PARTICIPANTS Co-chairs: Lloyd W. Sumner, The Noble Foundation Teresa W-M. Fan, University of Louisville, KY Contributors: Alexander Amberg, Aventis Dave.

Slides:



Advertisements
Similar presentations
Multipulse techniques
Advertisements

Synthesis and Analysis of Aspirin Chemistry 1060 Laboratory.
Introduction to Chromatography
Gas Chromatography.
RTI International RTI International is a trade name of Research Triangle Institute. NMR Hands On UAB Metabolomics Training Course June 02-05,
HPLC 1. Introduction 1.Introduction CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution.
HPLC Coupled with Quadrupole Mass Spectrometry and Forensic Analysis of Cocaine.
P. 1 FAQs- before analyzing your sample. p. 2  Temperature (thermal degradable?)  Split or splitless  Split ratio  Injection volume FAQs- injection.
NMR Spectroscopy Spectrometer -Hardware
1 NMR Practical Aspects (I) Processes involving in a NMR study: 1. Sample Preparation/Considerations 2. Setting up Spectrometer 3. Setting up acquisition.
In carbon-13 NMR, what do the number of peaks represent?
Proposal for a Standard Representation of the Results of GC-MS Analysis: A Module for ArMet Helen Fuell 1, Manfred Beckmann 2, John Draper 2, Oliver Fiehn.
Chem. 133 – 5/7 Lecture. Announcements I Exam 3 on Tuesday (will give summary of material to know later) Format will be similar to other exams I will.
Analysing the METABOLOME 1.Metabolite Extraction 2.Metabolite Separation 3.Metabolite detection (with or without separation) 4.Data analysis.
Chromatographic detectors for Liquid Chromatography.
FT-NMR.
11 Determination of the Levels of Fungicides on Citrus Fruits By Miseung Borgers Chem 4101, Fall 2008.
LC-MS Lecture 7.
Instant Notes Analytical Chemistry
Synthesis of Oil of Wintergreen
Year 12 Chemistry.  An analytical technique is a method that is used to determine the presence and concentration of a chemical compound or chemical element.
Gas Chromatography And Mass Spectrometry
Gas Liquid Chromatography
Chapter 8 – Mass Spectrometry. Mass Spectrometry The mass spectrometer can be used for: – Quantitative analysis – as a sophisticated and very sensitive.
Mass Spectrometry Mass spectrometry (MS) is not true “spectroscopy” because it does not involve the absorption of electromagnetic radiation to form an.
Principles of Chromatography. Chromatography is the most powerful tool for separating & measuring the components of a complex mixture. Quantitative &
Physical Chemistry 2 nd Edition Thomas Engel, Philip Reid Chapter 28 Nuclear Magnetic Resonance Spectroscopy.
High Performance Liquid Chromatography
By: Thilag.k & Stephen. What is Hpcl??? Hplc or high performance liquid chromatography is the most widely used analytical separation technique. The difference.
Year 12 Chemistry Unit 3 – AOS 1 Chemical Analysis.
ONS Challenge: Solubility Determination of Carboxylic Acids in Chloroform using 1 H NMR and External Water Standard David Bulger 1, Andrew Lang, Ph. D.
Chromatography (Separations) Mass Spectrometry Infrared (IR) Spectroscopy Nuclear Magnetic Resonance (NMR) Spectroscopy X-ray Crystallography (visual solid.
Peak-purity by LC-MS and LC-DAD Knut Dyrstad Erlend Hvattum Sharon Jara Arnvid Lie.
Nuclear Magnetic Resonance ANIMATED ILLUSTRATIONS MS Powerpoint Presentation Files Uses Animation Schemes as available in MS XP or MS 2003 versions A class.
Mass spectrometry session. Summary Fiehn (1) Standardization important Reporting important, but has to be feasible Does not matter which MS instrument.
INTRODUCTION TO CHROMATOGRAPY
10 – Experimental aspects of NMR 1.The NMR tube 2.NMR solvents 3.The sample 4.How much time does an NMR experiment require? 5.Line shape 6.NMR coils 7.Shimming.
Quality Assurance How do you know your results are correct? How confident are you?
Advanced Analytical Chemistry – CHM 6157® Y. CAIFlorida International University Updated on 9/26/2006Chapter 3ICPMS Interference equations Isobaric.
HPLC – High Performance Liquid Chromatography
液相層析質譜分析 LC-MS Method development and Analyte Identification 授課教師:賴滄海教授 授課教師:賴滄海教授
1 NMR Samples Types of NMR tubes Sample preparation.
Stability Indicating Assays for Dose Formulation Stability Testing Teresa Fuller GSK.
HPLC.
Chapter 28 High Performance Liquid Chromatography.
Nuclear Magnetic Resonance
1 Chapter 2 Steps in a chemical analysis Plan of analysis Before doing any quantitative analysis, the following questions should be answered: 1-
HPLC.
Why HPLC? Almost universal applicability Remarkable precision Highly commercially available (competition)
Claridge Chapter 8. NOE Transient NOEs In standard 1D NOE, one resonance is saturated, and the system must respond to return to equilibrium by the W0.
Lecture 8 Peak Parameters and Quantitative chromatography
Chem. 133 – 5/3 Lecture. Announcements Lab – Term Project Progress Report Due Today – Last Assignments: Term Project Poster and Peer Review Grading (Friday,
Instrumental Analysis
이 장 우. 1. Introduction  HPLC-MS/MS methodology achieved its preferred status -Highly selective and effectively eliminated interference -Without.
Protein NMR IV - Isotopic labeling
Multi-Analyte LC-MS/MS Methods – Best Practice.
Chem. 133 – 5/2 Lecture.
James Byrd, Marta Kozak 28 Apr 2011
Chem. 133 – 4/27 Lecture.
Analytical Chemistry II ChEm 321
Chem. 133 – 4/18 Lecture.
A sensitive and repeatable method for characterization of sulfonamides and trimethoprim in honey using QuEChERS extracts with Liquid-Chromatography-Tandem.
Chem. 133 – 4/20 Lecture.
High Performance Liquid Chromatography HPLC
Metabolomics Part 2 Mass Spectrometry
Pure Carrier Gas Grades (subjective)
High Performance Liquid Chromatography
Mass Spectrometry THE MAIN USE OF MS IN ORG CHEM IS:
Transferring LC-UV to LC-MS.
Damiana Gentili Qualified Person/QU Director 09/05/2019
Presentation transcript:

