Scanning Probe Microscopy

Slides:



Advertisements
Similar presentations
AFM Basics Xinyong Chen.
Advertisements

Scanning Tunneling Microscope (STM) and Atomic Force Microscope (AFM)
Atomic Force Microscope (AFM)
Scanning Probe Microscopy ( STM / AFM )
Scanned-proximity Probe Microscopy (SPM) Background Emphasis on Atomic Force Microscopy (AFM) Reading SPM Features AFM Specifics AFM Operation (Conceptual)
Atomic Force Microscopy Andrew Rouff and Kyle Chau.
The Principle of Microscopy : SEM, TEM, AFM
SCANNING PROBE MICROSCOPY By AJHARANI HANSDAH SR NO
Lecture 10. AFM.
Force Microscopy Principle of Operation. Force Microscopy Basic Principle of Operation: detecting forces between a mass attached to a spring (cantilever),
Nanomechanical Detection of Living Cell Surface April 10, 2006 Joseph Abel USU Dept of Physics Living SH-SY5Y Neuroblastoma Cell
Imaging of flexural and torsional resonance modes of atomic force microscopy cantilevers using optical interferometry Michael Reinstaedtler, Ute Rabe,
Basic Imaging Modes Contact mode AFM Lateral Force Microscopy ( LFM)
Sample laser cantilever quadrant photodetector tip AFM measures x, y, and z dimensions. The AFM works by scanning a silicon or silicon nitride tip, with.
Spectroscopic Techniques for Probing Solid Surfaces Part II of Surface Primer.
Muhammad Khurram Farooqi (CIIT/FA11/MSPHY/006/LHR) Department of Physics CIIT Lahore 1 Scanning Probe Microscopy Submitted by Report ( Submitted to) Dr.
UNIT IV LECTURE 61 LECTURE 6 Scanning Probe Microscopy (AFM)
STM / AFM Images Explanations from
Atomic Force Microscopy
Get to the point!. AFM - atomic force microscopy A 'new' view of structure (1986) AlGaN/GaN quantum well waveguide CD stamper polymer growth surface atoms.
Atomic Force Microscop (AFM) 3 History and Definitions in Scanning Probe Microscopy (SPM) History Scanning Tunneling Microscope (STM) Developed.
Atomic Force Microscopy
Copyright © 2005 SRI International Scanning Probe Microscopy “Seeing” at the nanoscale.
Scanning Probe Microscopy (SPM) Real-Space Surface Microscopic Methods.
آشنایی با میکروسکوپ نیروی اتمی Dr. Janelle Gunther March 10, 1998 ACS Group and MENs, Beckman Institute adapted from the world wide web page at
BMFB 3263 Materials Characterization Scanning Probe Microscopy & Relates Techniques Lecture 5 1.
Nano-technology and Nano-electronics
Scanning Tunneling Microscopy and Atomic Force Microscopy
Methods and Tehniques in Surface Science
Auger electron spectroscopy is a surface sensitive analytical technique used mainly to determine elemental compositions of material and, in certain cases.
TAPPINGMODE™ IMAGING APPLICATIONS AND TECHNOLOGY
UIC Atomic Force Microscopy (AFM) Stephen Fahey Ph.D. Advisor: Professor Sivananthan October 16, 2009.
Tuning Fork Scanning Probe Microscopy Mesoscopic Group Meeting November 29, 2007.
What has enabled Nanoscience? Advances in Computing Power New Generation of Scientific Instruments Scanning Probe Microscopes An incomplete list.... Very.
FNI 1A1 Scanning Probe Microscopes SPM History of scanning probe microscopes SPM System Overview Piezoelectric Effect Scanning Tunneling Microscope (STM)
NANO 225 Micro/Nanofabrication Characterization: Scanning Probe Microscopy 1.
Introduction to Atomic Force Microscopy
AFM. The cantilever holder The cantilever dimensions Tip position.
Tutorial 4 Derek Wright Wednesday, February 9 th, 2005.
Common scanning probe modes
Scanning Probe Microscopy Colin Folta Matt Hense ME381R 11/30/04.
Today –Homework #4 Due –Scanning Probe Microscopy, Optical Spectroscopy –11 am NanoLab Tour Tomorrow –Fill out project outline –Quiz #3 in regular classroom.
5 kV  = 0.5 nm Atomic resolution TEM image EBPG (Electron beam pattern generator) 100 kV  = 0.12 nm.
School of Mathematical and Physical Sciences PHYS August, PHYS1220 – Quantum Mechanics Lecture 6 August 29, 2002 Dr J. Quinton Office: PG.
Atomic Force Microscopy (AFM)
Electric Force Microscopy (EFM)
Atomic Force Microscopy Alexander Chew Florida State University BSC5936 April 2005.
Fachgebiet 3D-Nanostrukturierung, Institut für Physik Contact: Office:
EEM. Nanotechnology and Nanoelectronics
SPM Users Basic Training August 2010 Lecture VIII – AC Imaging Modes: ACAFM and MAC Imaging methods using oscillating cantilevers.
Atomic Force Microscopy (AFM)
Scanning Tunneling Microscopy Adarsh Pyarelal Department of Physics Reed College Portland, Oregon, USA.
Scanning Probe Microscopy
Pooria Gill PhD of Nanobiotechnology Assistant Professor at MAZUMS In The Name of Allah.
Get to the point!.
Get to the point!.
Molecular spectroscopy and reaction dynamics Group III
Scanning Probe Microscopy: Atomic Force Microscope
Scanning Tunneling Microscopy
Scanning Probe Microscopy
Characterization of CNT using Electrostatic Force Microscopy
Scanning Probe Microscopy History
7x7 surface have been removed and deposited.
Scanning Probe Microscopy History
Atomic Force Microscopy Samrat Dutta, Ph.D.
NANO 230 Micro/Nano characterization
Square Barrier Barrier with E>V0
Scanning Probe Microscopy
Atomic Force Microscope
Atomic Force Microscopy
Presentation transcript:

