in Pipes
Pipe Components, Piping System.
Chapter 16 A: PUMPS AND SYSTEM EFFECTS
Lecture 15 TDH and NPSH Dr. C. L. Jones Biosystems and Ag. Engineering.
Fluid Dynamics for Brewing
Pumps and Lift Stations
Find: Q gal min 1,600 1,800 2,000 2,200 Δh pipe entrance fresh water h
Chapter 5. Pipe System Learning Outcomes:
Review from Lecture 1: Pumps
Review from Lecture 1: Pumps
Review from Lecture 1: Pumps
Performance Curves Dr. C. L. Jones Biosystems and Ag. Engineering.
Pumps and pumping station
Fluid Mechanics Lectures 2nd year/2nd semister/ /Al-Mustansiriyah unv
Presentation transcript:

Pumps and Pumping Stations Pumps add energy to fluids and therefore are accounted for in the energy equation Energy required by the pump depends on: Discharge rate Resistance to flow (head that the pump must overcome) Pump efficiency (ratio of power entering fluid to power supplied to the pump) Efficiency of the drive (usually an electric motor)

Pump Jargon (Total) Static head – difference in head between suction and discharge sides of pump in the absence of flow; equals difference in elevation of free surfaces of the fluid source and destination Static suction head – head on suction side of pump in absence of flow, if pressure at that point is >0 Static discharge head – head on discharge side of pump in absence of flow Static suction head Static discharge head Total static head

Pump Jargon (Total) Static head – difference in head between suction and discharge sides of pump in the absence of flow; equals difference in elevation of free surfaces of the fluid source and destination Static suction lift – negative head on suction side of pump in absence of flow, if pressure at that point is <0 Static discharge head – head on discharge side of pump in absence of flow Static suction lift Static discharge head Total static head

Pump Jargon Static suction head Static discharge head Static suction lift Static discharge head Total static head (both) Note: Suction and discharge head / lift measured from pump centerline

Pump Jargon (Total) Dynamic head, dynamic suction head or lift, and dynamic discharge head – same as corresponding static heads, but for a given pumping scenario; includes frictional and minor headlosses Energy Line Dynamic discharge head Total dynamic head Dynamic suction lift

Example. Determine the static head, total dynamic head (TDH), and total headloss in the system shown below. El = 730 ft ps =6 psig El = 640 ft pd =48 psig El = 630 ft

H-W ‘C’ values are 120 on suction side and 145 on discharge side Example. A booster pumping station is being designed to transport water from an aqueduct to a water supply reservoir, as shown below. The maximum design flow is 25 mgd (38.68 ft3/s). Determine the required TDH, given the following: H-W ‘C’ values are 120 on suction side and 145 on discharge side Minor loss coefficients are 0.50 for pipe entrance 0.18 for 45o bend in a 48-in pipe 0.30 for 90o bend in a 36-in pipe 0.16 and 0.35 for 30-in and 36-in butterfly valves, respectively Minor loss for an expansion is 0.25(v22  v12)/2g Short 30 pipe w/30 butterfly valve El = 6349 to 6357 ft El = 6127 to 6132 ft 30 to 48 expansion 4000of 48 pipe w/two 45o bends 8500of 36 pipe w/one 90o bend and eight butterfly valves

Determine pipeline velocities from v = Q/A.. v30= 7.88 ft/s, v36= 5.47 ft/s, v48= 3.08 ft/s Minor losses, suction side:

Minor losses, discharge side:

Pipe friction losses:

Loss of velocity head at exit: Total static head under worst-case scenario (lowest water level in aqueduct, highest in reservoir): Total dynamic head required:

Pump Power P = Power supplied to the pump from the shaft; also called ‘brake power’ (kW or hp) Q = Flow (m3/s or ft3/s) TDH = Total dynamic head  = Specific wt. of fluid (9800 N/m3 or 62.4 lb/ft3 at 20oC) CF = conversion factor: 1000 W/kW for SI, 550 (ft-lb/s)/hp for US Ep = pump efficiency, dimensionless; accounts only for pump, not the drive unit (electric motor) Useful conversion: 0.746 kW/hp

Diameter D = 48 in; Roughness e = 0.003 ft, Efficiency Pe =80% Example. Water is pumped 10 miles from a lake at elevation 100 ft to a reservoir at 230 ft. What is the monthly power cost at $0.08/kW-hr, assuming continuous pumping and given the following info: Diameter D = 48 in; Roughness e = 0.003 ft, Efficiency Pe =80% Flow = 25 mgd = 38.68 ft3/s T = 60o F Ignore minor losses El = 100 ft 10 mi of 48 pipe, e =0.003 ft El = 230 ft 2 1

Find f from Moody diagram El = 100 ft 10 mi of 48 pipe, e =0.0003 ft El = 230 ft 2 1 Find f from Moody diagram

El = 100 ft 10 mi of 48 pipe, e =0.0003 ft El = 230 ft 2 1

Pump Selection System curve – indicates TDH required as a function of Q for the given system For a given static head, TDH depends only on HL, which is approximately proportional to v2/2g Q is proportion to v, so HL is approximately proportional to Q2 (or Q1.85 if H-W eqn is used to model hf) System curve is therefore approximately parabolic