PARTICIPANTS Co-chairs: Lloyd W. Sumner, The Noble Foundation Teresa W-M. Fan, University of Louisville, KY Contributors: Alexander Amberg, Aventis Dave Barrett, Univ. of Nottingham Mike Beale, MetRo Clare Daykin, Univ of Nottingham Oliver Fiehn, UC Davis Jules Griffin, Cambridge Richard Higashi, UC Davis Joachim Kopka, Max Planck MPI John Lindon, Imperial College Andrew Lane, Univ. of Louisville Andrew Nicholls, GSK Michael Reily, Pfizer

Chemical Analysis Working Group GOALS The scope of our efforts will be to identify, develop and disseminate best chemical analysis practices in all aspects of metabolomics. From best practices formulate a minimum set of reporting standards that describe the experiments

work cooperatively on a consensus draft for a minimum core set of necessary data related to the chemical analyses associated with metabolomics experiments include key persons from the Group’s specialist area to participate in the discussion in an inclusive manner. reach out and evaluate previous and relevant work in their specialist areas including similar work in transcriptomics and proteomics studies, and recent metabolomics standardization efforts. pay careful attention to the distinction of best practice (which will change), reporting standards (which should have longer validity) and data exchange standards (which support reporting). respond to documents from the other groups and produce an advanced draft ready for discussion in February 2006 respond to documents from the other groups and produce a final draft ready for discussion in June 2006 Involve jounal editorial boards of Metabolomics, Phytochemistry, Analytical Chemistry, analytical biochemistry, and relevant life sciences to review and advise on the practicality, acceptability, and support of standards. Chemical Analysis Working Group Specific Objectives