Scanning Probe Microscopy Binnig & Rohrer Nobel prize 1986

SPM Principles All of the techniques are based upon scanning a probe just above a surface whilst monitoring some interaction between the probe and the surface. The interaction that is monitored in: STM - is the tunnelling current between a metallic tip and a conducting substrate which are in very close proximity but not actually in physical contact. AFM - is the van der Waals force between the tip and the surface; this may be either the short range repulsive force (in contact-mode) or the longer range attractive force (in non-contact mode).

SPM For the techniques to provide information on the surface structure at the atomic level: the position of the tip with respect to the surface must be very accurately controlled (to within about 0.1 Å) by moving either the surface or the tip. It is possible to accurately control the relative positions of tip and surface by ensuring good vibrational isolation of the microscope and using sensitive piezoelectric positioning devices. the tip must be very sharp - ideally terminating in just a single atom at its closest point of approach to the surface.

STM If the tip is biased with respect to the surface, electrons can tunnel between the two, provided the separation of the tip and surface is sufficiently small - this gives rise to a tunnelling current. The direction of current flow is determined by the polarity of the bias. If the sample is biased -ve with respect to the tip, then electrons will flow from the surface to the tip, whilst if the sample is biased +ve with respect to the tip, then electrons will flow from the tip to the surface.

STM Quantum mechanical tunnelling permits particles to tunnel through a potential barrier which they could not surmount according to the classical laws of physics. The probability of tunnelling is exponentially-dependent upon the distance of separation between the tip and surface : the tunnelling current is therefore a very sensitive probe of this separation.

STM Modes Imaging of the surface topology may then be carried out in one of two ways: in constant height mode A plot of the tunnelling current v's tip position therefore shows a periodic variation which matches that of the surface structure. in constant current mode Normal way of imaging the surface is to maintain the current constant whilst the tip is scanned across the surface by adjusting the tip's height above the surface so that the tunnelling current does not vary with the lateral tip position. The image is then formed by plotting the tip height (strictly, the voltage applied to the z-piezo) v's the lateral tip position.

STM Links & Images Scanning Tunneling Microscopy Tutorial IBM STM Gallery Veeco Nanotheatre Nickel (110) Xenon on Nickel (110) When you look through the hole in the xenon atom you see a nickel atom located directly beneath. Evidently, xenon binds to the on-top site.

More Xenon on Nickel (110) HOPG

AFM 1. Laser 2. Mirror 3. Photodetector 4. Amplifier 5. Register 6. Sample 7. Probe 8. Cantilever An atomically sharp tip is scanned over a surface with feedback mechanisms to maintain the tip at a constant force (to obtain height information), or height (to obtain force information) above the sample. Tips are typically made from Si3N4 or Si, and extended down from the end of a cantilever. A diode laser is focused onto the back of the reflective cantilever. As the tip scans the surface of the sample, moving up and down with the contour of the surface, the laser beam is deflected into a dual element photodiode which measures the difference in light intensities between the upper and lower photodetectors, and then converts to voltage.

AFM Resolution depends on the tip sharpness

AFM Modes In contact AFM electrostatic and/or surface tension forces from the adsorbed gas layer pull the scanning tip toward the surface. It can damage samples and distort image data. Therefore, contact mode imaging is heavily influenced by frictional and adhesive forces compared to non-contact or tapping mode. Non-contact imaging generally provides low resolution and can also be hampered by the contaminant layer which can interfere with oscillation. TappingMode AFM was developed as a method to achieve high resolution without inducing destructive frictional forces both in air and fluid. With the TappingMode technique, the very soft and fragile samples can be imaged successfully. Also, incorporated with Phase Imaging, the tapping mode AFM can be used to analyze the components of the membrane.

Images Phase imaging of a polymer blend

AFM Images AFM image of short DNA fragment with RNA polymerase molecule bound to transcription recognition site. 238nm scan size. Courtesy of Bustamante Lab, Chemistry Department, University of Oregon, Eugene OR

Images 10 µm scan Tapping Mode image of a CD (left) and a DVD (right) surface disc.