Example. Generate the system curve for the pumping scenario shown below. The pump is close enough to the source reservoir that suction pipe friction can be ignored, but valves, fittings, and other sources of minor losses should be considered. On the discharge side, the 1000 ft of 16-in pipe connects the pump to the receiving reservoir. The flow is fully turbulent with D-W friction factor of 0.02. Coefficients for minor losses are shown below. K values Suction Discharge 1 @ 0.10 1 @ 0.12 1 @ 0.20 1 @ 0.30 1 @ 0.60 2 @ 1.00 4 @ 1.00 40 ft 6 ft

The sum of the K values for minor losses is 2 The sum of the K values for minor losses is 2.52 on the suction side and 5.52 on the discharge side. The total of minor headlosses is therefore 8.04 v2/2g. An additional 1.0 v2/2g of velocity head is lost when the water enters the receiving reservoir. The frictional headloss is: Total headloss is therefore (8.04+1.0+15.0)v2/2g = 24.04 v2/2g. v can be written as Q/A, and A = pD2/ 4 = 1.40 ft2. The static head is 34 ft. So:

System curve Static head

Pump Selection Pump curve – indicates TDH provided by the pump as a function of Q; Depends on particular pump; info usually provided by manufacturer TDH at zero flow is called the ‘shutoff head’ Pump efficiency Can be plotted as fcn(Q), along with pump curve, on a single graph Typically drops fairly rapidly on either side of an optimum; flow at optimum efficiency known as “normal” or “rated” capacity Ideally, pump should be chosen so that operating point corresponds to nearly peak pump efficiency (‘BEP’, best efficiency point)

Pump Performance and Efficiency Curves Shutoff head Rated capacity Rated hp

Pump Selection

Pump Efficiency Pump curves depend on pump geometry (impeller D) and speed

Pump Selection At any instant, a system has a single Q and a single TDH, so both curves must pass through that point;  operating point is intersection of system and pump curves

Pump System Curve System curve may change over time, due to fluctuating reservoir levels, gradual changes in friction coefficients, or changed valve settings.

Pump Selection: Multiple Pumps Pumps often used in series or parallel to achieve desired pumping scenario In most cases, a backup pump must be provided to meet maximum flow conditions if one of the operating (‘duty’) pumps is out of service. Pumps in series have the same Q, so if they are identical, they each impart the same TDH, and the total TDH is additive Pumps in parallel must operate against the same TDH, so if they are identical, they contribute equal Q, and the total Q is additive Adding a second pump moves the operating point “up” the system curve, but in different ways for series and parallel operation

Example. A pump station is to be designed for an ultimate Q of 1200 gpm at a TDH of 80 ft. At present, it must deliver 750 gpm at 60 ft. Two types of pump are available, with pump curves as shown. Select appropriate pumps and describe the operating strategy. How will the system operate under an interim condition when the requirement is for 600 gpm and 80-ft TDH? TDH (ft) Flow rate (gpm) Pump A only Pump B only System curve Efficiency, % Pump B Pump A 10 100 40 50 30 20 90 80 70 60 120 110 200 400 1200 1000 800 600

Either type of pump can meet current needs (750 gpm at 60 ft); pump B will supply slightly more flow and head than needed, so a valve could be partially closed. Pump B has higher efficiency under these conditions, and so would be preferred. TDH (ft) Flow rate (gpm) Pump A only Pump B only System curve Efficiency, % Pump B Pump A 10 100 40 50 30 20 90 80 70 60 120 110 200 400 1200 1000 800 600

The pump characteristic curve for two type-B pumps in parallel can be drawn by taking the curve for one type-B pump, and doubling Q at each value of TDH. Such a scenario would meet the ultimate need (1200 gpm at 80 ft), as shown below. TDH (ft) Flow rate (gpm) A only B only Two B’s System curve Efficiency, % Pump B Pump A 10 100 40 50 30 20 90 80 70 60 120 110 200 400 1200 1000 800 600

A pump characteristic curve for one type-A and one type-B pump in parallel can be drawn in the same way. This arrangement would also meet the ultimate demand. Note that the type-B pump provides no flow at TDH>113 ft, so at higher TDH, the composite curve is identical to that for just one type-A pump. (A check valve would prevent reverse flow through pump B.) Again, since type B is more efficient, two type-B pumps would be preferred over one type-A and one type-B. TDH (ft) Flow rate (gpm) A only B only Two B’s System curve Efficiency, % Pump B Pump A 10 100 40 50 30 20 90 80 70 60 120 110 200 400 1200 1000 800 600 One A and one B in parallel

At the interim conditions, a single type B pump would suffice. A third type B pump would be required as backup. TDH (ft) Flow rate (gpm) A only B only Two B’s System curve Efficiency, % Pump B Pump A 10 100 40 50 30 20 90 80 70 60 120 110 200 400 1200 1000 800 600 One A and one B in parallel