Design Overview: Active Transmitting RF tag (2.45 GHz) Bracelet Antenna Array + Accelerometer Three antennas measure received signal strength from transmitter.

Slides:



Advertisements
Similar presentations
Outline quad-copter Abstract Quad-Copter Movement Hand movement
Advertisements

Fundamentals of Data & Signals (Part II) School of Business Eastern Illinois University © Abdou Illia, Spring 2015 (February18, 2015)
Sponsored by: Dept. of Veterans Affairs Group #5 Samuel Rodriguez Daniel Thompson Chadrick Williams Giselle Borrero.
Technician License Course Chapter 3 Types of Radios and Radio Circuits Module 7.
GPS-less Low-Cost Outdoor Localization for Very Small Devices Nirupama Bulusu, John Heidemann, and Deborah Estrin.
Doc.: IEEE /0630r0 Submission May 2015 Intel CorporationSlide 1 Verification of IEEE ad Channel Model for Enterprise Cubical Environment.
224 Final Project Kendra Armstrong - Nick Eccles - Cary Maguire - Alex Taam - Paul Williams.
Integrated Circuits Design for Applications in Communications Dr. Charles Surya Department of Electronic and Information Engineering DE636  6220
Wearable Speech Enhancement Team Members: Brandon Mikulis Carl Audet John Dimmick Advisor: Dr. Amuso Coordinator: Professor Slack.
Cycling Timing System SDP /10/03 Patrick Bell Emilio Gaudette Eric Johnson Advisor: Ramakrishna Janaswamy.
TPS: A Time-Based Positioning Scheme for outdoor Wireless Sensor Networks Authors: Xiuzhen Cheng, Andrew Thaeler, Guoliang Xue, Dechang Chen From IEEE.
Technician License Course Chapter 3 Types of Radios and Radio Circuits Module 7.
1 Advanced Sensors Lecture 6 Sensors Technology AUE 2008 Bo Rohde Pedersen.
RADAR: An In-Building RF-Based User Location and Tracking system Paramvir Bahl and Venkata N. Padmanabhan Microsoft Research Presented by: Ritu Kothari.
University of Pennsylvania Department of Electrical and Systems Engineering ABSTRACT: Quantifying and measuring certain aspects of a golf swing is a helpful.
P13071 – Non-Invasive Blood Glucose Monitor Team Members Jared Bold Yongjie Cao John Louma Andrew Rosen Dan Sinkiewicz Faculty Advisor Professor George.
Presented by: Xi Du, Qiang Fu. Related Work Methodology - The RADAR System - The RADAR test bed Algorithm and Experimental Analysis - Empirical Method.
RFID-Based Blood Pressure Monitor Location and Movement Sensor IEEE Phoenix Senior Design Project, Spring 2014 Larry Beaty Copyright.
Creating Waypoints and Determining Accuracy Using GPS Testing Accuracy of the GPS Using Waypoints Using a Garmin GPS, we chose three objects to use as.
Senior Project – Computer Engineering Integrated Workout Shoe Peter Katlic Advisor – Prof. Cotter Development: Consisting of an 8051 microcontroller.
We are Group5 Weatherstation The team Members are : Saran Jackson Robert Howard Robert Garvey Gene Fitzgerald Steven Dowling.
SCADA and Telemetry Presented By:.
Automatic Directional Antenna Azimuth Controller Cezanne Camacho, Andrew Curtis, and Tyler Bowen Department of Electrical Engineering, University of Washington,
General Licensing Class G7A – G7C Practical Circuits Your organization and dates here.
Motion Capture Hardware
Peripherals and their Control An overview of industrially available “peripheral devices” that use “pulse-width modulation” for information passing. Review.
Smart transmitters.
Disc Golf Disc Locator Trevor Henry Project Advisor: John Spinelli.
Copyright ©2011 by Pearson Education, Inc. publishing as Pearson [imprint] Introductory Circuit Analysis, 12/e Boylestad Chapter 21 Decibels, Filters,
Final year Project 2006/07 Microcontroller and RF application for wearable power generators By Jeanette Mannion.