Scope of Chemical Analysis WG 4.0 Proposed Minimum Metadata for Sample Preparation 4.1 Proposed Minimum Metadata Relative to Chromatography 4.2 Proposed Minimum Metadata Relative to Mass Spectrometry 4.3 Proposed Minimum Metadata Relative to Metabolite Identification 4.4 Proposed Minimum Metadata Relative to Nuclear Magnetic Resonance 4.5 Proposed Minimum Metadata Relative to Stable Isotopes & Flux Analysis ? 4.7 Proposed Minimum Metadata Relative to Capillary Electrophoresis 4.8 Proposed Minimum Metadata Relative to Electrochemical Detection 4.9 Proposed Minimum Metadata Relative to Infrared Spectroscopy 4.10 Proposed Minimum Metadata for Data Export 4.11 Proposed Minimum Metadata for Quantification

4.0 Proposed Minimum Metadata for Sample Preparation Sample Processing protocol –Harvesting method: sample freezing method (e.g. LN2, dry ice acetone bath, freeze clamping), sample wash method for removing unwanted external components, time & duration, to include time (e.g. from tissue resection to LN2 freezing), temp, sample storage prior to further preparation (e.g. -80C for 2 weeks). All temperatures should be measured if possible; however temp setpoints are acceptable assuming quality monitoring was performed and no abnormalities recorded. –Tissue processing: lyophilization, fresh tissue processing, pulverization (e.g.. LN2 grinding, dry tissue homogenization, expected particle sizes), storage conditions (e.g. -80°C, duration, atmospheric or vacuum, dessication, preservatives), dilution… Extraction solvent and volume per quantity tissue, number of sequential/parallel extraction –1ml MeOH per 6mg lyophilized tissue, twice extraction, CHCl3/MeOH (2/1, v/v) followed by 10% trichloroaectic acid extraction

Extract concentration, and resuspension processes –Dried under nitrogen, resuspended in H2O or pyridine, Sample enrichment (if relevant) –SPE (column, sorbent, manufacturer) –Desalting, MWCO etc. Derivatization –OMS/TMS (temperatures & duration) Extract cleanup & additional manipulation –e.g. Ultrafiltration, removal of paramagnetic ions, addition of metal chelators such as EDTA, citrate, pH buffer Extract storage –Storage conditions prior to analysis Ionic strength & conductivity ??? 4.0 Proposed Minimum Metadata for Sample Preparation

4.1 Proposed Minimum Metadata for Chromatography Chromatography Instrument –Manufacturer, model number, software package and version number or date, Auto-injector –Injector model/type, software version, method name, injection volume, wash cycles (volumes); solvent, split/splitless Separation column and pre/guard column –manufacturer, product #, stationary media composition (support and coating e.g. silica C8 etc) & physical parameters (i.e. coating thickness for GC/MS & particle size and pore size for LC/MS), internal diameter, length Separation parameters –Method name, injector temperature, split or splitless mode & ratio, mobile phase compositions, mobile phase flow rates, thermal/solvent/solute gradient profiles, Quality Control to validate chromatography performance –Minimum should include description whether or not QC was performed and how it was measured –Validation sample, internal standards, chromatographic resolution, cycles per column/injector/septum/blank, calibration standards –Data acquisition –SOP Protocol name, date, and publication reference (can be journal or website URL but should be publicly accessible and link should be stable.

4.2 Proposed Minimum Metadata for Mass Spectrometry Instrument –manufacturer, model #, operational software name & version Ionization source –Ionization mode (EI, APCI, ESI….), polarity, vacuum pressure, skimmer/focusing lens voltages (e.g. capillary voltage etc.), gas flows (e.g. nebulization gas, cone gas etc., source temperature Mass Analyzer –Type, m/z range, calibration, resolution, mass accuracy, logic program for data acquisition, spectral acquisition rate, vacuum pressure, lock spray (concentration, lock mass, flow rate, frequency tec) Quality Control –Tune, sensitivity, mass accuracy, and resolution Data acquisition –SOP Protocol name, date, operator, data acquisition rate

4.3 Proposed Minimum Metadata for Metabolite Identification Most metabolites are not novel identifications (i.e. previously characterized & identified using high rigor) Propose a minimum of two independent domains relative to an authentic compound for metabolite identifications (retention time & mass spectrum- unit res molecular ion, or high res. Mass or fragmentation pattern?), (retention time & chemical shifts), (accurate mass & tandem MS), (retention time & UV spectrum) More than two adds additional confidence (Rt, m/z, UV, chemical shift- one chemical shift is not very good- needs more detail such as multiplicity, 2D connectivity, etc) Reporting of chemical identifiers & nomenclature: INCHE, SMILES, IUPAC name, Common names Unknown identifiers & nomenclature?

4.4 Proposed Minimum Metadata for NMR Instrument –manufacturer, model #, magnetic field strength in Tesla {example 14.1 T Varian Inova ; 18.8 T Bruker Avance} Hardware VT control, pulsed field gradients (z or x,y,z) and max gradient strength; no. shims, no channels; Probe type (e.g. 10 mm 31P, 5 mm HCN coldprobe, 3 mm flow-probe, etc.), solution or solid-state, automation or manual operation, autotune or manual tune. LC-NMR: sample handler, injection volumes, wash cycles & solvent Sample property Temperature, Volume, extract/powder/intact organisms, tissue or cells, type of NMR tube (e.g. conventional, Shigemi,, mircocell etc. ), pH, solvent (D2O, CD3OD, CDCl3, etc) Acquisition & Data Processing Parameter For 1-D NMR: observed nucleus, pulse sequence name, pulse sequence implementation (e.g. gradient selection, sensitivity enhancement), spinning rate, solvent saturation or decoupling method, excitation pulse width, spectral width, acquisition time, interpulse delay (or recycle time), digitization parameter, number of transients For solvent suppression, technique, excitation maximum and bandwidth should be stated. Additional parameters for 2-D NMR: observed nucleus in F2 and F1, pulse sequence, excitation pulse widths for relevant nuclei, spectral width in F2 and F1, solvent saturation method, number of transients in t2 and number of increments in t1, acquisition times for t2 and t1 ; phase sensitive or magnitude detection

4.4 Proposed Minimum Metadata for NMR For homonuclear NMR, presence or absence of heteronuclear decoupling (e.g. isotope- enriched samples), decoupling mode and bandwidth; spin lock field strength (in Hz) and duration (in sec); mixing time (NOESY, ROESY etc.) For heteronuclear NMR: direct or indirect detection; proton decoupling mode (Waltz, Garp, Wurst, Stud etc.) and effective band width ; evolution time for constant time experiments; editing mode (cf. INEPT-based experiments); heteronuclear spin lock strength and mixing time (e.g. HCCH-TOCSY) Data Processing: Degree of zero filling, degree of linear prediction; apodization parameters and window function in all dimensions (exponential, Gaussian, sine bell etc). Baseline corrections (dc offset, linear or non-linear corrections), first point multipliers, any shifting of the fids. Quality Control Calibration (chemical shift & concentration) standard used (e.g. DSS, TMS), duplications, standard error/deviation of quantification. State the 50% and 1% line widths on the reference (cf. DSS, TSP or TMS methyl peak) or residual water, pH marker used & shift correction. For X nuclei, external or internal reference and conditions, correction made for susceptibility effects. Shift referencing method for indirect dimension in 2D experiments (direct or indirect based on g ratios). For quantitation, state method used (peak integration or deconvolution method, spiking with substance x at relative concentration y; intensity normalized to reference line- correction for saturation effects- T1 values measured?). Any relaxation agents added (type, amount). For direct X-detection (esp. 13C or 31P), correction for NOEs as well as saturation? For light water samples, what corrections are made for non-linear excitation profile and method?

4.5 Proposed Minimum Metadata for Stable Isotopes & Flux Analysis Labeled precursors used including element/isotope, position(s) labeled, % e.g. [13C-1]-D-glucose 98%, [15N2]-L- glutamine (99%), chemical purity of the labeled compound(s), and concentration of the compound used in the experiment; fraction of total present (requires detailed breakdown of media composition for cell and tissue studies, including analysis of any added FCS or other growth supplements; labeling scheme (duration, pulse or continuous addition; top up etc.) Total no. moles isotope added during the experiment. Data analysis: method for determining positional and fractional labeling, standard error of the estimates; estimated isotope recovery in observable fractions (and fraction of total isotope supplied)

Additional topics under consideration 4.7 Proposed Minimum Metadata for Capillary Electrophoresis ? 4.8 Proposed Minimum Metadata for Electrochemical Detection ? 4.9 Proposed Minimum Metadata for Infrared Spectroscopy ? 4.10 Proposed Minimum Metadata for Data Export? 4.11 Proposed Minimum Metadata for Quantification?