Sérgio Ronaldo Barros dos Santos (ITA-Brazil)
Sponsored by: Dept. of Veterans Affairs Group #5 Samuel Rodriguez Daniel Thompson Chadrick Williams Giselle Borrero.
IEEE Phoenix Senior Design Project, Spring 2011 Blood Pressure Sensor Accuracy and Precision Requirements Larry Beaty Steven James Michael.
Certified Wireless Network Administrator (CWNA) PW0-105 Chapter 2 Radio Frequency Fundamentals.
 Adviser : Dr. Lei Ying  Research Assistant: Ming Ouyang  Team Members:  Prashanth Yanamandra  Wyatt Brenneman  Taylor McKechnie  Client: ECpE.
Location Estimation in Ad-Hoc Networks with Directional Antennas N. Malhotra M. Krasniewski C. Yang S. Bagchi W. Chappell 5th IEEE International Conference.
Fig. 3 Wind measurements experimental setup Lidar (light detection and ranging) operates using the same concept of microwave RADAR, but it employs a lot.
1 Detection of Cellular Activity Within A Defined Space Undergraduate Project – Final Presentation Spring 2008 Doron BrotEyal Cimet Supervisor:Yossi Hipsh.
College of Engineering Anchor Nodes Placement for Effective Passive Localization Karthikeyan Pasupathy Major Advisor: Dr. Robert Akl Department of Computer.
RADAR: an In-building RF-based user location and tracking system
Programmable Biofeedback Chest Exerciser Eileen Bock, Lauren Cassell, Margaret Gipson, Laurie McAlexander Department of Biomedical Engineering, Vanderbilt.
Abstract Inexpensive ultrasonic tape measures are available that can only measure perpendicular distances to fairly large, flat surfaces. Complex environments.
ECE 192: NATCAR Team (Triton X) Sponsored by IEEE ( Vincent Bantigue, Joseph Formanes,
Doc.: IEEE /0632r0 Submission May 2015 Intel CorporationSlide 1 Experimental Measurements for Short Range LOS SU-MIMO Date: Authors:
EE 4BD4 Lecture 14 Position Sensors 1. Types of Sensors Potentiometers and linear resistors Capacitive sensors (mm distances, e.g. capacitive microphone)
The Cricket Compass for Context-Aware Mobile Applications
Clint Miller KCØJUO and Paul Cowley KB7VML Story County ARES January 16 th, 2016.
Introduction It’s a part of an electronic prototype that operate in MICS band Used to transfer information's regarding the patient during and after the.
Nissanka Bodhi Priyantha Computer Science, Massachusetts Institute of Technology RTLab. Seolyoung, Jeong Dissertation, MIT, June 2005.
Antenna Arrays and Automotive Applications
Electric Air Ukulele Ivan Setiawan (setiawa2) Satyo Iswara (iswara2) ECE 445 Senior Design Spring 2012 Team #32 TA: Jane Tu.
Date of download: 6/23/2016 Copyright © 2016 SPIE. All rights reserved. A schematic design of the all-dielectric polymer waveguide E-field sensor (a).
Spectrum Policy Technological Solutions for Policy Problems Allen Petrin ©2003 all rights reserved 1 System Architecture for a Dynamic-Spectrum.
PRESENTATION CSE 341 MICROPROCESSOR Presented By Nabid Kaisar
GloveFX Patent Liability Ryan DeFord Fred Grandlienard Kevin Mohr Andrew Gregor.
Modulation and Multiplexing Broadband Transmission – A carrier is a high frequency signal that is modulated by audio, video, or data. – A radio-frequency.
The Life Bracelet Heart rate and rhythm sensor worn on the wrist with Bluetooth connection to smartphone. Real-time monitoring with intervention according.
PATIENT MONITORING SYSTEMS
CMS:Children Monitoring System
(2) Bridge Circuits.
Textbook Detection System With Radio-Frequency Identification
Radio Frequency Readout Device (RFRD)
Andrew mortallero, Irene ng January 23, 2014
WIRELESS ENERGY MEASUREMENT SYSTEM
MICROSECOND TIME KEEPING TO IMPROVE POWER SYSTEM CONTROL & OPERATION
Modular Motion Tracking Device
Fundamentals of Data & Signals (Part II)
Calculating Averages with
Modular Motion Tracking Device
Wireless Electrocardiogram System Senior Project
Presentation transcript:

Design Overview: Active Transmitting RF tag (2.45 GHz) Bracelet Antenna Array + Accelerometer Three antennas measure received signal strength from transmitter Reference table from testing determines linear distance Angle of accelerometer and distance used to calculate height Transmitter: The transmitter is implemented with an Atmel ATAVRRZRAVEN development board that continuously broadcasts a 2.4GHz radio signal. Receiver Array: The receiver array is a bracelet containing 3 antennas that are 60 degrees apart from one another and an Adafruit Industries ADXL335 3-axis accelerometer. Each antenna is connected to an Analog Devices AD8313 Logarithmic Amplifier that measures the signal strength of the radio frequency obtained by the antenna and outputs a corresponding DC voltage. DESIGN OVERVIEW GOAL l RF-Based Blood Pressure Monitor Location Sensor Students: Jordan Lippitt, Mic Johnson, Ming Dai, Pat Benike, and Thai Pham Advisors: Professor Paul Ruden and Larry Beaty (IEEE Phoenix Project) The University of Minnesota Chronobiology Center has found that through continuous monitoring of blood pressure, Vascular Variability Disorders (VVDs) can be detected and treated early before they result in events such as heart attack or stroke. Members of the Twin Cities IEEE Phoenix Project are currently in the process of developing a wrist- worn blood pressure monitor (BPM) that can be worn continuously over the course of a week to monitor the cyclical nature of one’s blood pressure. The major drawback of current wrist-worn BPMs is that they require users to keep their wrist level with their heart at all times in order to generate accurate readings. This is not practical because it becomes nearly impossible for the user to comfortably wear the BPM continuously over the course of a week. Our design combines the functionality of radio frequency technology with an accelerometer to calculate the orientation of the wearer's wrist with respect to their heart, and the linear distance between them. The height between the heart and the wrist can be calculated with these variables and then applied to adjust the incorrect measurements recorded by the BMP. Chronobiology is the study of biological rhythms. Blood pressure has a 24 hour rhythm. When measured every 30 minutes for 7 days straight, vascular variability disorders can be detected. Vascular Variability Disorders can predict morbidity events like a strike or heart attack. They can only be detected by continuously monitoring blood pressure. The goal of the Phoenix Project is to improve on the design of current wrist-worn blood pressure monitors (Figure 1) to make them affordable, robust, and able to take accurate blood pressure measurements every 30 minutes for a week. Wrist-worn blood pressure monitors that are held at a different height than the heart will give an inaccurate measurement. Fictitious example of continuous monitoring shown below. Continuous monitoring allows for the detection of Vascular Variability Disorders (VVD’s): Experiment Setup/Results: The RF transceiver, embedded in a development board, is configured to transmit an RF signal continuously. The board is placed in parallel with the receiver, and the signal strength received by the antenna at specific distance is recorded to establish a reference table. Accomplishments: Determine distance accurately when the arm was within 40 centimeters of the active tag Determine orientation of the wrist with respect to the heart Future Recommendations/Tasks: Use phase of arrival rather than received signal strength to determine distance Replace the active tag with a passive one to reduce design cost Scale down the size of the system Increase number of antennas Improve accuracy of the measurements Acknowledgements: Professor Robert Sainati Professor Anand Gopinath Larry Beaty Figure 1: Picture of current wrist-cuff blood pressure monitors. BPM is accurate if at the same height as the heart BPM is inaccurate if not at the same height as the heart To design a sensor that uses radio frequency technology to calculate the difference in height between one’s wrist and his or her heart. INTRODUCTION l THE PHOENIX PROJECT l MEASURING DISTANCE l TEST RESULTS l FINDINGS l